Heating and Air Conditioning I

Slides:



Advertisements
Similar presentations
100% Outside Air and Dehumidification Management
Advertisements

HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Introduction Enthalpy Wheel
Estimates of Dry Air Requirements of the P0D Lets assume a simple model of input dry air (from the membrane filter) with a relative humidity that mixes.
Psychrometric Properties of Moist Air
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY. “Air conditioning is the control of the humidity of air by either increasing or decreasing its moisture content.
MOLLIER DIAGRAM.
Lecture 8 Saturated Adiabatic Processes Phase Changes Liquid Gas (Vapor) Energy absorbed Energy released Solid (Ice) melting evaporation deposition freezing.
Psychrometry HVAC CNST 305 Environmental Systems 1 Dr. Berryman 5cIndoor Air Quality, Psychometrics; Dry and Wet Bulb; Enthalpy; Condensation; Dew Point.
Psychrometric Chart Basics
10/28/97A F Emery1 PSYCHROMETRICS and ELEMENTARY PROCESSES (SI Units) Ashley F. Emery University of Washington.
Examples on using Psychart -- The digital psychrometric software
ARCH-432 Dew Point Saturation and Psychometrics. Attendance Who is typically referred to as the “Father of Cool”? (hint: generally credited with developing.
Psychrometrics.
Gas – Vapor Mixtures & Air – Conditioning
Building Energy Efficiency
Bernoulli’s Theorem for Fans PE Review Session VIB – section 1.
PSYCHOMETRICS INTRODUCTION INDEXES PSYCHOMETRIC CHART INTRODUCTION:
Heating and Air Conditioning I
Pump Affinity Laws. P. 100 of text – section 4: vary only speed of pump P. 100 of text – section 5: vary only diameter P. 106 of text – vary BOTH speed.
Core Principles Bernoulli’s theorem for Fans
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
Psychrometry HVAC CNST 305 Environmental Systems 1 Dr. Berryman 5cIndoor Air Quality, Psychometrics; Dry and Wet Bulb; Enthalpy; Condensation; Dew Point.
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
Objectives Learn more about Psychrometrics
Department of Mechanical Engineering ME 322 – Mechanical Engineering Thermodynamics Lecture 35 Analysis of Air Conditioning Processes.
Thermal Analysis and Design of Cooling Towers
Lecture Objectives: Model HVAC Systems –HW3 Asignemnet Learn about eQUEST software –How to conduct parametric analysis of building envelope.
Conditioning of Moist Air
Objectives Learn basics about AHUs Review thermodynamics - Solve thermodynamic problems and use properties in equations, tables and diagrams.
Ductless Heat Pumps Sizing Example
Important variables Water: Air: Conversion:
10/28/97A F Emery1 PSYCHROMETRICS and ELEMENTARY PROCESSES (English Units) Ashley F. Emery University of Washington.
Lecture Objectives: Specify Exam Time Finish with HVAC systems –HW3 Introduce Projects 1 & 2 –eQUEST –other options.
Objectives Define psychrometric quantities Continuation from previous class Draw psychrometric processes Relate psychometric variables to human comfort.
Ideal Gas Mixture and Psychrometric Applications
A Trane Air Conditioning Clinic Psychrometry Air Conditioning Clinic TRG-TRC001-EN © American Standard Inc
Objectives Analyze processes in AHU and buildings.
A C M V PSYCHROMETRY (A Review) Dr. Khairul Habib.
1 Refrigeration Technology wu wei-dong Chapter9. Psychrometry and Air Processes.
Introduction to Energy Management. Week/Lesson 5 Psychrometrics: The Properties of Air.
Objectives Ventilation analysis with HOP Human exposure/IAQ Ventilation and energy.
Moisture Measurement. Sensible heat and Latent heat.
Objectives Psychometrics Psychometrics of AHU.
HUMIDITY AND AIR CONDITIONING
Moisture  There are several methods of expressing the moisture content (water in vapor form) of a volume of air.  Vapor Pressure: The partial pressure.
HCB 3-Chap 19A: All-Air Systems_Single Zone 1 Chapter 19A: ALL-AIR SYSTEMS: SINGLE ZONE AND SINGLE DUCT Agami Reddy (July 2016) 1)Introduction and common.
CHAPTER 13 Gas – Vapor Mixtures and Air-Conditioning.
Design & Analysis of Psychrometric Processes Various ways of Generating A Comfort… BY P M V Subbarao Associate Professor Mechanical Engineering Department.
Maria’s Restaurant Chapter 2 Section 9
SNS COLLEGE OF ENGINEERING Coimbatore-107 Subject: Thermal Engineering
Chapter 14 Gas-Vapor Mixtures and Air-Conditioning Study Guide in PowerPoint to accompany Thermodynamics: An Engineering Approach, 8th edition.
Moisture Measurement.
Introduction to Food Engineering
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Doug Jefferson, Business Development Engineer
PSYCHOMETRICS INTRODUCTION INDEXES PSYCHOMETRIC CHART INTRODUCTION:  PSYCHOMETRICS IS THE STUDY OF MOIST AIR.  THE PSYCHOMETRIC CHART IS A GRAPHIC REPRESENTATION.
Psychrometric Chart Basics. Basic Concepts Saturation Line.
Psychrometric Processes
HCB 3-Chap 19A: All-Air Systems_Single Zone
Psychrometry & Air-conditioning
VAV DESIGN FOR IMPROVED INDOOR AIR QUALITY
Chapter 13B: PSYCHROMETRIC MOIST AIR PROCESSES
Psychrometric analysis Revision of principles - Central plant
Lecture Objectives Review: Psychrometrics (chart and quantities)
Lecture Objectives Learn about Psychrometric Chart Quantities
Announcements Exam 1 Next Class (Thursday, March 14th):
Objective Revie the Cooling Cycle Learn about air distribution systems
Maria’s Restaurant Chapter 2 Section 9
Presentation transcript:

Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference material For ME 421 John P. Renie Adjunct Professor – Spring 2009

Chapter 3 – Basic HVAC Calculations Applying Thermodynamics to HVAC Processes Looking at a simplified (but complete) air-conditioning system Terminology: qsensible, mwater, qL, hw, solar gains Look at first law of thermodynamics (energy) and conservation of mass Air is removed from the room, returned to the air-conditioning apparatus where it is reconditioned, and then supplied again to the room. Many cases, it is mixed with outside air required for ventilation Outdoor air (o) is mixed with return air (r) from the room and enters the apparatus at condition (m) Air flows through the conditioner and is supplied to the space (s). The air supplied to the space absorbs heat qs and moisture mw, and the cycle continues.

Chapter 3 – Basic HVAC Calculations Applying Thermodynamics to HVAC Processes

Chapter 3 – Basic HVAC Calculations Applying Thermodynamics to HVAC Processes

Chapter 3 – Basic HVAC Calculations Applying Thermodynamics to HVAC Processes

Chapter 3 – Basic HVAC Calculations Absorption of Space Heat and Moisture Gains AC usually reduces to determining the quantity of moist air that must supplied and the condition it must have to remove given amounts of energy and water from the space to be withdrawn at a specified condition. Sensible heat gain – addition of energy only – not wrt water

Chapter 3 – Basic HVAC Calculations Heating or Cooling of Air – without moisture gain or loss – straight line on psychrometric chart since humidity ratio is constant

Chapter 3 – Basic HVAC Calculations Cooling and Dehumidifying Air Moist air brought down below its dew point temperature – some of the water will condense and leaves the air stream Assume condensed water is cooled to the final air temperature before draining from the system

Chapter 3 – Basic HVAC Calculations Cooling and Dehumidifying Air

Chapter 3 – Basic HVAC Calculations Cooling and Dehumidifying Air Moist air brought down below its dew point temperature – some of the water will condense and leaves the air stream Assume condensed water is cooled to the final air temperature before draining from the system Cooling and dehumidifying process involves both sensible heat transfer and latent heat transfer where sensible heat transfer is associated with the decrease in dry-bulb temperature and the latent heat transfer is associated with the decrease in humidity ratio.

Chapter 3 – Basic HVAC Calculations Heating and Humidifying Air

Chapter 3 – Basic HVAC Calculations Adiabatic Mixing of Two Streams of Air

Chapter 3 – Basic HVAC Calculations Adiabatic Mixing of Moist Air with Injected Water

Chapter 3 – Basic HVAC Calculations Moving Air

Chapter 3 – Basic HVAC Calculations Approximate Equations Using Volume Flow Rates Since volumes of air change – need to make calculations with mass of dry air instead of volume. But volumetric flow rates define selection of fans, ducts, coils, etc. Use volume while still considering mass by using volume rates based on standard air conditions Dry air at 20 oC and 101.325 kPa (68 oF and 14.7 psia) Density is 1.204 kg/m3 (0.075 lb/ft3) – dry air Specific volume is 0.83 m3/kg (13.3 ft3/lb) – dry air Saturated air at 15 oC has about same density and volume Need to convert actual volumetric flow conditions to standard Say you need 1,000 cfm outside air rate at standard conditions Outside measured at 35 oC dry bulb and 23.8 oC wet bulb corresponding to a specific volume of 14.3 ft3/lb. Then, the actual flow rate would be 1,000 (14.3/13.3) = 1,080 cfm 1,000/13.3 = 1,080/14.3 = mass rate (lb/min) of moist air

Chapter 3 – Basic HVAC Calculations Sensible heat gain corresponding to the change of dry-bulb temperature for a given airflow (at standard conditions)

Chapter 3 – Basic HVAC Calculations Latent heat gain corresponding to the change of humidity ratio W for a given airflow (at standard conditions). The latent heat gain in Watts (Btu/h) as a result of a difference in humidity ratio DW between the incoming and leaving air flowing at standard conditions.

Chapter 3 – Basic HVAC Calculations Total heat gain corresponding to the change of dry-bulb temperature and humidity ratio W for a given airflow (at standard conditions). The total heat gain in Watts (Btu/h) as a result of a difference in enthalpy Dh between the incoming and leaving air flowing at standard conditions.

Chapter 3 – Basic HVAC Calculations Total heat gain corresponding to the change of dry-bulb temperature and humidity ratio W for a given airflow (at standard conditions).

Chapter 3 – Basic HVAC Calculations Single-Path Systems Simplest form of all-air HVAC system serving a single temperature control zone Responds to one set of space conditions, where conditions vary uniformly and the load is stable. Schematic of system – return fan necessary under certain conditions of Dp. Need for reheat – necessary to control humidity independent of the temperature requirements. Equations for single-path systems – air supplied must be adequate to take care of each room’s peak load conditions. Peak loads may be governed by sensible or latent room cooling loads, heating loads, outdoor air requirements, air motion, and exhaust. – let us look at each of these loads and what air volume is required to satisfy these demands.

Chapter 3 – Basic HVAC Calculations Single-Path Systems - schematic

Chapter 3 – Basic HVAC Calculations Single-Path Systems – equations for supply air

Chapter 3 – Basic HVAC Calculations Single-Path Systems – equations for supply air

Chapter 3 – Basic HVAC Calculations Single-Path Systems – supply air for ventilation Supply air for ventilation – needed when the amount of outside air is not adequate Supply air not adequate for the amount of exhaust makeup required – no return air comes from the room and entire volume of make-up ventilation air becomes an outside air burden to system Desired air exchange rate not satisfied – supply air is determined Desired air movement not satisfied, based on area index parameter, K. Each of the above conditions are used at different times – Case 1 when outside air governs, Cases 3 and 4 when air movement governs, and Case 2 when exhaust governs.

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Example Problem 3-3

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Example Problem 3-3

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Example Problem 3-3

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Example Problem 3-3

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Cycle Diagram

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Cycle Diagram Each state point is identified both in summer and winter Change of Dt is result of sensible heat loss or gain, qS Change in DW is result of latent heat loss or gain, gL All return air is assumed to pass from the room through a hung-ceiling return air plenum Supply air CFMS at the fan discharge temperature tsf (summer mode) absorbs the transmitted supply duct heat qsd and supply air fan velocity pressure energy qsf,vp thereby raising the temperature to ts

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Cycle Diagram Room supply air absorbs room sensible and latent heat qSR and qLR along the room sensible heat factor (SHR) line s-R, reaching the desired room state, tR and WR.

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Cycle Diagram Room (internal) sensible loads which determine the CFMs consist of:

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Cycle Diagram

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Psychrometric Representation

Chapter 3 – Basic HVAC Calculations Single-Path Systems – Psychrometric Representation

Chapter 3 – Basic HVAC Calculations Single-Path System - Psychrometric Representation

Chapter 3 – Basic HVAC Calculations Single-Path System – Sensible Heat Factor (Ratio) Sensible heat factor (ratio), SHF or SHR, is the ratio of sensible heat for a process to the total of sensible and latent heat for the process. The sensible and latent combined is referred to as the total heat On psychrometric chart, the protractor provides this ratio and may be used to establish the process line for changes in the conditions of the air across the room or the conditioner on the chart The supply air to a conditioned space must have the capabilty to offset both the room’s sensible and latent heat loads. Connecting the room and supply points with a straight line provides the sensible heat factor condition. The conditioner provides the simultaneous cooling and dehumidifying that occurs. Horizontal line would be SHF = 0.0 (only sensible) Line with SHF = 0.5 would be half sensible and half latent

Chapter 3 – Basic HVAC Calculations Single-Path System – Final Example

Chapter 3 – Basic HVAC Calculations Single-Path System – Final Example Sensible and latent loads given Room Conditions: (75 oF and 55% RH) – Supply at 58 oF Outside Conditions: 96 oF DB, 77 oF WB and 20% of total flow

Chapter 3 – Basic HVAC Calculations Single-Path System – Final Example

Chapter 3 – Basic HVAC Calculations Single-Path System – Final Example

Chapter 3 – Basic HVAC Calculations Single-Path System – Final Example

Chapter 3 – Basic HVAC Calculations Single-Path System – Final Example

Chapter 3 – Basic HVAC Calculations Single-Path System – Final Example