Design of Concrete Structure I

Slides:



Advertisements
Similar presentations
Check Beam Shear.
Advertisements

1.
Example (10.2): Redesign the stair shown in Example (10.1) if it is a cantilever type of a clear span of 1.6 m. Solution : Minimum stair thickness required.
Graduation Project Thesis: Structural Analysis & Design of “Al-Mansour Mall”
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
Reinforced Concrete Design-8
Lecture 9 - Flexure June 20, 2003 CVEN 444.
Design of Concrete Structure I Eng. Tamer Eshtawi First Semester 2008 Eng. Tamer Eshtawi First Semester 2008.
Umm Al-Qura University Department of Civil & Structural Engineering
Lecture 33 - Design of Two-Way Floor Slab System
T6. DESIGN OF REINFORCED CONCRETE BEAM Reinforced concrete framed building T6. Design of reinforced concrete beam page 1. Alaprajz Floor plan Beam: linear.
ANALYSIS OF TWO-WAY SLABS WITH BEAMS
Overview Waffle Slab.
Reinforced Concrete Flexural Members
Design of Concrete Structure I
STAIRCASES. STAIRCASES Introduction Staircases provide means of movement from one floor to another in a structure. Staircases consist of a number of.
Shear and Diagonal Tension
Lecture 15- Bar Development
1 Design and drawing of RC Structures CV61 Dr. G.S.Suresh Civil Engineering Department The National Institute of Engineering Mysore Mob:
SHEAR IN BEAMS. SHEAR IN BEAMS Example (4.1): A rectangular beam has the dimensions shown in Figure 4.12.a and is loaded with a 40 ton concentrated.
Chapter-7 Bond Development Length & Splices
Lecture Goals Slab design reinforcement.
Abstract This project is a structural analysis and design of a residential building located in JENIEN City, The building is consisted of 7 floors. The.
ONE-WAY SLAB. ONE-WAY SLAB Introduction A slab is structural element whose thickness is small compared to its own length and width. Slabs are usually.
Chp.12 Cont. – Examples to design Footings
CTC 422 Design of Steel Structures
An-Najah National University Faculty of Engineering Civil Engineering Department Terra Santa School Structural Design and Analysis Prepared By: Bara Shawahna.
Copyright © 2011 Pearson Education South Asia Pte Ltd
Lecture Goals Doubly Reinforced beams T Beams and L Beams.
Reinforced Concrete Design II
786 Design of Two way floor system for Flat slab
Slab Design.
Reinforced Concrete Design II
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
Beam Design.
SHEAR IN BEAMS. SHEAR IN BEAMS Introduction Loads applied to beams produce bending moments, shearing forces, as shown, and in some cases torques. Beams.
University of Palestine
Plain & Reinforced Concrete-1 CE-313
Umm Al-Qura University Department of Civil & Structural Engineering
Reinforced Concrete Design
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Tulkarem Multipurpose Sport Hall Prepared by: Moatasem Ghanim Abdul-Rahman Alsaabneh Malek Salatneh Supervisor: Dr. Shaker Albitar.
Structural Design of Movenpick Hotel
◦ Ar-Rafedain building is 8 stories reinforced concrete building,located in Nablus city and used as commercial and residential building. ◦ The basement.
CTC 422 Design of Steel Structures
©Teaching Resource in Design of Steel Structures IIT Madras, SERC Madras, Anna Univ., INSDAG 1 COMPOSITE FLOORS - II.
An-Najah National University Faculty of Engineering Civil Engineering Department.
1 Design of Concrete Structure I Dr. Ali Tayeh First Semester 2009 Dr. Ali Tayeh First Semester 2009.
Design of One Way Slabs CE A433 – RC Design T. Bart Quimby, P.E., Ph.D. Spring 2007.
By Dr. Attaullah Shah Swedish College of Engineering and Technology Wah Cantt. Reinforced Concrete Design-6 Shear Design of Beams.
Prof. Shrikant M. Harle Asst prof. Dept of Civil Engg PRMCEAM
Dr Badorul Hisham Abu Bakar
AHSANULLAH UNIVERSITY OF SCIENCE & TECHNOLOGY DEPT
CIVL471 DESIGN OF RC STRUCTURES
Advisor: Dr. Bilal El Ariss
An-Najah National University Faculty of Engineering
786 Design of Two Way floor system for Flat Plate Slab
Outline: Introduction: a ) General description of project b) Materials
An-Najah National University
Lecture 39 - Design of Two-Way Floor Slab System
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
Design of Reinforced Concrete
Design Ribbed and Flat Slabs
Reinforced Concrete Design-6
Structure II Course Code: ARCH 209 Dr. Aeid A. Abdulrazeg
By :Dr. Aeid A. Abdulrazeg
2.2 STRUCTURAL ELEMENT Reinforced Concrete Slabs
" multifunctional building design"
An-Najah National University
Chapter 13 Concrete Form Design.
Presentation transcript:

Design of Concrete Structure I Dr. Ali Tayeh First Semester 2009

Lecture 12 One Way Slab Part 1

Slab – Minimum thickness

One-Way Slab Design Thickness of One-Way Slabs Fire Rating This is equal to the number of hours for unexposed surface to rise a set amount usually 120 o C 9.0 cm. 1 hour 12.5 cm. 2 hours 16.0 cm. 3 hours

Cover for Slab Reinforcement ACI Sec. 7.7.1 (min. cover for corrosion protection) ( 1.) Concrete exposed to earth or weather. < f16 = 4.0 cm > f16 = 5.0 cm ( 2.) Concrete not exposed to earth or weather. < f32 = 2.0 cm Min. covers for fire ratings should also be considered.

Minimum Reinforcement According to ACI-Code 7.12.2.1 and for steels yielding at , the shrinkage reinforcement is taken not less than 0.0018 of the gross concrete area, or

Solid slab Two way slab One-way slab Ribbed Slab Two way slab One-way slab

One-Way Solid Slab Design Reinforcement Typical Reinforcement in a one-way slab:

One-Way Solid Slab Design Cutoffs If requirements for use of ACI Moment Coefficients:

One-Way Solid Slab Design Need to confirm thickness is adequate for one-way shear. Difficult to place shear reinforcement in a slab. Minimum area of shear reinforcement required in slabs if Usual use

Moment Diagram: Approximate Method of Continuous Beams and One-Way Slabs: More than two slabs

Two slabs

Shear Diagram: Approximate Method of Continuous Beams and One-Way Slabs: More than two slabs

Two slabs

Summary of One-way Solid Slab Design Procedure Select representative 1-m wide design strip/strips to span in the short direction Choose a slab thickness

Calculate the factored load by magnifying service dead and live loads according to this equation . The dead load includes own weight of the slab in addition to the covering materials it supports. The live load is dependent on the intended use of the slab. Draw the shear force and bending moment diagrams for the strip

Example 1 Using the ACI-Code approximate structural analysis, design for a warehouse, a continuous one-way slab supported on beams 5.0 m apart as shown in Figure ‎. Assume that the beam webs are 30 cm wide. The dead load is 3 kN/m2 in addition to the slab own weight, and the live load is 2 kN/m2. Use , .

O.k.

O.k.

Ribbed Slab

One-way Ribbed Slab Design Notes According to ACI-Code 8.11.6.1, topping slab thickness is not to be less than 1/12 the clear distance between ribs, nor less than 5.0 cm. According to ACI-Code 8.11.8, shear strength provided by rib concrete Vc may be taken 10 % greater than those for beams. It is permitted to increase shear strength using shear reinforcement or by widening the ends of ribs Ribs are designed as rectangular beams in the regions of positive moment between the supports and as T-shaped beams in the regions of negative moments at the supports. Effective flange width beff is taken as half the distance between ribs, center-to-center

Summary of One-way Ribbed Slab Design Procedure The direction of ribs is chosen. The overall slab thickness h is determined based on deflection control requirement. The factored load on each of the ribs is computed. The shear force and bending moment diagrams are drawn. The strength of web in shear is checked. Design positive and negative moment reinforcement.

Example 2 Design a one-way ribbed slab to cover a 4 m x 10 m panel, shown in Figure below. The covering materials weigh 2 kN/m2, the live load is 2 kN/m2

An Example for Ribbed slab Reinforcement