Non-Electrical Workers

Slides:



Advertisements
Similar presentations
Subcontractor Electrical Safety & NFPA 70E
Advertisements

Electrical Safety 1926 Subpart K ‑ Electrical
Introducing Electricity and Electrical Safety
Electrical Safety Program. How Electricity Works Operating an electric switch is like turning on a water faucet. Behind the faucet or switch there must.
OSHA Office of Training and Education - Revised by TEEX 12/05/07
Murray State University
Electrical Safety.
Electrical Safety Electrical Safety In and Around the Home NUECES COUNTY Risk Management Department.
Safety and Health Programs MODULE 7. 2©2006 TEEX Brainstorm  What makes a good safety and health program?  What does a good program do for you?
Hazard Recognition and Risk Analysis
Electrical Safety Basic Electrical Safety Rafael Coll, Environment Safety and Health Section Health& Safety Group Ext Pager: (630)
Electrical Safety 29 CFR I. Background for the Trainer:
CHEM 521 Safety Presentation. Hazard Symbols You Must Know.
1 Hazardous Energy Module 5. 2Objectives After this module you should be able to – identify the most common energy hazards – take the necessary steps.
General Electrical Safety. Why is it so important to work safely with or near electricity? The electrical current in regular businesses and homes has.
By: Aseem Aggarwal. Causes of Electrocution Fatalities Contact with Overhead Power lines Contact with Live Circuits Poorly Maintained Extension Cords.
Young Worker Safety Resource Center, adapted from OSHA Office of Training and Education Electrical Safety.
Electrical Safety and Grounding Essentials Copyright © Texas Education Agency, All rights reserved.
Better Safe Than Sorry A WORLD THAT STARTS WITH ELECTRICAL HAZARDS AND SAFETY. ELECTRICITY IS A VERY SERIOUS BUSINESS AND THE EFFECTS ON THE HUMAN, ELECTRICAL.
Proper Use of Extension Cords Proper Use and Electrical Hazard Awareness for Extension Cord Users Module 2.
ELECTRICAL SAFETY Safety Training for the Non-Qualified.
Electrical Safety Training
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
LABORATORY ELECTRICAL SAFETY Discussion topics: Electrical shock hazards Identifying hazards Research apparatus/ systems Proper emergency procedures Electricalfor.
Electrical Safety 29 CFR Concerned About Electricity? How many sets of Christmas lights do you plug into one extension cord? Do you still use.
Electrical Safety This material was produced under a grant (SH22249SH1) from the Occupational Safety and Health Administration, U.S. Department of Labor.
Electrical Safety - Construction. Electricity - The Dangers About 5 workers are electrocuted every week Causes 12% of young worker workplace deaths Takes.
NFPA ELECTRIC VEHICLE SAFETY FOR EMERGENCY RESPONDERS Module II : Basic Electrical Concepts And Hazards Module II : Basic Electrical Concepts And Hazards.
BUILDING TRADE SAFETY ELECTRICAL SAFETY.
Electrical Safety Safety Training Series
Safety Training For The Non-Qualified
ELECTRICAL SAFETY OSHA 29 CFR 1910 SUBPART S
© Business & Legal Reports, Inc Alabama Retail is committed to partnering with our members to create and keep safe workplaces. Be sure to check out.
Electrical Safety.
Electrical Safety INSTRUCTOR’S NOTES:
Copyright  Business & Legal Reports, Inc. Electrical Safety 29 CFR BLR’s Safety Training Presentations.
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety INSTRUCTOR’S NOTES:
Electrical Safety.
Basic Electrical Safety
Copyright  Progressive Business Publications Electrical Safety.
1a.  Exposed part  Live or energized part  De-energized part 1a.
Electricity.
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
SAFETYSAFETY. Overview ●Introduction to Safety ●Potential Electronic Mishaps ●Safe Work Practices.
Proper Use of Extension Cords
Michael Dziak Walden University Electrical Safety 2101.
Electrical Safety and Electrical Safe Work Practices EHS Course #525 Reference EHS Electrical Safety Procedure
Electrical hazard Awareness. What does hazard mean? Hazard means: any potential or actual threat to the wellbeing of people, machinery or environment.
Electrical Safety, Subpart K
1 AS OF:141330DEC15 UNCLASSIFIED OPR: 8A 8A Safety Electrical Safety Awareness Training Note: This training meets the General Electrical Safety Awareness.
 A medium that provides a means for transferring energy from one place to another  It is not expensive or difficult to control the risk of an electrical.
1 Electricity. This material was produced under grant number SH F-54 from the Occupational Safety and Health Administration, U.S. Department.
Basic Electrical Safety
Chicago Area Facilities (CAF) Electrical Safety Program.
ELECTRICAL SAFETY. OSHA Office of Training & Education Electrical Safety.
Electrical Safety Basic Electrical Safety. Electrical Safety  Course not designed to teach you to work on electrical equipment. Basic Electrical Safety.
Electrical Safety and Safe Work Practices
“Success in Safety”.
Basic Electrical Safety
Personal Protective Equipment
Electrical Safety Review Compliance Assistance Region IV
Electrical Safety.
Murray State University
Basic Electrical Safety
Click anywhere to get started…
Basic Electrical Safety
Learn from the past and prepare for a better future
Electrical Hazards By Kory Hildebrand.
Presentation transcript:

Non-Electrical Workers Electrical Safety for Non-Electrical Workers

Module 1: Electrical Fundamentals Objective Define electricity Identify mechanisms for distributing electricity (how it travels) Identify required actions to take following an electric shock.

What is Electricity? Electricity is a source of energy to power devices (e.g., lights, electrical drill, or a computer) If you compare electricity to water, voltage is the water pressure and current is the rate of flow Just as with water, the higher the voltage (pressure) or greater the current (flow rate), the more dangerous electricity becomes

Two Basic Types of Electrical Energy Alternating Current (AC) Power sources are generally supplied by generators found at hydroelectric, coal fired, or nuclear power plants AC energy is distributed by above or underground power lines for end use in home, commercial, and industrial applications Direct Current (DC) Power sources are generally supplied by batteries Batteries in cell phones, lap tops, flashlights, Uninterruptable Power Supplies (UPS) or vehicles are sources of direct current (DC)

How does electricity travel? Consider a light switch circuit: There is a source, typically 120 volts alternating current (VAC) There is a switch controlling the source, a light bulb, and a return (typically at zero volts) or ground

How does electricity travel? In the light switch, current will only flow through the circuit if the switch is closed, creating a place for the energy to go This is created by a difference in voltage between the source (120 VAC) and the return (0 Volts) If there isn’t a complete path in the circuit, current will not flow Once the switch is closed current flows and the lamp produces energy in the form of light

Electrical Shock Electric shock occurs when the human body becomes a conductor, completing the path for current to flow Basic electrical safety is that if a path is not complete, current will not flow, and shock will not occur Like water, electricity will take the path of least resistance. Current will most likely flow through a circuit instead of a human body unless the body presents a path of lower resistance.

Electrical Shock Open circuit with worker grounded Worker receiving electrical shock from lighting circuit

Effects of Shock Effects of electrical shock range from mild tingling to heart failure, depending on the amount of current Current as low as 50 milliamps can cause heart fibrillation Heart fibrillation is where the ability of the heart to pump in a regular rhythm is disrupted Given enough time in this state, it is usually fatal

Effects of Shock Severity of a shock is determined by amount of current and the path through the body If the current path is through the heart, there is a much greater chance of death than if the current passes from one finger to another At lower currents, respiratory paralysis can occur, also potentially fatal

Effects of Shock Direct effects include pain, paralysis, heart fibrillation, or tissue burn Indirect effects include confusion, amnesia, headaches, or breathing and heart irregularities Problems may last several days and progress into vision abnormalities and swelling of affected areas Over a victim’s lifetime, long range effects may include paralysis, speech/writing impairment, loss of taste, and other disorders

What To Do When A Person Is Shocked If victim is still engaged with or attached to the circuit: De-energize the circuit, if possible Remove victim from the circuit using non-conductive material (i.e., length of dry rope, dry broomstick, or leather belt) Call 911 (cells phones at SNL call 844-0911) for help immediately Apply artificial respiration and CPR, if necessary If victim is conscious, they still need medical treatment as soon as possible.

Electrical Shocks at Sandia National Laboratories Report all electric shocks to the FMOC Project Manager, Construction Observer, SDR or other appropriate SNL person to ensure that equipment is in a safe condition and an investigation can be completed, corrective actions performed, and lessons learned can be shared to help prevent a recurrence of the incident.

Arc Flash/Blast Arc Flash/Blast occurs when an energized source comes in contact with a grounded source creating an unexpected release of energy in the form of noise and pressure. Effects of Arc Flash/Blast - may cause severe burns, eye and hearing damage

Module 1 - Review Questions What is the correct sequence of events to follow if you observe someone receive a serious electrical shock? Call 911, de-energize the circuit, go home Call 911, give first aid as needed Call 911, de-energize the circuit, remove victim, take victim for medical treatment, report the incident Electric Arc Flash/Blast occurs when: An electrical system is over-loaded An energized source comes in contact with a grounded source When an person’s hand comes in contact with exposed energized conductors

Module 1 - Review Questions If you discover an unconscious person, clearly a victim of electric shock, and are unable to de-energize the electrical circuit, how do you remove the victim from the circuit? Grab the person, pull them off the energized line, render CPR. Do nothing. There's nothing you can do to help him. Wait for EMS to arrive because they are trained to deal with this kind of problem. Use non-conductive broom handle or belt to move him off the energized line, render CPR.

Module 2: Engineering Controls Objective: Identify the purpose of various engineering controls designed for electrical safety The preferred method to control electrical hazards is to engineer controls into the design of equipment

Engineering Safeguards Engineered safeguards can be as simple as a light switch cover or a door on the breaker panel.

What If Engineering Safeguards Are Removed? A missing cover screw caused this cover to fall onto the plug, which was not fully inserted, & resulted in a short circuit and damaged outlet. The outlet cover is metal. Metal is still used in many areas. It is safe if the cover is installed correctly. The plug would be safe if it was installed correctly. Engineering controls require proper installation to ensure safety. In this case, improper installation caused the short.

Internal Barriers Internal barriers on some equipment ensure workers are not exposed to energized parts Barriers may be as simple as covers over terminal posts or Plexiglas® panels Sandia requires Nationally Recognized Testing Laboratory (NRTL) certified equipment and components (e.g. UL) Purchase of non-NRTL equipment, when certified equipment is available, is not permissible Plexiglas cover over energized doors is an engineered control.

Internal Barriers At Sandia, Ground Fault Circuit Interrupters (GFCIs) are required under the following conditions: Damp or wet location Within 6 feet of exterior door Within 6 feet of signs Outdoors Rooftops If a GFCI outlet is not available, portable GFCIs are an alternative.

Module 2 - Review Questions 1. Portable GFCI-protected extension cords should be used when using portable tools outdoors or in any damp or wet location. a) True b) False A light switch in your office has a missing cover. It is an unsafe condition because the cover is an engineering control and designed to work only if installed properly.

Module 3: Administrative Controls Objective Identify administrative controls that SNL employs to prevent electric shock

What is an Administrative Control? Administrative controls relate to organization and management, procedures, record keeping, assessment, and reporting necessary to ensure safe operation of a facility Examples: Work planning/control documents Work-related training and certifications Warning signs, labels, and tags

National Fire Protection Association (NFPA) 70E Requirements NFPA 70E (Electrical Safety in the Workplace) identifies requirements to maintain a safe electrical workplace NFPA 70E has two categories for electrical hazards: 1. Shock hazards 2. Arc flash hazards Unqualified personnel must be escorted by a qualified person to enter a shock or arc flash boundary Qualified person must ensure unqualified person has required PPE & understands hazards/required controls Qualification requires employees to have knowledge about the work and equipment they will be working on

Excavation/Penetration Permits Hidden hazards are sources of energy that are not visibly apparent, such as underground electrical conduit or wiring inside walls There are specific requirements for excavation and drilling into walls Obtain Excavation or Penetration Permit per FMOC ES&H Specification 01065 requirements

Electrical Lockout/Tagout (LOTO) The most important administrative control is Lockout/Tagout If you see a lock on an electrical circuit, do not attempt to operate the circuit. To gain access to a locked & tagged out circuit, contact the person named on the tag. Do not remove the tag or restore the circuit without approval. If and when possible, a qualified worker will restore the circuit in accordance with the LOTO procedure. Electrical locking devices may be installed on a cord, switch, breaker, or disconnect device: look before you operate the equipment. Be sure to follow your company’s LOTO program.

Pre-Work Briefings A pre-work briefing is the best way to identify hazards, answer questions, and plan work. They improve productivity, reduce accidents/injuries, and improve communications between all levels of the organization Work at SNL is regulated by DOE, affects more people, and can have more serious consequences if safe procedures are not followed.

Module 3 - Review Questions 1. What are the requirements for performing electrical work? You must be trained and qualified You must know the controls & have the appropriate PPE You must understand the electrical hazard All the above What are some common electrical hazards that cause concerns for workers? Sand trap and rough hazards Hidden and overhead hazards Tripping and lifting hazards Who installs the LOTO on an electrical circuit? A qualified electrician Person requesting the work LOTO authorized worker exposed to electrical hazard

Module 4 – Hazard Recognition & Avoidance Objective Identify hazards associated with electrical systems and equipment Discuss electrical accident prevention through increased awareness of surrounding conditions and Sandia requirements Accident prevention is a deliberate, planned series of events that includes training, awareness, design considerations, procedures, and management support NFPA70E requires SNL’s electrical safety program to instill safety principles in employees. Safety, particularly electrical safety, is a mind set. Since electricity is part of everyday life, it is easy to overlook potential hazards.

Overhead Hazards Specific requirements for working in the vicinity of overhead power lines: Transit: Equipment not performing its primary function (i.e., traveling under power lines) may not come within 4’ of energized overhead lines. Standoff Distance: Operating equipment may not approach energized power lines closer than 10’. This distance increases if the voltage in the lines is greater than 50,000 volts. Trained Operators: Anyone working near energized power lines must be trained on the specific hazards associated with working on those lines.

Overhead Hazards In 2006 several accidents across the U.S. were caused by inadvertent contact with overhead power lines. The Department of Labor reports that more than 100 workers are killed every year due to contact with overhead power lines.

Missing Ground Pin The ground pin is missing in this picture. You might say no problem – the plug still fits in the outlet. Is this plug safe? With no engineered ground, you and the tool could easily become the path to ground for current. If the tool experienced an internal short circuit or made contact with a hidden, energized wire, the metallic housing and anyone touching it would become energized. In a case like this, a fatal shock could be delivered.

Burned Insulation In this picture, a section of insulation is burned and missing. If you were using this in your office, and the exposed portions contacted the metal chair you are sitting on, you would probably receive a shock.

Shorted Nightlight Tired of looking at a night light, and believing the easiest way to remove it from the wall was to pry it loose with a butter knife, a woman quickly found out that the butter knife was not the right tool to use. The results are evident. When the conductive knife contacted the energized blades of the night light, the knife shorted across the energized blades, creating a short circuit. The woman using the knife was okay. However, this short circuit could have been avoided had she planned the job and applied safe work practices.

Integrated Safety Management System (ISMS) Appling these ISMS principles to all the work that you do will help create a safe working environment for you and the people you work with and around: Plan Work Analyze Hazards Control Hazards Perform Work Feedback and Improve

Module 4 Review Questions Using a three-pronged cord with the round ground pin broken is a bad idea because: You might scratch yourself on the broken pin If equipment fails internally, the connection to ground could be through your body, causing an electric shock. It's not a bad idea. I do it all the time. You request electrical support to identify potential electrical hazards. You observe the electrician reaching into an electrical distribution panel without PPE. You should: Not worry - the electrician knows what he's doing Suspend work and ask the electrician if PPE is required for the task (always look out for each other) Move up next to the electrician to get a better view

Module 4 –SUMMARY There are four facts to remember about electricity: Water and electricity do not mix. Inspect all equipment prior to use and do not use damaged equipment. Employ ISMS principles: Plan work; analyze hazards; control hazards (with PPE, correct tools etc.); perform work; and feedback & improve. Use common sense - ask questions if you do not understand, and, if not satisfied with the answer, shut down unsafe work practices.

FINAL TEST Two major components of electricity are: Voltage and current Current and amps Flow and resistance Dams and streams

FINAL TEST Your coworker just reported receiving an electrical shock. He appears to be fine. What two things MUST be done? Call 911 and de-energize the source. Call 911 and inform your superintendent or foreman. Ensure the location is placed in a safe condition and escort the coworker to a medical provider. Escort the coworker to a medical provider and inform your superintendent or foreman.

FINAL TEST The difference between an engineered control and an administrative control is: Engineered controls are based on employee actions: administrative controls depend on PPE. Engineered controls are based on location: administrative controls are based on temperature. Engineered controls are designed into the equipment: administrative controls are based on employee actions. Engineered controls rely on PPE: administrative controls rely on paperwork.

FINAL TEST 4. Ground fault circuit interrupter (GFCI) outlets must be installed on all outlets: Outdoors Damp or wet locations All of the above Within 6 feet of sinks Three examples of administrative controls are: Operating procedures, locks & tags, cover plates Signs, TWDs, extension cords Procedures, signs, NFPA 70E NFPA 70E, multimeters, extension cords

FINAL TEST 6. Pre-work briefings have been determined to: Improve productivity Decrease productivity Improve workplace morale Reduce absenteeism 7. When starting a new task where exposure to electricity may occur, you should: Carefully plan your work to minimize or avoid electrical exposure. Identify and control the electrical hazard. Perform work in such a way as to comply with all safety requirements. All of the above

Remember . . . Be Careful Out There! ~ The End ~