Scott Curry & Cindy Collins Innov-X Canada

Slides:



Advertisements
Similar presentations
Elemental Analytical Probe for On-Field Depth Profiling    Rick Comtois, Judit Jeney* Austin AI Inc, Austin/Texas, USA *GreenLab Europe.
Advertisements

Environmentally sound management of ship recycling- simple or complex? Roy Watkinson Department for Environment, Food and Rural Affairs UK Promoting Sustainable.
Site Characterization Instructional Goal: Upon completion of this topic the participant will better understand the need to identify and evaluate various.
Connecticut Brownfield Sites
An innovative tool for the review of health and safety work practices and the implementation of effective controls of particulate exposures.
Presented By: Dean Soultanian Director of Proposal Development & Principal in Charge of PCB Remediation Activities March 30, 2011 Managing PCB Contaminated.
PHASE II ESA 2014 ESA GUIDELINES. PHASE II ESA 2014 ESA GUIDELINES PROJECT DEVELOPMENT PROCESSES –PATH 2 AND 3 PROJECTS –PATH 4 AND 5 PROJECTS W/ WORK.
NATO June 2007 Tour de table presentation Nadine DUESO Coordinator Contaminated sites department ADEME - FRANCE.
BoRit Superfund Site Timeline
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Office of Science U.S. Department of Energy Streamlined.
Part III Solid Waste Engineering
What is NPDES? “National Pollutant Discharge Elimination System”
EPA EMS General Awareness Training Presented by David Guest, Esq. U.S. EPA Washington, D.C.
PCB - What You Need to Know Presented by:  Darren Lee  Environmental Control Corp., Project Mgr.,  Industrial Hygienist  Previous West Linn- Wilsonville.
X Ray Flouresence Analysis (XRF). XRF X-Ray Fluorescence is used to identify and measure the concentration of elements in a sample X-Ray Fluorescence.
EnviroSense, Inc. An Overview of Environmental Factors in Developing Brownfields Sites in Massachusetts Presented By: Eric S. Wood, P.Hg., PG, LSP President.
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
Environmental Engineering
ISO Standard is based on the management model of plan – do - check – act. Today we all be discussing the elements of the standard that deal with.
Pollution Prevention for Light Industry and the Service Industry P2 Ideas for Urban Environments.
1 MEASURING THE EFFECTIVENESS OF THE NATION’S FOODSERVICE AND RETAIL FOOD PROTECTION SYSTEM.
EVOLUTION OF AIR FORCE ENVIRONMENTAL PROTECTION Thomas Russell, P.E. U.S. Air Force Center for Environmental Excellence Partnership for Peace Conference,
Huzairy Hassan School of Bioprocess Engineering UniMAP.
Environmental Management System (EMS) Awareness Training.
1 of 25 The EPA 7-Step DQO Process Step 5 - Define Decision Rules 15 minutes Presenter: Sebastian Tindall DQO Training Course Day 2 Module 14.
1 Augean plc Hazardous waste management services.
Managing Environmental Data for Conceptual Site Models Dr. David W. Rich Indianapolis, IN February 26, :45 – 3:30.
HOW TO DO Pollution Prevention & Good Housekeeping NC STATE UNIVERSITY.
Decontamination of filed equipment used in environmental site characterization and ground-water monitoring projects University of Arkansas 11/13/2006 By.
WasteSection 3 Section 3: Hazardous Waste Preview Bellringer Objectives Types of Hazardous Waste Resource Conservation and Recovery Act The Superfund Act.
Brownfields Health Risks & Remediation Diogo Cadima Topic ‘A’ Term Project CET 413.
Hong Kong. Group Members: Chan Ching Ching (6S , 18) Lau Hiu Tung (6S , 25) Content: 1.Types of waste in Hong Kong 2.Effects on environment of Hong Kong.
TURNING BROWNFIELDS. Definition US EPA 1997 abandoned, idled or under-used industrial and commercial facilities where expansion or redevelopment is complicated.
Module 1: Introduction to the Superfund Program. 2 Module Objectives q Explain the legislative history of Superfund q Describe the relationship between.
LESSON 2: CHARACTERISTICS AND QUANTITY OF MSW. Goals  Determine why quantification is important  Understand the methodology used to quantify MSW  Become.
Organization and Implementation of a National Regulatory Program for the Control of Radiation Sources Inspection Part II.
WasteSection 3 Types of Hazardous Waste Hazardous wastes are wastes that are a risk to the health of humans or other living organisms. They may be solids,
Important informations
Chapter 16 Waste Generation and Waste Disposal.  Refuse collected by municipalities from households, small businesses, and institutions such as schools,
Supplemental Study for Year 3 Project Completed. Reason for Supplemental Study  Accelerate new lines of research which were identified in August 1999.
I.Summary of technical guideline II.Reviews III.Recommendations.
Inspection Directions: An EMS Approach to Inspecting for Section 608 and 609 Compliance.
Check List Environmental Costs From Lecture #3. Prevention Costs - definition Environmental prevention costs are the costs of activities carried out to.
ME551/GEO551 Introduction to Geology of Industrial Minerals Spring 2005 SAMPLING.
6/5/2016 PEO Aircraft Carriers Aerosol Can Evacuation & Compaction Unit SBIR Topic N
Construction and Demolition Waste Management at UVM.
Area I Burn Pit Santa Susana Field Laboratory RCRA Facility Investigation Work Plan February 19, 2008 Laura Rainey, P.G. Senior Engineering Geologist California.
ISO MONITORING AND MEASUREMENT. ISO Environmental Management Systems2 Lesson Learning Goals At the end of this lesson you should be.
Sorting Technologies for CCA Treated Wood. Objective To design and implement an automated system to effectively sort CCA treated wood from other wood.
Solid & Hazardous Wastes. Domestic Waste  38 % Paper  18% Yard waste  8% Metals  8% Plastic (20% by volume)  7% Glass  7% Food  14% Miscellaneous.
IAEA International Atomic Energy Agency. IAEA Dr. Abraham Gregorio de Rosa,Sp.Rad Radiologist in HNGV Dili, Timor Leste 2 Perspectives on regulatory models.
Environment and Disaster Planning Hari Srinivas, GDRC Rajib Shaw, Kyoto University Contents of the presentation: -What is the problem? -Precautionary Principles.
Ukraine Petro Nakhaba All-Ukrainian Public Organization “ Chysta Khvylya ” Deputy Head Kyiv, Ukraine Contaminated Sites Management Joint UMOE-DEPA Project.
Bellringer. Types of Hazardous Waste Hazardous wastes are wastes that are a risk to the health of humans or other living organisms. – They include: solids,
MICHAEL E. SCOTT, DEPUTY DIRECTOR DIVISION OF WASTE MANAGEMENT Available Information on the Beneficial Reuse of Coal Combustion Products 1.
1 FORMER COS COB POWER PLANT From Characterization to Redevelopment Brownfields2006 November 14, 2006.
Environmental Site Assessments Hazardous Materials/ Regulated Substances Categorical Exclusion Training Class.
Toxic waste is generally described as many discarded material that is dangerous to any life form, including humans, animals and plant life. Toxic waste.
1 Solid and Hazardous Waste Chapter 21 Living in the Environment, 13 th Edition, Miller.
Laboratory Decommissioning : Essential Tools and Lessons Learned Jim Carscadden Division of Environmental Protection Office of Research Facilities.
Omaha Riverfront Redevelopment Project Brownfields 2004 C. Dale Jacobson, P.E., DEE.
Environmental Management Division 1 NASA Headquarters Environmental Management System (EMS) Michael J. Green, PE NASA EMS Lead NASA Headquarters Washington,
Identifying Environmental Aspects EPA Regions 9 & 10 and The Federal Network for Sustainability.
Lecture (11): Waste Recycling
Sustainable Redevelopment
Sorting Technologies for CCA Treated Wood
Resource Conservation and Recovery Act (RCRA)
Classroom Catalyst.
Managing Environmental Data for Conceptual Site Models
Main Objectives of This Secession
Presentation transcript:

Scott Curry & Cindy Collins Innov-X Canada An Introduction to Portable XRF for Exploration, Mining and Geochemistry Applications Scott Curry & Cindy Collins Innov-X Canada

Presentation Outline Fundamental XRF Concepts and Sample Data Limitations of Portable XRF Xplorer - Seamless XRF/GPS/GIS Integration Sample Applications Sampling, Project Planning and Tips for XRF Questions

What can XRF do for reclamation? Tailings Chemical disposal Soil and water contaminant analysis for mine site and perimeter monitoring Provide large inexpensive datasets continuously from environmental baseline data to clean up and monitoring Be an integral part of the mine reclamation plan Be part of the tool chest of technologies and methodologies for reclamation during and after life of mine from removal of structures (Pb paint testing & metals recycling) to analyzing tailings and waste rock disposal (hydrological and soil testing)

Fundamental Concepts

What does XRF do? Portable XRF can quickly and effectively Detect and Quantify the elements from Mg to U on the periodic table. Non destructive – can test the same sample multiple times. Fast – data can be achieved in seconds resulting in large and inexpensive data sets. Portable – get results at the actual sample location Accurate - Can develop semi-quantitative to quantitative data sets.

Sample Applications

History of XRF From the discovery of x-rays in 1895 to the quantification of x-rays in 1913 and the development of early XRF Spectrometers in the 50’s, XRF research and development continued has become what it is today Early spectrometers were WDXRD measuring wavelength for one element at a time With the need for smaller sized equipment, lower costs, and use by less skilled operators came the EDXRF in the 60’s; EDXRF measures the characteristic energy of an element Subsequent improvement in detectors and signal resolution lead to measurement of several elements in one sample Early EDXRF use radioisotopes for excitation requiring recycling of a depleted radioactive source, recalibration and replacement at significant costs Current state-of-the-art EDXRF includes x-ray tubes, solid-state components, electronics, computers and software Now this mature technology is routinely used for R&D, QC, production support and regulatory compliance

Energy Dispersive XRF

Energy Dispersive XRF

Energy Dispersive XRF

Energy Dispersive XRF

EDXRF Spectral Capture Example of export format (csv file)

Applications

General Environmental Applications Mine reclamation Environmental baseline data over large areas with large inexpensive datasets Liquid analysis Pb paint analysis Filter analysis Soil and other materials

Pb in soils Blacksmith Institute working to limit Pb poisoning plaguing remote villages in Nigeria In seconds the XRF analyzer identifies pollutant metals including Pb as low as 0.001% Remediation begins and processing procedures are altered to avoid a recurrence The EPA provides a recommended soil testing method for XRF, EPA Method 6200

Hazardous Waste Screening Debris for hazardous or non-hazardous disposal in lieu of TCLP testing (toxicity characteristic leaching) Extreme weather debris migration Construction or demolition project waste Waste streams and oil pools Industrial and mining process on community perimeters

Property Assessment Immediately identify heavy metals in soil at low ppm levels Real-time metal screening at construction or disposal sites – Pb, U, RCRA, Priority Pollutants Brownfields Phase I/II/III Lead (Pb) clearance failure avoidance Tube-based Pb Paint Analysis Airborne metals in mining, welding, construction, fabrication, maintenance and repair, paint removal and renovation

Published SOP Methods EPA 6200 HUD PCS for testing Pb in Paint XRF soil testing HUD PCS for testing Pb in Paint NIOSH Method for Pb in filters OSHA Method ID204 Quantitative X-Ray Fluorescence Analysis of Workplace Substances ID204. (Air or wipe filter & bulk material) RWM-DR-025 Metals in solid media

Peer Reviewed Tech Articles Arsenic in Hurricane Katrina Wood Debris Determination of Br in Regulated Foods Determination of Soil Calcium Using FPXRF Evaluation of New XRF Instrumentation at Hazmat and Abandoned Mine Land Site – Hazardous Materials Evaluation of Portable XRF for Gypsum Quantification in Soils Evaluation of Technologies for Sorting CCA-Treated Wood Identification and mapping of heavy metal pollution in soils Identification through XRF of Dental Restorative Resins Presence and Breakdown of BFRs in Vehicles Reclaiming Military Bases from Tungsten Takeover Triad Case Study: Former Small Arms Training Range

CCA – Identify Toxin-Treated wood products Screen recycled wood mulch, pellets & other by-products for toxic metals EPA compliance & label confirmation at wood treaters, lumberyards, retail centers Screen in-coming wood at municipal incinerators, landfills & recycling facilities Determine effectiveness of protective coatings & sealants from CCA & other toxins Test for arsenic leaching out of unlined landfills & around residential wood structures

Lead Inspection Lead Inspection :Classify definitive positive/negative results for Pb in seconds Comply with restrictions on lead exposure during building demolition & construction Use in manufacturing, homes or commercial buildings

Innov-X System Environmental Analyzers A Field-Proven, X-ray Tube-Based System: No Radioactive Isotopes! Accurate Analysis of RCRA (Resource Conservation & Recovery Act) Metals & Priority Pollutant Metals in Seconds Meets OSHA Methods OSA1 & OSS1 and EPA Method 6200 and NIOSH Method 7702! In-situ Tests: Rapid, thorough site investigations, delineation and contamination patterns Confirm the minimally required samples to drive investigation Avoid confirmatory lab testing of high-concentration samples Establish area contamination boundaries and depth profiles Dock into convenient testing stand for bagged or liquid samples Test directly thorough corings for depth profiles

Sampling, Project Planning and Tips

XRF Sampling and Planning Clearly establish project & sampling objectives Determine the level of data quality required by XRF: field screening or lab quality? Is it FIT FOR PURPOSE? Establish an appropriate procedure (test times, number of tests etc.) Correct & Appropriated Use of Calculation Modes (CN & FP) Always keep good records of Field Work Incorporate QA/QC Protocols: Test relevant Matrix Matched Standards, Blanks & Field Duplicates Dispatch a proportion of samples for confirmatory analysis: min 5% up to 20% for checking calibrations 25

XRF Sampling – Tips in the field Decide on sample spacing/density prior to heading into field – Regular Grid? Staggered Grid? How does my grid fit the existing geology, background and the project? Grid Systems & Projections– Lat/Long WGS84? Or Local Grid? Be Prepared: Do not forget Standardization Materials Pack extra batteries & Windows (Kapton or PP?) + Screwdriver to remove Window Assembly Include a soft lens cloth for cleaning the Window – always good to check the window after every analysis to remove contamination & inspect for damage/holes Carry necessary standards / blanks 26

Which Horizon? The surficial geology (regolith) is extremely variable dependant on environment, underlying rock type and contamination sources (mining, farming, manufacturing) Important to ensure consistent approach to sampling horizons – sample the same horizon(s) at each location Common to sample several horizons at one sample location ie. Soil A, Soil B, Saprolite, Bedrock or Cap-rocks…etc. Documentation is Integral! – Store these observations with Chemistry to enable later correlation. Make sure you are comparing apples with apples when analyzing data!

Sampling Considerations Remember, typical sample size is around 1cm2 – Collimated X-RAY Beam usually <3mm in Width Depth of Penetration is generally limited to the surface of most samples – up to 2-5mm in very light Matrix samples Need to get the detector as close to samples as possible – Built In safety Feature for “Air Shots” (based on lack of count rates received back) Use Matrix specific calibrations for specific sites and known areas of matrix variation 28

Sample Preparation 5 mm Mg Andesite (In Situ) Preparing your sample can significantly enhance the result quality: Crushing /milling / pulverizing of the sample for smaller particle sizes, sample uniformity & increased homogeneity Take advantage of new portable & mobile field preparation devices – such as Rocklabs / Essa portable Crushers & Mills Potential to setup Miniaturized / Containerized sample prep facilities in the Field to support XRF Sampling programmes For less homogenous samples – multiple readings & averaging can be effective Dry the sample to take away moisture effects Soil Sample Sieved to 250 micron 5 mm 29

Sample Method In-situ analysis with FPXRF Collect 50g of sample Split sample into two equal portions of at least 25g each Re-analyze sample in the field using FPXRF Store sample for laboratory analysis (XRF, ICP-MS) Wash through a sieve to isolate the silt and clay sized fractions Re-analyze using the FPXRF in the field Store for laboratory analysis (XRD, ICP-MS)

Addressing Issues Problem Samples do exist – ie: Oxidized surfaces, very light matrices, very dense matrices…etc. Variations due to Sample Type & Homogeneity – ie: Fine Dust vs Chips vs Core vs in-situ Rock. Vertical Segregation / Stratification of sample into bags & speared samples splits. Other effects do exist and can be corrected for if known, such as moisture & attenuation through plastic/calico bags…etc. Ensure the instrument has the correct elements configured (are they turned on?) and correctly calibrated. DO NOT simply attempt to turn an element on!

Key Points to Remember Factors can adjust for matrix effects - Use LAB data to verify chemistry and correct via the User Factor set Can also use Matrix Matched certified standards to correct factors if the matrix is consistent Chemistry results are only from what the X Rays see. Beware of homogeneity and surface effects. Longer Tests = better precision within limits 32

Adding Value to XRF Data How can I add value to my XRF Data? XRF Sampling is NO Different to any other sampling regime you adopt!... Remember the Data is very valuable (& costly)! So, Use good QA/QC Protocols & Data Validation Incorporate Standards, Blanks, Field Duplicates and Check Samples to increase your understanding & confidence Rank & Store the Data in a well ordered & structured DB

Innov-X - Choosing an Analyzer

Innov-X Systems Existing Products

Introducing the handheld David Pawliuk, Vice President, Exploration, SILVER QUEST RESOURCES LTD., Vancouver, BC “We acquired an Innov-X Omega XRF unit early in the 2010 field season. The unit went to Yukon, where it was used to test soils in the Dawson Range for the pathfinder elements (As, Sb) associated with gold mineralization. By using the Omega our crew could immediately identify and follow-up on mineralized trends exposed in our backhoe trenches. The trenching was more efficient and focused than it otherwise would have been, saving precious time and thousands of dollars. The Omega may have paid for itself already.” Introducing the handheld

New Delta Handheld XRF Launched globally Feb 1, 2010 as superior XRF platform to Alpha and Omega systems. 4Watt System = most powerful Hand Held XRF on the market. Large Area SDD = highest count rate and lowest signal to noise ratio on the market. Light element measurement capability in air (Mg, Al, Si). Design Brief Smaller / Faster / Cooler / Tougher Upgradeable Tube anode optimization (Ag, Au, Ta, Rh) Capable of incorporating a camera and collimator for targeting smaller (<1cm2) analysis areas on samples (grain size issues) Leap frogs existing technology in as many ways as possible Add innovations as appropriate and make expandable and adaptable.

Delta Handheld XRF Product Models Premium Vacuum (for low level Mg) Large Area SDD and vacuum. Premium Large Area SDD detector Standard Typical SDD Detector Classic PIN diode detector Range of tube anode materials available SDD = New Silicon Drift Detector Technology PIN = Older Silicon PIN Detector – as used in Alpha

Portable Test Stand for Handhelds Portable Test Stand for the Omega and Delta Allows use of the Handheld like a bench top to obtain maximum flexibility, in field or fixed in camp or lab Can be operated from laptop computer Lid Closed Lid Open

Introducing the original portable bench top X5000 Dr. Trevor MacHattie, Mineral Deposits Geologist, NOVA SCOTIA DEPT. of NATURAL RESOURCES “The X-5000 produces rapid, amazingly accurate, and precise geochemical data for us. We’ve recently discovered new rare earth element mineralization with the aid of the X-5000 and it has now become an essential tool in our field work and mineral deposit research, every geologist should have one!” Introducing the original portable bench top X5000

New X-5000 Portable Bench Top 10 Watt System = most powerful portable XRF on the market. SDD detector = Lowest LOD’s achievable. Light element measurement capability in air (Mg, Al, Si). Better lower limits of detection than Hand Held for some elements (Au, Sb, Sn, Cd, Rare Earths) Range of tube anode materials available for optimization for application. Ideal for basing in an exploration camp, sample prep facility or lab where samples are collected and brought back to a central location for sample preparation and analysis. Ideal as a back-up system to lab based equipment and online/on-stream systems. No operator licence required in Canada. Completely portable with battery pack.

New X-5000 for Oils, Fuels & Liquids Transportation Power Generation Petrochemical Aerospace Mining Element X-50 (ppm) Wear Metals Titanium Chromium Iron Nickel Copper Lead 10 3 1 Fuels, Additives Analysis Sulfur Calcium Vanadium Zn Molybdenum Barium 500 30 5 20 Other Applications Hg, in aqueous solns P, in aqueous solns Cl, in process fluids 1000 200 Rapid on-the-spot elemental analysis for oils, fuels and other liquids Unique fluid handling system Uses 50 KeV tube, 10 Watt power rating

Flexibility in application Easily test liquids, soil bags, metals and core.

Delta Xplorer System Seamless XRF/GPS/GIS/ Geochemical Analysis Integration Ross Sherlock Exploration Manager, Gold Fields Canada, “We have used the Omega XRF fairly extensively in our Canadian exploration efforts and are pleased with the results. In the right environment the tool provides fast and reliable geochemical information reducing lab costs and turn-around time.”

The Essential Mobile GIS Solution for Real-Time FPXRF Delta Xplorer System A Total Field Data Collection Solution Consisting Of: Ruggedized Innov-X Systems Delta Portable XRF Analyzer Ruggedized TRIMBLE NOMAD or YUMA Field Computer with built in GPS +/- Optional High Accuracy DGPS ESRI ArcPAD or ENCOM Discover Mobile – Field Mobile GIS Integration Package Mobile GIS extension software – Bluetooth communication software between Delta XRF, Trimble GPS and GIS software. The Essential Mobile GIS Solution for Real-Time FPXRF

Delta Xplorer Overview

In-field example: Tritton Cu NSW Nominal 50m x 50m Sample Grid Designed Actual Sample Location Taken By DGPS Sample Chemistry Registered Real-Time

Xplorer Workflow Xplorer - Simplified Workflow: Innov-X Delta & TRIMBLE Nomad are Bluetooth paired for Communications Mobile GIS started on Trimble Nomad Soil Readings taken outside in open air & Result Received on Nomad GPS Position Confirmed on finalization of result Data is exported from Trimble Nomad to Mapinfo or ArcPad to ioGAS Data presented graphically in Parent GIS

Delta Xplorer - Output

Delta Xplorer - Output Google Earth Export From ioGAS WGS84 Locations Full Chemistry from FPXRF Google Earth Export From ioGAS

Thank you 1201 W. Georgia St, Suite 2 Vancouver , BC V6E 3J5 CAN ANCHORAGE VANCOUVER 1201 W. Georgia St, Suite 2 Vancouver , BC V6E 3J5 CAN T. +1 778 960 6279 F. +1 888 873 6598 W. www.innovx.ca Thank you