LIST® Linear Sensing of Temperature

Slides:



Advertisements
Similar presentations
CL100D series DSP controlled Uninterruptible power supplies.
Advertisements

سیستم آلارم دیجیتالی مجهز به ثبات خطا
Inductive Capacitive Optical Infrared Flow Temperature Sensors for Automation.
Welcome to the information pages of the LIST linear fire detection system.
Smart heat for comfort and safety 1 Self-regulating system to maintain water flow in gutters and downpipes.
LIST® Linear Sensing of Temperature
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Basic Jens Neigaard.
VAMP 300 IED functionality Feeder relay Motor relay
Model B1 19-inch Rack Static Transfer Switch. Why choose a model B1 static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
1 Strictly confidential | Engineering| © Robert Bosch GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of.
 Salient characteristics / Approvals  Non-illuminated Switches  Illuminated Switches  Pilot Lights  Contact Elements Control & Signalling Devices.
Chapter 7 Input Modules.
EUT 1040 Lecture 10: Programmable Logic Controllers.
GST FIRE ALARM SYSTEM INTERNATIONAL BUSINESS DEPARTMENT , GST BEIJING
07 October ‘04 JCOV R. Lindner Water leak detection at LHCb Detection of cooling water leaks below electronic racks.
You Can Measure the Benefits… Training Course Introduction to SmartScan.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
Dry type transformers Zaragoza Accessories and options
PLC Fundamentals Module 2: Hardware and Terminology.
SF-3000 Installation Manual. 2 Back of SF CON400) USB connector - User can use USB memory stick after connect USB connector of key PCB. CON500)
1  Module Type Overview  Construction  Characteristics  Installation principles  Details PD 600-Series.
Module 2: Hardware and Terminology
Alarmline Linear Heat Detection
Main Water Leak Detection Panel (SY3618) Features: 1.Operates on 230 V A.C. 2. Provides supervision of Interface modules. 3. LCD display to indicate Module.
Linear Heat Detection.
A BRIEF INTRODUCTION TO FIELDBUS 4 hf NETLOGIC PLC TRADITIONAL CABLING SYSTEM TERMINAL BOARD.
Features: ERTL TESTED  Displays distance to leak location in meters.  Indicates Cable break condition.  Modbus Output for BMS Monitoring.  Operates.
1 PAC530 | Output Controller. 2 The Output Controller (PAC530) provides the local connection on an RS-485 network between an Access and Alarm Server (PAC500)
TRANSMITTERS OLCT80. OLCT 80 d or id (with intrinsic safety sensor block) n II2GD n For combustible and toxic gases and oxygen n Fitted with pre-calibrated.
Modular Inverter.
Your Connectivity Partner. Locations Main Office: High Tech Products Lallio, Italy USA Office: HTP Connectivity Parsippany, NJ.
Computer Hardware A computer is made of internal components Central Processor Unit Internal External and external components.
Dupline Hi-Line Irrigation Control Jens Neigaard1.
CUE – Make Any Pump an E-Pump
Service Section Technical Training December 2005.
FIREPOWER BY SABURKE. Distributed Power Modules Model 5495Model Amps9 Amps.
PLC ARCHITECTURE – Memory 2 by Dr. Amin Danial Asham.
Multiple Module Vacuum Oven Productivity Enhancement System.
PROGRAMMABLE LOGIC CONTROLLER
2 Wire Door Entry System (DES of MH BT offer)
SEMINAR ON P.L.C. SUBMITTED BY HRIDAY MUKHERJEE AMIT DEBNATH SOMNATH SHIL
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Broadcasting devices. Broadcasting devices overview USB Power Monitor, type channel, 4-line display, USB, Digital out, Opto out WEB Power Monitor,
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
GmbH Specialist hotel application ComplianceCommercial refrigeration Industrial refrigeration Light Industrial Gas Detection MGS-550 Product Portfolio.
HighPROTEC-2 MRA4-2 Directional Feeder Relay Sales presentation
Serial / Ethernet Converter - IE-CS-2TX-XRS232/485
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
Chapter 7 Input Modules. Objectives (1 of 2) Explain the differences between positive and negative logic and sinking and sourcing. Describe the available.
Lecture 10: Programmable Logic Controllers
ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX Weather Unit, Weather Sensor
HighPROTEC-2 MRM4-2 Motor Protection Relay Sales presentation
ABB i-bus® EIB / KNX Analogue Input AE/S 4.2
HighPROTEC-2 MCDTV4-2 Transformer Protection with differential Sales presentation 2015/08/10.
Zone Terminal MT/U Technical Overview
Security Module, MDRC SCM/S 1.1
FEEDER PROTECTION UNIT
Session III Architecture of PLC
Analog Room Command Module
HighPROTEC-2 MRDT4-2 Transformer Protection with differential Sales presentation 2015/08/10.
PLC’s Are ... Similar to a Microcontroller: Microprocessor Based
Customer Presentation
Customer Presentation
GMA Gas detection system
MULTI - DPG.
EUT 1040 Lecture 10: Programmable Logic Controllers Unrestricted.
Presentation transcript:

LIST® Linear Sensing of Temperature LISTEC® GmbH LIST® Linear Sensing of Temperature LISTEC und LIST sind eingetragene Warenzeichen Ein Unternehmen der Securitas Gruppe Schweiz 1

LISTEC® GmbH Design and Principles LIST System Karlheinz Tank Mai 2014 2

Basic LIST system SEC 20, CBO and LISTcontroller 3

LISTcontroller 19“ 1U rack Non-volatile Timer LISTcontroller Housing Power supply 24 V DC Displays LEDs, LCD Processors 3 Memory for lists Non-volatile Timer RTC (Goldcap) Interfaces 4 (2x RS232, RS485, LAN) Cable lengths 3.200 m (+ max. 300 m connection line) Sensors 320 Groups 254 Group relays 256 Redundance / Loop Yes 4

Cable design SEC 20 Cable jacket Aluminum shield Filler material Sensor Flexible flat cable Strain relief 5

SEC 20 SEC 20 4 wires min. 0,5 meter -40 °C to 85 °C Cable design 4 wires Sensor spacing min. 0,5 meter Standard spacing 2, 4, 5, 8 and 10 m Measuring range -40 °C to 85 °C Sensor cable weight 0,45 kg/m Connection At the beginning of each single sensor cable , a connection box shal be provided, in which the connectioncable connects the Listcontroller to the sensorcable via CCM connection module. Connection boxes CBO 20 6

Imprint – Address – Sensor number Address (fixed) Logical sensor number (Programmable) 7

SEC 20 - Imprints 3-digit Sensor imprint Cable number yyy = Batch number Imprint 1: Imprint 2: Imprint 1 Imprint 2 180 ° 8

Measuring cycle Measurement Read Temperatures Test Evaluation Alarm? Protocol output Set alarm relay 9

Addressing / Data reception SEC 20 Digital addressing Analog data 10

Addressing - Advantages Branchable Bidirectional No termination necessary Free numbering System with different sensor distances possible 11

Test - Plausibility Validity of temperatures Temperature jumps 12

Alarm evaluation: Maximum temperature alarm LISTcontroller (FprEN 54-22:2012: Response class A1N and A2N) Message Standard value Scope Pre- signal Warning max. 90% of maximum - threshold value Device Alarm Firealarm! 55°C Group LISTcontroller (FprEN 54-22:2012: Response class BN) Message Standard value Scope Pre- signal Warning max. 90% of maximum - threshold value Device Alarm Firealarm! 70°C Group 13

Alarm evaluation: Reference profile Reference value adjustment / sensor for ambient temperatures with normal temperature development. Temperature (°C) Measuring Cycle Current temperature Reference temperature 14

Alarm evaluation: Differential temperature alarm Quick rise of environmental temperature leads to differential temperature alarm.   - Reference Temp. - Current Temp. Pre-signal HEATING Alarm  FIRE! - DT 15

Alarm evaluation: Differential temperature alarm LISTcontroller (FprEN 54-22:2012: Responseclass A1N, A2N and BN) Message Standard value GScope Pre signal T-increase 50% of Difference temperature threshold Device Alarm Fire alarm 2,5 K Group 16

Maximum Differential temperatures Help for the adjustment of the Difference temperature thresholds One table per section/group Maximum 8 entries per table With a simultaneous increase of several differential temperatures in a section, only the highest value is recorded One Table per section (group), helps for the manual, later adjustment of the diff value, if there are false alarms 17

Alarm evaluation response times (FprEN54-22) (LISTcontroller) Heat- response- class Application- temperature Static Response- TF6S TF6 TF6F Typical Maximum Minimum Response time Lower value Upper °C s R O O M M O N I T O R I N G A1N1 25 50 54 65 400 30 210 20 130 A2N1 70 120 600 60 300 40 180 OB J E C T M O N I T O R I N G BN2 69 85 18

Frost-alarm evaluation LISTcontroller Information Standardvalue Scope Pre-signal Frost warning 5°C above Frostalarmthreshold Device Alarm Frost alarm -40.0°C (no evaluation) Group System does not work below -40°C 19

Connection boxes for SEC 20 Size: 244 mm x 164 mm Protection class: IP66 Material: fibre-glass reinforced polyester Accessories: Closing caps, fittings, installation instructions CBO 20/0 connection of 2 detectio cables, 20/1 = connection of 2 detectio cables + CC connection CBO 3 = 2 Connectionmodules for 4 SEC 20 + cc connection CBO 20/0 CBO 20/1 CBO 20/3 20

Sensor cable fixings Polyamid cable clip CLIC TOP 17 MDP 20 (CLIC TOP 17 with plastic plug and A4 screw) 21

Sensor cable fixings MDJ Stainless steel installation clip (Wst. 1.4571, metal sheet thickness 1,5 mm) MDJ 40 Clip with stainless steel anchor, -nut and -cable-tie MDJ 22

Signalisation: Collective relays Alarmtype LISTcontroller Firealarm  Presignal Frostalarm Fault 23

Signalisation: Group relays Alarmtype LISTcontroller Firealarm  Presignal Frostalarm Fault 24

Signalisation: Relays Relay outputs are codable via bridges / resistors as: Normally open contact (NO) Normally closed contact (NC) For closed current supervision 25

Signalisation: Interfaces LISTcontroller RS232  RS485 LAN (Ethernet) USB 1 USB for firmware update SEC Controller, downloading maintenance files from controller 1 Only for FAT formated storage devices. 26

Signalisation: Protocols LISTcontroller Modbus TCP  Modbus (Seriell)1 1 IEC 60870-5-104 LIST2 3964R IEC + 3964 are special protocols 1RS232 2LISTgraph II Visualisation, Master / Slave communication 27

Signalisation: Modbus LISTcontroller (TCP / RS232) Number of parallel requests 4 / 1 SENSOR Sensor number range1 1 - 6499 Temperature / Sensor  Status / Sensor: Fire-, Presignal, Fault, Switch-off Group Range of groupnumbers 1 - 254 Temperature mean value / Group Status / Group: Fire-, Pre-signal, Fault Switch-off/Switch-on/ Group 1 Sensor nummer = freely selectable number 1Distributed over several devices 28

Signalisation: Modbus LISTcontroller (TCP / RS232) Device Number of devices 247 / 1 Fault status / Device  Collective-Alarm / -Fault Reset Sound off RDT: Status Revision switch-on-/off Time Synchronisation 29

Thank you for your Attention!