Postal Responsibility/Contractor responsibility 1.Serial number of fire extinguisher 2.Number found on fire extinguisher and panel 3.Date extinguisher.

Slides:



Advertisements
Similar presentations
OSHA Office of Training and Education
Advertisements

F&T Inc. OVERHEAD CRANE SAFETY.
East Carolina University Compressed Gas Safety Training Program
What to look for, What to correct, How it should look,
 Without reference, identify principles relating to Fixed Radiological X-RAY PM with at least 70 percent accuracy.
1926 Subpart J Establishes the requirements for welding and cutting in the construction industry Establishes requirements for equipment, fire protection,
PORTABLE FIRE EXTINGUISHER TRAINING Section Montana Department of Labor & Industry Occupational Safety and Health Training Institute.
Lift Safety EZ Up 10’ Lift. Training Objectives  Identify lift hazards  Understand OSHA equipment requirements  Know how to inspect equipment  Take.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Stairways and Ladders 1926 Subpart X - Stairways and Ladders
Walking-Working Surfaces
Ladder Safety and Aerial Lifts
Atlantic Beach Fire Department Presents: For Business Employees and the General Public.
OSHA Office of Training & Education
Climbing the Ladder to Safety
OSHAX.org - The Unofficial Guide to the OSHA1 Stairways and Ladders.
Stairways and Ladders.
Walking-Working Surfaces: Preventing Falls.
1 Telecom Cabling Ladder safety. 2 OSHA Office of Training & Education ation Telecom Cabling Stairways and Ladders.
Cranes, Hoists and Truck Hoists
CLASSES OF FIRE Class “A” – combustible materials
HOT WORK PROCEDURES Welding and Hot Work, such as brazing or grinding present a significant opportunity for fire and injury. CCR Title 8 Sub Chapter 7,
LADDER & STAIRWAY SAFETY
How to create... A Fire Evacuation Plan.
Fire Protection John Giefer. Statistics In the Drilling Industry In the Drilling Industry 25% of all inspections found violations of (21 inspections.
Portable Fire Extinguishers Selection and Placement University Safety Council April 19, 2006 Steven G. Triebold Fire Prevention and Protection Program.
Getting Credit and Certificate
Water Supply.
Emergency Action Plans
Business Owners and Managers and the Fire Code
Fire Detection and Suppression Chapter 1 Fire Extinguishing Agents and Portable Fire Extinguishers.
Means of Egress and Fire Protection
Safety Training Presentation
International Fire Door Inspector Association Presents New Annual Fire Door Inspections NFPA 80 – 2007, 2010, 2013 Standard for Fire Doors and Other Opening.
Electrical Safety.
Fire Safety and Prevention Plan
Georgia Tech Safety and Health Consultation Program
15 Water Supply. 2 Objectives Describe the sources of water for a municipal water supply system. Explain the purpose of a water treatment facility. Describe.
Hot Work Procedures Fire Control. Cutting and Welding Where practicable all combustibles shall be relocated at least 35 feet from the work site Where.
Means of Egress and Fire Protection. Introduction Fires and explosions kill more than 200 and injure more than 5,000 workers each year There is a long.
OSHA’s Most Frequently Cited Violations Hazard Communication 29 CFR (f)(5)(ii) states that all chemical containers must be labeled.
Exit Routes and Fire Protection
2009 OFPC INSPECTION SUMMARY of VIOLATIONS We Need Your Help for the 2009 Inspection!
Click to edit Master text styles – Second level Third level – Fourth level » Fifth level Click to edit Master text styles – Second level Third level –
Fire Extinguisher Inspection
Subpart F - Fire Protection & Prevention ( ) Flammables/combustibles - Approved containers Fire protection program/equipment 2A fire extinguishers.
Presented by John Lewandowski and Mike Larabel Inspection, Testing, and Maintenance of Kitchen Hood Systems Michigan Fire Inspectors Society Winter Educational.
Recognizing and correcting hazards
Transfer Station Safety OR WORKER AND PUBLIC RISK.
OSHA Office of Training & Education
Manufacturing 120 Industrial Safety and CPR
Manufacturing 120 Industrial Safety and CPR Bruce Poole Sean Howard (IBEST Instructor)
Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection.
Hearing protection in excess of ________ decibels requires protection
Wire Rope Inspection Look for:
Types of Protection Introduce the module. Trenching & Excavations Continuing Education Third Quarter 2017 Session 2.
Learning Objective 3 Define the ratings in a portable fire extinguisher rating system.
OSHA Most Frequently Cited Serious Violations
Fire Extinguisher Inspections.
Fire Safety and Prevention Plan
CDL Training.
Overhead and mobile crane safety
Most Frequently Cited Serious Violations
East Carolina University Compressed Gas Safety Training Program
Fire Extinguisher Monthly Inspection
Electrical Safety.
F&T Inc. OVERHEAD CRANE SAFETY.
Essentials of Fire Fighting Maintenance and Testing Responsibilities
00 - Fire Extinguisher Refresher Training
Hot Work Procedures Fire Control.
Presentation transcript:

Postal Responsibility/Contractor responsibility 1.Serial number of fire extinguisher 2.Number found on fire extinguisher and panel 3.Date extinguisher was installed at this location 4.Completed by contractor conducting annual inspection 5.Completed by contractor when extinguisher is recharged 6.Completed by contractor when hydrostatic test is conducted 7.Completed by postal employee assigned to monthly PM route Retention: 5 years Source: MS-56, 444 PS Form 4705 Completion Requirements SAFETY COMPENDIUM – FIRE EXTINGUISHERS

Postal Responsibility The following elements constitute the monthly fire extinguisher check (monthly check to include fire extinguishers in vehicles): 1.Verify the fire extinguisher is not blocked by equipment or other objects that could interfere with access in an emergency. 2.Inspect the shell for corrosion, mechanical damage (denting or abrasion), paint condition, presence of repairs (welding, soldering, brazing, etc.), and broken hanger attachment concealing surface damage (nicks or corrosion). 3.Inspect the nameplate for illegible wording, corrosion, and loose plate. Verify extinguisher has pictographic type label. 4.Inspect the nozzle for damage, deformation, cracks, blocked openings, damaged threads (corroded, cross-threaded, or worn), and aging (brittleness). 5.Inspect hose assembly for damaged hose (cut, cracked, worn, or plugged), damaged couplings or swivel joint (cracked or corroded), damaged threads (corroded, cross threaded or worn), and inner tube cut at couplings. 6.Ensure the valve-locking device is in place and inspect for damage (bent, corroded, or binding). 7.Check extinguisher pressure gauge, tap gauge lightly to determine if pointer is stuck or jammed. Inspect for missing pointer; missing, deformed, or broken crystal; illegible or faded dial; corrosion, dented case, and damaged crystal retainer. Read gauge. If not in operating range, remove, replace, and submit extinguisher for recharging or hydrostatic test. 8.Ensure that seal or tamper indicator is not missing or broken. Replace extinguisher if seal or tamper indicator is missing or broken. 9.Complete the applicable portions of Form 4705, Fire Inspection Tag. Inspection Record Retention: 5 years Monthly Portable Fire Extinguisher Check SAFETY COMPENDIUM – FIRE EXTINGUISHERS 2 4/5 7 6/8 3

Fire Extinguisher Mounting SAFETY COMPENDIUM – FIRE EXTINGUISHERS Visible from this side Solid red rectangle, 6 inches beyond each side of extinguisher. Signage or panel above extinguisher 23 Extinguishers must be available when needed and employees must not be subjected to injury when obtaining an extinguisher. The locations of extinguishers must be immediately visible from several different directions. Access to extinguishers must be maintained at all times. Floor areas below the extinguisher and their approaches must be kept free of materials, and red lines must be applied to the floor. Location numbers must be applied to all extinguishers and the red background where the extinguisher is mounted to ensure accurate service and adequate inventory records. In multi-floor structures, the extinguisher number may be prefixed by the floor designation. Fire extinguishers having a gross weight not exceeding 40 pounds must be installed so that the top of the fire extinguisher is not more than 5 feet above the floor. The clearance between the bottom of the fire extinguisher and the floor must be at least 4 inches. Portable fire extinguishers must be installed securely on the hanger, or in the bracket supplied by the extinguisher manufacturer, or in a bracket approved for such purpose, or placed in cabinets or wall recesses. If the possibility of damage to an extinguisher exists from rolling equipment, hampers, trucks, etc., suitable guards must be provided. A solid red rectangle must be applied to the wall behind the extinguisher, extending at least six inches beyond each side of the extinguisher. If the extinguisher is not readily visible from several directions, an additional rectangle at least 12 inches wider than the extinguisher must be painted on the wall above the extinguisher at least 12 feet from the floor. In USPS workrooms the location of column mounted extinguishers is indicated by a solid red band extending six inches above and below the extinguisher, encircling the column. If the location of the extinguisher cannot be immediately determined, or is not readily visible from several directions, a red band at least 6 inches wide must be applied to the column at least 12 feet from the floor, encircling the column. Use additional directional signs or triangular sign, where necessary. Distribute portable fire extinguishers, regardless of size or class, so that the maximum travel distance to any extinguisher does not exceed 50 feet. This includes elevated work platforms, conveyor walkways, and catwalks. Selected locations should have the following characteristics: (1) Provide uniform distribution (2) Provide easy accessibility (3) Be relatively free from blocking by storage and equipment, or both (4) Be near normal paths of travel (5) Be near entrance and exit doors (6) Be free from the potential of physical damage (7) Be readily visible (8) Be installed on a floor-by-floor basis Reference: MS-56