Tesar.

Slides:



Advertisements
Similar presentations
Seminar on Circuit Breaker
Advertisements

Series L Air conditioners for Laboratories.
Inspection & Preventive maintenance of breakers
Zone Control Air System Why? 1.Provides room by room comfort control. 2.Reduces equipment run time. 3.Eliminates hot/cold rooms. 4.Works with conventional.
1 CNS/GSS/2008/M1 1 Module 1 Basic Terminologies and Characteristics of Switchgear.
Refrigerators.
Setup/Installation/Operation of an Environmental Control Unit (ECU)
RMM Systems, LLC By Sam Rietta RMM Systems, LLC is a manufacturer's representative firm focused on providing value added sales solutions by providing.
Quad Plus Shredder Drive Maintenance Joe Kowalkowski Engineering Manager – Recycling Industry
Properties of cast resin transformers
GENERATOR PROTECTION.
MAIN ELECTRICAL SURVEY ITEMS, GENERATORS AND GOVERNORS,, CIRCUIT BREAKERS, SWITCHBOARDS AND FITTINGS (Adapted from:D.T. Hall:Practical Marine Electrical.
Sleek Stabilizer for A/C Units By Executive Engineer (Electrical) BSNL, Electrical Division,Tirunelveli.
Contactor, Relays and Overloads
Head (Project & Service)
HVACR416 - Design Humidification. Relative Humidity 1.Air in the home is artificially dried out when it is heated. 2.Because warm air expands, this expansion.
Dry type transformers Zaragoza Traction application
Dry type transformers Zaragoza Accessories and options
Transformer.
Ministry of Electricity & Energy Egyptian Electricity Holding Company
Dry type transformers Zaragoza Drives application
Dry type transformers Zaragoza Our product
Frankfurt (Germany), 6-9 June 2011 SINGH– US – Session 1 – 0952 Dry-type Transformer for Pole Mounted Application.
1111Challenges for reliable offshore transformersTRANSFORMING YOUR NEEDS INTO SOLUTIONS Challenges for Reliable Offshore Transformers Dr. Jan.
Single Phase IEC and EATS Distribution Transformers
Chapter 2 Transformers.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
Domestic Natural Gas Installations Marc Billington.
Pole Mounted Switch Disconnector NPS
Electrical Installation 2
Settings & Adjustments. Settings & Adjustments.
Vacuum system.
Dry type transformers Zaragoza Aluminum vs. Copper
C. Sumereder Austria Barcelona May Aren´t there any technological future for transformers? C. Sumereder Graz University of Technology Dep.
Protection & Switchgear
Transformer condition assessment with an integrated test van
POWER HOUSE.
A Presentation On Summer Training At Bharat Heavy Electricals Limited, Haridwar.
A Presentation On 132 KV GSS BEHROR
A Presentation On Construction Of Turbo Generator
CONTENS 1. Production Capacity 2. Production Range
A Presentation on construction of Turbo Generator.
Craig T. Riesen Energy Workshop II 1 Electricity & Generation Basics of Electricity and Electrical Transmission Transmission Generation electrons.
Practical experience with the AD Stochastic Cooling Murphy’s Law R. Louwerse.
Switches and Over Current Protective Devices Class Instructor ALPHER E. DE VERA, uap.
REDA Production Systems
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
Internal Guide : Batch No : 4 Mrs.Punyavathi Madam
Instrument Transformer Electrical Measuring Instruments & Instrumentation 3rd SEMESTER ELECTRICAL ENGG.
1 :. Introduction These are special type of transformers used for the measurement of voltage, current, power and energy. As the name suggests, these transformers.
Piston Engine Propulsion Ignition. Ignition in a piston engine requires: Spark plugs Magneto Condensers Distributor Contact breakers electronic systems.
HNC/D Engineering Science
POWER FACTOR CORRECTION
POWER DISTRIBUTION & POWER LOSS REDUCTION METHODS
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
12 good reasons to buy an ABB TrafoStar™ transformer
SIGENTICS HV Series S-modyn
Testing of Transformers
A presentation on Measurement of Winding Resistance and Insulation Resistance of 3 Phase 11 kV/ 433 V, 16KVA Oil cooled type Transformer PRESENTED BY:
المحولات Transformers
SHANGHAI ROTORCOMP COMPRESSOR ONLY USE.
Cashew Dryer User Manual
Its strengths, your benefits
Its strengths, your benefits
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Instruments & Electrical Measurements Lecture 4
Presentation transcript:

Tesar

The Company Tesar, whose sales amount in 2004 has been 22,7 million € is one of the most important reality operating in UE in the field of designing and manufacturing of CAST-RESIN Transformers. The continuous developments, research, studies and tests, as well as the up-to-date of its own staff has allowed Tesar to reach a high degree of reliability and to satisfy any particular request of our Customers, and to develop new tailor made projects/products.

The History Tesar, acronym of Electrical Transformers Special Application in Resin, has been founded in 1980 as Company of Eni Group, introducing, first in Italy, the Cast-Resin technique for power transformers. In 1986 Tesar has been acquired by a private group and the production has been expanded also to measurement transformers. Today Tesar is a leader at international level. All the Tesar production, carried out in the 2 production plants in Chiassa Superiore and in Chiaveretto, is the results of a continuous research and development and it is based on the use of advanced technologies and of selected materials.

Products: Power Transformers Distribution Transformers Production range: rated power from 100 up to 3150 kVA, rated voltage from 1 up to 36 kV. Special Transformers Rated power up to 18 MVA, rated voltage up to 36 kV, for rectifier, traction, induction oven application and for motors starting. Extreme installation as: offshore, windmill, crane and in extremely polluted ambients. Autotransformers

Products: Power Transformers Standard Transformers Special transformers supplied at CERN Special transformers supplied acc. to Kahramaa spec.

Certification 1994 - ISO EN 9002 certificate 1995 - ENEL homologation for classes E1-C1-F1 c/o CESI 1996 - ENEL homologation for classes E2-C2-F1 c/o CESI 2001 - Iso EN 9001:2000 Certificate 2005 – Successful tests for E2-C2-F1 to IEC 60076-11 c/o CESI

Conformity to classes E2 C2 F1 Tesar transformers are designed and manufactured according to the following classes, required by CENELEC and today by IEC 60076-11 standards, since more than 10 years: E2 C2 F1 E2 Ambiental Transformer suitable to be installed in ambient with substantial condensation and pollution C2 Climatic External installation. Transformer suitable to be kept and used with ambient temperature up to -25°C F1 Fire behavior Transformer with characteristics of self-extinction and of non-emission of toxic substances and gases

Reliability More than 28.000 transformers actually working The annual statistique shows a total of 28.000 Tesar transformers working all around the world, underlining the remarkable reliability of our transformers. More than 28.000 transformers actually working

Products: Measurement Transformers Voltage transformers Type: Phase/Earth (included type with fuses holder) Phase/Phase Current transformers Rated current up to 2500 A. Insulation level up to 36 kV. Ring-type transformers cl. 0,72 kV.

Products: Measurement Transformers Voltage transformer Current transformer Ring-type transformer Voltage transformer with fuse holder

Application fields BUILDINGS ELECTRICAL PLANT EOLIAN PLANT OIL PLANT

Application fields AIRPORT SEA PORT RAILWAYS METRO

Installation NORMAL INSTALLATION CONDITION The max. altitude of installation is 1000 m above see level. The ambient temperature in the room, when the transformer is working, must be within the following limits: Minimum temp. : -25°C Maximum temp. : +40°C SPECIAL INSTALLATION CONDITION When requested, transformers are designed for special climatic condition and we guarantee our transformers for an ambient temperature up to +55° C

Design Every design, planning and drawing phase is made using the most up-dated software and CAD instruments: AUTODESK Autocad© Wintrasf 3.0

Rules RULES IEC IEC 60076-1 Power transformer – part 1 : General IEC 60076-2 Power transformer – part 2 : Temperature Rise IEC 60076-3 Power transformer – part 3 : Insulation levels, dielectric tests and external clearances in air IEC 60076-4 Power transformer – part 4 : Guide to the lightning impulse and switching impulse testing - Power transformers and reactors IEC 60076-5 Power transformer – part 4 : Ability to withstand short circuit IEC 60076-10 Power transformer- part 10 : determination of sound levels IEC 60076-11 Power transformer- part 11 : Dry-type transformers IEC TC 14 IEC 60616 Terminal and tapping markings for power transformers HD 538.1 S1 Three-phase dry type distribution transformers 50Hz, from 100 kVA to 2500 kVA with highest voltage for equipment not exceeding 36 kV part 1 general requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV

Components MAGNETIC CORE The magnetic core realized with silicon cold-rolled grain-oriented steel sheet give low specific losses The interweaving system is step-lap type and it is realized thanks to the most modern cut and assembling technologies The proper geometry and strength of the frames, together with the appropriate bolt techniques, enable to obtain low noise level, constant during the time

Components LOW VOLTAGE WINDINGS The LV windings are made using aluminium or copper sheet, with pre-impregnated class F insulating material. The coils are subjected to a thermal treatment of polymerization to obtain the finished product The special constructive geometry allows, moreover an high resistance to the electrodynamic stresses

Components HIGH VOLTAGE WINDINGS The HV windings are composed from more coils in aluminium or in copper (wire or tape) connected together The coils are casted into moulds under vacuum using class F epoxy-resin The casting under vacuum process, electronically monitored, allows to obtain windings with a total resin homogeneity, so free from partial discharges

Department Casting Winding Core Coils Storage Assembling

Tests Main Testing Room In line Testing Room All Tesar products are scrupulously tested in its our modern testing rooms in Chiaveretto plant . Main Testing Room In line Testing Room

Tests In the Tesar testing rooms routine, type and special test are carried out using the most up-dated softwares : Trafotest © Heat run test SP 2K © Type and special test

Accessories ENCLOSURE standard enclosure enclosure with HV- LV cable boxes

Accessories Tesar TSX 1s THERMOCONTROLLER with digital exit RS232 – RS485 transmission protocol Modbus®

Accessories FAN Bar 600 FAN Bar 1800

Accessories COOLING Tesar TSX 2 control board for fan

Transport Tesar transformers are delivered assembled and ready to be connected to the high and to the low voltage network.

Installation AIR FLOW To guarantee the respect of the rated condition of service and to avoid that the temperature rises are passed, in the room where the transformers are installed an air-exchange is necessary to discharge the heat produced during their operation.

Installation SAFETY DISTANCES The transformer supplied without enclosure (IP00) has to be installed in an adequate room respecting the insulation distances showed in the table insulation Distances “D” mm KV Sheet steel wall Louvered wall 7,2 150 300 12 17,5 220 24 240 36 320

Installation HV AND LV CONNECTIONS Transformer without enclosure (IP00) The cable and the bus-bar to be connected to the transformer must be moored in an adequate way to avoid mechanical stresses on LV and HV transformer bushings.

Installation HV AND LV CONNECTIONS Transformer with enclosure (IP20 – IP21 – IP23 – IP31) The cable and the bus-bar to be connected to the transformer must enter the enclosure only through the holes/flanges foreseen during the order stage.

Maintenance Ordinary maintenance A deep check of the transformer during the work allow to avoid damages and to extend the expected life. In normal working condition it is enough to do the following operation one time per year: Clean of the HV/LV windings from the eventual dust, condensation or dirty, with dry air at low pression Clean of the cooling and fan channel between the coil to avoid over temperature during the working Verify the tightness of the bolts and nuts of the HV/LV connections, of the bar of the tap-changer and of the frames Check of the correct running of thermal protection (PT100 or PTC and relevant thermo-controller) and also the correct intervention of the protection for surcharge and for the short circuit and the intervention of the automatic switch

Instrument / Equipment Maintenance Table for periodical check The main periodic checks to be performed on the transformer, the check intervals, the equipment to be used and the results to be obtained are reported in the following table Pos Check to be performed Check Interval Instrument / Equipment Results 1 Cleaning from dust, dirt, unlikely presence on the windings Yearly and/or after exceptional events Dry compressed air and cloths General cleaning 2 Tightening of the bolts of the main and secondary electrical connections Torque wrench Tightening torque see paragraph 5.1. 3 Tightening of the mechanical parts bolts and transformer clamping to the ground 4 Tightening of plate for adjusting the spacer blocks 5 Functioning check of thermo-controller and thermo-resistances Hot air gun for thermo-resistance simulated heating Intervention of the siren of alarm level, opening of switch and trip level 6 Functioning check of the overloading and short-circuit relay Power generator for simulation of damage Opening of the switch on reaching the pre-set threshold. 7 Condensate deposited on the windings After a long transformer stop Hot dry air and cloths Coil surface and internal ducts perfectly dry 8 Insulation check of the windings among them and towards ground Megger with voltage of at least 2500 V Minimum values showed at paragraph 5.2

Main reference in Italy Falck ILVA Nuovo Pignone Piaggio ACEA AEM ENEL Pirelli Ministero della difesa Ministero delle finanze - Roma Metropolitana di Milano Metropolitana di Roma Barilla Buitoni Auchan Alfa Romeo FIAT FIAT Avio Piaggio Iveco Ferrari Pirelli Montedison Ansaldo IBM Zanussi Agip ERG ESSO SNAM Stadio Olimpico – Roma Stadio Meazza – Milano Stadio S.Paolo – Napoli Teatro La Pergola - Firenze Teatro alla Scala – Milano Fiera di Milano Fiera di Bologna Fiera del Levante – Bari Telecom Italia RAI Aeroporto di Fiumicino – Roma Corriere della Sera – Milano

Main reference All over the World Hydro alluminium - Norway Sandvik Steel - Sweden Thyssen Krupp - Germany Magnitogorsk Integrated Iron & Steel - Russia Orly airport Paris - France CERN - Switzerland Wind Mills Power Plant - Danemark Copenhagen metro - Danemark Electrabel - Belgium Aquarium Lisboa – Portugal British Telecom –U.K. Heathrow Airport – U.K. DEWA – Dubai Electricity & Water Authority ADWEA – Abu Dhabi Water & Electricity Authority MEW – Ministry Electricity & Water - Kuwait DCA Dubai Airport - Dubai Deira City Center - Dubai Conference Palace Hotel - Abu Dhabi Shangri-la Barr al Jissah Resort - Oman Mosul Dam Crude Oil Pipeline - Iraq Can and Afsin Power Plant - Turkey FIAT - Brasil Metrovias - Argentina Renault - Argentina Hong Kong Metro – Hong Kong Toshiba Plant - Singapore ST Microelectronics - Singapore