Fire Hose and Appliances

Slides:



Advertisements
Similar presentations
Sprinkler Systems and Standpipe Operations
Advertisements

Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Intermediate SFFMA Objectives: – Hrs Received
Chapter 12 Lesson Goal After completing this lesson, the student shall be able to make hydrant connections and draft from a static water source according.
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use, care for, and perform maintenance on fire hose, couplings, hose.
Fire Hose and Appliances
Learning Objective 1 Describe the safety considerations taken when service testing a fire hose.
CVFD Training – Hose Practices
FIREFIGHTER I LESSON 12A. FIRE HOSE TERMS Expansion-ring gasket Expansion-ring gasket — Gasket used at the end of hose where it is expanded into coupling.
The Cleveland Load.
TFT Blitzfire.
Winchester Fire - Rescue
Fire Hose & Appliances Part D & Homework.
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use various hose appliances and tools, prepare a test site for service.
Getting Wet Stuff to the Red Stuff For 300 Years
Fire Hoses and Appliances Firefighter II Module A
Fire Hose Skills Firefighter II.
FIRE HOSE AND APPLIANCES
Blackwood Fire Company TL84 LDH Deployment/Restoration Training Module.
Tandem Pumping Video. INITIAL SIZE-UP When approaching the structure note the location of the FDC, Hydrant and Building Access.
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Augmenting Fire Standpipe Systems
Riding Assignments Presentation February 28, 2011.
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
Unit 5 Use of Water. Unit 5 Objectives b Explain different types of water use operations b Demonstrate laying a wet line with both simple and progressive.
Chapter 8 Portable Fire Extinguishers. Introduction Portable fire extinguishers designed to fight: –Small fires –Unusual fires –Fires that cannot be reached.
Water Supply Advantage of water as extinguishing agent w Water Abundance w Excellent heat absorption qualities w Easily moved long distances w Easily stored.
Pumping Apparatus Driver/Operator
CVFD Training – Water Supply SFFMA Training Objectives: –
CHAPTER 14 LADDERS Copyright© Delmar is a division of Thomson Learning.
CHAPTER 14 Copyright © 2007 Thomson Delmar Learning 14.1 Ladders.
HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE TRAINING FACILITY.
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
March 2001 Training Hillcrest Fire Department. Before we get started Pair up with someone Take and record their vitals.
Purpose of Standpipe and Hose Systems
Fire Hose / Appliances FFII Hillcrest Fire Department © 2001.
C L A S #4 Driver Operator Refresher Training.
Intermediate SFFMA Objectives: – Hrs received.
Fire Hoses, Nozzles, Portable lighting, appliances, and ladders.
Fire Hose, Nozzles, Streams, and Foam
Chapter 13 Lesson Goal After completing this lesson, the student shall be able to use, care for, and perform maintenance on fire hose, couplings, hose.
Water Supply.
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
1402 Hybrid Firefighter II 6th Edition Chapter 15 — Fire Hose South Carolina Fire Academy.
FVCC Fire Rescue FIRE HOSE AND APPLIANCES. OBJECTIVES 2-7.1Identify the construction features of hose (3-3.7, 3-3.9) 2-7.2Identify the types of fire hose.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
TIDBITS Hose made pryor to July 1987 will be taken out of service Hose that is frozen will be service tested again Color’d Hoses All test gauges.
Water Supply Skill Drills.
Fire Stream and Line Selection Firefighter II. Copyright © Texas Education Agency All rights reserved. Images and other multimedia content used.
TODAYS GOALS -Hose inventory -Hose loads -Hose deployment -Hose “ hands on”
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
Fire Service Hose Firefighter II. Copyright and Terms of Service Copyright © Texas Education Agency, These materials are copyrighted © and trademarked.
Fire Hose, Nozzles, Streams, and Foam
Part C  Accordion load  Lay the first length of hose in the bed on edge against the partition with the coupling at the rear of the bed  At the front.
Job Performance Requirement Soft-Sleeve Hydrant Connection.
Firefighter III Module B Water Supply (4-19) (4-19)
HOSE ROLLS Straight roll ◦Lay the hose out straight and flat on a clean surface ◦Roll the male coupling over onto the hose to start the roll ◦Form a coil.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
CHAPTER 16 Water Supply. Fire Fighter I Objectives Describe the equipment and procedures that are used to access static sources of water. Describe the.
Essentials of Fire Fighting 6 th Edition Firefighter I Chapter 15 — Fire Hose.
Water Shuttle Operations
Fire Hose, Nozzles, and Streams
Welcome To High Rise Operations ! Like The Jefferson's...
Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine.
Water Supply (Fire Fighter I)
Fire Attack and Foam (Fire Fighter I)
Essentials of Fire Fighting
Harwich Fire Department
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Presentation transcript:

Fire Hose and Appliances Chapter 10 Fire Hose and Appliances

Introduction Hose used to move water to fire Fire hose is a flexible conduit. Many materials are used to make hose. Couplings, adapters, and appliances used to connect hose Canada has unique threads and may be different from province to province. National Pipe Straight Hose (NPSH) is typically used for smaller hoses in Canada. National Hose Thread or National Standard Thread is typically used in the United States. 10.2

Construction of Fire Hose Hose and couplings Fire hose can be wrapped, braided, or woven. Specific types of hoses: Attack Supply hose Soft suction and hard suction Occupant use Forestry 10.3

Woven and rubber-coated fire hose. 10.4

Care and Maintenance of Fire Hose Careful folding and placement Folded at different places Hose bed should facilitate air flow. Steps can be taken to reduce damage to hose. 10.5

Types of Hose Coupling Couplings joins hose and appliances. Threaded and non-threaded couplings Made of brass, aluminium, or pyrolite Lugs or handles are used for tightening or breaking connection. 10.6

Care and Maintenance of Couplings Keep clean. Store properly. Do not drag couplings. Perform a visual inspection each time hose is reloaded. 10.7

Hose Tools and Appliances Tools include: Rope hose tools Wrenches Rollers Clamps Other items: valves, wyes, portable hydrants, strainers, pipes, caps, etc. 10.8

Various hose tools. 10.9

Hose roller. 10.10

Coupling and Uncoupling Hose Connecting hose couplings: One-person foot-tilt method One-person over-the-hip method Two-person over-the-hip method Uncoupling hose with spanners One-person knee-press uncoupling method 10.11

Hose Rolls Type of hose roll dictated by department policy Firefighters should practice all types of hose rolls. Straight/storage Single donut Twin or double donut 10.12

Hose Carries Type of hose carry is dictated by user and on-scene conditions. Firefighters should be proficient in all types of hose carries. Drain and carry Shoulder loop carry Single-section street drag 10.13

Hose Loads Dependent on type of firefighting operations a company will employ A well-trained company should perform any required fire scene tasks. Dutchman 10.14

A dutchman is a short fold of hose or a reverse fold that is used when loading hose and a coupling comes at a point where a fold should take place or when two couplings end up on top of each other. The dutchman moves the coupling to another point in the load. 10.15

Hose Loads (cont.) Accordion load Flat load Horseshoe load Straight finish load Slot load Triple layer load 10.16

Pre-connected combination loads include horseshoe, accordion, accordion layers or alternating horseshoe and accordion layers. (A) Horseshoe, accordion, accordion layers. (B) Alternating horseshoe and accordion layers. 10.17

A straight finish load simply involves taking the final length or two of a load and laying it flat across the top of the load. A rope with adapters, a spanner wrench, and a hydrant wrench attached allows the layout person quick access to all the necessary tools and enough hose to make the hydrant connection. 10.18

Stored Hose Load/Packs Apparatus carry stored hose rolls and special application hose packs Extra sections of rolled hose Hose packs are numerous in design and makeup. Straight roll Donut roll Double donut 10.19

Wildland Firefighting Hose Loads Firefighters stretch hoseline a great distance from engine. Hose is rolled and bundled together. Placing bundles together allows each firefighter to carry 60 metres (200 feet). 10.20

Advancing Hoselines— Charged/Uncharged The purpose is to advance hoselines to seat of fire and to supply water. Efficient manner Nozzle person Company officer Engine person 10.21

Advancing Hoselines— Charged/Uncharged (cont.) Advancing a horseshoe load Advancing the flat load from a pre-connect bed Advancing the minuteman load Advancing the triple-layer load 10.22

Into Structures Advancing a hoseline into a structure Careful placement of pumper and hoseline Proper selection of correct size and length hoseline Skilful execution by hose crew Crew selects hoseline and properly removes it from engine. Ensure adequate hose available at entry. Check door for heat before entering. 10.23

Up and Down Stairs If fire does not involve stairs, advance an uncharged line to fire floor. Advancing an uncharged line Advancing a charged line It is necessary to run hoseline up between handrails. Using rope or strap If stairwell or landing is involved with fire, crew must advance a charged line. 10.24

A crew advancing an uncharged hoseline up stairs. 10.25

Using a Standpipe System Engine driver connects to FDC. Hose crew connects to standpipe outlet and advances hoseline. Pumper first establishes a water supply. Hose load and type of coupling determine need for any adapters. Choose connection that gets system into service quickest. 10.26

After connecting the hose at the outlet and the discharge outlet of the pump, the line is charged to the proper pressure. The driver then returns to the outlet and opens the valve. 10.27

Working Hose off Ladders Safest manner is to advance uncharged hoseline up ladder. Advancing a charged hoseline over a ladder requires multiple firefighters. Operating a hoseline from ground ladder requires ladder to be securely tied in and heeled. 10.28

Firefighters passing a charged hoseline up a ladder from one firefighter to the next until it reaches the opening. 10.29

Establishing a Water Supply Connection Several different methods exist depending on: Type of water source Style of hydrant Hose lays used Whether a pumper will be used at the water source Firefighters’ duties and responsibilities 10.30

From Hydrants Using unsupported hydrant requires hoseline to be connected without engine at hydrant. Choose proper hydrant outlet. Flush hydrant. Hydrant valve opened Engine connection 10.31

The layout person pulls the layout section and enough hose to reach and wrap the hydrant. 10.32

From Static Water Supplies Uses engine and its hard sleeves to draft water Must be positioned close Connecting hard sleeve to dry hydrant is same procedure as connecting to regular hydrant. Vacuum must be created. 10.33

Extending Hoselines There will be occasions when line comes up short. Wildland fires Techniques to extending hoselines: Break-apart nozzle Hose clamp Wildland hose advancing and extension 10.34

Replacing Sections of Burst Hose Bursting hose requires immediate attention. Hose must be shut down by pump operator. If not possible, use other methods. Reconnect or add a section; pump operator will recharge line. 10.35

Hose Lay Procedures Bring water to fire location Forward lay Reverse lay Split lay 10.36

Deploying Master Stream Devices Master streams or heavy appliances Capable of flowing 1,325Lpm (350 gpm) Non-handheld water applicators Four basic types of master stream devices Wagon pipe Deluge set Monitor pipe Ladder pipe 10.37

Proper operations of portable deluge sets. 10.38

Fire Hose Inspection Test prior to service and annually. Use record-keeping system. Know how to remove defective hose from service and reporting procedures. Remove from service if worn, damaged, or does not pass service testing. Mark out-of-service hose. Record results of hose testing.

Lessons Learned Fire hose, adapters, and appliances allow firefighters to move water from source to pumper. Without these tools, firefighters would be limited in ability to move water. Firefighters must understand the proper use and care of tools. Best method of learning is practical application. 10.40