G.E. UPS Productline.

Slides:



Advertisements
Similar presentations
UPS Topologies and Multi-Module Configurations
Advertisements

CL100D series DSP controlled Uninterruptible power supplies.
Increasing the Efficiency of UPS Systems – And Proving It!
Variable Frequency Drives VFD Basics
LP-31 Series Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
Delta Confidential Apr GAIA-series 5-11KVA Introduction.
Zycko’s data centre proposition The very best products and technologies Focus on what your customers need Turning products into solutions Wide range of.
© 2010 Eaton Corporation. All rights reserved. Efficiency + Modularity = the new Green UPS Design Ed Spears.
LP33 Series UPS kVA 400Vac/CE
DPA TM UPScale Best-in-class modular UPS for maximum availability.
Unirom Electronics Presentation
Delta Confidential DES UPS introduction UPS training June 2006 Markus Schwab.
POWER SUPPILES LECTURE 20.
PRODUCTS TRANSFORMERS ENERGY SAVING TRANSFORMERS (EST) TRANSFORMER RECTIFIER UNITS 3 rd HARMONIC REJECTION TRANSFORMERS (HRT) ULTRA HIGH ISOLATION TRANSFORMERS.
UPS series PROTECT 1.M Scalable UPS in n+x technology Modularity with double conversion UPS modules True sine wave - output.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
GE Critical Power © 2010 General Electric Company. All Rights Reserved. This material may not be copied or distributed in whole or in part, without prior.
Expanded UPS product line. The expansion of our UPS offering is intended to give our customers a more complete line of products for most of their installations.
SitePro UPS 400Vac / CE GE Consumer & Industrial August 2004.
“Free Critical Power” for Energy Efficient Data Centers
UPS SG-CE Series kVA Sales presentation.
LP Series 11/31T - Uninterruptible Power Supply Product Management GE Consumer & Industrial Power Protection.
SG-CE Series kVA PurePulse®
AC backup solutions for business continuity. Secure your business, Stay on!
Uninterruptible Power Systems
MarsⅡ On-Line UPS Series
ML Series Product Presentation Product Management May 2004.
ENERGY of 21 st Century Independent Power Supplies.
Page 1 May 2010 © Siemens AG 2010 Industry / Drive Technologies Innovative Hybrid Drive Systems for Commercial Vehicles Industry – Drive Technologies Innovative.
PowerScale 10-50kVA Ed Maximize your availability.
LP Series U Technical presentation ISO 9001 UL CUL FCC Class A CE.
Smart Grid: Opportunities in the Data Center January 22, 2010 Charles O’Donnell, Vice President, Engineering Liebert AC Power Emerson Network Power.
Delivering total power infrastructures worldwide for IBM.
RACK Mountable & Modular Continuous Power Protection Availability
Power Quality Product Overview
LP Series 400V CE GE Consumer & Industrial September 2004.
TLE Series UPS kW CE. Page 2 TLE Series kVA/kW CE Product Range TLE Series UPS kVA/KW 160,200,320,400 kW High efficiency UPS Introducing.
© 2014 Eaton. All Rights Reserved.. Eaton 93PM: Value, Benefits, and Features.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
Data Center Infrastructure Total System Effectiveness Matt Gleason, CoreSite Jim Hughes, Mitsubishi Electrical Power Products.
PRO-H Power Supplies. PRO-H Series  P owerful R eliable O ptimized - H azardous Areas  Complete family of Power Supplies 1-phase 3.8A up to 25A  Output.
© 2007 Eaton Corporation. All rights reserved. Powerware ® BladeUPS Highest efficiency power protection for today’s IT environment.
InfraStruXure Systems Alex Tavakalov
93E Eaton 93E kVA UPS Sales Presentation.
© 2011 Eaton Corporation. All rights reserved. Configuring BladeUPS™
UPS SG-CE Series 300 kVA. SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 2 Product portfolio CE Marked, 3x380/400/415V.
© 2013 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Eaton Power.
A DSP based on on-line UPS R.Padamaja G.Mamatha Reddy EEE EEE S.V.C.E S.V.C.E BY.
Energy Conference and Exhibition 2007 Best Practices for Energy-Efficiency in Critical Power Applications Kit Killingsworth.
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
SMPS.
Increase your efficiency with Schneider Electric
Auxiliary power supply (APS) Hossein Harimi 2014
RACK Mountable & Modular Continuous Power Protection Availability
93E Eaton 93E kVA UPS Sales Presentation.
LV Safe Powering from UPS to Clients
V7 UPS Sales Training.
RACK Mountable & Modular Continuous Power Protection Availability
230 Yuma Street Denver, CO (800)
Power distribution and UPS in a single, compact system
PowerValue 11 RT Sales Presentation
POWER SUPPLIES EQUIPMENT AND SYSTEMS
True modular UPS system for critical applications
Maximize your availability
PowerValue 11/31 T Sales Presentation
Best-in-class modular UPS ensuring business continuity
Anna Brinck, M.S. Student Robert Cuzner, Assistant Professor
Introducing the new 700–3000 VA UPS from Eaton
Robicon Perfect Harmony.
Eaton 93PM: Value, Benefits, and Features
Presentation transcript:

G.E. UPS Productline

Uninterruptible Power Supplies | 1 Phase Delivering reliable power in a compact footprint IT & Match Series GT Series Line Interactive topology, automatic voltage regulation, step-wave output with internal hot swappable batteries. Double conversion, parallel-ready technology with modular battery and power components for easy expansion and retrofit. Application Point-of-sale (POS), ISDN switches PCs, routers, & small IT servers Application Telecom equipment, server racks, small to medium data networks Rating Output Cert. 600 VA – 2 kVA 120 Vac UL 500 VA – 3 kVA 230 Vac CE Rating Output Cert. 1 – 2kVA 120 Vac UL 3kVA 120/208 Vac 5 - 10kVA 120/208/240 Vac 6 & 10kVA 220/230/240 Vac CE VH Series LP11 / LP31T / LP31 Series Double conversion technology, hardened design, peak load handling, and wide temperature operating range. Double conversion, high efficiency (up to 97%) and redundant parallel capable, with galvanic isolation and GE’s battery management for load security. Application Healthcare & marine, wind turbine, controls, all IT & high speed processing Application Medium data networks, telecom equipment, local site protection Rating Output Cert. 2 kVA 208/220/230/240 Vac UL 700 VA-3 kVA CE Rating Output Cert. 5-10 kVA 120/208/240 Vac UL & CE 3-10 kVA 220/230/240 Vac CE 5-20 kVA

Uninterruptible Power Supplies | 3 Phase Clean, reliable and energy efficient power SG Series LP33 Series The high efficiency SG series provides fast step/transient load response while eliminating single points of failure. The LP33 series is a transformer-less design reducing install footprint and installation time. Application Enterprise class data networks, large data centers, healthcare equipment Application Large data networks, telecom equipment Rating Output Cert. 10 - 100 kVA 208 Vac UL 10 - 120 kVA 380/400/415 Vac CE Rating Output Cert. 10 - 750 kVA 480 Vac UL 60 - 500 kVA 400 Vac CE SitePro Leading the industry through innovation The SitePro model is a robust, double conversion UPS that provides true on-line operation and galvanic isolation. Redundant Parallel Architecture (RPA) Increasing reliability by eliminating single points of failure. Paralleling multiple UPS’ for true redundancy without adding complexity. Application Manufacturing & process control healthcare equipment, data centers ECO Mode Power supplied from mains via UPS bypass circuit. Immediate transfer to inverter power during disturbance. Energy efficiency of up to 98.5%. Rating Output Cert. 10 - 40 kVA 380/400/415 Vac CE PurePulse ® Delivers pure clean waveform from the mains, reducing sizing of upfront equipment and eliminating additional input filters.

GE Critical Power TLE Series Platform 225 – 1500 kW

TLE Series platform Introducing TLE Series UPS What is it? TLE Series is a new high power transformer less 3 phase UPS platform with best in class multi-mode efficiency (eBoost and double conversion), and modular scalable from 200 kW up to 1500 kW for global UPS markets (CE and UL). Why is it important? This TLE platform establishes GE technology leadership in mid/high power UPS applications with industry leading differentiation in efficiency, output power capacity and footprint. Differentiated Value Proposition Best in class multi-mode efficiency 96.5% Double Conversion mode (VFI) 99.0% eBoost mode (VFD) Highest output power (up to 1.5 MW) High reliability: Improved serviceability and lower MTTR Standard building blocks 250 kw Inherent redundancy inside UPS module High power density and small foot print Excellent input , output performance 5

Creating Value – Low TCO Ultra High Efficiency Excellent Performance Improved Diagnostic High Reliability High output power Improved Serviceability

Creating Value – Low TCO 1 Ultra high Efficiency

GE Sets the Bar for highest UPS Operating Efficiency High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design Double conversion Efficiency – 96.5% High efficiency performances High efficiency at full and partial loads for real benefit in operating conditions Energy cost saving Reduced cost of customer equipment operation at all loads Air conditioning cost saving Reducing size and cost of air condition system Reducing consumption and related operating cost GE Sets the Bar for highest UPS Operating Efficiency 8

High Efficiency – eBoost mode eBoost high efficiency (up to 99%) fast transfer to inverter <2ms "GE's eBoost feature expands a classic mode On-Line Double Conversion UPS System to a multi-mode UPS capable of maximizing operating efficiency commensurate with the stability of utility voltage and frequency eBoost can be operated in RPA mode, up to 6 UPS modules in parallel, with all units operating and switching as one through redundant communication bus

High Efficiency – Low TCO Assumptions: Power cost = $ 0.10 /kw-hr Operating hours/year = 8760 Cooling factor = 0.35 Configuration = S+S operating at 50% load High efficiency up to 96.5% Considerable life cycle cost savings Reduction in UPS operating cost Reduction in cooling cost 93% 96.5% 99% 5 MW IT load - TLE series life cycle savings of $1.5 MM while operating in VFI mode

High Efficiency – Low TCO High efficiency up to 96.5% Considerable life cycle cost savings Reduction in UPS operating cost Reduction in cooling cost Assumptions: Power cost = $ 0.10 /kw-hr Operating hours/year = 8760 Cooling factor = 0.35 Configuration = 500 kW UPS @ 50% load TLE Series UPS annual savings Compared to 92% efficiency UPS > $ 14,980 94% efficiency UPS > $ 8,140 95% efficiency UPS > $ 4,830

Creating Value – Low TCO 2 Excellent Performance

Best in class input performance UPS input performances Total Current Harmonic Distortion – THDi <5% UPS input power factor: 0.99 Constant behavior at all loads Negligible harmonics contents at full and partial loads Programmable Soft Start Feature Benefit on input mains Saving in the sizing of upfront equipment e.g. GenSet, cablings, circuit breakers, … No disturbances to nearby equipment Saving cost due to additional filters

Input performances benefit High input performance means saving: GenSet size ( From 2 X Load kVA to 1.3 X Load kVA) - Stable & longer life due to absence of harmonics Circuit breaker size Cabling section/size Investment & space Improved life for nearby equipments No reactive power – saves on power compensation

UPS output power capability Power capability – Unity power factor (kVA = kW) Designed to supply real power for Unity power factor data centers load Suitable for modern power supply application with unit or capacitive power factor (e.g. new servers generation), crest factor up to 3:1 No output voltage distortion with linear and non-linear loads Voltage distortion - linear loads: THDv < 2-3% - non-linear loads: THDv < 5% 11% more kW power compared to UPS with PF=0.9

UPS Input-Output Performance Module size optimization/ Electrical infrastructure utilization 4000 A Input Bus 3000 A Input Bus 2000 A Input Bus 6 x TLE 500 kW 4 x TLE 750 kW 3 x TLE 1000 kW 2 x 1500 KW 4 x TLE 500 kW 3 x TLE 750 kW 2 X 1000 kW 3 x TLE 500 kW 2 x TLE 750 kW 1 x 1500 kW 3 MW Power 2.25 / 2 MW Power 1.5MW Power 11% more kW power compared to UPS with PF=0.9 Competitors units with 0.9 power factor provides less output power from same input bus size

Creating Value – Low TCO 3 Improved Diagnostic High Reliability

New FLEX DSP board: the black-box WAVEFORMS Inverter voltages Bypass voltages Input mains voltages Output voltages: Output current Phases: Input capacitors “Cin” voltages: Inverter primary current: Input current: IDC current: Battery current: Bypass current: UDC Communication status RPA Auxiliary status SSM status Fuses status Phase error slave master. Waveform capture, diagnostic and trend analysis Simultaneous acquisition of 32 channels Sampling frequency up to 10kHz Smart trigger capability with up to 16 indipendent trigger sources to record only specific events with pre/post trigger data acquisition Buffer depth of 1000 samples per channel: each event is recorded for 100ms @ s.f. 10kHz 8 buffers to record up to 8 events without losing older events – can be extended with external USB mass storage devices

4 Ease of Installation Improved Serviceability Creating Value – Low TCO 4 Ease of Installation Improved Serviceability

Compact design Reduced footprint TLE Series 250 kW Reduced footprint Compact design saving space in installation - 225-250 kW: (w x d x h) 44.4 x 33.9 x 75.1 inch -400-500 kW: 66.9 x 33.9 x 75.1 inch Standard Top-bottom cable entry Easier to handle High power density Savings in installation space 1907 / 75.1” 1100 / 43.3”

Improved serviceability Improving Mean Time to Repair & Installation Front access construction/design Draw out construction for fans & power modules Common 250 kW power block & common components Faster power block MTTR Easy access to customer connections Easy access to connectivity Improved diagnostic capability iUPS Guard – Remote monitoring Standard back feed protection Internal Option - Q2 (TLE 250-500) External Option – Q2 (TLE 750 -1500)

Installation flexibility – RPA Cable Saver Bypass input to UPS 1A 2A 1B 3A 2B 3B Competitors – 1A=2A=3A and 1B=2B=3B or max 10% difference TLE Series with inductor = allows variation up to 20-25% (depends on UPS rating & cable section Output from UPS

Advanced User Interface Menu driven touch screen 7” display Critical measurement of input, output and battery included with mimic diagram Quick operational status Different access level for user and service Different mimic diagram based on configuration Multilanguage communication interface Metering Alarm Set up Command RPA System

Advanced User Interface Menu driven touch screen display

Advanced User Interface Menu driven touch screen display Separate screen for RPA system with status and measurements Metering screen by tabs Home button inside each screen Improved alarm and events screen Easy to use set up screen

Creating Value – Low TCO 5 Summary

Limited life component monitoring Differentiated TLE Series UPS Efficiency Black Box Limited life component monitoring High Reliability Small foot print Product options Font access New control panel Draw out construction 96.5% THDi 3-5%, Input pf 0.99 Output pf -1

TLE Series UPS Differentiating: Best in class double conversion efficiency - up to 96.5% Ultra high efficiency in eBoost mode of operation - up to 99% Static bypass inductor Compact foot print provides very high power density Excellent input, output performance Improved diagnostic capability with black box Ease of installation and Improved serviceability

High Efficiency at all loads Reduced customer operation costs and cost saving in air conditioning design 3-Level topology High efficiency performances The TLE Series UPS uses a three level technology with an Advanced Neutral Point Clamped topology implemented with true Reverse Blocking IGBT. These result in reduced switching and filter losses with respect to a standard two level technology 29

Improved diagnostic, High Reliability Improving Reliability & Diagnostic AC Capacitor health monitoring Component life time counters Dedicated supply path for bypass logic Redundant Isolated power supply Robust RPA communication No total OFF button to avoid human error Heat sink & input, output filter coils temperature monitoring Improving Mean Time to Repair Wave form capture capability Fan failure detection

UPS configuration Double conversion (VFI) technology Optional – TLE Series 225-500 kW TLE Series 225-500 kW Double conversion (VFI) technology Automatic bypass for overloads, short circuit and UPS disturbances conditions Manual bypass Q2 (optional) for UPS maintenance operations without load interruption (225-500 kW internal option) Standard common mains Number of battery blocks – 40-42 - back feed protection K6 standard

Installation flexibility - Product options Supplemental Cabinetry VRLA Battery Cabinet Systems Flywheel DC Energy Storage 480/480V External Maintenance Bypass 480/208V External Maintenance Bypass (250kw max) Optional Equipment 480/415VAC Input Isolation Xfmr 600VAC Input Isolation Xfmr Remote Alarm Status Panel Dual Input RPA Card for parallel operation eBoost Software for multi-mode operation ISM (intelligent Synchronization module) – not supported

Remote monitoring – TLE Series iUPSGuard – Remote monitoring Improved response time 24 x7 monitoring & alarm notification of UPS Improved pre dispatch diagnostic & first time fix Regular status reports Highly secure communication

Customer Connectivity Easy integration with Building Management System (BMS) UPS supervision capability 1x RS232 Serial Communication Port 6 programmable potential free alarm contacts: - D plug - Terminals blocks 1x Emergency Power OFF contact 1x Gen-ON Input contact 1x Control Input contact Additional interface: SNMP Interface Card (10/100Mbps auto-select) MODBUS Interface (RS232 or RS485) iUPSGuard (free license during warranty) - SNMP card required for iUPSGuard Customer interface

Redundant Parallel Architecture System reliability improved by RPA Configurable up to 6 units in parallel Future expansion Safe and reliable power supply Redundant Communication Bus Easy to install and maintain Easy system upgrade/downgrade Maintenance operation without load interruption RPA cable saver allows installation flexibility