MEP design Mechanical, Electrical, Plumbing. Often separate consultants Can be separate even within a single firm Often performed on a design-build basis.

Slides:



Advertisements
Similar presentations
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Advertisements

BUILDING AIR CONDITIONING
Heating, Ventilating, and Air-Conditioning
CON 4003 Construction Estimating Prof R. V. Locurcio.
Heating, Ventilating, and Air-Conditioning
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
BCT 102 Residential Print Reading Week 10. MEP “Mechanical Electrical & Plumbing” … work coordinates with all other trades *
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Heating, Ventilating, and Air-Conditioning (HVAC)
Department of Energy Energy Savers PowerPoint: Heating and Cooling 4 of 12.
Cold feed to hot water cylinder Sink Basin Bath Drain valve Stop valve WC cistern 100 litre (minimum storage cistern)
Geothermal Retrofit of HVAC Systems
Technology in Architecture Lecture 10 Mechanical Systems Lecture 10 Mechanical Systems.
Components of HVAC System
BASICS OF HVAC Ivy Tech Community College. Definitions – Page 862 HVAC systems are made up of the mechanical equipment such as the furnace, air conditioner,
INTD 51 human environments building systems. heating/ventilation/air-conditioning (HVAC) maintain a comfortable indoor climate control temperature and.
Chapter 6: Thermal Energy
Heat and States of Matter
ASHRAE Presentation: VRF Overview Mitsubishi Electric Presenter: Phone number ©2011 Mitsubishi Electric& Electronics USA, Inc.
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
Heat engines played a key role in the development of the modern industrial world. Steam locomotives were an important early use of the steam engine. Electric.
Thermal energy Ch. 6 mostly. Transferring thermal NRG There are three mechanisms by which thermal energy is transported. 1. Convection 2. Conduction 3.
AIR CONDITIONING (COOLING)
Architectural Drawing Types/Mechanical and Electrical Systems BY: GARRETT PLUMSTEAD AND BRIAN WEST.
HVACR116 – Trade Skills Mechanical Drawings.
November 19, 2013 Agenda 1.Roll 2.PowerPoint titled: Heat Technology 3.Video “Head Rush: Liquid Nitrogen Balloon”
Building Simulation. BMEABMEA uilding odeling nergy nalysis.
Lecture Objectives: Finish with HVAC Systems Discuss Final Project.
Construction and Materials II
Air Conditioning Heating Refrigeration
Heating Systems.
STUDY ON HVAC SYSTEM STUDY ON HVAC SYSTEM
Why can’t heat be converted completely into work?.
Section 1 Temperature and Heat. Kinetic Theory  All objects (even people) are made of particles and atoms that constantly and randomly move. All atoms.
Keeps heat indoors in winter and outdoors in summer – means lower heating and cooling bills Rated by it’s R-value. The greater the R- value the better.
Section 3 Using Heat.
INTRODUCTION TO HEAT LOAD HEAT LOAD12 3 TOPICS COVERED INTRODUCTION DESIGN CONSIDERATIONS DEFINITIONS/CONCE PT/FORMULA THE FORM LOAD COMPONENTS –External.
Building Envelope. Physical separator between interior and exterior spaces – Walls – Floors – Roofs – Fenestrations (any opening in the structure) – Doors.
HEATING AND COOLING SYSTEMS
Chapter 6. Temperature related to the average kinetic energy of an object’s atoms or molecules Thermal energy the sum of kinetic & potential energy of.
A-211 – Reflected Ceiling Plan, First Floor Building 1
Advanced Energy Engineering Technology Modeling Building Energy Systems Session 9: Modeling heating and cooling systems.
Lecture Objectives: Discuss the exam problems Answer question about HW 3 and Final Project Assignments Building-System-Plant connection –HVAC Systems.
Using Thermal Energy—Chapter 6
Using Thermal Energy Mrs. Nell 8 th Grade Physical Science Chapter 6 Review.
Using Heat Part 2. Science Journal Entry 32 Explain the advantages and disadvantages of thermal expansion.
© 2012 MITSUBISHI HEAVY INDUSTRIES – MAHAJAK AIR CONDITIONERS CO., LTD. All Rights Reserved. Bad case of Installation RAC-B-A07.
Energy and Heat. What is Energy? When something is able to change its environment or itself, it has energy Energy is the ability to change Energy has.
Components of Construction part 2
Chapter 6 Section 3.
Chapter 14 Heating, Ventilation & Air conditioning (hvac)
Chapter 5 – Thermal Energy
Unit 13 Oil-Burning Equipment
Section 6: Air-Conditioning (Heating And Humidification)
BUILDING HEATING AND COOLING
Heating, Ventilating, and Air Conditioning
Heating Ventilating and Air Conditioning
13.3 Using Heat.
DOMESTIC HEATING DESIGN PRINCIPLES
Electrical Gas Plumbing Heating & Cooling
Notes 7: Using Heat Chapter 6 Section 3 Page 172.
Heating, Ventilating, and Air-Conditioning
Ch. 16 Sec. 3 Using Heat.
______________ Combustion Engine
300 North Coit Road Suite 1525 Richardson, TX Phone: (972) Fax: (972)
Lecture Objectives: Discuss HW4 parts
FBE03: Building Construction & Science
Technology in Architecture
Presentation transcript:

MEP design Mechanical, Electrical, Plumbing

Often separate consultants Can be separate even within a single firm Often performed on a design-build basis (no drawings)

Mechanical Basic system function: Temperature conditioner (heat or cool) Heat exchanger (fan+coil, radiator) Package units Split systems (condenser/furnace + fan coil unit) Piped water (radiator/fan coil + chiller/boiler)

Mechanical Cooling systems: Forced air only Ventilation “Air Conditioning” (Refrigeration) – how does it work? Where does the heat go?

Mechanical Heating systems: Hot water gas boiler w/flue electric boiler radiator

Mechanical Heating systems: Hot water Radiant Flooring (heating & cooling)

Mechanical Heating systems: Forced air gas furnace w/flue Fan + coil

Mechanical Heating systems: Forced air Heat pump Why heat pumps don’t work in cold climates

Mechanical Ducting: Supply & Return Register types & locations Size & noise Rectangular vs Spiral Fresh air intake Exhaust (equipment rooms, restrooms)

Mechanical Equipment location (100’ refrigerant line, insulated) Vibration & Noise

Mechanical Sustainability Design for climate Building orientation Overhangs / exterior shading Thermal Mass Ventilation Evaporative cooling

Mechanical Title 24 Insulation (wall, floor, roof) R-value Insulated glazing

Mechanical Typical mechanical plan

Electrical Power: transformers, conduit (flex & EMT) Phone: punch block, PBX Data: switches, routers, servers Heat exhaust

Electrical Typical power plan

Electrical Lighting Reflected ceiling plans Title 24 Fluorescent vs. Incandescent Line voltage vs. low voltage (remote ballasts)

Electrical Typical RCP

Plumbing Hot & cold water (gas boiler + flue or electric) Tankless systems Vents – code at roof Drains Utility connection (sewer, storm drains, inverts)