23-Aug-06 mgbersch Plasma Cleaner Instructions for Use.

Slides:



Advertisements
Similar presentations
Filter Changing Procedures For TEOM Series 1400ab and Model 8500 FDMS (B & C Types)
Advertisements

LUCAS 2 Compression Device
Brio 2000 / Brio 2000-M E-Learning Service Manual Rev. 0.0.
Safe Use and Operation of Vacuum Lines
How to use a Heart Rate Monitor. Equipment needed Heart Rate Monitor Watch Transmitter Strap.
Servicing Welch DRYFAST ULTRA Pump Models 2032
Evaporator Carbon coating. Evaporator Step 1 Check that all switches on control console are to OFF position. Automatic Vacuum Control knob should be.
1 FUEL SYSTEM SERVICE ENGINE CLEAN FUEL TOOL MODEL RX 777.
How to carry out experiments using MPMS March 2012 Takeshi NAKAGAWA.
Wheelchair Lift Training
Module 9: Performing HIV Rapid Tests Demonstration and Practice.
Sessler Group Safety Talk Safe Operation of Vacuum System for Avoiding Danger of Liquid Oxygen Ren-Tsung Wu October 23 rd,
FoamPro 1600 Series Fully automatic Class A foam ONLY
3” BACKWASH VALVE WITH SUPERSTAR ACTUATOR BASIC SERVICE MANUAL Does not apply to PLC-MP version SUPERSTARS.
 Power Cable-plug in when ready to project.  Audio/Video Cable- attach per directions on the next slide.  Mark your spot-you may wish to use tape on.
6200 Calorimeter Operation Colby College Version Parr Instrument Company.
4Identifying Leakage Source (Mech/ Elec) 4Mechanical Air Leak- Down 4Mechanical Air Leak- Up 4Electronic Drift- Up/ Down 4Load Cell Operation 4Understanding.
Using the Sandblaster.
Development of single actuator circuits
Clean Air Box Usage & Care CABs RAMs CO Monitors.
F LOTEC Training Presentation for Authorized Repair Centers This presentation is designed to supplement M-Service Manual InGage Regulator.doc Flotec, Inc.
Dennis Sabre Fire Appliances
1. Pump down the chamber from the atmosphere pressure 2. Using RHEED to obtain diffraction images 3. Open the RHEED chamber or venting from high vacuum.
Varian 3118 Thermal Evaporation System
Using the Unity 98 Cordless Response System Directions : Courtesy of IHC public relations.
AccuMax Multi-Point Injection Mechanics
1. Safe Use and Operation of Vacuum Lines, UCLA Chemistry and Biochemistry 2.
Introduction to Operation of the XL- 30 Scanning Electron Microscope Tutorial # 2 Introduction to Operation and Imaging.
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
Solar Cell conductive grid and back contact
March ) Pretreatment Tank 2) Aeration Chamber 3) Clarifier Chamber 4) Chlorinator 5) Holding Tank 6) Aerator Pump 7) Millenium Control Center 8)
Cressington 208 HR Sputter coater
350, 350A 2½”-12”. Modification Overview  Production of the 2½ - 10” sizes began in  Production of the “A” models began in This Indicates.
SIP POU cooler Installation Guide. Getting Started The SIP 2000 can be easily installed in most POU coolers in just a few minutes. The tools needed are.
This is the situation at the start of your experiment. The entire system is at vacuum, and the mercury is at the bottom part of the Toepler pump. From.
Hydraulic Booster System High Pressure (Supply) Low Pressure (Return)
BioRad Sputter Coater  Instructions for gold coating a SEM sample.  NO, it’s not your eyes. This image is out of focus.
Reser- Voir Turbo Pump 1 Five- Fold Turbo Pump 2 Scroll Pump1 Scroll Pump2 Tgt. Cham- ber N2N2 H2H2 P2 P1 P3 P4 P5 P6 Panel Tgt. Cell V2V1 V3 V0 E0 E1.
Booster Pump/ Compressor Procedures Rescue 31 Operator Instructions.
ARPWAVE devices RX100 ARP TRAINER. Power switch Output power dial Before turning on or off the unit or plugging in or unplugging cord, be sure the output.
Zeiss Neon 40 EsB Sample Insertion/Removal
How to Use Galileo Laptop Computers. Unplug the laptop from the computer on wheels!
Triangle Fixture Insert each pole into fixture-hole Poles for BG400S Poles for BG700S Air intake hose.
How to Use a Laptop Computers. Unplug the laptop from the computer on wheels!
DS200 PROCEDURES SPEAKER TOUCH SCREEN DISPLAY
375, 375XL 1¼” -2”. Modification Overview  Production of the 1¼” -2” 375 began in 2004 and is current.  The lead free version 375XL was introduced in.
RPZ, RPZE ½”-2”. Modification Overview  Production of the model RPZ began in  The lead free version ( RPZE ) was introduced in 2002 and is current.
450 4”-10”. Modification Overview  Production of the 4” - 10” sizes began in  The lead free version (XL) was introduced in 2011.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
NN-CS596S Steam Microwave Oven. NN-CS596S Oven Specification.
MSA Passport  Personal Alarm Combustible gases and vapors Oxygen enriched Oxygen deficient Specific Toxic gases Alarm levels are set at the factory.
How to SWIVl: Using a Gen 2 SWIVL RObot
Apparatus Setup Jason Quill Eric Richardson.
PLC Millenium II Application Notes NEUSS November 2004.
14 Refrigerant Recovery, Recycling, and Recharging.
Step 1: Load paper Before you replace the ink cartridges and begin the alignment process, load paper in the printer. 1) Raise the input tray. 2) Remove.
WASHERS.
Automatic Test Station for GasAlertClip Extreme Portable H2S Monitors
Accu-Vote Tabulator Preparation
Engine Oil Changes.
Engine Oil Changes.
How to set up the Flexmort CuddleCot™
“Lesson – Installing Material Cartridge and Printing a File”
Engraving and Assembly
Filling of SAPPHIRE 25 & 42 Bar Systems (TFPP Hardware)
How to use a Heart Rate Monitor
Basic Operational Instructions
Quanta FIB Basic Training Eucentric, Pt Deposition, and Trenching
Presentation transcript:

23-Aug-06 mgbersch Plasma Cleaner Instructions for Use

23-Aug-06 mgbersch Fischione 1020 Plasma Cleaner

23-Aug-06 mgbersch General Most of the cleaning process with the 1020 are automatic. The process is started by entering a cleaning time. Once the process starts the specimen chamber will automatically pump and initiate plasma cleaning. The chamber will remain under vacuum until vented by the user. VENTING TAKES 3 – 4 MINUTES. TURBO PUMP MUST SPIN DOWN.

23-Aug-06 mgbersch Gas Supply Make sure the gas supply is on and there is gas. Gas is an Argon – Oxygen mixture. NOTE, just check the gauge. Do NOT adjust ANY valves.

23-Aug-06 mgbersch Check Control Panel Normally the specimen holder will be under vacuum. First check the control panel. If the “HIGH VACUUM” light is illuminated, you must vent the specimen chamber.

23-Aug-06 mgbersch Venting the Specimen Chamber Press VENT on the control panel. The VENTING LED will illuminate. It takes 3 – 4 minutes to vent the chamber.

23-Aug-06 mgbersch Chamber at Atmosphere Wait until the ATMOSPHERE LED is illuminated before opening chamber.

23-Aug-06 mgbersch Remove the plug After the chamber is vented, remove the plug from the TEM specimen port. Place the plug in the plastic bag on top of the plasma cleaner. The chamber is now ready for insertion of the TEM specimen holder.

23-Aug-06 mgbersch Insert TEM Specimen Holder Insert the TEM specimen holder into the chamber. The specimen holder may come to a stop but may not be fully inserted (see image). Do not push on the specimen holder at this time. WAIT.

23-Aug-06 mgbersch Set Cleaning Time Using the number pad on the control panel input the cleaning time. Cleaning time for most TEM specimens is 30 sec to 5 minutes. Press SET to start the pump down and cleaning cycle.

23-Aug-06 mgbersch Check Holder and Clean Cycle When the pumping cycle starts the holder should then move into the specimen chamber. CHECK THIS. When cleaning is underway, the gas mixture will luminesce. This can be observed through the window.

23-Aug-06 mgbersch Clean cycle end and vent The timer will count down as the cleaning cycle continues. At zero cleaning will end but the chamber remains under vacuum. To Vent, press VENT. REMEMBER: 3 to 4 minutes to vent chamber.

23-Aug-06 mgbersch Shut Down # 1 Remove the holder from the specimen chamber. Replace the Plug

23-Aug-06 mgbersch Shut Down # 2 Press PUMP to pump down the chamber. Chamber is left under vacuum Wait and make sure the chamber returns to HIGH VACUUM

23-Aug-06 mgbersch APPENDIX An accessory is available for inserting SEM stubs (FEI type). A vacuum pumping station for TEM holders is also avaible.

23-Aug-06 mgbersch Remove the TEM Port The TEM port must be removed before the SEM specimen holder can be placed in the cleaning chamber. Unscrew the black retaining ring and remove. Take out the TEM port and place on a clean surface. Be careful of, and check the large O-ring

23-Aug-06 mgbersch Insert the SEM specimen holder Insert the SEM specimen holder. Be careful of the large O- ring. The holder sits flush in the opening when fully inserted.

23-Aug-06 mgbersch High Vacuum Docking Stations TEM holders can be kept under vacuum in the TEM Docking station. To use: –Contact CAF personnel.