This article and any supplementary material should be cited as follows: Tang KT, Spence WD, Maxwell D, Stansfield BW. Validity of method to quantify transtibial.

Slides:



Advertisements
Similar presentations
This article and any supplementary material should be cited as follows: Sanders JE, Severance MR, Swartzendruber DL, Allyn KJ, Ciol MA. Influence of prior.
Advertisements

This article and any supplementary material should be cited as follows: Paquet N, Taillon-Hobson A, Lajoie Y. Fukuda and Babinski-Weil tests: Within-subject.
This article and any supplementary material should be cited as follows: Cameron MH, Huisinga J. Objective and subjective measures reflect different aspects.
This article and any supplementary material should be cited as follows: Kumar SN, Omar B, Htwe O, Joseph LH, Krishnan J, Jafarzedah Esfehani A, Min LL.
This article and any supplementary material should be cited as follows: Kannenberg A, Zacharias B, Pröbsting E. Benefits of microprocessor- controlled.
This article and any supplementary material should be cited as follows: Barton JE, Sorkin JD. Design and evaluation of prosthetic shoulder controller.
This article and any supplementary material should be cited as follows: Sauret C, Bascou J, de Saint Rémy N, Pillet H, Vaslin P, Lavast F. Assessment of.
This article and any supplementary material should be cited as follows: Wilson RH, McArdle R. Characteristics of audiometric 4,000 Hz notch (744,553 veterans)
This article and any supplementary material should be cited as follows: Eicholtz MR, Caspall JJ, Dao PV, Sprigle S, Ferri A. Test method for empirically.
This article and any supplementary material should be cited as follows: Nightingale EJ, Pourkazemi F, Hiller CE. A Systematic review of timed stair tests.
This article and any supplementary material should be cited as follows: de Laat FA, van der Pluijm MJ, van Kuijk AA, Geertzen JH, Roorda LD. Cosmetic effect.
This article and any supplementary material should be cited as follows: Johnson L, De Asha AR, Munjal R, Kulkarni J, Buckley JG. Toe clearance when walking.
This article and any supplementary material should be cited as follows: Chang SR, Kobetic R, Triolo RJ. Understanding stand-to-sit maneuver: Implications.
This article and any supplementary material should be cited as follows: Meier MR, Tucker KA, Hansen AH. Development of inexpensive prosthetic feet for.
This article and any supplementary material should be cited as follows: Smit G, Plettenburg DH, van der Helm FCT. Design and evaluation of two different.
This article and any supplementary material should be cited as follows: Seifert AR. Absence of verbal recall or memory for symptom acquisition in fear.
This article and any supplementary material should be cited as follows: Wininger M, Crane B. Effect of interpolation on parameters extracted from seating.
This article and any supplementary material should be cited as follows: Makowski P, Knutson J, Chae J, Crago P. Interaction of poststroke voluntary effort.
This article and any supplementary material should be cited as follows: Larson RD, McCully KK, Larson DJ, Pryor WM, White LJ. Lower-limb performance disparities:
This article and any supplementary material should be cited as follows: Gailey RS, Scoville C, Gaunaurd IA, Raya MA, Linberg AA, Stoneman PD, Campbell.
This article and any supplementary material should be cited as follows: Raya MA, Gailey RS, Gaunaurd IA, Ganyard H, Knapp-Wood J, McDonough K, Palmisano.
This article and any supplementary material should be cited as follows: Hill K, Kovacs T, Shin S. Reliability of brain-computer interface language sample.
This article and any supplementary material should be cited as follows: Gerschutz MJ, Haynes ML, Nixon D, Colvin JM. Strength evaluation of prosthetic.
This article and any supplementary material should be cited as follows: Lindner HY, Langius-Eklöf A, Hermansson LM. Testretest reliability and rater agreements.
This article and any supplementary material should be cited as follows: Wolf EJ, Everding VQ, Linberg AL, Schnall BL, Czerniecki JM, Gambel JM. Assessment.
This article and any supplementary material should be cited as follows: Wezenberg D, Cutti AG, Bruno A, Houdijk H. Differentiation between solid- ankle.
This article and any supplementary material should be cited as follows: Webster JB, Hakimi KN, Williams RM, Turner AP, Norvell DC, Czerniecki JM. Prosthetic.
This article and any supplementary material should be cited as follows: Smit CA, Legemate KJ, de Koning A, de Groot S, Stolwijk-Swuste JM, Janssen TW.
This article and any supplementary material should be cited as follows: Dille MF, Jacobs PG, Gordon SY, Helt WJ, McMillan GP. OtoID: New extended frequency,
This article and any supplementary material should be cited as follows: Watson EC, Cosio D, Lin EH. Mixed-method approach to veteran satisfaction with.
This article and any supplementary material should be cited as follows: Garcia-Mendez Y, Pearlman JL, Cooper RA, Boninger ML. Dynamic stiffness and transmissibility.
This article and any supplementary material should be cited as follows: Waid-Ebbs JK, Daly J, Wu SS, Berg WK, Bauer RM, Perlstein WM, Crosson B. Response.
This article and any supplementary material should be cited as follows: Sanders JE, Severance MR, Allyn KJ. Computer-socket manufacturing error: How much.
This article and any supplementary material should be cited as follows: Juhnke D, Beck JP, Jeyapalina S, Aschoff HH. Fifteen years of experience with Integral-Leg-Prosthesis:
This article and any supplementary material should be cited as follows: Schoeman M, Diss CE, Strike SC. Asymmetrical loading demands associated with vertical.
This article and any supplementary material should be cited as follows: Raja B, Neptune RR, Kautz SA. Quantifiable patterns of limb loading and unloading.
This article and any supplementary material should be cited as follows: Komolafe O, Wood S, Caldwell R, Hansen A, Fatone S. Methods for characterization.
This article and any supplementary material should be cited as follows: Guidali M, Keller U, Klamroth-Marganska V, Nef T, Riener R. Estimating the patient’s.
This article and any supplementary material should be cited as follows: Mahajan HP, Spaeth DM, Dicianno BE, Brown K, Cooper RA. Preliminary evaluation.
This article and any supplementary material should be cited as follows: Zhang M, Davies TC, Zhang Y, Xie S. Reviewing effectiveness of ankle assessment.
This article and any supplementary material should be cited as follows: Fatone S, Dillon M, Stine R, Tillges R. Coronal plane socket stability during gait.
This article and any supplementary material should be cited as follows: Alcaide-Aguirre RE, Morgenroth DC, Ferris DP. Motor control and learning with lower-limb.
This article and any supplementary material should be cited as follows: van Nunen MP, Gerrits KH, de Haan A, Janssen TW. Exercise intensity of robot-assisted.
This article and any supplementary material should be cited as follows: Fu J, Jones M, Jan Y. Development of intelligent model for personalized guidance.
This article and any supplementary material should be cited as follows: Ishikawa S, Stevens SL, Kang M, Morgan DW. Reliability of daily step activity monitoring.
This article and any supplementary material should be cited as follows: Hansen A, Nickel E, Medvec J, Brielmaier S, Pike A, Weber M. Effects of a flat.
This article and any supplementary material should be cited as follows: Sinitski EH, Lemaire ED, Baddour N. Evaluation of motion platform embedded with.
This article and any supplementary material should be cited as follows: Marchiori C, Bensmail D, Gagnon D, Pradon D. Manual wheelchair satisfaction among.
This article and any supplementary material should be cited as follows: Hafner BJ, Sanders JE. Considerations for development of sensing and monitoring.
This article and any supplementary material should be cited as follows: Redfield MT, Cagle JC, Hafner BJ, Sanders JE. Classifying prosthetic use via accelerometry.
This article and any supplementary material should be cited as follows: Chin T, Kuroda R, Akisue T, Iguchi T, Kurosaka M. Energy consumption during prosthetic.
This article and any supplementary material should be cited as follows: Gibson CA. Review of posttraumatic stress disorder and chronic pain: The path to.
This article and any supplementary material should be cited as follows: Meier MR, Hansen AH, Gard SA, McFadyen AK. Obstacle course: Users’ maneuverability.
This article and any supplementary material should be cited as follows: Fox A, Sanderlin JB, McNamee S, Bajaj JS, Carne W, Cifu DX. Elevated liver enzymes.
This article and any supplementary material should be cited as follows: Berning K, Cohick S, Johnson R, Miller LA, Sensinger JW. Comparison of body-powered.
This article and any supplementary material should be cited as follows: Hebert JS, Lewicke J. Case report of modified Box and Blocks test with motion capture.
This article and any supplementary material should be cited as follows: Ficanha EM, Rastgaar M, Kaufman KR. Ankle mechanics during sidestep cutting implicates.
This article and any supplementary material should be cited as follows: Tsai J, Rosenheck RA. Homeless and nonhomeless VA service users likely eligible.
This article and any supplementary material should be cited as follows: Linberg AA, Roach KE, Campbell SM, Stoneman PD, Gaunaurd IA, Raya MA, Gomez-Orozco.
This article and any supplementary material should be cited as follows: Ghoseiri K, Safari MR. Prevalence of heat and perspiration discomfort inside prostheses:
This article and any supplementary material should be cited as follows: Hollington J, Hillman SJ. Can static interface pressure mapping be used to rank.
This article and any supplementary material should be cited as follows: Resnik L, Klinger SL, Etter K. User and clinician perspectives on DEKA Arm: Results.
This article and any supplementary material should be cited as follows: Sensinger JW, Lipsey J, Thomas A, Turner K. Design and evaluation of voluntary.
This article and any supplementary material should be cited as follows: Smit G, Plettenburg DH. Comparison of mechanical properties of silicone and PVC.
This article and any supplementary material should be cited as follows: Kahle JT, Highsmith MJ. Transfemoral sockets with vacuum-assisted suspension comparison.
This article and any supplementary material should be cited as follows: Johnson WB, Fatone S, Gard SA. Modeling effects of sagittal-plane hip joint stiffness.
This article and any supplementary material should be cited as follows: Major MJ, Johnson WB, Gard SA. Interrater reliability of mechanical tests for functional.
This article and any supplementary material should be cited as: Segil JL, Weir RF. Novel postural control algorithm for control of multifunctional myoelectric.
This article and any supplementary material should be cited as follows: Boone DA, Kobayashi T, Chou TG, Arabian AK, Coleman KL, Orendurff MS, Zhang M.
Evaluation of an Activity Monitor for the Objective Measurement of Free-Living Physical Activity in Children With Cerebral Palsy  Kit Tzu Tang, EngD,
Presentation transcript:

This article and any supplementary material should be cited as follows: Tang KT, Spence WD, Maxwell D, Stansfield BW. Validity of method to quantify transtibial amputees’ free-living prosthetic wearing times and physical activity levels when using suction suspension sockets. J Rehabil Res Dev. 2012;49(3):427–38. Slideshow Project DOI: /JRRD JSP Validity of method to quantify transtibial amputees’ free-living prosthetic wearing times and physical activity levels when using suction suspension sockets Kit Tzu Tang, EngD; William D. Spence; Douglas Maxwell; Benedict Williams Stansfield, PhD

This article and any supplementary material should be cited as follows: Tang KT, Spence WD, Maxwell D, Stansfield BW. Validity of method to quantify transtibial amputees’ free-living prosthetic wearing times and physical activity levels when using suction suspension sockets. J Rehabil Res Dev. 2012;49(3):427–38. Slideshow Project DOI: /JRRD JSP Aim – Validate analysis algorithm (based on pressure at socket relief valve) for quantifying prosthesis wearing times, walking times, and stride count. Relevance – Laboratory gait analyses don't provide evidence of amputees' levels of daily free-living activity, and questionnaires are subjective. – Monitoring prosthesis wearing times and users’ physical activity would provide invaluable information about rehabilitation progress and prosthesis suitability.

This article and any supplementary material should be cited as follows: Tang KT, Spence WD, Maxwell D, Stansfield BW. Validity of method to quantify transtibial amputees’ free-living prosthetic wearing times and physical activity levels when using suction suspension sockets. J Rehabil Res Dev. 2012;49(3):427–38. Slideshow Project DOI: /JRRD JSP Methods 8 participants with transtibial amputation were fitted with custom-made suction sockets. Analysis algorithms automatically characterized physical activity based on pressure at socket’s relief valve. – Generally applicable algorithm that required no participant-specific calibration. Algorithms were validated in laboratory-based protocol that included walking, stair climbing, standing, sitting, donning, and doffing.

This article and any supplementary material should be cited as follows: Tang KT, Spence WD, Maxwell D, Stansfield BW. Validity of method to quantify transtibial amputees’ free-living prosthetic wearing times and physical activity levels when using suction suspension sockets. J Rehabil Res Dev. 2012;49(3):427–38. Slideshow Project DOI: /JRRD JSP Results Analysis algorithms vs concurrent video analysis: – High intraclass correlation coefficients (>0.98) for agreement between “off,” “static,” and “dynamic” times and stride count. Results demonstrate that pressure at pressure-relief valve of suction suspension sockets can be used to determine wearing times and activity state.

This article and any supplementary material should be cited as follows: Tang KT, Spence WD, Maxwell D, Stansfield BW. Validity of method to quantify transtibial amputees’ free-living prosthetic wearing times and physical activity levels when using suction suspension sockets. J Rehabil Res Dev. 2012;49(3):427–38. Slideshow Project DOI: /JRRD JSP Conclusions This monitoring solution: – Successfully used pressure at pressure-relief valve of suction suspension sockets to determine wearing times and activity state. – May allow quantification of multiple days of prosthetic use and user activity in free-living environments. – Doesn’t interfere with prosthesis fit and requires minimal patient or clinician input. – Permits acquisition of free-living physical activity data without subjective error of questionnaire reporting.