Salk Institute Mobile Lab Gel Electrophoresis Student Instructions VWR Set up.

Slides:



Advertisements
Similar presentations
Use and Maintenance of Micropipets
Advertisements

Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions Edvotek Set Up 12 groups.
Stage 1: Prepare your plasmids to be cut by restriction enzymes Obtain the plasmids (pKAN and pAMP) P stands for plasmid pKAN = plasmid with antibiotic.
Loading Gels. The Gel Box Electrode Lid Tray to hold gel Connect to power supply.
Using a Micropipette Huntington Gardens July 2013
An Introduction to Microvolumetrics and Pipetting
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions VWR Set Up 12 groups Mira Costa kit.
Use and Maintenance of Micro-pipettes
Measuring Small Amounts Part 1: Using pipets and micropipets.
Cautions! 1. Set pipet volume only within the range specified for that micropipet 2. Do not attempt to set a volume beyond the pipet’s minimum or maximum.
Oct. 22, 2012 Generosity Ludicrous: causing or deserving laughter because of absurdity Do Now: What is a microliter? How many microliter are in one liter?
How to Use a Micropipettor A micropipettor is a precision instrument – expensive (about $200 each), easily broken. Good technique will let it work for.
What are Micropipettors?! We will be using 3 different sizes of micropipettors: ◦ P20 ◦ P200 ◦ P1000 Very expensive and very fragile – USE Responsibly!!!
Micropipette Lab Comparing Precision and Accuracy!
Salk Institute Mobile Lab Gel Electrophoresis Teacher Instructions BioRad Set Up 8 groups Grossmont Kit.
Bellwork What is an SOP? What is its purpose?
Micropipette Tutorial
Glucose test Ms. Ibtisam alaswad Ms. Nour A. taim.
Measuring volumes which are what we scientists call “very, very small”
Introduction to Equipment
Pick up sample 1. 1.Add a tip 2. 2.Push to 1 st stop 3. 3.Lower tip into solution 4. 4.Release plunger Drop off sample 1. 1.Lower tip into tube 2. 2.Push.
AGENDA Who Done It Workshop Continental Breakfast Welcome and Introductions Who Done It Lab Overview of SCBC Resources on MATSC Reserving Your Kit on LARS.
Chapter 8: Density mass volume density = for example, the density of benzene is: g mL.
Salk Institute Mobile Lab Gel Electrophoresis Student Instructions Edvotek set up Salk Institute Mobile Lab.
LABORATORY 1: TOOLS OF THE TRADE LSSI Alum, 2009 Jennifer Muñoz, Del Mar Union School District.
Mastering the micropipette. What is a micropipette? How do you use a micropipette? How can I determine if I’m pipetting correctly?
Introduction to Gel Electrophoresis. Outline How to prepare a gel How to micropipet Practice setting up electrophoresis Discussion viewing of gel –In.
Wildlife Forensics Environmental Study Center. Chinchilla.
CHAPTER 1: Some Tools of the Trade Lab Purpose of Lab 1.1 Become familiar with the small volumes of solutions used in molecular biology Introduce.
How to use a micropipette. When is a micropipette needed? Micropipettes are precision instruments designed to measure and transfer small volumes of liquids.
 Accurately measure and transfer small amounts of liquid  Volumes commonly range from 0.5 – 2000  L (1/millionth of a liter aka )  2-20  L.
1. Which tool would you use for picking up 15 microliter? Which tool for 25 ml? Why? 2. Why do the little test tubes look this way? 3. Answer “Micropipette.
Use of the Labnet Micropipettor. Purpose of the Pipettor Biotechnologists use a pipettor to transfer precise amounts of liquids from one container to.
Science Lab Equipment Henderson Hornets Middle School Science.
Micropipettes Why they are useful How they work How to care for them.
Preparing Solutions.
TOOLS AND TECHNIQUES DNA Fingerprinting. Intoducing the microLiter! A TINY amount…a millionth of a Liter Very difficult to measure because it is SOOO.
Biotech 8/20/13 What pump would you use for a 1 or 2 ml pipet? What pump would you use for a 5 or 10 ml pipet?
Proper Micropipette Technique and Slide Preparation
Use and Maintenance of Micro-pipettes
1 REGIONAL BIOTECH AT THE UNIVERSITY OF TEXAS-PAN AMERICAN BIOSCIENCE EDUCATION FOR THE RIO GRANDE VALLEY.
ABE Labs 1.1 and 1.2 Tools of the Trade. CHAPTER 1: Some Tools of the Trade Lab
An Introduction to Microvolumetrics and Pipetting
Techniques in Molecular Biology 2017 Fall Lecture -2-
Micropipet.
مهارتك الأساسية في معامل التقنية الحيوية
Tools of a Biologist.
Techniques in Molecular Biology 2017 Fall Lecture -2-
Gel Electrophoresis Teacher Instructions BioRad Set Up 12 groups
Use of the Labnet Micropipettor
Metric System and Lab Skills
Use and Maintenance of Micro-pipettes
Introduction to Gel Electrophoresis
(Examples of both horizontal and vertical windows are shown)
Introduction to Gel Electrophoresis
Biotechnology Genetic Testing.
An Introduction to Microvolumetrics and Pipetting
Introduction to Gel Electrophoresis
Measuring volumes which are what we scientists call “very, very small”
Micropipettes.
How to Micropipette 1) Never adjust the volume below 5 uL or above 50uL 2) Never leave pipetter lying on bench with a tip attatched Basic Methods - Set.
Pipette Technique.
Restriction Enzymes.
Serological Pipets Blue Pump 2mL, Green Pump 10mL , Red Pump 25 mL
Do Now How many ul (microliters) is in 1 liter?.
Using the micropipette
Grade Level: Middle School
Do Now How many ul (microliters) are in one liter?
Measurement & Micropipetting
Micropipette Tutorial
Presentation transcript:

Salk Institute Mobile Lab Gel Electrophoresis Student Instructions VWR Set up

Salk Institute Mobile Lab Gel Electrophoresis Student Station Set-up tip container w/tips waste container Micro-pipettor practice sheet in protector foam epi rack w/ 1 food color tube each: orange, green, purple

Salk Institute Mobile Lab How to Use a micro-pipettor Parts of a Micro-pipettor –Make sure a yellow tip is firmly twisted onto the end of the micro-pipettor –Adjust the dispense amount to 5 µl (05.0) by turning the knob at the top Plunger Amount window Eject button Barrel Yellow tip

Salk Institute Mobile Lab How to Use a micro-pipettor Carefully open one of the food color tubes –Don’t let the lid snap back and splash you! To Fill – press down gently with your thumb until you feel the plunger stop. This is STOP 1. While holding the plunger at Stop 1 place the tip into the liquid and release the plunger. This will draw up the precise volume you want.

Salk Institute Mobile Lab How to Use a micro-pipettor To Dispense – press down hard on the plunger, you’ll pass Stop 1 and continue to STOP 2. This will fully eject the volume from the tip. Using your other hand to guide the end of the tip, practice dispensing the 5µl drops –Try to not push down on the plastic sheet - see if you can hold the pipettor tip just above the paper

Salk Institute Mobile Lab How to Use a micro-pipettor Push green button to eject the dirty tip into the waste container and replace with a clean tip Always use a clean tip each time!!

Salk Institute Mobile Lab How to Use a micro-pipettor Ready to load a real gel?

Salk Institute Mobile Lab Loading the gel Load the food color solutions into the wells on your group’s gel Be careful not to poke through the bottom of the wells!