SupaRule Cable height meters Presented by: Gary Carroll Director Feb 2004.

Slides:



Advertisements
Similar presentations
EPOCH 1000 Series Procedure Conventional Angle Beam Calibration
Advertisements

Product Presentation. WHAT IS IT? Product Presentation.
(GET FAMILIAR WITH EQUIPMENT)
Suparule Cable Height Meter: A guide
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
1 MIAS Measuring Is Always Simple Using S2 Laser Distance Meter Your best Measuring partner.
WIRED TYPE MULTI ZONE FANCOIL CONTROL SYSTEM MODEL : WSF- 700 SYSTEM
ELECTRONIC GUIDING CANE FINAL PRESENTATION Students : David Eyal Tayar Yosi Instructor : Miki Itzkovitz Technion – Israel Institute Of Technology Electrical.
TLA. Replacing The Battery On the Back of the pager press in this button while moving the door away from the pager, then lift up. On the Back of the pager.
① The output signal of a room thermostat is ON or OFF according to changes of room temperature ② The power supply to a motorized valve is ON or OFF according.
They’re fast, they’re easy to use, and they fit on your tool belt. Why the Fluke 416D and Fluke 411D? Use Fluke distance meters to quickly determine an.
1 Check all equipment is included before returning. If you have an accident or the equipment is damaged or you need support please contact Blaize
Photoelectric Beam Detector NRTS Series. 2 1. Outline Dual beam detector NRTS series is a part of Red Barrier series. * 30m 60m 90m (Outdoor) range *6.
Photoelectric Beam Detector NRTM Series. 2 1. Outline Dual beam detector NRTM series is a part of Red Barrier series. * 30m 60m 90m (Outdoor) range *Selectable.
Artemis Lite Fault Finding FAQ’s
Tool removed during cycle Fault #2 Conditions for setting Tool cocked prox switch goes open during cycle AND force on load cell drops below limit in fault.
Calibration Procedure.  A winch calibration is completed via a linear interpolation between 2 points.  Requires 2 references  Known lower weight 
© 2008 Masimo Corporation Includes a review on Carbon Monoxide Poisoning For Emergency Responders V.8 1 May 2011 Monitoring CO Poisoning with the Rad-57.
The Edge™ Handheld Lactate Analyser
EPOCH 1000 Series Procedure Phased Array DGS/AVG
EPOCH 1000 Series Procedure Phase Array Straight Beam Calibration
1Rugby 55 Presentation – January 2007 The Rugby 55 User Presentation.
CIVL 102 Leveling Lab Briefing on Field Work. Instrument error  suppose Instrument error  suppose line of sight not truly horizontal as telescope is.
1 Lab Equipment. 2 TopicSlides DC Power Supply3-4 Digital Multimeter5-8 Function Generator9-12 Scope – basic controls13-20 Scope – cursors21-24 Scope.
NorCal Tech 2005 Technical Conference
Data Logging GCSE ICT. Learning Intentions: To explore the tern data logging. To explore the concept of analogue and digital data and the need for conversion.
Water Quality Supplies Waste bottle 1413 solution pH 10 solution pH 4 solution Solution cups Water sample cup Hanna Meter.
GPS. Meet the Bad Elf GPS Pro The Bad Elf GPS Pro offers the first Apple approved GPS with an informative user interface.
Types of cameras, parts of the camera
GPS & Total Station Basics
Leica Lino Product Family Accurate, self-leveling point and line lasers Please insert a picture (Insert, Picture, from file). Size according to grey field.
Ultrasonic Sensor Made By: 1.Hadeer Radwan 2.Alaa Mustafa 3.Amany Amr.
TRANSMILLE PATs The New Alternative To Fast, Easy & Efficient Portable Appliance Testing.
SB-N : Technical Workshop 1. General Presentation QUICK and EASY settings Alignment feedback Buzzer and Leds indication One person to set-up the columns.
Cypress-Fairbanks I.S.D. 04/04/05 PC6 Word Processor Training Assistive Technology
EZ-3 ECG. Thank you for your interest in Futuremed’s EZ-3 ECG. Like other EZ-3 users, we are confident you will enjoy this model ideal for obtaining sharp.
“We Bring Engineering to Life” U.S. Tobacco GAP – Barn Testing Procedure.
1Rugby 50 Presentation – January 2007 The Rugby 50 User Presentation.
Election Commission of India
TouchIT Board Training.
White Knight Tap Locator HJ Arnett Industries, LLC Portland, OR
MODERN SURVEY (FAMILARISATION WITH EQUIPMENTS). Modern equipments EDM – Electronic distance measurement eqp. EDM – Electronic distance measurement eqp.
Echolocation II Sonar Radar Who launches first? Sonar “Ping” Who finds the other first? SONAR in ships works like echolocation in whales and bats. The.
 PREPARED BY: 1.Sindha.Rinku.R 2.Trivedi.Hasti 3.Kamdar.Karan  GUIDANCE BY : ASHISH RATHOD (ASST.PROF.) Modern tools of Surveying & Mapping.
MOBA Mobile Automation AG Kapellenstr Limburg / Germany Telefon: Telefax:
1 THE VICTOR READER WAVE ● Plays DAISY books as well as music and books on MP3 or audio CD ● Powerful navigation features ● Go directly to any page number.
EPOCH 1000 Series Procedure Phased Array Angle Beam Calibration
EGA Technical World Leaders in Combustion Management Solutions Mk7 EGA.
Confidentiel –Usage interne Presentation RayCAm CA 1884.
Miscellaneous Test Equipment Combustion, Tachometers, Hygrometers The materials included in this compilation are for the use of Dwyer Instruments,
3M Touch Systems Mark Roberts Field Application Engineer August 14, 2002 Touchscreen Integration and Troubleshooting.
Service Section Technical Training December 2005.
Unit 1 Lecture 4.
DS200 PROCEDURES SPEAKER TOUCH SCREEN DISPLAY
Forge Echo Introduction. Base Package Getting to know the device G – Sensor Calibration F4 Key Assignment Application F4 Distance Application F4 Height.
Tool Removed During Cycle Fault #2 Conditions for Setting Tool cocked prox switch goes open during cycle AND force on load cell drops below 5 lbs. Active.
Sonic / Ultrasonic Anemometers
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
Using a Digital Data Logger North Carolina Immunization Program (NCIP)
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
CA05FS Owner’s Manual Fuel Cell Technology Breath Alcohol Tester.
WHAT’S NEW IN TRIOS 2014.
Powertap User Guide.
Data Logging GCSE ICT.
Data Logging GCSE ICT.
Commercial Stainless Steel Freezers
Alcohol Screening Program
Exhaust gas intake to cabin air.
724 Temperature Calibrator
Instruments & Electrical Measurements Lecture 4
Presentation transcript:

SupaRule Cable height meters Presented by: Gary Carroll Director Feb 2004

Using the SupaRule Cable Height Meter

Ultrasonic handheld meter for measurement of Cable height Cable sag Overhead clearance to ground. Safest method for cable height measurement. By eliminating cable contact and the use of heavy fiberglass poles Cable Height Meter

Key advantages: Safety: No contact with conductors One simple solution: One button-one man operation Easy to use. Efficient use of resources. Cable Height Meter

Competition Telescopic rods: Cumbersome, heavy to carry, break easy. Accuracy depends heavily on experience of user. Frequent calibration required. Laser Difficult to target conductors. Accurate units cost €3,000- €5,000

Cable Height Meter Theory of operation Sends (ultra) sound wave to target Measures time to echo Calculates distance based on speed of sound Adjusts for air temperature

1.Select: M(metric) or I (imperial) at the back of unit. 2.Set the CAL mode switch to the WIRE position. 3.Press the ON key to power on 4.Stand directly underneath the conductors(s) to be measured. 5.Press the MEASURE Key to take measurement 6.Press the READ key to display each of the stored wire height differences (Stored Measurements). CHM Operation

Newer CHMs: Same Functions/ Different Implementation Older CHM had a Clear (C) button, On newer models, to clear screen press Read (W: wire) and Measure (+) buttons together. Older CHM had a battery check button. Newer models have a low battery signal appearing on screen, if battery is low. Older units used (M) measurement to select differences between wires; newer models use READ button. Taking a reading: Press Measure (+). Unit automatically captures all wires within the ultrasonic cone. Read measurement by scrolling down the Read (W for wire) button, from 1 (lowest wire) to 2 (spacing in between cable 1 and 2), 3 and up to 6 wires, provided conductors are stacked above each other. If taking reading of wires parallel to each other, a number of separate measurement need to be taken. CHM Operation

Specification Accuracy:0.5% ± 2 digits Minimum gap between wires:150 mm Operating Temp. Range:-10 °C to 40 °C Battery Life (9V Alkaline type): 50,000 measurements Auto power off delay: 3 minutes Serial number location: underneath battery. Models available: 3 wires: CHM wires: CHM to 15 m (=10 to 50ft) Standard units: CHM 300/600 3 to 23 m (= 10 to 75ft) Model “E”: CHM 300/600E Cable Height Meter

This indicates a “poor target”, and normally happens when the cables are moving due to wind, etc. Screen is blank Check battery is inserted correctly. Open battery door on the bottom rear of the unit. The battery is inserted with the terminals inwards. The + and - symbols on the battery should correspond with the + and - symbols on the inside of the battery compartment. Unit does not measure all wires Ensure that horizontal distances between wires are within the sonic beam. If the display shows Incorrect readings Ensure CAL mode switch is on correct position, i.e. WIRE for cable height measurement, and WALL for horizontal distance measurement. Ensure no walls or similar obstructions within 2 meters either side of unit, as reflections from these can interfere with correct operation. Cable Height Meter

Do: Position the unit on the ground, directly underneath the conductor to be measured. Align the unit in the direction of the conductor, with the cone, pointing towards the conductor. Keep the unit dry; if wet, leave upside down in a warm area Don’t: Avoid clutter around conductor to be measured Avoid water, rain, snow, humidity. Avoid sudden changes of temperature. Cable Height Meter

Warranty: 12 months from purchase date. Calibration: The CAL mode switch allows the user to periodically check the unit, to ensure it is still operating within specification. Repair: SupaRule offers repair at a standard rate. Quick turn around time - less than 1 week from receipt of unit. Return rate: Under warranty - better than 0.5% / year; typically 0.2% Product Life years Date Distance Measured SupaRule offers calibration certificate at €163 / unit. Cable Height Meter

Complementary products: Dynamic Target (DT80) with Model CHM 300DT Tripod Leather case Cable Height Meter

Distance Measurement Thank You Feb 2004