Why do people live in Florida?. Florida population 1900 to 2004.

Slides:



Advertisements
Similar presentations
TORO ID PRE COOLER (Patent Pending) for Air Cooled Condensers Improving Cooling Efficiency and Energy Conservation in Air Cooled HVAC Systems.
Advertisements

Formulas.
Arizona Priority Lists Charlie Gohman Az Dept of Commerce Energy Office.
Berkeley Solar Group Enercomp, Inc. Maximum Allowable Cooling Capacity Bruce Wilcox, BSG Ken Nittler, Enercomp.
Your panelists Benefits, Technologies & Services: Mike Carter and Mark Farrell, Energy Engineers.
Lindbergh Field International Airport New Terminal Bill Mahoney LSW Engineers.
GY205 Weather and Climate Lecture 3.
A/C Final Project: Design Builder
Operating Functions.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – July 2012eere.energy.gov Building Science Basics WEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS.
Heating, Ventilating, and Air-Conditioning
100% Outside Air and Dehumidification Management
HVAC 101 The Basics of Heating, Ventilation and Air Conditioning
Department of Energy Energy Savers PowerPoint: Heating and Cooling 4 of 12.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
Heating and Air Conditioning I
Chilled Beam Presentation
Tennessee Technology Center Center at Pulaski. Superheat & Sub-cooling A Technician’s Guide to HVACR Diagnostics.
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov Energy Movement WEATHERIZATION ENERGY AUDITOR SINGLE FAMILY.
Energy Efficient Heating and Cooling Systems For Today Geothermal Heating, Cooing And Hot Water Systems.
Presentation for Florida Building Commission Regional AC Efficiency Workgroup May 9, 2008 Lennox Industries Inc.
Station 4 ?? Temperatures and Moisture Moisture Meters Pin Contact Data Loggers Spot Temperature Meter Thermal Imager Cautions and Safety.
Airflow Properties & Measurement
Presented by: Terry Stohs Viessmann Manufacturing Company Inc.
C A L I F O R N I A E N E R G Y C O M M I S S I O N 2013 Building Energy Efficiency Standards Residential Zoned AC Discussion August 18, 2011.
AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS
HVAC Systems Overview HVAC Overview - # 1 Tom Lawrence
Air Conditioning. Definition: Any treatment of the environment air within a building is air conditioning. Air cooling is any process that reduces air.
Dual Fuel + Hybrid System Selling.
Refrigeration and Cooling Principles for Potato Storages
The Energy Star Home Drew Tepper. Overview What is an energy star home? What is an energy star home? New Homes New Homes Existing Homes Existing Homes.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
F LORIDA S OLAR E NERGY C ENTER A Research Institute of the University of Central Florida Assessment of Energy Efficient Methods of Indoor Humidity Control.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Conditioning of Moist Air
Important variables Water: Air: Conversion:
Part 2: Buildings as a System Lee F. Ball Jr., PhD
Air Handler Terminology
Refrigeration and Cooling Principles for Potato Storages Roger Brook Professor and Extension Engineer Agricultural Engineering Department Michigan State.
Objectives Define psychrometric quantities Continuation from previous class Draw psychrometric processes Relate psychometric variables to human comfort.
 On average, home heating uses more energy than any other system in a home  About 45% of total energy use  More than half of homes use natural gas.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Dehumidification Justin Dunnahoo.
Water is the Natural Choice Water: The Natural Choice For Efficiency – Unit efficiency versus Building System efficiency – Equipment Ratings EER and COP.
Water is the Natural Choice Water: The Natural Choice For Efficiency – Building System efficiency not just a unit rating – Equipment Ratings EER and COP.
A New (Rational) Way To Condition Air (and Save Energy) AEE, Philadelphia February 18 th 2016 Andrew Mongar, President, AirGreen LLC.
Best practice small scale commercial refrigeration, optimisation strategies and simple maintenance Michael Bellstedt, Minus40 Pty Ltd.
Control Systems: Circuitry Electricity for Refrigeration, Heating and Air Conditioning 7th Edition Chapter 16 Control Systems: Circuitry and Troubleshooting.
The key to comfort and reduced fuel use for all heating and cooling The key to comfort and reduced fuel use for all heating and cooling.
Maria’s Restaurant Chapter 2 Section 6
Maria’s Restaurant Chapter 2 Section 9
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
BASIC PRINCIPLES OF AIR CONDITIONING
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
Maria’s Restaurant Chapter 2 Section 8
Conduction Cooling Loads
Munters DOAS, Chilled Beams and VRV
Brian Wallingford, Applications Engineer
Introduction – Who am I? Environmental Project Manager – Trident Technical College Mechanical Engineer Licensed Builder South Carolina Accredited Commercial.
Variable Refrigerant Volume
High Performance HVAC Installation
Technician’s Guide and Workbook for Zoning Section 1: Introduction
Zoning Load Calculations
The key to comfort and reduced fuel use for all heating and cooling
Zoning Methods There are an unlimited number of ways to zone a home! Popular ways include: More than one single zone HVAC system. Zone damper systems.
FBE03: Building Construction & Science
Maria’s Restaurant Chapter 2 Section 9
Maria’s Restaurant Chapter 2 Section 8
Presentation transcript:

Why do people live in Florida?

Florida population 1900 to 2004

What happened in the 1960s that would have spurred all this population growth? What happened in the 1960s that would have spurred all this population growth?

A/C! (Central Air Conditioning) A/C! (Central Air Conditioning)

What is the object of A/C? 1. Comfort! 2. Comfort ! 3. Comfort!

But with the comfort… When electricity was plentiful and cheap people didn’t care what the efficiency was, just cooling. When electricity was plentiful and cheap people didn’t care what the efficiency was, just cooling.

But there is a price to comfort Once the basics are in place then what? Once the basics are in place then what? 1.Better comfort – humidity control! 2.Better efficiency – less cost to operate 3.Better controls – programmable T’stats

“Better?” You drive a car that you selected on several parameters? You drive a car that you selected on several parameters? 1.Size 2.MPG 3.4-wheel drive? 4.Towing? 5.Number of seats?

A/C is similar Parameters: Parameters: What size and type system is optimal for my house? What size and type system is optimal for my house? 1.People load 2.Temperature requirements 3.Fenestration 4.Efficiency, SEER (mpg) 5.Ability to remove humidity 6.SHR (Sensible Heat Ratio)

A/C is different than a car If you don’t like the car… trade it in! If you don’t like the car… trade it in! You are “stuck” with the A/C for 10+ years, so getting things correct the first time (and every time) is key. You are “stuck” with the A/C for 10+ years, so getting things correct the first time (and every time) is key.

What is the A/C “load”? Not to make you an engineer, but this is of paramount importance to what is trying to be accomplished Not to make you an engineer, but this is of paramount importance to what is trying to be accomplished 1. Heat total = Heat Sensible + Heat Latent 2. Heat Sensible – what you measure with a dry bulb thermometer, what you sense 3. Heat Latent – moisture, humidity

Latent Heat Latent heat is actually MORE important than sensible heat to achieve our goal – comfort If the temperature is 90 and the rh is 15% people say they are comfortable If the temperature is 72 and the rh is 80% people are uncomfortable

SHR Defined as the Hs/Ht Defined as the Hs/Ht

SHR Typical house heat “loads” before the introduction of very efficient windows were approx SHR Typical house heat “loads” before the introduction of very efficient windows were approx SHR

SHR Defined as the Hs/Ht Defined as the Hs/Ht Typical house heat “loads” before the introduction of very efficient window were approx SHR Typical house heat “loads” before the introduction of very efficient window were approx SHR This is good since most equipment produced has a SHR of between 0.80 and 0.70 This is good since most equipment produced has a SHR of between 0.80 and 0.70

SHR Defined as the Hs/Ht Defined as the Hs/Ht Typical house heat “loads” before the introduction of very efficient windows were approx SHR Typical house heat “loads” before the introduction of very efficient windows were approx SHR This is good since most equipment produced has a SHR of between 0.80 and 0.70 This is good since most equipment produced has a SHR of between 0.80 and 0.70 Life was GOOD! Life was GOOD!

What Changed? The introduction of efficient windows and increased insulation changed the load The introduction of efficient windows and increased insulation changed the load

What Changed? The introduction of efficient windows and increased insulation changed the load The introduction of efficient windows and increased insulation changed the load The SHR of a typical house with “low-e” glass is now below 0.65 The SHR of a typical house with “low-e” glass is now below 0.65

What Changed? The introduction of efficient windows and increased insulation changed the load The introduction of efficient windows and increased insulation changed the load The SHR of a typical house with “low-e” glass is now below 0.65 The SHR of a typical house with “low-e” glass is now below 0.65 Some houses approach 0.53! Some houses approach 0.53!

What Changed? The introduction of efficient windows and increased insulation changed the load The introduction of efficient windows and increased insulation changed the load The SHR of a typical house with “low-e” glass is now below 0.65 The SHR of a typical house with “low-e” glass is now below 0.65 Some houses approach 0.53! Some houses approach 0.53! Very few A/C (heat pump) systems are designed to operate with this low a SHR, less than 10% of systems Very few A/C (heat pump) systems are designed to operate with this low a SHR, less than 10% of systems

What limits Heat latent? Why not just build systems with more latent heat capacity? Why not just build systems with more latent heat capacity?

What limits Heat latent? Water Water

What limits Heat latent? Water Water Water has a habit of freezing at 32 F Water has a habit of freezing at 32 F

What limits Heat latent? Water Water Water has a habit of freezing at 32 F Water has a habit of freezing at 32 F When the evaporator coil temperature approaches 32 sections of the coil freezeWhen the evaporator coil temperature approaches 32 sections of the coil freeze

What limits Heat latent? Water Water As a section freezes airflow stops and the coil temp plummets…more ice developsAs a section freezes airflow stops and the coil temp plummets…more ice develops

The “problem” with Latent Heat Latent heat is more difficult to remove than sensible heat Latent heat is more difficult to remove than sensible heat With a non-variable speed AHU it takes some 5-minutes of run-time to reach dewpoint (removing moisture) With a non-variable speed AHU it takes some 5-minutes of run-time to reach dewpoint (removing moisture) Until the “heat of the afternoon” A/C typical thermostats operate on a 6- minute cycle. Until the “heat of the afternoon” A/C typical thermostats operate on a 6- minute cycle.

Equipment Sizing For the A/C system to remove humidity it requires “run time” of the compressor For the A/C system to remove humidity it requires “run time” of the compressor This brings up the subject of equipment sizing This brings up the subject of equipment sizing

Oversizing - What happens? 1. Equipment is larger, more 1 st cost 2. Ductwork needs to be larger 3. More refrigerant in system 4. Less run time, cycles in afternoon 5. Think, late afternoon rain, moderate temperature (76 F), ULTRA high humidity (99%), NO RUN TIME, no dehumidification

Oversizing, common? One study researched some 1600 homes, throughout Florida, what percentage of these homes did they determine to be oversized at least ½ ton? ______% One study researched some 1600 homes, throughout Florida, what percentage of these homes did they determine to be oversized at least ½ ton? ______%

Early Methods of Sizing, some still employ this method due to simplicity of use Look through hole to determine exact size

What is Manual J An engineering method for non-engineers to arrive at consistently accurate heat gain and heat loss calculations. An engineering method for non-engineers to arrive at consistently accurate heat gain and heat loss calculations. Manual J is a “best estimate” of the true heat transfer characteristics of a house Manual J is a “best estimate” of the true heat transfer characteristics of a house From these calculations the correct, best fit, cooling and heating systems may be selected From these calculations the correct, best fit, cooling and heating systems may be selected

Why do contractors oversize? Fear, lack of confidence in ability to accurately determine load (Manual J) Fear, lack of confidence in ability to accurately determine load (Manual J)

Why do contractors oversize? Fear, lack of confidence in ability to accurately determine load (Manual J) Fear, lack of confidence in ability to accurately determine load (Manual J) Expectation of customer, “I had a 4-ton in my 1800 sq. ft. house, this is 2400, I need 6-tons!” Expectation of customer, “I had a 4-ton in my 1800 sq. ft. house, this is 2400, I need 6-tons!”

Why do contractors oversize? Fear, lack of confidence in ability to accurately determine load (Manual J) Fear, lack of confidence in ability to accurately determine load (Manual J) Expectation of customer, “I had a 4-ton in my 1800 sq. ft. house, this is 2400, I need 6-tons!” Expectation of customer, “I had a 4-ton in my 1800 sq. ft. house, this is 2400, I need 6-tons!” Low temperature requests from GC or homeowner, “I like it 65 degrees!” Low temperature requests from GC or homeowner, “I like it 65 degrees!”

Why do contractors oversize? Fear, lack of confidence in ability to accurately determine load (Manual J) Fear, lack of confidence in ability to accurately determine load (Manual J) Expectation of customer, “I had a 4-ton in my 1800 sq. ft. house, this is 2400, I need 6-tons!” Expectation of customer, “I had a 4-ton in my 1800 sq. ft. house, this is 2400, I need 6-tons!” Low temperature requests from GC or homeowner, “I like it 65 degrees!” Low temperature requests from GC or homeowner, “I like it 65 degrees!” That unit ran all afternoon, my electric bill will be astronomical…not necessarily That unit ran all afternoon, my electric bill will be astronomical…not necessarily

Relative Humidity is the DRIVER! Rh is the key to most of the comfort issues with A/C! Rh is the key to most of the comfort issues with A/C! Rh above 60% is considered high, below 48% is low, 50-54% is “just right” Rh above 60% is considered high, below 48% is low, 50-54% is “just right”  Think “Goldie Locks” rule, Rh not too high, not too low… just right!

What is the optimum humidity? The reality in Florida is: humidity levels less than 55% are good, less than 52% great. A driver on humidity with modern tight construction is how the occupants live. Do they use bath exhaust fans, kitchen hood exhaust when cooking steam producing foods, etc? 52% rh

13 SEER and higher The “law of unintended consequences” The “law of unintended consequences” EER = Btuh/watts, 80/67 and 95 OD EER = Btuh/watts, 80/67 and 95 OD SEER is an integrated value not just the standard rating point from above SEER is an integrated value not just the standard rating point from above Higher SEER does NOT mean comfort, you must design by SHR for success Higher SEER does NOT mean comfort, you must design by SHR for success

How to achieve higher SEER Remember Btuh/watts Remember Btuh/watts By decreasing latent heat (higher SHR) and shifting capacity to Hs the system will achieve higher SEERBy decreasing latent heat (higher SHR) and shifting capacity to Hs the system will achieve higher SEER

How to achieve higher SEER Remember Btuh/watts Remember Btuh/watts By decreasing latent heat (higher SHR) and shifting capacity to Hs the system will achieve higher SEERBy decreasing latent heat (higher SHR) and shifting capacity to Hs the system will achieve higher SEER Some inexpensive “high SEER” systems typically do not dehumidify well (high SHR)Some inexpensive “high SEER” systems typically do not dehumidify well (high SHR)

Result The percentage of cooling that is temperature reduction increases and the moisture removal is reduced, as a percentage of the total (change of the Sensible Heat Ratio – SHR higher) The percentage of cooling that is temperature reduction increases and the moisture removal is reduced, as a percentage of the total (change of the Sensible Heat Ratio – SHR higher) This is great…if you live in Arizona…if you live in Florida…terrible! This is great…if you live in Arizona…if you live in Florida…terrible!

Cardinal Glass Industries Houston Demo Houses 3 Identical Homes With Different Windows SHGC = 0.62 SHGC = 0.62 (single pane) SHGC = 0.52 SHGC = 0.52 (double pane) SHGC = 0.34 SHGC = 0.34 (low solar gain low-E) courtesy of the Cardinal Glass Industries

Air Conditioner Sized with Windows Single Pane 4 ton 4 ton Double Pane 3.5 ton 3.5 ton Low Solar Gain Low-E 2.5 ton 2.5 ton courtesy of the Cardinal Glass Industries

Windows are the key! The fenestrations (windows) are the largest component in the A/C load. Having solar as well as a transmission heat gain component The fenestrations (windows) are the largest component in the A/C load. Having solar as well as a transmission heat gain component Since this component is subject to multiplication later in the Manual J program any error will be multiplied as well Since this component is subject to multiplication later in the Manual J program any error will be multiplied as well If the window data is correct in size, quantity and heat gain data input, and orientation, the output data has greater credibility If the window data is correct in size, quantity and heat gain data input, and orientation, the output data has greater credibility

Why is correct sizing and SHR essential? You entertain the distinct possibility to MOLD a structure if the A/C is improperly sized. You entertain the distinct possibility to MOLD a structure if the A/C is improperly sized. Too small isn’t the problem! You may not be able to keep the house 75 degrees at the rare 97 degree outdoor… Too small isn’t the problem! You may not be able to keep the house 75 degrees at the rare 97 degree outdoor… Too large is! Shorter than standard run time equals higher relative humidity (rh) Too large is! Shorter than standard run time equals higher relative humidity (rh)

The mind of the Home Buyer You cheated me! The house next door has a 4-ton unit and I have a 2 ½, you better increase it to 5-tons or I’m going to sue! You cheated me! The house next door has a 4-ton unit and I have a 2 ½, you better increase it to 5-tons or I’m going to sue! But Mr. Homeowner you have: But Mr. Homeowner you have: 1. Different exposure 2. Low e-glass 3. Better insulation 4. Less A/C load, your Manual J states this house needs 2 ½ -tons

Mold is Gold? Seminar held in Tampa Seminar held in Tampa Tobacco – tapped out Tobacco – tapped out Asbestos – tapped out Asbestos – tapped out Food Food Obesity Obesity Mold Mold

What about “ultra-high” SEER To achieve very high SEER above 15, typically electronically commutated motors are employed, variable speed technology, they save energy and have speed control (rpm)

Variable Speed Variable speed indoor fans are the starting point to development of lower SHR equipment Variable speed indoor fans are the starting point to development of lower SHR equipment

Variable Speed Variable speed indoor fans are the starting point to development of lower SHR equipment Variable speed indoor fans are the starting point to development of lower SHR equipment At equilibrium (running state), if the fan speed is reduced lower coil temperatures are achieved At equilibrium (running state), if the fan speed is reduced lower coil temperatures are achieved

Variable Speed Variable speed indoor fans are the starting point to development of lower SHR equipment Variable speed indoor fans are the starting point to development of lower SHR equipment At equilibrium (running state), if the fan speed is reduced lower coil temperatures are achieved At equilibrium (running state), if the fan speed is reduced lower coil temperatures are achieved Remember water still freezes at 32F Remember water still freezes at 32F

Variable Speed Indoor Fans 2 This “new” technology has been around for quite some time, the first units from the late 1980’s This “new” technology has been around for quite some time, the first units from the late 1980’s By preventing air movement simultaneously with compressor start, delaying the ID fan, system dew point may be achieved in under 60-seconds vs. 5+ minutes, then “ramping up” airflow allows coil temps significantly lower than std. A/C By preventing air movement simultaneously with compressor start, delaying the ID fan, system dew point may be achieved in under 60-seconds vs. 5+ minutes, then “ramping up” airflow allows coil temps significantly lower than std. A/C The 6-minute cycle…when operating other than the long afternoon cycle, this technology gives 5- minutes dehumidification from every cycle vs. 1- minute. The 6-minute cycle…when operating other than the long afternoon cycle, this technology gives 5- minutes dehumidification from every cycle vs. 1- minute.

Where are we headed? Some form of variable speed technology will filter down even into “builder” type units Some form of variable speed technology will filter down even into “builder” type units To comply with increasing stringent energy codes the SEER will rise To comply with increasing stringent energy codes the SEER will rise

Where are we headed? Some form of variable speed technology will filter down even into “builder” type units Some form of variable speed technology will filter down even into “builder” type units To comply with increasing stringent energy codes the SEER will rise To comply with increasing stringent energy codes the SEER will rise To keep from “MOLDing” a building, smart A/C contractors will: To keep from “MOLDing” a building, smart A/C contractors will:

Where are we headed? Some form of variable speed technology will filter down even into “builder” type units Some form of variable speed technology will filter down even into “builder” type units To comply with increasing stringent energy codes the SEER will rise To comply with increasing stringent energy codes the SEER will rise To keep from “MOLDing” a building, smart A/C contractors will: To keep from “MOLDing” a building, smart A/C contractors will: 1.Run exact room by room loads

Where are we headed? Some form of variable speed technology will filter down even into “builder” type units Some form of variable speed technology will filter down even into “builder” type units To comply with increasing stringent energy codes the SEER will rise To comply with increasing stringent energy codes the SEER will rise To keep from “MOLDing” a building, smart A/C contractors will: To keep from “MOLDing” a building, smart A/C contractors will: 1.Run exact room by room loads 2.Be careful when sizing duct, (bigger is better)

Where are we headed? Some form of variable speed technology will filter down even into “builder” type units Some form of variable speed technology will filter down even into “builder” type units To comply with increasing stringent energy codes the SEER will rise To comply with increasing stringent energy codes the SEER will rise To keep from “MOLDing” a building, smart A/C contractors will: To keep from “MOLDing” a building, smart A/C contractors will: 1.Run exact room by room loads 2.Be careful when sizing duct, (bigger is better) 3.Size equipment “right on”, not oversized

Where are we headed? Some form of variable speed technology will filter down even into “builder” type units Some form of variable speed technology will filter down even into “builder” type units To comply with increasing stringent energy codes the SEER will rise To comply with increasing stringent energy codes the SEER will rise To keep from “MOLDing” a building, smart A/C contractors will: To keep from “MOLDing” a building, smart A/C contractors will: 1.Run exact room by room loads 2.Be careful when sizing duct, (bigger is better) 3.Size equipment right on 4.Select equipment for latent heat removal

Where are we headed? Some form of variable speed technology will filter down even into “builder” type units Some form of variable speed technology will filter down even into “builder” type units To comply with increasing stringent energy codes the SEER will rise To comply with increasing stringent energy codes the SEER will rise To keep from “MOLDing” a building, smart A/C contractors will: To keep from “MOLDing” a building, smart A/C contractors will: 1.Run exact room by room loads 2.Be careful when sizing duct, (bigger is better) 3.Size equipment right on 4.Select equipment for latent heat removal 5.SHR must match the SHR of the house load

Remember, what happens if the A/C is oversized? 1. Components are more expensive, larger 2. Ductwork is larger, more airflow, more noise 3. Increase number of starts and stops 4. Increased electric consumption 5. Shorter run time each cycle, higher rh 6. Cycling during afternoon, higher rh 7. Very short cycles in mild weather (under 85 outdoor), may be shorter than 6-minutes, never reaches dew point, higher rh 8. Nothing good!

Final Considerations Correct sizing is a MUST! Correct sizing is a MUST!

Final Considerations Correct sizing is a MUST! Correct sizing is a MUST! Old square foot/ton numbers won’t work, anyone that says, “500 sq. ft. per ton” should be SHOT!!! Old square foot/ton numbers won’t work, anyone that says, “500 sq. ft. per ton” should be SHOT!!!

Final Considerations Correct sizing is a MUST! Correct sizing is a MUST! Old square foot/ton numbers won’t work, anyone that says, “500 sq. ft. per ton” should be SHOT!!! Old square foot/ton numbers won’t work, anyone that says, “500 sq. ft. per ton” should be SHOT!!! Contractors must consider the latent heat consequences when selecting equipment - SHR Contractors must consider the latent heat consequences when selecting equipment - SHR

Final Considerations Correct sizing is a MUST! Correct sizing is a MUST! Old square foot/ton numbers won’t work, anyone that says, “500 sq. ft. per ton” should be SHOT!!! Old square foot/ton numbers won’t work, anyone that says, “500 sq. ft. per ton” should be SHOT!!! Contractors must consider the latent heat consequences when selecting equipment - SHR Contractors must consider the latent heat consequences when selecting equipment - SHR Windows are “the key” to sizing Windows are “the key” to sizing

Why did people move to Florida? Comfort Comfort Central A/C allowed them to be comfortable in a subtropical climate Central A/C allowed them to be comfortable in a subtropical climate High efficiency makes that comfort affordable...unless High efficiency makes that comfort affordable...unless We create MOLD with improper system selection (SHR), so we need to do the job right! We create MOLD with improper system selection (SHR), so we need to do the job right!

Questions?