PACKAGE UNITS GPG 10 AND 12 SEER.

Slides:



Advertisements
Similar presentations
Residential Gas – Honeywell Valve - Thermopile Powered Series 300/301
Advertisements

…just got better.
“Enerpak” Units » Propeller Type Fan » Size 100 – 400 MBH » 80% Thermal Efficiency » Natural or LP Gas » 10 Year Warranty on Heat Exchanger, Burners,
Daikin Altherma™ Troubling Shooting
Goodman and Amana Furnace Orientation.
Thermostats, Pressure Switches, and Other Electric Control Devices
HEAT PUMPS.
BUrners TRAining CEntre GAS BURNERS N 900 H/L N 900 H/L series.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
HVAC Commercial Ref.
38GXC(Q)/40GXC(Q) Service Training Sizes 18 and 24K.
Heating Control Devices
1 Direct Fired Gas Heating Presented by Jim Jagers of Applied Air.
Air-Conditioning Control Systems
Engineered Products Make-Up Air for Heating and Cooling.
HVAC121 – Gas Heat Flame Rectification.
Furnace Troubleshooting
7.3.2 Student Book © 2005 Propane Education & Research CouncilPage Identifying the Components and Operating Characteristics of Electronic Ignition.
Gas Furnace Controls Part 4.
S8910U1000 Universal Electronic Ignition Modules Training Module
Engineer Presentation
Product Introduction.
ST9120U1003 Universal Electronic Fan Timer Training Module
S9200U1000 Universal Integrated Furnace Control (UIFC) Training Module
Table of Contents Safety Circuits Induced Draft Motors Gas Valves
Variable Speed Indoor Blower Motor Robert Helt Technical Conference - Panama City Beach, Fl
Electrical Electricity Fuses Relays Solenoids Electrical Testing
Service/Review... Rule # 1: Use the KISS Principle!
Gas Furnace Planned Maintenance
Air-Source Heat Pumps I North Seattle Community College HVAC Program Instructor – Mark T. Weber, M.Ed. Airsource Heat Pump 1.
RESIDENTIAL AIR HANDLERS
Perfect solution for large building
Burners TRAining CEntre. RESIDENTIAL GAS BURNERS R D B R D B series GOALS: KEEP STRONG OUR POSITION ON RESIDENTIAL GAS BURNERS DEDICATED TO OEM’s MARKET.
Air Handler Terminology
Air Handler Terminology
BAKE BROIL - SELECT PROGRAM - CONV BAKE CONV BROIL SELF CLEAN On any diagram screen, double click any of the following components to bring you to a description.
Codan 5700 Series C-Band Transceiver Technical Overview.
Why Maintenance Tasks are Important Produced by Joe Marchese.
Unit 8 Gas-Burning Equipment. OBJECTIVES State the difference between a natural gas and an LP gas system. Describe several control sequences for gas heat.
LCD Wiring Diagram Presentation B / B.
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
We apply 120 VAC to the HM Unit (Remember to check polarity!) Our primary step down T/X provides power to terminal “X” and “COM” on the ignition control.
AIR CONDITIONING (COOLING)
BASIC ELECTRICITY AND MAGNETISM
E3 HVACR Controls and Devices
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
Two Stage Communicating System
Unit 13 Oil-Burning Equipment
Unit 7 Gas Heat: Natural and LP
10 12 and 14 TR Advanced Glycol Chiller
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
E3 HVACR Controls and Devices
E2 Motors and Motor Starting
Asahi/America Electric Actuators Series 94.
CONTROL BOX RMG
Asahi/America Electric Actuators Series 94.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Goodman and Amana Furnace Orientation.
S8910U1000 Universal Electronic Ignition Modules Training Module
Solstice All Options Gas Fired Fryer Service Presentation (CE-UK)
ST9120U1003 Universal Electronic Fan Timer Training Module
Universal Interrupted Electronic Oil Primary R7184U Training Module
Presentation transcript:

PACKAGE UNITS GPG 10 AND 12 SEER

TECHNICAL SUPPORT 888-593-9988 MARK STOKES 713-861-2500 EXT. 630

Model Number Chart

09 is for the month it was built 04 is for the year it was built SERIAL NUMBER 09 is for the month it was built 0409456678 04 is for the year it was built

12 & 10 SEER Packaged Gas Electric Fits in a standard size Pickup! 47” Wide

12 & 10 SEER Packaged Gas Electric Cooling Features: Convenient access panels to the compressor High-efficiency Scroll and Energy-efficient reciprocating compressor. Copper tube/aluminum fin coil. Liquid line filter drier. Fully charged R-22 system. Louvered Guard Protection

10 & 12 SEER Packaged Gas Electric Control Features: Convenient access panels to the Evaporator coil and control section. Direct spark ignition system, which includes a microprocessor based control for the entire ignition sequence, all blower operation and all safety circuits. Diagnostic Indicator provided for trouble shooting system faults.

Design Objectives 2 – 5 ton Single Phase 3, 4 & 5 ton Three Phase 12 &10 SEER Cooling, 80% AFUE Heating Capable of expansion to higher SEER ratings Convertible Easy Access Service Panels Architectural Gray

12 & 10 SEER Packaged Gas Electric Heating Features: Convenient access panels to the heating section. Redundant gas valve, natural gas and easy conversion to propane. Power-assisted combustion. L.P. Conversion Kit Available 12 & 10 SEER units offer a durable, T-140 Aluminized Steel tubular heat exchanger. California Low Nox Approved

We begin with T-140 Aluminized Steel tubes Wrinkle-bend Process We begin with T-140 Aluminized Steel tubes Manufacturing stress including wall-thinning is minimized Wrinkles are placed precisely where we want them Wrinkles promote turbulence to aid heat transfer and efficiency

Dual-diameter/Muffler-joint We apply a patented process to join tubes 1-3/4” diameter fits inside a 1-1/4” diameter Tubes are joined with a proprietary process Velocity of combustion products is optimized Efficiency is maximized

Tubular Technology Renders Clamshell Obsolete 800°F 1,000°F 1,000°F 300°F 300°F 300°F 300°F 110°F Non-uniform thermal growth Eyelets can pop Stress-cracks can form Tube can grow in length and diameter Growth is uniform at the cross-section No opportunity for stress-cracks

INSTALLATION

CLEARENCE FROM COMBUSTIBLE MATERIALS

CURB INSTALLATION

RIGGING

PIPING

CONDENSATE DRAIN

FLUE HOOD & BUG SCREEN

12 & 10 SEER Packaged Gas Electric McDaniel Metals Accessories By

10 & 12 SEER Packaged Gas Electric Blower Features: Convenient access panels to the blower section. Filter rack included on 12 SEER large (4 &5 ton) chassis. Easy removal of blower with two screws. Multi-speed evaporator blower. Fully insulated with blankets of fiberglass.

12 & 10 SEER Packaged Gas Electric Base Features: 042 Aluminized Steel Bottom/Base Pan 2” High Base Rails Shipped with four panels

DUST COVER INSTALLATION

RECOMMENDED FILTER SIZES

Electrical 208/230 Volt Power connections and 460 Volt available in 5 Ton Cool only model Single Phase and Three phase models available Maximum Over current Protection determined by model

Wiring All wiring should be made in accordance with the National Electrical Code. Wire sizes and over current protection should be determined from the unit nameplate ampacity. Wire sizes should not be smaller than recommended by these two sources. All exterior wiring must be within approved weatherproof conduit. The unit must be permanently grounded in accordance with local codes.

HIGH VOLTAGE WIRING

LOW VOLTAGE WIRING

CHECKING THE COMPRESSOR

CHECKING CONTACTOR

CHECKING CAPACITOR

COMPRESSOR NORMINCLATURE

COMPRESSOR DIAGONSTICS

TESTING FOR GROUNDED COMPRESSOR

FLOW RATER

EVACUATION

HEATING SIDE OF GPG

CHECKING GAS PRESSURE Manifold Outlet Gas Pressure Natural…. Min. 3.2” W.C., Max 3.8” W.C. Propane….Min. 9.7” W.C., Max. 10.3” W.C.

CHECKING BURNERS

Burner

BURNER BOX REMOVAL

CHECKING BURNERS

CHECKING LIMIT SWITCH

Pressure Switch Check Meter on AC Voltage Setting ; between Quick Connect on Pressure Switch and Ground Prior to Operation check for open side of Pressure Switch (No Voltage Present) When Pressure Switch Closes 24 Volts should be present on N/O side Issue: Watch for switch bounce on windy days Issue: Watch for P.S. drop-out for low pressure

CHECKING PRESSURE SWITCH

CHECKING PRESSURE SWITCH

PRESSURE SWITCH

INDUCED DRAFT BLOWER

Understanding ECM Motors

Understanding ECM Motors What does ECM mean? How does the ECM work? Variable Speed vs Constant Volume. What is PWM How does the ECM sense static pressure? Troubleshooting ECM motors. In this discussion we will be covering the following topics; What does ECM mean? Who came up with that acronym? How does the ECM work? Variable Speed vs. Constant Volume. What is PWM How does the ECM sense static pressure? Troubleshooting ECM motors.

BLOWER MOTOR & HOUSING

Electronic Controls

B18099-18 Control B18099-21 Has Green Diagnostic LED B18099-21 Cannot be used alone; must be used with B18099-22 Control B18099-21 Control is set up for 50Hz Operation and for use in Europe (CE Mark)

Control Environment +80 to -40 Degrees Celsius (+176 to -40 F) 10% to 95% R.H. Non-Condensing 98 to 132VAC Line Voltage 18 to 30VAC Control Voltage Frequency - 60Hz UL & cUL Approved

General Functions “W” Input Off (Call for Heat Satisfied) “W” Input On (Call for Heat) Checks to see pressure switch open Turns on Inducer Pressure Switch Closes; 15 Second Pre-Purge Starts Sparking & Gas Valve Turns On for 7 Seconds Flame Sensed Anytime During Spark Gas Valve Stays On Blower Comes On after 30 Second Delay “W” Input Off (Call for Heat Satisfied) Gas Valve De-Energizes Immediately Inducer Remains on for 29 Second Post Purge Indoor Blower De-Energizes after Selected Blower Off Delay

General Functions Continued.... Single Compressor Mode (Tab is not Broken) “Y” Input On (Call for Cooling) 3 Minute Anti-Short Cycle Timer from the time the compressor was last on. Cooling Speed Blower after a 7 second delay “Y” Input Off (Call for Cool Satisfied) Cooling Speed Fan Off after 60 Second Delay Dual Compressor Mode (Tab is Broken) 1st Stage Compressor is Energized Externally “Y” Input On for 2nd Stage Cooling after 7 Second Delay “Y” Input Off ; Cooling Speed Fan off after 60 Second Delay

General Functions Continued.... “G” Input On (Call For Fan) Fan Immediately on Heat Speed “G” Input Off Fan Immediately Shuts Off If “Y” input Occurs During “G” Blower Switches to Cooling Speed If “W” Occurs During “G” Blower off when Heat Blower On Delay Begins Continuous Fan Operates while control is in Heat Mode Lockout Test/Speed-Up Bypasses Compressor Short-Cycle Timer If Shorted for Over 4 Minutes ; Control Ignores = Operates Normal

Diagnostic Codes Steady On = Normal Operation in Standby 1 Flash = Lockout for Ignition Failure or Flame Dropouts 3 Trials for Ignition or 5 Flame Losses 2 Flashes = Pressure Switch Open with Inducer On 3 Flashes = Pressure Switch Stuck Closed with Inducer Off 4 Flashes = Limit Switch Open Heat Speed Blower and Inducer On Until Limit Closes Blower Runs thru Off Delay; Inducer runs thru 29 Second Post-Purge 5 Flashes = Flame Detected with Gas Valve Off Blower and Inducer Both On Until No Longer Sensed Control Locks out But Senses Limit and Flame Control is Reset By Removing Power or after 1 Hour Automatically 6 Flashes = Compressor Delayed for Short Cycle/Staging Timer Status Light Off = Board Hardware Fault

Flame Sense Checking Digital Meter set for lowest uA Setting Meter in series with Flame Sense Rod Wire Control must read a minimum of .5uA during flame sensing period Average current reading is around 3-5uA. Control constantly monitors Flame during heating operation Issue: Flame Sense Rod gets corroded ; Clean w/ steel wool Issue: Flame Rod not situated in Flame Correctly

Ground Check Meter set to Ohms or Resistance Setting Place Meter from P1-6 or COM quick connect to chassis ground Reading should be near Zero ohms Issue: COM Quick Connect Loose ; causes board resetting when blower starts Issue: Flame Sensing problems if improper grounding in system

GPG TROUBLESHOOTING THEORY OF OPERATION Control of heating, cooling, and fan functions in response to a standard thermostat Direct spark ignition using a microprocessor to control timing, flame sensing, and ignition retries Monitoring of system pressure switch and limit switch Control of gas valve, indoor fan, and induced draft motor based on the thermostat demand and status of safety inputs Control of compressor contactor Diagnostic indicator to provide information on power to the control and control status

GPG TROUBLESHOOTING Summary of Timing Functions (in seconds) Function Signal Name Delay-On Delay-Off Heat Speed MV (1) 30 120, 135,150 (2) Cool Speed Y 7 60 Compressor 60 (3) 180 (4) Induced Draft 15 (5) 29 1. Heat speed delay on and off occur only after flame has been sensed and main valve (MV) is energized Selectable with jumpers 3. Indicates timing when “Two Stage Comp” tab is broken off, timer becomes delay on make 4. Indicates timing when “Two Stage comp”tab is not broken off, timer becomes compressor lock out between cycles(I.e. Minimum timing between compressor cycles) 5. Prepurge timing (not delay on )

GPG TROUBLESHOOTING Inputs Limit Switch –The limit switch is connected to control pins 4 and 5. The limit switch is connected is electrically between fused 24 VAC and the thermostat R Pressure Switch-The pressure switch is connected on pins 6 and 8. The pressure switch “W and the gas valve relay contacts Thermostat call for Heat “W”-24 VAC thermostat input. Connection via pin 10 Thermostat call for cool “Y”- 24 VAC thermostat input connections via pin 11 Thermostat call for fan “G”- 24 VAC thermostat inputs. Connection via pin 7 Flame Sense- Open circuit flame sense voltage shall be approximately 100 VAC . The control requires at least .5 microamperes DC flame current to guarantee flame is sensed

12 & 10 SEER Packaged Gas Electric Leading Warranties: 12 SEER offers an Aluminized Steel Heat Exchanger with a 20Year limited Warranty and10 Year Limited Warranty on the Compressor and Parts. 10 SEER offers an Aluminized Steel Heat Exchanger with a 20Year limited Warranty and 5 Year Limited Warranty on the Compressor and Parts.