"To be or not to be - shielded or unshielded? That is the question!" Presentation title (IMPORT THROUGH MENU View or Insert -> Header & Footer)

Slides:



Advertisements
Similar presentations
Network Hardware and Physical Media
Advertisements

Radio over fiber.
IST 126 Transmission Media. Characteristics of Transmission Media Cost Ease of installation Bandwidth capacity – the amount of data that can be sent in.
Physical Media PHYSICAL MEDIA.
Michiel Pelt, Nexans Cabling Solutions, Alsembergsestw 2b3, B-1501 Buizingen, Belgium Background, content and future of EN Background, content.
Connecting to a computer Network Network interface Card (NIC) Connecting Devices Network Cables Wireless Networks Network Topology Network Operating System.
Designing a EMC Compatible Electronic Meter using AD7755 a.
Introduction to Network (c) Nouf Aljaffan
Powerline Communications: Channel Characterization and Modem Design Yangpo Gao Helsinki University of Technology
William Stallings Data and Computer Communications 7 th Edition Chapter 4 Transmission Media.
1 Part II: Data Transmission The basics of media, signals, bits, carriers, and modems Fall 2005 Qutaibah Malluhi Computer Science and Engineering Qatar.
Classes of transmission media
Industrial Solutions and Services Your Success is Our Goal EMC Testing for Emission and Immunity Diethard E. C. Moehr, I&S CTF EMC.
NETWORK DESIGN Customer requirements Network topologies Cable choice Hardware TSB 75 TSB72.
Computer Networks & Security
Physical Layer B. Konkoth.
CCNA 1 Module 4: Cable Testing.
Transmission lines.
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID Physical Layer Protocols.
Chapter 2.  Types of Network  Circuit Switched & Packet Switched  Signaling Techniques  Baseband & Broadband  Interference  Transmission Medium.
Communication channels and transmission media
Network PHY - Cabling Cabling Issues with cabling LANs Types of equipment/choices Version2, 12/09/2015Slide 1.
1 Business Telecommunications Data and Computer Communications Chapter 4 Transmission Media.
ECOM 4314 Data Communications Fall September, 2010.
7.1 Chapter 7 Transmission Media. 7.2 Figure 7.1 Transmission medium and physical layer Transmission media are located below the physical layer and are.
Signal Propagation Propagation: How the Signal are spreading from the receiver to sender. Transmitted to the Receiver in the spherical shape. sender When.
Physical Transmission
Physical Transmission
Introduction to Network (c) Nouf Aljaffan
Transmission Media The physical pathways that connect computers and devices on a network.
CSCI 465 Lecture 5 Martin van Bommel CSCI 465 Data Communications and Networks 1.
Lecture 8 Cable Certification & Testing:. Cable Distribution Cable Distribution Equipment UTP (Unshielded Twisted Pair) UTP Cable Termination Tools UTP.
Copper Media Describe the specifications and performances of different types of cable. Describe coaxial cable and its advantages and disadvantages over.
Bits (0s and 1s) need to be transmitted from one host to another. Each bit is placed on the cable as an electrical signal or pulse. On copper cable the.
IST 126 Computer Networks Spring, What is a Computer Network? A group of computers and other devices that are connected together in order to share.
Submitted By: A.Anjaneyulu INTRODUCTION Near Field Communication (NFC) is based on a short-range wireless connectivity, designed for.
1/21 Chapter 4 – Transmission Media. 2/21 Overview  guided – copper twisted pair, coaxial cable optical fiber  unguided – wireless; through air, vacuum,
MASNET GroupXiuzhen ChengFeb 8, 2006 Terms and Concepts Behind Wireless Communications.
The Aspect of RF & EMC in Today’s World National University of Singapore B.Tech (Electronics) EE1001E:Emerging Technology in Electrical Engineering 19.
© Cisco Systems, Inc. All rights reserved. Cisco Public ITE PC v4.1 Chapter5 1 Computer Networks.
 Cables  Network Interface Card (NIC)  Repeaters  Hubs  Switches  Routers  Gateways  Bridges.
Prof R T KennedyEMC & COMPLIANCE ENGINEERING 1 EET 422 EMC & COMPLIANCE ENGINEERING.
Programmable Logic Controllers
Transmission Media. Characteristics to consider for Media Selection Throughput Cost Installation Maintenance Obsolescence vs bleeding edge Support Life.
CABLING SYSTEM PROTECTION. Screening/Shielding  1 In the Signamax Cabling System for the efficient screening of the telecommunications systems, the screen.
Lesson 2—Networking BASICS1 Networking BASICS Network Media Unit 1 Lesson 2.
William Stallings Data and Computer Communications 7th Edition
+ Lecture1 Transmission Media Asma Alosaimi 1. + Topics: Review Transmission media types Copper Media Fiber Optical Media Wireless Media 2.
Transmission Media The transmission medium is the physical path by which a message travels from sender to receiver. Computers and telecommunication devices.
IST 126 Computer Networks Spring, What is a Computer Network? A group of computers and other devices that are connected together in order to share.
IEEE NPEC SC2 Equipment Qualification Electromagnetic Compatibility Compliance Type Test-Design Considerations- Installation and Mitigation Standard/Guidance.
William Stallings Data and Computer Communications
Entrance to EMI.
Physical Transmission
Level 2 Diploma Unit 10 Setting up an IT Network
Physical Transmission
Chapter 7 Transmission Media.
7. Transmission Media.
Transmission Media.
Networks in our daily life
Physical Transmission
LECTURE #01 TRANSMISSION MEDIA
Powerline Communications: Channel Characterization and Modem Design
Physical Transmission
Computer Networks Topics: Twisted Pair and Fiber Optic Cable
William Stallings Data and Computer Communications
University of Houston Datacom II Lecture 1C Review 2
Transmission Media Located below the physical layer and are directly controlled by the physical layer Belong to layer zero Metallic Media i.e. Twisted.
NETWORK COMPONENTS PHYSICAL MEDIA
William Stallings Data and Computer Communications
Presentation transcript:

"To be or not to be - shielded or unshielded? That is the question!" Presentation title (IMPORT THROUGH MENU View or Insert -> Header & Footer)

" To be or not to be - shielded or unshielded? That is the question!" Matthias Gerber, Reichle & De-Massari AG September, 2010

"To be or not to be - shielded or unshielded? That is the question!" - New application  new demands - Susceptibility to disturbances ↗ - Marketing smog screen. STP vs. UTP Motivation

"To be or not to be - shielded or unshielded? That is the question!" t U=2 V Bit = 12 Pulses NRZ Coding Modulation: e.g. PAM Bit = 3 Pulses Bits U = 0.13 V 4*t PAM 16 Modulation Reduces signal bandwidth, increases susceptibility to noise

"To be or not to be - shielded or unshielded? That is the question!" 10 MHz Manchester Coding 20 MSymbols/s 417 MHz PAM MSymbols/s 10GBase-T 62 MHz PAM MSymbols/s 1000Base-T 31 MHz MLT MSymbols/s 100Base-TX Signal Level 0V 1V -1V 0.5V 0.13V 1.0V 1.7V Spectral Bandwidth 10Base-T Development signal strength senders

"To be or not to be - shielded or unshielded? That is the question!" Signal Level 0V 1V -1V 10Base-T 100BASE-TX 1000BASE-T 10GBASE-T Manchester Coding MLT-3 PAM 5 PAM V 0.81V 10 MHz IL= 6.5 dB 20 MSymbols/s 25 MSymbols/s 125 MSymbols/s 800 MSymbols/s Spectral Bandwidth 31 MHz IL= 11.4 dB 62 MHz IL= 16.3 dB 417 MHz IL= 44.7 dB 0.08V V 50x Development signal strength receivers

"To be or not to be - shielded or unshielded? That is the question!" C par M ind -U C I dist /2 UCUC U D =0 I dist1 I dist2 U C2 U C1 U D >0 U D = U C2 – U C1 Unbalance atten. = 20*Log(U D /U dist ) Perfectly balancedImperfectly balanced I dist I dist1 I dist2 U dist Disturbance I dist I dist /2 U dist Noise: common mode disturbances

"To be or not to be - shielded or unshielded? That is the question!" V 20m Conduit / Raceway Cable Test setup: 10GBase-T 1000Base- T Coupling: raceway to UTP cabling

"To be or not to be - shielded or unshielded? That is the question!" Frequency a coupl Unbalance Unscreened 0 dB P Com P Dif P‘ Com P Com P Dif P‘ Com Coupling attenuation a coupl =10*Log(P Com /P Dif ) Unbalance attenuation Screening attenuation Unbalance Screened Screening attenuation New Parameter: Coupling attenuation(CA)

"To be or not to be - shielded or unshielded? That is the question!" Schematic drawing of the test set-up for coupling attenuation 68 dB The coupling attenuation of the link is determined by means of the absorber clamp method according to EN :2004: ISO/IEC Amendment 1 ( ), Class E A limits lg(f) ISO/IEC Industrial Premises MICE Categorization: E 1 (Office)  a coupl = 40 dB E 2 (Light industry)  a coupl = 50 dB E 3 (Factory floor)  a coupl = 60 dB ISO/IEC Amd.1 ( )

"To be or not to be - shielded or unshielded? That is the question!"  Primarily between same colored pairs (same lay length)  Difficulties to test in the field  X-Talk of neighboring channels  Increases in parallel runs New parameter: Alien Crosstalk (AXT)

"To be or not to be - shielded or unshielded? That is the question!" Active DSP Echo- and NEXT – compensation NEXT:>40 dB FEXT:>25 dB RL:>55 dB 10GBase-T Transmission Alien Crosstalk No synchronization  no active compensation for Alien Crosstalk Active Compensation with 10GBase-T

"To be or not to be - shielded or unshielded? That is the question!" What EMC properties do shielded and unshielded cabling components possess? What special measures are necessary to take for screened or unscreened systems? Which advantages and disadvantages are linked to screened or unscreened systems? Give guidance to planners or end users to prevent confusion and uncertainty when select systems. Providing a fair and independent comparison of the EMC behavior of screened and unscreened cabling Independent LAB’s Study goals

"To be or not to be - shielded or unshielded? That is the question!" The study was commissioned by: The study was carried out by: GHMT AG In der Kolling Bexbach

"To be or not to be - shielded or unshielded? That is the question!" Cabling sample selection

"To be or not to be - shielded or unshielded? That is the question!" 4x Switch7x Server Manufacturer Extreme Networks IBM Typ Summit X450a-24t X3550 Slot Summit XGM2-2bt INTEL 10Gigabit AT Server Adapter Active components used

"To be or not to be - shielded or unshielded? That is the question!" Server Patch cord Equipmen t cord Installatio n cable Switch Server Equipmen t cord Patch panel System set-up schematic

"To be or not to be - shielded or unshielded? That is the question!" System set-up anechoic chamber

"To be or not to be - shielded or unshielded? That is the question!"

EN Tests the ability of a device not to disturb other equipment in their normal operation Emission: Radiated field strength

"To be or not to be - shielded or unshielded? That is the question!" 10GBase-T: System 02 (U/UTP) vs. System 05 (S/FTP) Emission: Radiated field strength

"To be or not to be - shielded or unshielded? That is the question!" Emission: Radiated field strength 1000Base-T: System 02 (U/UTP) vs. System 05 (S/FTP)

"To be or not to be - shielded or unshielded? That is the question!" Spectrum 1000Base-T Spectrum 10GBase-T 10GBase-T vs. 1000Base-T: System 02 (U/UTP) Emission: Radiated field strength

"To be or not to be - shielded or unshielded? That is the question!" No significant differences in terms of EM emission ! single-sided earthing double-sided earthing 10GBase-T: System 05 (S/FTP) different earthing Emission: Radiated field strength

"To be or not to be - shielded or unshielded? That is the question!" The better the EMC quality of the cabling, the lower the radiated radio-frequency disturbance field strength MHz 10GBase-T: Overview Emission: Radiated field strength

"To be or not to be - shielded or unshielded? That is the question!" Screened cabling will be able to transmit 10GBase-T and fulfil Class B emission limits (for residential areas) Unscreened cabling with 10GBase-T fulfils Class A emission requirements (for business areas, e.g. dedicated Office spaces, data centre) The better the CA (and therefore the screening efficiency) the smaller the radiated field strength. No recognizable improvement of the emission from double sided earthing to single sided earthing. 10GBase-T: Summary Emission: Radiated field strength

"To be or not to be - shielded or unshielded? That is the question!" EN : Radiated, radio-frequency, electromagnetic field immunity test EN : Electrical fast transient/burst immunity test EN : Immunity to conducted disturbances, induced by radio-frequency fields EN : Power frequency magnetic field immunity test EN :Electrostatic discharge EMC immunity tests performed

"To be or not to be - shielded or unshielded? That is the question!" Stress level 1 Stress level 4 Stress level 3 Stress level 2 Test criterion: example plot

"To be or not to be - shielded or unshielded? That is the question!" Excerpt for criterion E (Electromagnetic compatibility) MICE-Classification EN :

"To be or not to be - shielded or unshielded? That is the question!" EN Tests the ability of a device to operate normally in the presence of electromagnetic fields Immunity: Radiated, radio- frequency, electromagnetic field

"To be or not to be - shielded or unshielded? That is the question!" E3E3 E1/E2E1/E2 Immunity: Radiated, radio-frequency, electromagnetic field, Overview

"To be or not to be - shielded or unshielded? That is the question!" All screened systems allow for 10Gpbs operation in E1 / E2 environments. For harsher environments, an S-FTP screen construction is necessary. Double-sided earthing does not lead to any improvement over single sided earthing. Unscreened systems meet the requirements of class E 1 / E 2 for 1 Gbps. For 10Gbps additional protection measures are necessary. Immunity: Radiated, radio-frequency, electromagnetic field, Summary

"To be or not to be - shielded or unshielded? That is the question!" Practical test: - Walkie-talkies - - mobile phone - - GSM card - Walkie-talkies, mobile phone, GSM card Practical test: 10GBase-T

"To be or not to be - shielded or unshielded? That is the question!"  Interference (abort data transmission) No interference observed Usage of a wireless communication device in proximity of an unscreened cabling (e.g. in a data center) can impair the data transmission. Walkie-talkies, mobile phone, GSM card Practical test: 10GBase-T

"To be or not to be - shielded or unshielded? That is the question!" EN Tests the ability of a device to operate normally in proximity of disturbing power lines and equipment Immunity: Fast transients (burst) test

"To be or not to be - shielded or unshielded? That is the question!" E3E3 E1E1 E2E2 10GBase-T, Overview Immunity: Fast transients (burst) test

"To be or not to be - shielded or unshielded? That is the question!" E3E3 E2E2 E1E1 10GBase-T, Earthing influence Immunity: Fast transients (burst) test

"To be or not to be - shielded or unshielded? That is the question!" All screened systems allow for 10Gpbs operation in all environments (E1 – E3). Quality of the screen improves immunity. Double-sided earthing does improve immunity against fast transients over single sided earthing. The screen connection has to be continuous from Switch to Server (no U-UTP patch cords). Unscreened systems meet the requirements of class E 1 for 1 Gbps. For 10Gbps operation carefully routing necessary to separate from power cables 10GBase-T, Summary Immunity: Fast transients (burst) test

"To be or not to be - shielded or unshielded? That is the question!" Practical test: - fluorescent lamp - Fluorescent lamp Practical test: 10GBase-T

"To be or not to be - shielded or unshielded? That is the question!"  Interference (abort data transmission) No interference observed Fluorescent lamps can impair the 10GBase-T in U-UTP systems, when distance between data cable and power cable or fluorescent lamp is not sufficient. Fluorescent lamp Practical test: 10GBase-T

"To be or not to be - shielded or unshielded? That is the question!" Experiment: -mesh cable tray- D = 0 – 50 cm 10GBase-T, Fast transients (burst) test Experiment: Mesh cable tray

"To be or not to be - shielded or unshielded? That is the question!" E3E3 E1E1 E2E2 distance between power and data transmission cables 10GBase-T, Fast transients (burst) test, Overview Experiment: Mesh cable tray

"To be or not to be - shielded or unshielded? That is the question!" Screened systems meet the environmental class E 3 at all distances, even without separation. For unscreened systems separation to power cabling is essential. For class E 1 distances must be ≥ 30 cm. The standardized capacitive coupling clamp simulates a cable installation with power and date cable very near together (< 1cm). 10GBase-T, Fast transients (burst) test, Summary Experiment: Mesh cable tray

"To be or not to be - shielded or unshielded? That is the question!" EN Tests the ability of a device to operate normally in proximity disturbing power lines Immunity test: Conducted disturbances, induced by radio- frequency fields

"To be or not to be - shielded or unshielded? That is the question!" Immunity test: Conducted disturbances, induced by radio- frequency fields, overview E3E3 E 1 /E 2

"To be or not to be - shielded or unshielded? That is the question!" The screened systems meet the requirements of MICE class E 3 for 1000Base-T and 10GBase-T. Higher quality screening provides higher immunity against induced radio frequency fields. Double-sided earthing does not improve the immunity significantly over single-sided earthing. Unscreened systems meet the requirements for E 1 / E 2 environments in the 1Gbps operation mode. For 10Gbps additional protection against conducted induced radio-frequency fields is needed. Immunity test: Conducted disturbances, induced by radio- frequency fields, Summary

"To be or not to be - shielded or unshielded? That is the question!" EN Immunity: Power-frequency magnetic field Tests the ability of a device to operate normally in the presence of large magnetic fields

"To be or not to be - shielded or unshielded? That is the question!" E3E3 E1E1 E2E2 10GBase-T, Overview Immunity: Power-frequency magnetic field

"To be or not to be - shielded or unshielded? That is the question!" All systems tested meet the requirements of MICE class E 3 in all three operation modes. The equalizing currents ascertained with screened systems do not have any impact on data transmission. Equalizing currents can be reduced by double-sided earthing. 10GBase-T, Overview Immunity: Power-frequency magnetic field

"To be or not to be - shielded or unshielded? That is the question!" EN Immunity: Electrostatic discharge

"To be or not to be - shielded or unshielded? That is the question!" * Conducted discharge was not tested for U/UTP systems E 1, E 2, E 3 * 10GBase-T, Overview Immunity: Electrostatic discharge

"To be or not to be - shielded or unshielded? That is the question!" The screened systems meet the requirements for all environments in all three operation modes both for air and for contact discharge. The unscreened systems react very sensitive to electrostatic discharges. Additional protection measures are necessary for a safe operation. The screen seams to offer a primary discharge path to earth, preventing the discharge to reach the vital intestines of a data cable. 10GBase-T, Summary Immunity: Electrostatic discharge

"To be or not to be - shielded or unshielded? That is the question!" Conclusions of UTP/STP study

"To be or not to be - shielded or unshielded? That is the question!" EMC results, Summary

"To be or not to be - shielded or unshielded? That is the question!" Secure 10GBase-T transmission, requires careful consideration of the environment to choose cabling components accordingly. Coupling attenuation as a parameter (especially when measured up to 1 GHz) represents the EMC behavior for emission and immunity with good correlation. The more elaborate the screen construction, the lower the emission and the better the immunity against disturbances from the outside. Conclusions of UTP/STP study (1)

"To be or not to be - shielded or unshielded? That is the question!" Screened cabling systems with S-FTP construction are well suited to carry 10GBase-T under all environmental classes Screened solutions with F-UTP construction are good for office environments. Unscreened cabling systems can only be used for 10GBase-T outside residential areas (e.g. dedicated offices, data centers). Conclusions of UTP/STP study (2)

"To be or not to be - shielded or unshielded? That is the question!" For unscreened cabling to transport 10GBase-T special measures must be taken to reduce the exposure of the cabling to external disturbances: –Careful separation of data cabling to power cabling and disturbing equipment –Usage of dedicated metallic raceways for data cabling –Prevent usage of wireless devices in the proximity of the cabling –Prevent the possibility of ESD Conclusions of UTP/STP study (3)

"To be or not to be - shielded or unshielded? That is the question!" Only the very best unscreened solution will be able to deliver 10GBase-T For the decision of screened or unscreened cabling for 10GBase-T, the whole of the environment and the installation specifics have to be taken into account. Conclusions of UTP/STP study (4)

Naslov predavanja

"To be or not to be - shielded or unshielded? That is the question!"Presentation title (IMPORT THROUGH MENU View or Insert -> Header & Footer) Thank you for your attention!