MIPAS Quality assessment of ENVISAT Atmospheric mission: implication for the scientific user community The monthly reports for each instrument.

Slides:



Advertisements
Similar presentations
Simon Pinnock ESA Technical Officer
Advertisements

Data processing and quality control activities in support to the GOMOS mission F. Niro (1), D. Del Cavallo (1), G. Barrot (2), T. Fehr (3) (1) Serco SpA,
Data processing and quality control activities in support to the MIPAS mission F. Niro (1), T. Fehr (2) (1) Serco SpA, ; (2) ESA/ESRIN,
EGU 2009 Vienna 19 – 24 Apr 2009 Ice on IR sensors: MIPAS case Ice contamination on satellite IR sensors: the MIPAS case F. Niro (1), T. Fehr (2), A. Kleinert.
RA-2 & MWR CCVT – ESA/ESRIN – 25 to 27 March, 2003 MWR Calibration & Validation status MWR Cal/Val team: Ngan Tran, Estelle Obligis, Laurence Eymard, Michel.
July 2006Instrument Scientist Retreat, Santiago Quality Control: closing the loop Reinhard Hanuschik, DFO/QC 1. Principles 2. Processes 3. Critical components.
UPDATE ON BIAS TRENDS, DIRECT SUN CORRECTION, AND ROUGHNESS CORRECTION Joe Tenerelli May 10, 2011.
REVIEW OF OBSERVED BIAS TRENDS OVER THE OCEAN AND POTENTIAL IMPACT OF PROCESSOR EVOLUTION Joe & Nicolas IFREMER/CLS ESL Quality Working Group #5 May 30-31,
GOME-2 polarisation data and products L.G. Tilstra (1,2), I. Aben (1), P. Stammes (2) (1) SRON; (2) KNMI GSAG #42, EUMETSAT,
Time & Frequency Products R. Peřestý, J. Kraus, SWRM 4 th Data Quality Workshop 2-5 December 2014 GFZ Potsdam Recent results on ACC Data Processing 1 SWARM.
Rosetta Magnetic Field PDS Review B. J. Anderson.
SABER Instrument Performance and Measurement Requirements.
Page 1 SCIAMACHY Pointing Meeting Bremen – 30 November 2006 MIPAS Pointing Error Status Gaétan Perron ABB Bomem Inc.
DOSTAG Meeting #51, 3 rd May 2007 Access to ESA Earth Observation data (past and current missions)
SCILOV-10 Validation of SCIAMACHY limb operational BrO product F. Azam, K. Weigel, A. Rozanov, M. Weber, H. Bovensmann and J. P. Burrows ESA/ESRIN, Frascati,
1.STSE 2.Objectives of today 3.Data availability 4.Reprocessing 5.RFI 6.Conferences & user meetings Introduction – SMOS mission status.
Full Resolution – Reduced Resolution differences E. Papandrea, M. Carlotti, M. Ridolfi, E. Arnone DCFI, University of Bologna, Italy B.M. Dinelli ISAC-CNR,
Forschungszentrum Karlsruhe in der Helmholtz-Gemeinschaft NDACC H2O workshop, Bern, July 2006 Water vapour profiles by ground-based FTIR Spectroscopy:
Microwindow Selection for the MIPAS Reduced Resolution Mode INTRODUCTION Microwindows are the small subsets of the complete MIPAS spectrum which are used.
Analysis of L1b files with restituted attitude Bianca M. Dinelli E. Papandrea.
Chiara Piccolo and Anu Dudhia Atmospheric, Oceanic and Planetary Physics, Department of Physics, Oxford University, Oxford, UK Predicted.
Page 1 Reduced Resolution Retrievals from MIPAS / MORSE and Oxford Level 2 Monitoring Alastair Burgess and Anu Dudhia Atmospheric, Oceanic and Planetary.
Atmospheric, Oceanic & Planetary Physics, University of Oxford A Dudhia MIPAS QWG16 Venice Apr 2008 Page 1 Recent MIPAS L2 Data Retrieved at Oxford.
Cloud Top Height Retrieval From MIPAS Jane Hurley, Anu Dudhia, Graham Ewen, Don Grainger Atmospheric, Oceanic and Planetary Physics, University of Oxford.
Aerosol Climate Change Initiative Stratospheric activities around the Aerosol_CCI project C. Bingen, C. Robert, A. Bourrassa & Aerosol_CCI Team F. Vanhellemont,
WP 3: Absorbing Aerosol Index (AAI) WP 10: Level-1 validation L.G. Tilstra 1, I. Aben 2, and P. Stammes 1 1 Royal Netherlands Meteorological Institute.
Earth Observation, Navigation & Science Page 1 Capacity Final Presentation, , Estec, Noordwijk Report for WP 3300 WP 3300.
FP OntoGrid: Paving the way for Knowledgeable Grid Services and Systems WP8: Use case 1: Quality Analysis for Satellite Missions.
Use of GPS RO in Operations at NCEP
© Grant Thornton | | | | | Guidance on Monitoring Internal Control Systems COSO Monitoring Project Update FEI - CFIT Meeting September 25, 2008.
Van Allen Probes Spacecraft Operations July 29, 2015 Kristin Fretz
CAPACITY Operational Atmospheric Chemistry Monitoring Missions CAPACITY Final Meeting - WP Ground Segment synthesis Final Meeting ESTEC02/06/05.
EUMETSAT, July 2013 Coordination Group for Meteorological Satellites - CGMS Satellite Event Working Group by EUMETSAT Presented to CGMS-41, WGII/3.
Atmospheric Science Conference, ESA-ESRIN, 2006 Spatial and temporal distributions of water vapour in the UTLS as observed with MIPAS/Envisat M.Milz for.
Page 1 Validation by Model Assimilation and/or Satellite Intercomparison - ESRIN 9–13 December 2002 Monitoring of near-real-time SCIAMACHY, MIPAS, and.
® Kick off meeting. February 17th, 2011 QUAlity aware VIsualisation for the Global Earth Observation system of systems GEOVIQUA workshop February, the.
Validation workshop, Frascati, 13 December 2002Page 1 SCIAMACHY products quality and recommendations Based on presentations and discussions during this.
Page 1ENVISAT Validation Review / GOMOS session - ESRIN – 13th December 2002 ENVISAT VALIDATION WORKSHOP GOMOS Recommendations by the ESL team : Service.
SCIAMACHY long-term validation M. Weber, S. Mieruch, A. Rozanov, C. von Savigny, W. Chehade, R. Bauer, and H. Bovensmann Institut für Umweltphysik, Universität.
SMOS QWG-6, ESRIN October 2011 OTT generation strategy and associated issues 1 The SMOS L2 OS Team.
Swift HUG April Swift data archive Lorella Angelini HEASARC.
GIST th -16 th Dec B.Stewart RAL Mirror Anomaly Review Board Update.
Statistical Process Control04/03/961 What is Variation? Less Variation = Higher Quality.
Herschel Open Time Cycle 1 DP workshop ESAC, March page 1 Tour of HIFI data.
Issues concerning the interpretation of statistical significance tests.
March 2004 At A Glance autoProducts is an automated flight dynamics product generation system. It provides a mission flight operations team with the capability.
AIRS Radiance and Geophysical Products: Methodology and Validation Mitch Goldberg, Larry McMillin NOAA/NESDIS Walter Wolf, Lihang Zhou, Yanni Qu and M.
INSTRUMENT STATUS AND PERFORMANCE Guido Levrini. Page 2 ENVISAT Validation Workshop - ESRIN - 9–13 December 2002 ASAR F Instrument operability issues.
All rights reserved © Altec ExoMars 2018 Rover Operations Control Centre Science instruments data pipeline G. Martucci.
Implementation and Processing outline Processing Framework of VIIRS instrument monitoring System Processing Framework of VIIRS EV data Monitoring SD/SDSM.
GIST-24 Meeting December MSG PROGRAMME STATUS Presentation to the GIST-24 meeting.
Analysis of Nonlinearity Correction for CrIS SDR April 25, 2012 Chunming Wang NGAS Comparisons Between V32 and V33 Engineering Packets.
Sciavalig – 6-8/12/2004 Status of the Atmospheric Chemistry Instruments onboard Envisat SCIAVALIG 6–8 December 2004 Rob Koopman Angelika Dehn Lidia Saavedra.
PACS NHSC Data Processing Workshop Aug 26-30, 2013 Page 1 SPIRE Spectrometer Data: Calibration Updates, User Data Reprocessing, and Other Issues Nanyao.
1 st post launch SCIAMACHY calibration & Verification Meeting L1b Astrium Friedrichshafen – Germany 24 July 2002 First level 1b Leakage current analysis.
Nine Years of Atmospheric Remote Sensing with SCIAMACHY – Instrument Performance Gottwald, Krieg, Lichtenberg, Slijkhuis – DLR-IMF Noël, Bramstedt, Bovensmann,
Agency xxx, version xx, Date xx 2016 [update in the slide master] Coordination Group for Meteorological Satellites - CGMS Introduction to GSICS Presented.
EUM/OPS/VWG/11/3248 Issue 1 04/09/2011 Eumetsat Conference, 3-7 September 2012, Sopot, Poland Satellite Event Working Group GSICS Workshop, 4 September.
ESA Climate Change Initiative Sea-level-CCI project A.Cazenave (Science Leader), G.Larnicol /Y.Faugere(Project Leader), M.Ablain (EO) MARCDAT-III meeting.
GOMOS Mission and Processing Status On 22nd March 2003 GOMOS suffered the anomaly ‘Azimuth Voice coil command saturation”. The anomaly occurred during.
Calibration Events Working Group GSICS TeleConference 23 October 2012
Dehn(1), F. Niro(1), A. von Bargen(2), T. Fehr(3)
MIPAS Monitoring at Oxford
Status of ACVE-3/pre-validation recommendationss 21. 6
GLAST Large Area Telescope:
Proposal for LAT Year 1 Data Release Plan
Manik Bali Jonathan Mittaz
Dorothee Coppens.
MIPAS-2D water database and its validation
How good is IASI-A as an in-orbit reference in GSICS in LWIR and IR
Presentation transcript:

MIPAS Quality assessment of ENVISAT Atmospheric mission: implication for the scientific user community The monthly reports for each instrument are publicly available on the web at the pcs web page (see screen shot on the right): MIPAS GOMOS SCIAMACHY Mission and Processing Status The NRT mission was suspended on March 2004 in order to update the algorithms to the new measurement scenario. OFL processing of the RR mission has started on Feb 2006 with the current IPF 4.65 and the data are available via ftp on D-PAC server. The Aug-Sept 2004 data were processed up to L2, the other RR data were processed up to L1b. Besides the daily monitoring the evolution of key parameters is important for assessment of instrument performances and for mission evolution and calibration plan definition. Examples are shown here below. Further details can be found in the MIPAS monthly report available on the web: Gain long term trend The gain accumulation rate is reported in Fig. 6. The points are the maxima of relative variation of gain in band A, the calculation is weekly updated. This plot shows the evident effect of ice contamination during Jan-May 2005 resolved with the decontamination of June  A gain recalibration was needed in order to ensure good data quality.  NESR is increasing due to this ice contamination  It is also evident the passive decontamination effect of last ENVISAT anomaly of 6 Apr Performance assessment LOS long term trend In Fig. 7 is reported the MIPAS mispointing since start of mission updated to the end of April The relative error is the one to be considered, since it takes into account the commanded bias. In this plot it is evident the correction of the seasonal trend after the upgrade of the on-board s/w on Dec The trend in the last months seems stable with a relative bias of few mdeg. Instrument and Products monitoring L2 non-nominal number of succesfull retrieval. The L2 plot of Fig. 4 shows the retrieval summary results for one day of RR measurement (21 Aug 2004). A problem in the retrieval of p-T for some orbit (note that in the plot 7 should be the nominal value corresponding to nominal # of retrieved ESA products). After the investigation it was found that the problem is due to corruption in L1 spectra, in the band D, while the other bands are good. A processor change will be suggested in order not to flag as corrupted one sweep if only one band is corrupted. At a first stage the products monitoring consists in the daily check of the products availability and format in relation to mission planning. The QUADAS daily monitoring/reporting tool nowadays is implemented for the following MIPAS products: L0 NRT (checking instrument health) L1 and L2 OFL (checking data processing quality) L0 daily NRT report are available on the web: Instrument unavailability Products disclaimer General request Source of information The L0 monitoring consists in the check of important telemetry data which give information about instrument temperatures (IDU, MIO, INT, CBB), slide performances and cooler vibrations. Each time a significant parameter exceed the warning level an alert is sent to FOS and the anomaly is investigated with the support of industry (Astrium). Two example of non-nominal behavior are given below for two critical instrument parameter: CBB temparature and cooler vibrations. In Fig. 1 the Cooler vibration recorded during 6 Jan 2006 shows strange spikes due to variations of platform illumination condition. In Fig. 2 the daily plot of CBB temperature shows excessive value after the ENVISAT PLSOL anomaly of 6 April Concerning L1 monitoring significant indicators are the PCD quality flag, the number of spikes and corrupted sweeps, the number of FCE, the NESR level and the ADF usage. In particular a wrong ADF usage, especially for the gain calibration could lead to bad quality of the spectra and systematic error in the products retrieval, see example below. L1 ADF usage anomaly. The D-PAC center didn’t receive correct ADF (due to PDS problem) and the L1 products were generated with outdated ADF from 8 to 22 Feb As a result the critical gain calibration of the spectra was strongly affected by this anomaly. See in Fig. 3 the plots of NESR level during 21 Feb 2006, where the red level shows excessive noise. In the band A.  The scientific community was alerted not to use these products, the products were deleted and reprocessed with correct ADF. The monitoring of L2 data is particularly complex and many indicators are taken into account; the most important parameters are the time trend plot of retrieved parameters, the LOS pointing Vs retrieved altitudes, the MW offset and the chisquare values. The detection of one L2 anomaly need a long investigation since many source of error can be responsible for non-nominal behaviour (IPF, ADF, L1, L0,...). An example of L2 anomaly is given below. Quality check of scientific data During Feb 2006 the interferometer suffers from increased anomaly rate, a quality assessment on the scientific data was carried out in order to see if the slide anomaly affects the quality of the L1b spectra.  No evidence of quality degradation was found; indeed the PCD flags of the MIPAS 4 bands is plotted in Fig. 8 showing good data quality (the green means no corrutpion).  The anomaly highlighted in Fig. 8 (see black points) at the same geo-location is due to IPF implementation error: IPF write wrong DSR in the L2 products. Temperature and Cooler monitoring. In Fig. 5 is reported monthly trend of important instrument parameter during Jan In particular on the upper part the IDU and MIO temperature, in the lower part the cooler displacer and compressor vibration, these latter parameters are closely monitored during the mission, since any cooler anomaly could dramatically affect instrument health. Fig. 5 shows that during Jan 2006 the temperature levels were stable, while the cooler vibrations show strange spikes which exceed the warning level of 8 mg. The cause is probably the inclination of the platform during this part of the year. The situation came back to nominal by the end of the month. MIPAS is a high resolution FTS which measures IR atmospheric emission in limb geometry. The original mission was suspended on March 2004 due to increase of interferometer speed anomaly. The speed anomaly is still occurring, the investigation is ongoing, so far we learned that: Turn-around failures are linked to INT temperature Bearing are degrading Mission interruption and low duty cycle are favorable for the instrument The “new” RR mission started routinely on January 2005 and is still going on. The measurement scenario was drastically changed. In particular for instrument safety the following options were adopted: Spectral Resolution reduced to 41% of original one Discontinuous measurement (around 30% duty cycle) Besides two options were adopted for science purpose: Over-sampling of the vertical domain: limb spacing is lower than FOV Floating (latitude dependent) tangent altitude to investigate tropopause MIPAS “new” mission scenario Level 0 Level 1 Level 2 Fig. 1 – Cooler vibration during 6 Jan 2006 Fig. 2 – CBB temperature after the recovery due to PLSOL anomaly. Fig. 3 – NESR plot during 21 Feb 2006: each square corresponds to a scan. Fig. 4 – Number of successful retrieval for the 21° Aug 2004 RR data. Fig. 6 – Gain long term accumulation rate from Jan 2005 up to Apr Fig. 5 – IDU, MIO temperature and Displacer, Compressor vibration for Jan Fig. 7 – MIPAS pointing error since start of mission. Fig. 8 – PCD quality flag in MIPAS band A, AB, B and C during Feb Monitoring activities in support to ENVISAT The quality assessment activities of ESA Earth Observation missions (ERS, ENVISAT, GOCE in the future ) are today performed by the DPQC organization, a Serco-Datamat consortium of specialized companies which provides a service to ESA. The DPQC atmospheric team, which involves expertise from Serco, ACRI and DLR, is responsible for the monitoring of the three ENVISAT atmospheric mission (GOMOS, MIPAS and SCIAMACHY). The satellite instruments are subject to performance degradation due to the aging of mechanical and electronics components or to the impact of platform and on-ground anomaly. Besides, the operational processor, which generates the products, is a compromise between extraction of optimal information from the measurement and the constraints of processing and dissemination resources. As a result the quality of the products arriving to the scientific user community can be variable due to several anomalies. The quick detection of instrument or products anomaly is then crucial for instrument safety and for optimization of data quality. In this poster we will address this problem considering the ENVISAT MIPAS instrument. The quality control baseline will be outlined and some examples of significant daily and long term monitoring will be reported; furthermore the implications of this activity for the scientific users will be underlined. Introduction Abstract The objective of this poster is to highlight the importance of the instrument and products monitoring and to show the implication of this task for the scientific user community. We focus our attention on the MIPAS instrument on-board the ENVISAT ESA platform and we present some example of quality monitoring results which have significant impact on science data quality. The DPQC group is furthermore responsible for many other activities related to the operational mission support. The DPQC tasks for the ENVISAT mission support can be summarized in the following: Daily and long term monitoring of instrument health Daily and long term monitoring of products Anomaly investigation and performance assessment Calibration activities and delivery of auxiliary data files Maintenance and support for IPF evolution and implementation Mission support, reporting and attendance to progress meetings Answer to general request from users