BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9.

Slides:



Advertisements
Similar presentations
Tandberg MXP Training Version 1.1, By David Anstee, First Connections Ltd.
Advertisements

Data Projector Setting Up/Connecting Laptop & Data Projector.
Agnes Varis Campus Center Auditorium Audio Visual Training.
Introducing Digital Talking-Book Machines Standard player Advanced player.
Tandberg Basic Operating Guide Classic Systems Collaborative Services Education Technology Services The School Board of Broward County, Florida.
JED Microprocessors Pty Ltd Presenting the JED T430 low-cost Projector Controllers Nov 22nd, 2009.
966A-L3 TRUNK SIGNALING ANALYZER
AN INTRODUCTION TO THE BTS-1000 (BERD DAWG) COMMUNICATIONS TEST SET SLIDE 1 OF 22.
AC-SSC-1 Installation and operation manual
LogTag Training January 2015
InnoSys Process Sequence. End Effector Components End Effector Prox Switch Load Cell Wire Conduit Crows Foot Nut Runner.
Using Telemedicine Equipment. Overview The ‘Big’ Picture The ‘Bigger’ Picture Equipment Setting Up A Video Conference Conducting A Video Conference Common.
IP Communications Training 6900 Series. Getting to Know Your Phone LCD Screen Line Buttons Soft Keys Transfer, Conference, Hold Keys Headset Button Speakerphone.
XL40D Training. The Clarity Professional XL40D offers our patented Digital Clarity Power that uses digital technology to enhance the volume and clarity.
University of Manitoba A How to Guide for Theatre B & C.
1 Check all equipment is included before returning. If you have an accident or the equipment is damaged or you need support please contact Blaize
WALTON SMART SOLUTIONS Audio-Video-Technology Systems Integration Specialists 1 WAB Standardized Classroom WAB Standardized Classroom from ICT has a new.
Crown DSi Series Control Click the Crown Logo at the top of any the screen to return to this Menu Interactive Main Menu Interactive Front Panel Display.
Quick Operation Guide System Controller WV-CU650 Main Functions (1) WV-CU650 Start Up Login 1. Turn on the power and wait for the Login standby display.
The Handling Camera1 Trainer Training The Handling Camera.
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
Graphic Symbol Location 1. DIN Terminal X52 The machine is powered by electricity using copper cable with 5 wires (3 phase wires + neutral wire +
Electric Guitar Controls D. Hunt Southern Wells Jr-Sr High School
MySOS User Guide.
Bmd Crossvent 3.
Cisco VoIP Wireless Telephone 7921G Model Please press the F5 key on your PC to begin the presentation Click to advance IT Support Center or
M3903 Enhanced Telephone The M3903 Enhanced Telephone is a multi-line digital phone supporting up to four lines and/or features. The productivity- enhancing.
Office of Emergency Communications Gateway Training Workshop Module Three Hands-on Configuration Incident Commanders Radio Interface (ICR)
VLT Diagnostics Click on the button above your Keypad.
July 2008 Fairfield Fire Department Bendix King EPH and GPH Portable Radios FAIRFIELD FIRE DEPARTMENT.
May 2007 North Zone – Communications Bendix King EPH and GPH Portable Radios North Zone Communications Committee.
How to use the STELR multimeter
Paver System Five Control Box Overview Aug 2009 Control Box Overview Paver System Five.
MySOS Device User Training
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
M3902 Basic Telephone This is the standard University of Alberta phone. The M3902 brings the display-based interface and handsfree capability to this basic,
The Headphones1 Trainer Training The Headphones. 2 There are three sets of headphones There are three transmitters Transmitters also act as battery chargers.
The Mavica for the Maverick: A How-to Guide Operating instructions for the Sony Mavica CD350 Digital Camera An Easy-to-Follow Guide to Everything You Need.
PSU Outreach VLN Technical Training and Best Teaching Practices.
TL70 The Choice is Yours: You choose how to order and build the TL70 with the flexibility to customize the tower light as needed and change positions in.
1 Security Systems ST-CO/GP | 11/21/2006 | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights.
GCS 300 System Operation Application – Level 1.
Communication Markets Division © 3M All Rights Reserved. 965AMS Product Overview.
Intuitive Programming System For The Mill
By : Anand Kochhar Video Conferencing. End User Training on Tandberg-990MXP By Anand Kochhar Mobile: Video
Introduction to the Oscilloscope Professor Ahmadi ECE 002.
Power Fit Training Congratulations! Now that you have completed your test – you are ready for your training. This training program is based off the level.
TANDBERG VIDEO CONFERENCING SYSTEMS. CONTENTS USAGE OF REMOTE CONTROL INITIATE A POINT TO POINT CALL INITIATE A MULTIPOINT CALL DUO VIDEO SOME OTHER FEATURES.
Service Section Technical Training December 2005.
PSU Outreach VLN Technical Training and Best Teaching Practices.
InnoSys Park Brake Tool Master Control Panel Screens Revision A, 12Dec /12/20071.
Spring Hill Assembly1 InnoSys Park Brake Tool Master Control Panel Screens 1 3-Mar-2008.
ST/PRM3-EU | | © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Hardware Configuration Guide Configuring Dongles and Creating Barcodes for Devices Used with VSC.
Using electrical Test Equipment To accompany the Georgia Agriculture Curriculum Course: AG-AG-AMII Using Electrical Test Equipment 2010 VGP.
USER GUIDE TEMPERATURE CONTROLLER TR-2006 Hot runner temperature controller ShenZhen TanRex Electronic Co.ltd.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
Yeti 400 Reprogram SOP 5/1/2017, Yeti firmware rev. 2.0.
AN INTRODUCTION TO THE BE9000-DP DUAL DROP & INSERT OPTION FOR
LIFEPAK® 1000 Defibrillator Orientation Guide
Laser 3000™ Operating Instructions
PHASE IDENTIFICATION UNIT (PIU)
AM-7026 Down Converter-Receiver
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
STELR Ranging Multimeter
6. USING THE TDR200 IN ANALOGUE MODE
Sony PCM-M10 Recorder Asst. Superintendent for H.R.
2019 Investing Now Summer Program
Presentation transcript:

BE-2110i VF/WIDEBAND TRANSMISSION TEST SET OPERATING OVERVIEW Slide 1 of 9

Slide 2 of 9

F KEYS: These keys bring up the MAIN MENUs of the test set SYSTEM SET UP functions. In this area, Date, Time, and other System Parameters and thresholds are set. NOTE: Pressing the key the first time serves to make the selection you wish to change. Pressing the key a second time serves as the enter function, which enters your selection in the test set software. NORMAL/REVERSE: In the NORMAL position the SEND/2W/4W jack is the send jack and the REC/4W jack is the receive jack. In the REVERSE position, the functions of the jacks are reversed. A corresponding LED lights to indicate the selection. 2W/4W Provides testing of a 2 wire or a 4 wire circuit. In the 4W position, both the send and receive line interface jacks are connected to the test set. When 2W is selected, only the SEND/2W/4W jack is connected to the test set. A corresponding LED lights to indicate the selection. Default setting at POWER ON is 2W, RECEIVE, REVERSE, BRIDGED. LOUDSPEAKER Slide 3 of 9

POWER: Turns the test set on and off. When turning the test set on, a SELF TEST routine is started, which requires 10 seconds to complete. A message on the screen indicates "PERFORMING SELF TEST" during this process. At the end of the self test routine, all LED's light, and a message appears on the screen "SELF TEST PASSED". Pressing this key a second time while ON will light the display back light. Due to power consumption, the back light should not be left on for extended periods. In order to turn the test set off, the POWER key must be pressed and held for 2 seconds. SELECT: This key controls level and frequency output. Frequency output is selected by the middle key in this panel. Pressing SELECT places a cursor in the dBm or Hz area of the SEND Screen (left panel). The dBm or Hz selection can be changed by pressing SELECT a second time. This key is also used to adjust test set default settings and other functions such as date, time and so forth The middle key in the SEND Panel selects one of four fixed frequencies, or VARiable FREQuency, or FAST or SLOW SWEEP or QUIET TERM. The bottom key in the SEND panel is used to select the SEND impedance. Pressing the curved arrow in this key moves the selection clockwise or counterclockwise. Slide 4 of 9

The Screen Display has two areas, one outlined in BLACK to display the SEND values (frequency and level), and one outlined in RED to display the received values (frequency, level, noise, impulse noise). F KEYS: These keys bring up the MAIN MENUs of the test set SYSTEM SET UP functions. In this area, Date, Time, and other System Parameters and thresholds are set. NOTE: Pressing the key the first time serves to make the selection you wish to change. Pressing the key a second time serves as the enter function, which enters your selection in the test set software. WIDE BAND: This key sets up the test set for wideband measurements (up to 125 kHz). When the LED lights, wideband measurements (up to 125 kHz) can be made. Normal "voice band" measurements are up to 4 kHz. If a filter with frequencies greater than 4 kHz is selected, the unit will automatically enable the wideband function. IMPULSE TEST: When the IMPULSE TEST button is pressed the first time, the test set prepares itself to run a test for a five minute period. The IMPULSE TEST LED lights solid to indicate that the impulse test mode has been entered. The RECEIVE Screen will show 0 Counts and 70.0 dBrn (both are default values, which can be changed). Pressing the key a second time starts the test. Press the key during the test to stop the test. Slide 5 of 9

REL DELTA: This key selects the RELative measurement function. When tone is received at any level, pressing the REL/DELTA key (the LED will light) will set that received level as 0.0 dB. The test set will now show all received levels relative to 0.0 dB. Any changes in the Received Level will now be displayed as a + or - value relative to the set level. This function is of value when performing frequency slope measurements on a circuit. ABS SNR: In the ABS mode, all level measurements are displayed in dBm. All noise measurements are displayed in dBrn. In the SNR mode, the 1 kHz Notch filter is automatically enabled and the user has the ability to enable another voice band filter in conjunction with the 1 kHz Notch filter. Now all measurements are displayed in dB. HOLD DIAL: In the DIAL position, the REC jacks are disconnected from the REC side HOLD circuit and connected to the BUTT-SET jack, allowing dialing on the circuit from another location or a butt-set. While in the DIAL position, the test set is bridged onto the REC jacks, allowing the operator to use the test set's monitor if needed. In the HOLD position, the REC jacks are connected to the test set's selected REC impedance and HOLD circuit, which will hold the connection of a dialed up circuit. A corresponding LED lights to indicate the selection. Slide 6 of 9

This key selects one of 7 terminating impedances or BRIDGE for the REC portion of the test set. In the BRIDGE position, the test set is connected directly across the receive line without a terminating impedance. Pressing the curved arrows moves the selection clockwise or counterclockwise. A corresponding LED lights to indicate the selection. This key selects the type of measurement to be made by the test set: LEVEL; 5 choices of Voice Band Noise measurements; 15 kHz FLAT, E FILTER (for pre-qualifying a Basic Rate ISDN Circuit). When 15 kHz FLAT or E ISDN FLTR is selected, the test set automatically goes into the WIDEBAND mode as indicated by the LED in the WIDEBAND key area. This key selects the MONITOR function via the built in speaker for either the SEND output or REC input of the test set. Volume is controlled by pressing the right arrow for REC monitoring volume or the left arrow for SEND monitoring volume. Maximum is far right for input (REC) and far left for output (SEND). The relative monitoring level is indicated by the corresponding LEDs. The MONITOR function can be turned off by pressing either arrow until the LED above OFF lights. Slide 7 of 9

SIDE PANEL OF THE 2110i SERIAL PORT REC SEND 4W 2W/4W REC/4W jack for connection to the REC side of a 4W circuit. SEND/2W/4W jack for connection to the SEND side of a 4W circuit, or to a 2W circuit. T568A - RJ45 jack for Send & Receive modular connections. BUTT-SET - RJ45 jack for connection of a Technicians talk set (butt-set). The RS-232C Serial Port on the Side Panel is unused at the present time, and is reserved for features currently under development. 12VDC 500mA - Connect the supplied external AC adapter to the test set. NOTE: Although the test set will operate correctly with the adapter connected, the adapter is NOT a battery eliminator. The test set requires a battery to operate correctly. BATT LED's: Flashing Green LED - Indicates that external power is applied to the test set, and the battery is charging normally. Solid Green LED - Indicates that external power is a applied to the test set, and the battery is fully charged. Solid Red LED - Indicates that a charging fault has occurred, and external power should be remove from the test set. No LEDs illuminated - Indicates that no external power is present. Slide 8 of 9

CONGRATULATIONS!!!!!!!!!!!!! YOU HAVE COMPLETED THIS OVERVIEW AND ARE NOW READY TO BEGIN TESTING FOR REAL. PLEASE REFER TO YOUR OPERATOR’S MANUAL FOR MORE DETAILS ABOUT TESTING SPECIFIC TYPES OF CIRCUITS AND CONDITIONS. THANKS FOR YOUR BUSINESS BERRY TEST SETS Slide 9 of 9