ET 01.06.2002 CMS detector resolution zCMS Silicon Strip Tracker zCMS Silicon Strip Detector Resolution zHIP Silicon Beam Telescope.

Slides:



Advertisements
Similar presentations
Vertex Detector: Engineering Issues Craig Buttar University of Glasgow Cambridge GLDC meeting Sept 07.
Advertisements

Proposal for a new design of LumiCal R. Ingbir, P. Ruzicka, V. Vrba October 07 Malá Skála.
The CMS Detector Paoti Chang National Taiwan University
Guoming CHEN The Capability of CMS Detector Chen Guoming IHEP, CAS , Beijing.
May 14, 2015Pavel Řezníček, IPNP Charles University, Prague1 Tests of ATLAS strip detector modules: beam, source, G4 simulations.
LHC SPS PS. 46 m 22 m A Toroidal LHC ApparatuS - ATLAS As large as the CERN main bulding.
Charged Particle Tracker for a RHIC/EIC joint detector Detector layouts based on EIC and NLC Physics drivers Silicon detector technologies Simulations.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
The SVT in STAR The final device…. … and all its connections … and all its connections.
4/25/2006 Puneeth Kalavase, UC, Santa Barbara On behalf of US Tracker Outer Barrel group Construction and Testing of CMS “Rods”
Track Reconstruction with the CMS Tracking Detector With proton-proton collision energy of 14 TeV at luminosity of cm -2 s -1, the LHC environment.
Patrick Spradlin, SCIPP trip to LLU, May 2, 2001 Detector Characteristics.
The Finnish CMS Collaboration Helsinki Institute of Physics S. Czellar, A. Heikkinen, J. Härkönen, V. Karimäki, H. Katajisto,R. Kinnunen,T. Lampén, K.
The Physics Potential of the PHENIX VTX and FVTX Detectors Eric J. Mannel WWND 13-Apr-2012.
LHeC : Muon Systems L. Pontecorvo.
1 CMS Tracker Alignment and Implications for Physics Performance Nhan Tran Johns Hopkins University CMS Collaboration SPLIT
Performance of ATLAS & CMS Silicon Tracker Alessia Tricomi University and INFN Catania International Europhysics Conference on High Energy Physics EPS.
1 Conceptual design adopts state-of-the-art silicon sensor techniques (compare ATLAS/CMS/ALICE inner tracker layers, BaBar tracking of B mesons). Design.
David Attié Club ‘ILC Physics Case’ CEA Saclay June 23, 2013 ILD & SiD concepts and R&D.
July CMS experiment at LHC Geoff Hall Imperial College London Geoff Hall.
Workshop on B/Tau Physics, Helsinki V. Karim ä ki, HIP 1 Software Alignment of the CMS Tracker V. Karimäki / HIP V. Karimäki / HIP Workshop.
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
Silicon Tracking Systems in Mokka Framework Valeri Saveliev, Obninsk State University.
CHEP06, Mumbai-India, Feb 2006V. Daniel Elvira 1 The CMS Simulation Validation Suite V. Daniel Elvira (Fermilab) for the CMS Collaboration.
Marcello Mannelli CMS Inner Tracking LHC Symposium May 2003 CMS Inner Tracking.
Status report on the Asian Solid State Tracking R&D March 31, 2003 M. Iwasaki University of Tokyo.
Operation of the CMS Tracker at the Large Hadron Collider
Semiconductor detectors An introduction to semiconductor detector physics as applied to particle physics.
Design and development of micro-strip stacked module prototypes for tracking at S-LHC Motivations Tracking detectors at future hadron colliders will operate.
The CMS detector as compared to ATLAS CMS Detector Description –Inner detector and comparison with ATLAS –EM detector and comparison with ATLAS –Calorimetric.
1 ATLAS SCT Endcap C Efficiency Measurement Nicholas Austin IoP Conference April 2009.
PHENIX Silicon Vertex Tracker. Mechanical Requirements Stability requirement, short and long25 µm Low radiation length
p-on-n Strip Detectors: ATLAS & CMS
Jonathan BouchetBerkeley School on Collective Dynamics 1 Performance of the Silicon Strip Detector of the STAR Experiment Jonathan Bouchet Subatech STAR.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
CP violation in B decays: prospects for LHCb Werner Ruckstuhl, NIKHEF, 3 July 1998.
CGEM-IT project and beam test program G. Felici for the FE-LNF-TO team Partially supported by the Italian Ministry of Foreign Affairs under the Program.
Printing: This poster is 48” wide by 36” high. It’s designed to be printed on a large-format printer. Customizing the Content: The placeholders in this.
The CMS Silicon Strip Tracker Carlo Civinini INFN-Firenze On behalf of the CMS Tracker Collaboration Sixth International "Hiroshima" Symposium on the Development.
TeV muons: from data handling to new physics phenomena Vladimir Palichik JINR, Dubna NEC’2009 Varna, September 07-14, 2009.
DØ Beauty Physics in Run II Rick Jesik Imperial College BEACH 2002 V International Conference on Hyperons, Charm and Beauty Hadrons Vancouver, BC, June.
SiD Tracking in the LOI and Future Plans Richard Partridge SLAC ALCPG 2009.
SPHENIX Mid-rapidity extensions: Additional Tracking system and pre-shower Y. Akiba (RIKEN/RBRC) sPHENIX workfest July 29,
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
RD07, June Firenze Alignment Strategy for the CMS Silicon Tracker Marco Rovere 1 for the CMS Collaboration 1 Università di Milano-Bicocca & INFN.
Operation & Performance of the ATLAS SemiConductor Tracker Dr. Petra Haefner Max-Planck-Institut für Physik.
Photon & e+e- Hits in Muon Higgs Factory T. Markiewicz T. Maruyama SLAC MAP Collaboration Meeting. Fermilab 29 May 2014.
Atlas SemiConductor Tracker final integration and commissioning Andrée Robichaud-Véronneau Université de Genève on behalf of the Atlas SCT collaboration.
Test beam results of MCz-Si detectors
Alignment of the CMS Tracker
Tracking detectors/2 F.Riggi.
 Silicon Vertex Detector Upgrade for the Belle II Experiment
IOP HEPP Conference Upgrading the CMS Tracker for SLHC Mark Pesaresi Imperial College, London.
ICHEP02 Chris Parkes ALICE m2 Pixels+Drift+Strips LHCb m2
Layout of Detectors for CLIC
CMS muon detectors and muon system performance
Silicon Pixel Detector for the PHENIX experiment at the BNL RHIC
Integration and alignment of ATLAS SCT
Martin Weber RWTH Aachen 1st LHC Detector Alignment workshop CERN
The Compact Muon Solenoid Detector
CMS Tracker Operational Experience
ILC Detector Activities in Korea
CMS Tracker Alignment with Cosmic Data and Strategy at the Startup
5% The CMS all silicon tracker simulation
The LHC collider in Geneva
Muon Detector Jiawen ZHANG 16 September 2002.
Lecture 22.
Project Presentations August 5th, 2004
Performance of ATLAS & CMS Silicon Tracker
The ATLAS & CMS Tracking Detectors
Presentation transcript:

ET CMS detector resolution zCMS Silicon Strip Tracker zCMS Silicon Strip Detector Resolution zHIP Silicon Beam Telescope

ET CMS Silicon Strip Tracker zDiameter 2.4 m, Length 5.6 m zTracker Inner Barrel (TIB), Tracker Inner Disks (TID), Tracker Outer Barrel (TOB), Tracker End Caps (TEC) zTemperature -10 C cm 120 cm m

ET CMS Silicon Strip Detectors z n-type FZ Silicon wafers, p+ strips, AC coupled, single-sided z Strip width: strip/pitch ~ 0.25, strip length typically 12.5 cm Wafer thickness  m Resistivity k  cm barrel detectors  m disk detectors  m Inner Tracker3201.5–3.080 or … Outer Tracker5003.5– or …

ET Needs for Detector Resolution zObjective of CMS and Tracker: to detect signatures of new physics at LHC zMethod: by identifying and precisely measuring leptons, photons and jets zTools: Tracking and Vertex reconstruction within a strong 4 T magnetic field zTracker measurements are combined with track segments reconstructed in the outer muon system -> to further extend the region over which a precise MUON momentum measurement can be performed (-> alignment)

ET Requirements for the Detector Resolution zCMS Tracker is designed to ensure high quality momentum resolution: y momentum resolution better than  p T /p T = 0.15*p T (in TeV/c), all   2.5 zHit resolution requirements for successful track reconstruction: x around 15 Tracker inner radius x around 40 Tracker outer radius zThis means: x Pixel: barrel 10 –15 um endcaps 15 –20 um x TIB: better than 20 um for shorter pitches approaching (pitch/neliojuuri12) for larger pitches x TOB:pitch 140 um -> resolution better than 40 um pitch 210 um -> resolution better than 60 um (for hight pT tracks)

ET Studies of Single Track Performance zStudy of single hit quality for several pitch values zStudy of single muon tracks of several pT values in all silicon tracker z-> evaluation of the precision of the track reconstruction performance zAccumulation of 500 tracks for statistics zCMSIM & GEANT

ET Test beam results of the Detector Resolution zBarrel strip detector: 50 um pitch, 12.5 cm length -> hit resolution 11 um zDouble-sided detectors: pitch 100 um, stereo angle 100 mrad -> resolution 34 um orthogonal to stereo strips and 320 um in the stereo coordinate zWedge detector: 6.25 cm strips, um pitch -> resolution 7 um zThe dependence of the resolution on the signal-to-noise-ratio, bias voltage and incidence angle is weak

ET HIP Silicon Beam Telescope zOur ”mini-Tracker” z8 layers of Silicon detectors & adequate read-out electronics and DAQ zPitch 55 um zSpatial resolution obtained in summer 2001 beam tests: 10  m zSummer 2002: our own rad-hard Cz detectors & stereo angle detector