On-Line CAFS Orientation Montgomery County Fire & Rescue Service Class B Foam Theory and Deployment.

Slides:



Advertisements
Similar presentations
QA September 2001 Fire Topic
Advertisements

Foam.
Module 5: Fire Fighting Foam Principles and Ethanol-Blended Fuel
Fire Apparatus Pump Theory
Foam is generated by mixing foam concentrate and water in correct ratios
Types of Concentrates (Water Additives). 13 Foam Concentrate - Water Additives Wetting agents Class A foam concentrate –Class A Foam Class B foam concentrate.
Section IV Foam Application and Operations
Firefighting Foam.
Blitzfire Deck Gun Ground Monitor
How would you explain this on the 3394? If Fire Erupts on YOUR Boat If Underway, stop the boat Have everyone who is not wearing a PFD put one on Position.
CAFS On-Line Orientation
1 Expansion Tanks. 2 3 Expansion Tanks WHY USE THEM TYPES LOCATION SIZING.
Nozzles, Fire Streams, and Foam
Fire Streams Geronimo Vol. Fire Dept.. Extinguishing Properties of Water G Water extinguishes fires by G Cooling G Remove heat from the fire G Smothering.
Chapter 14 Lesson Goal After completing this lesson, the student shall be able to effectively apply fire fighting foam using various foam types, concentrates,
Module 5: Fire Fighting Foam Principles and Ethanol-Blended Fuel.
Driver Recert 2013 Topics Review of Water Supply SOG’s MAWW Main St. Tank OOS BlitzFire Deployment with Water Thief Tower Operations Foam System Review.
FOAM 101.
Proportioning Systems. 69 Proportioning Systems Now you know the benefits and uses of water additives, especially Class A foam. So how do we get the concentrate.
Service Delivery 3 Foam Aim To provide students with information to enable them to control and extinguish fires using foam.
Florida Operations Level Hazardous Materials Training Unit 5.4 MISSION SPECIFIC: Leak, Spill and Fire Control.
Low Expansion Foam NFPA 11 class B forms blanket
Fire Streams SFFMA Training Objectives: –
CAFS On-Line Orientation
Foam Application Rates for E85 and E-95. Application Rates Described in Terms of the Amount in Gallons of Foam Solution Reaching the Total Square Footage.
1 Module 5: Fire Fighting Foam Principles and Ethanol-Blended Fuel.
Nozzles, Fire Streams, and Foam
Fire Streams Module II & III.
CAFS On-Line Orientation Montgomery County Fire & Rescue Service Class A Foam Theory.
WATER SUPPLY Copyright© Delmar is a division of Thomson Learning.
C L A S #4 Driver Operator Refresher Training.
Foam.
Module B Nozzles and Fire Streams
FOAM APPLICATION TECHNIQUES
CAFS On-Line Orientation Montgomery County Fire & Rescue Service Operating the CAFS Controllers.
QuickTrain CrewReview. QuickTrain CrewReview trainings have been developed to serve as brief springboards for crews to discuss emergency response theory.
Intermediate SFFMA Objectives: – Hrs Received
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
Lease Automatic Custody Transfer
Water Handling Operations
Automotive Fuel and Emissions Control Systems 3/e By James D. Halderman Copyright © 2012, 2009, 2006 Pearson Education, Inc., Upper Saddle River, NJ
Nozzles and Fire Streams Part B FVCC Fire Rescue.
Instructor Lee Lautzenheiser
Plan 2 – Dead-end Seal Chamber Optional Jacket
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
Northvale Korting Fluid Jet Theory and Applications of Eductors By Patrick Belcher.
Fire Service Pump Operator - 11 Foam.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
ENGINES. VEHICLE / HEAVY EQUIPMENT SAFETY INSPECTION CHECKLIST OF 296.

Firefighter III Module B Water Supply (4-19) (4-19)
Nozzles and Fire Streams Part C FVCC Fire Rescue.
 Foam types and application procedures  Foam type currently in inventory  Calculations for foam flows / PSI  Response to Trucks / Trains  SPFD Response.
Class A Foam 101 Marysville Division of Fire 2009.
Compressed Air Foam System
Relay Pumping Operations Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
2013Q2.
Foam Equipment & Systems Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Fire Hose Nozzles & Flow Rates
 Trucks / Trains  Calculations for foam flows / PSI  Response Bulletin  Mutual Aid partners responsibilities  Air monitoring  What information do.
ATP FOAM SYSTEM Engine 438 Ansul / Rockwood Model B2 400 GPM Around The Pump Foam System.
CAFS On-Line Orientation
Fire Attack and Foam (Fire Fighter II)
Essentials of Fire Fighting
Pumping Apparatus Driver/Operator — Lesson 15
Pumping Apparatus Driver/Operator — Lesson 15
CAFS On-Line Orientation
On-Line CAFS Orientation
CAFS On-Line Orientation
FOAM APPLICATION TECHNIQUES HOSTED BY THE Jefferson County Fire and Rescue Training Academy.
Presentation transcript:

On-Line CAFS Orientation Montgomery County Fire & Rescue Service Class B Foam Theory and Deployment

 MCFRTA 2008 Class B Technology Module Objectives Understand Difference between Class A & B Foams Understand how Class B Foams work Understand how to make Class B Foam Understand MCFRS Class B Foam options

 MCFRTA 2008 Class A vs. Class B Foams Both Classes of Foam make bubbles and hold water. The difference lies in their degree of attraction to hydrocarbons. Class A Foams want to mix with hydrocarbons - which is good when we want the foam to cling to a burning surface. This is not so good when trying to smother a flammable liquid fire as the foam will break apart and sink to the bottom of the flammable liquid. Class B Foams do NOT want to mix with hydrocarbons and this is why they form a nice cohesive foam blanket on top of flammable liquids.

AFFF-ATC Aqueous Film Forming Foam - Alcohol Type Concentrate Designed for use on Multiple Hazards - Normal Hydrocarbon Fires Oil, Gasoline w/o MTBE or Ethanol, etc… - Polar Solvent Fires Gasoline with MTBE or Ethanol, Ethanol, Alcohols, etc… AFFF-ATCs have multiple use ratios (proportioning rates)

How does an AFFF-ATC work? Normal Hydrocarbon Fires Forms an aqueous film that advances ahead of the bubble blanket to smother the fuel. The aqueous film is “oleo-phobic” or “oil-hating”. The aqueous film and the foam blanket work together to smother the flammable liquid. The weight of the foam blanket plus the aqueous film is greater than the vapor density of the flammable liquid.

 MCFRTA 2008 How does an AFF-ATC Work? Normal Hydrocarbon Fires The film & blanket: - prevent the liquid from being able to convert from a liquid to a gas, preventing ignition. -prevent the oxidizing agent from coming in contact with the liquid. -absorbs heat from the liquid pool. All of these factors prevent ignition of the flammable liquid.

How does an AFFF-ATC work? On a Polar Solvent Fire When mixed with the proper volume of water, forms a polymeric membrane (due to added polymers in solution) This membrane prevents polar solvent pick-up, and degradation of the foam blanket. The membrane does not allow the water in the aqueous film or foam bubble blanket to come in contact with the polar agent. AFFF-ATCs must be utilized at the proper proportioning rates for effective use!

Chubb National Universal Gold 1% x 3% Most Probable Class B AFFF-ATC that will be used by MCFRS 1% proportioning ratio for normal hydrocarbon fires. 3% proportioning ratio for polar solvent fires.

MCFRS Class B Foam Proportioning Systems Foam Proportioning Systems refers to the method in which foam concentrate is introduced into hose streams. MCFR Spec - Feecon FoaMidget External Around-the-Pump System - 95 GPM Elkhart In-line Eductor

FoaMidget Around-the-Pump Features and Benefits Works over a wide range of flows and foam concentrate injection rates. Able to provide high (>500 GPM) Class B foam solution flow rates. Considerations Must have adequate Class B foam supply Must have adequate water supply (total gallons) Most Likely Use - Dedicated Pumper for large scale Class B operation - HAZMAT (6000-gallon fuel tanker - SB95 to OL495 ramp)

 MCFRTA 2008 FoaMidget Around-the-Pump Concerns during use No more than 10 psi suction-side (intake) pressure - so use tank water as you would with CAFS. Must make connections properly. Must keep pump-to-tank (Tank Fill) valve closed to avoid contamination of booster tank water. Must back-flush pump after use.

 MCFRTA 2008 FoaMidget Operation Set indicator to proper setting for the discharge flow.Set indicator to proper setting for the discharge flow. Open suction valve. Insert pickup tube into agent container.Insert pickup tube into agent container. Open discharge valve. When system shuts down, immediately remove pickup tube from container.When system shuts down, immediately remove pickup tube from container.

95 GPM In-line Eductor Concerns During Use Operator must maintain 200 PSI at the throat (inlet) of the eductor for the venturi to work properly. Cannot have: (due to back pressure issues) Too much fire hose after the device Improper Nozzle (Gallonage Mis-Match) Back pressure due to elevation, partially opened nozzles, greater than 6-foot lift from foam concentrate source to eductor

95 GPM In-line Eductor Attach Eductor to one of the 2.5” outlets on the pump panel. Thread end of Eductor pick-up tube onto fitting on pump panel. This fitting connects with Class B Foam Concentrate Tank. Then open the Class B Foam valve on the pump panel to get the concentrate flowing. Charge 2.5” discharge and pump at 200 psi. After Class B use, flush hose and all of eductor with plain water. Also flush piping by attaching garden hose to fitting and flowing plain water. This will flush out everything from Class B valve down.

Nozzle Aspirated Foam System (NAFS) Require the use of an air-aspirating nozzle to create bubbles. Different nozzles mix different volumes of air, creating different finished foam expansion rates. In general, the fatter the nozzle, the more air is entrained, and the higher the expansion ratio. NAFS are considered a “high volume, low energy” system. High Volume - due to Expansion Rate Low Energy - Fire Stream reach decreases due to the fact that hydraulic energy is used to entrain air.

Crimson Engine Class B NAFS Capabilities What does this mean to me as a pump operator? - 25 gallons of National Gold 1x3% - 95 GPM In-line Eductor with dedicated Air-Aspirating Nozzle This Class B foam proportioning system can handle : Normal Hydrocarbon Square Feet (Approx - 31’ x 31’) pool fire Polar Solvent Square Feet (Approx 20’ x 20’ ) pool fire gal. Saddle Tank or smaller car fuel tank spill

 MCFRTA 2008 Review Questions What is the proper proportioning rate for Chubb Universal Gold for use on an E85 pool fire? If you use 300 gallons of foam solution to put the above fire out, how many gallons of foam concentrate did you use? Explain how to use the 95 gpm In-line eductor:

 MCFRTA 2008 Final Thoughts - Safety Check! Pump Operations Foam Compatibility Attack Hose Compatibility Proper Hose Handling Techniques Foam Type Utilization Proper Bleeding, Breakdown and Take Up Practices …ON-GOING TACTICAL AND OPERATIONAL TRAINING!

 MCFRTA 2008 On-Line Program Credits MCFRS –FF Dominic Colletti, Jr., Sta. 6 C –Capt. Alan Butsch, Sta. 12 C –D/C Steve Lohr, Division of Operations Hale Products, Inc. –Dominic Colletti, Global Foam Products Manager –Rick Tull, Manager of Product Training Kidde, Inc.

 MCFRTA 2008 Credits Photos: –Hale Pumps, Kidde Inc., A. Butsch, D. Colletti Jr. Special Thanks: –FP M. Lumsden, 12 C; FP D. Schaefer, 12 B Editorial Assistance –Capt.s Bartlett, Hinkle, Williamson - PSTA Blackboard, Infrastructure Support –Jeff Feiertag IT, FP Barclay 04 A Computer Support