Low Cost Stand-alone Renewable Photovoltaic/Wind Energy Utilization Schemes Prof. Dr. A. M. Sharaf.

Slides:



Advertisements
Similar presentations
Grid Connect Inverters NUER 19
Advertisements

Ch8 Inverters (converting DC to AC)
ECE Electric Drives Topic 6: Voltage-Fed Converters Spring 2004.
ELECTRIC DRIVES Ion Boldea S.A.Nasar 1998 Electric Drives.
Electric Drives FEEDBACK LINEARIZED CONTROL Vector control was invented to produce separate flux and torque control as it is implicitely possible.
A NOVEL EFFICIENT STAND- ALONE PHOTOVOLTAIC DC VILLAGE ELECTRICITY SCHEME A.M. Sharaf, SM IEEE, and Liang Yang Department of Electrical and Computer Engineering.
Low Cost Stand-alone Renewable Photovoltaic/Wind Energy Utilization Schemes by Liang Yang Supervisor: Dr. A. M. Sharaf.
A NOVEL MAXIMUM POWER TRACKING CONTROLLER FOR A STAND-ALONE PHOTOVOLTAIC DC MOTOR DRIVE A.M. Sharaf, SM IEEE, and Liang Yang Department of Electrical and.
Power Electronics Lecture-1 Introduction Dr. Imtiaz Hussain
Three-Phase AC machines Three-Phase Cage Rotor Induction Motor – Electronic Methods of Starting and Speed Control Resource 4.
EKT214 - ANALOG ELECTRONIC CIRCUIT II
LECTURE 9 INTRO TO POWER ELECTRONICS
CIRCUITS, DEVICES, AND APPLICATIONS Eng.Mohammed Alsumady
ET3380 Principles and Methods of Electric Power Conversion David Morrisson MS,MBA Week 1.
D ESIGN AND I MPLEMENTATION OF THE D IGITAL C ONTROLLER FOR A F UEL C ELL DC-DC P OWER C ONVERTER SYSTEM O.A. A HMED, J.A.M. B LEIJS.
1 EE462L, Fall 2011 Motor Drives and Other Applications.
Conclusions Innovative application of induction and synchronous generators in autonomous small hydropower plant Prof. M.T.E. Kahn NeuroMorphoGenics/NMG.
1 An FPGA-Based Novel Digital PWM Control Scheme for BLDC Motor Drives 學生 : 林哲偉 學號 :M 指導教授 : 龔應時 IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL.
Sliding Mode Control of Wind Energy Generation Systems Using PMSG and Input-Output Linearization Xiangjun Li, Wei Xu, Xinghuo Yu and Yong Feng RMIT University,
AN-NAJAH NATIONAL UNIVERSITY DEPARTMENT OF ELECTRICAL ENGINEERING Investigation On a Microcontroller-Triggered Single Phase Thyristor Bridge PREPARED BY:
Clemson University Electric Power Research Association CHANDANA BOMMAREDDY CLEMSON UNIVERSITY DG VOLTAGE CONTROL IN AN ISLANDING MODE OF OPERATION.
TECHNICAL PAPER ON SIMULTANEOUS AC-DC POWER TRANSMISSION
SMJE 2103 Synchronous Generator. Scope of discussion 1)Construction 2)Rotation speed 3)Generated voltage 4)Equivalent circuit 5)Power and Torque 6)Testing.
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
Types Of Thyristors And Their Applications
Chapter 6: Voltage Regulator
Flexible AC Transmission FACTS-Technology and Novel Control Strategies For Power System Stability Enhancement Mohamed Shawky ElMoursi Supervisor Prof.
SOFT START OF 3 PHASE INDUCTION MOTOR BY USING 2 NUMBERS BACK TO BACK SCRS IN EACH PHASE Submitted by:
Last Comments on Control
Introduction to Electric Power System and A. C. Supply
DOUBLE INPUT Z-SOURCE DC-DC CONVERTER
Power Electronics and Control in Wind Energy Conversion Systems
Rectifiers, Inverters & Motor Drives
Importance of DC-DC Transformation in Grids of the Future
A Project Review On POWER QUALITY IMPROVEMENT IN GRID USING STATECOM
DOUBLE INPUT Z-SOURCE DC-DC CONVERTER
Speed control of three phase induction motor
POWER ELECTRONICS & ITS APPLICATION
IG BASED WINDFARMS USING STATCOM
Rectifiers and Filters
Prof. Dr. A. M. Sharaf ECE, UNB, Canada
PROBLEM DEFINITION: In general, various single-input single-output dc–dc converters with different voltage gains are combined to satisfy the requirement.
IMPEDENCE - SOURCE INVERTER FOR MOTOR DRIVES
Lesson 16: Asynchronous Generators/Induction Generators
M.KARTHIK (10F41D4307) Under the esteemed guidance of
Wen Cai Supervisor: Dr. Babak Fahimi December 04, 2015
DESIGN AND SIMULATION OF GRID CONNECTED
Graduation Project-II submitted to:
Wind turbine technology
Converter principles and modelling
Dr. Unnikrishnan P.C. Professor, EEE
DC- AC CONVERTER-INVERTER
Five level diode clapmed inverter
DC and AC Motor Drives.
PID controller for improving Max power point tracking system
APPLICATIONS Reference: Textbook-Chapter 6,8 & 9 'Power Electronics',C
Supervisor : Prof. Dr. A. M. Sharaf
Power Electronic Drives - DC to AC converter / Inverter
General Licensing Class
UNIT-8 INVERTERS 11/27/2018.
Chapter 6: Voltage Regulator
Photovoltaic Systems Engineering Session 10
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
Standalone Wind Energy Utilization Scheme and Novel Control Strategies
CHAPTER – 46 ELECTRONIC CONTROL OF A.C. MOTORS
Chris Leonard and Baylor Howard Advisor: Dr. Jing Wang
FPGA Based Single Phase Motor Control Using Multistep Sine PWM Author Name1, Author Name2., Author Name3, (BE-Stream Name) Under the Guidance Of Guide.
CHAPTER 59 TRANSISTOR EQUIVALENT CIRCUITS AND MODELS
INVERTERS. What is an Inverter? A static device that converts DC power into AC power at desired output voltage and frequency is called an Inverter. Applications.
Presentation transcript:

Low Cost Stand-alone Renewable Photovoltaic/Wind Energy Utilization Schemes Prof. Dr. A. M. Sharaf

Presentation Outline Introduction Research Objectives Low Cost Stand-alone Renewable Photovoltaic/Wind Energy Utilization Schemes and Error Driven Controllers Conclusions and Recommendations for Future Research Publications Questions & Answers

Introduction Photovoltaics (PV) PV cells PV modules PV arrays PV systems: batteries, battery charge controllers, maximum power point trackers (MPPT), solid state inverters, rectifiers (battery chargers), generators, structure

PV cell, PV module and PV array

The Advantages of PV Energy Clean and green energy source that has virtually no environmental polluting impact Highly reliable and needs minimal maintenance Costs little to build and operate Modular and flexible in terms of sizes, ratings and applications

Applications of PV Systems Stand-alone PV energy systems: Small village electricity supply Water pumping and irrigation systems Cathodic protection Communications Lighting and small appliances Emergency power systems and lighting systems Stand-alone hybrid renewable energy systems Electric utility systems

The circuit diagram of the solar cell PV Cell Model Current source: proportional to the light falling on the cell in parallel with a diode: • Temperature dependence of the photo-generated current (Iph). • Temperature dependence of the reverse saturation current of the diode D0 (I0). • Series resistance (Rs): gives a more accurate shape between the maximum power point and the open circuit voltage. • Shunt diode D0 with the diode quality factor set to achieve the best curve match. The circuit diagram of the solar cell

Nonlinear I-V Characteristics of PV Cell

I-V characteristics of a typical PV array with various conditions

PV array equivalent circuit block model using the MATLAB/Simulink/SimPowerSystems software

Maximum Power Point Tracking (MPPT) The photovoltaic system displays an inherently nonlinear current-voltage (I-V) relationship, requiring an online search and identification of the optimal maximum operating power point. MPPT controller is a power electronic DC/DC chopper or DC/AC inverter system inserted between the PV array and its electric load to achieve the optimum characteristic matching PV array is able to deliver maximum available power that is also necessary to maximize the photovoltaic energy utilization

and solar irradiation condition Nonlinear (I-V) and (P-V) characteristics of a typical PV array at a fixed ambient temperature and solar irradiation condition

The Performance of any Stand-alone PV System Depends on: Electric load operating conditions/excursions/ switching Ambient/junction temperature (Tx) Solar insolation/irradiation variations (Sx)

Research Objectives 1. Develop/test/validate full mathematical models for PV array modules and a number of stand-alone renewable photovoltaic and hybrid photovoltaic/wind energy utilization schemes in MATLAB/Simulink/SimPowerSystems software environment.

Research Objectives (Continue) 2. Select parameters to validate a number of novel efficient low cost dynamic error driven maximum photovoltaic power tracking controllers developed by Dr. A.M. Sharaf for four novel low cost stand-alone renewable photovoltaic and hybrid photovoltaic/wind energy utilization schemes: Photovoltaic Four-Quadrant PWM converter PMDC motor drive scheme: PV-DC Scheme I. Photovoltaic DC/DC dual converter scheme: PV-DC Scheme II. Photovoltaic DC/AC six-pulse inverter scheme: PV-AC Scheme. Hybrid renewable photovoltaic/wind energy utilization scheme: Hybrid PV/Wind Scheme.

Low Cost Stand-alone Renewable Photovoltaic/Wind Energy Utilization Schemes and Error Driven Controllers Photovoltaic Four-Quadrant PWM converter PMDC motor drive scheme: PV-DC Scheme I. Photovoltaic DC/DC dual converter scheme: PV-DC Scheme II. Photovoltaic DC/AC six-pulse inverter scheme: PV-AC Scheme. Hybrid renewable photovoltaic/wind energy utilization scheme: Hybrid PV/Wind Scheme.

Photovoltaic Four-Quadrant PWM Converter PMDC Motor Drive Scheme: PV-DC Scheme I Photovoltaic powered Four-Quadrant PWM converter PMDC motor drive system (Developed by Dr. A.M. Sharaf)

Four-quadrant Operation of PWM Converter PMDC motor drive Quadrant 1: Forward motoring (buck or step-down converter mode) Q1–on Q2–chopping Q3–off Q4–off Current freewheeling through D3 and Q1 Quadrant 2: Forward regeneration (boost or step-up converter mode) Q1–off Q2–off Q3–off Q4–chopping Current freewheeling through D1 and D2 Quadrant 3: Reverse motoring (buck converter mode) Q1–off Q2–off Q3–on Q4–chopping Current freewheeling through D1 and Q3 Quadrant 4: Reverse regeneration (boost converter mode) Q1–off Q2–chopping Q3–off Q4 – off Current freewheeling through D3 and D4

Variations of Ambient Temperature and Solar Irradiation Variation of solar irradiation (Sx) Variation of ambient temperature (Tx)

Dynamic Error Driven Proportional plus Integral (PI) Controller Dynamic tri-loop error driven Proportional plus Integral control system

Digital Simulation Results with PI Controller for Trapezoidal Reference Speed Trajectory

Digital Simulation Results with PI Controller for Trapezoidal Reference Speed Trajectory (Continue)

Digital Simulation Results with PI Controller for Sinusoidal Reference Speed Trajectory

Digital Simulation Results with PI Controller for Sinusoidal Reference Speed Trajectory (Continue)

Dynamic Error Driven Self Adjusting Controller (SAC) Dynamic tri-loop self adjusting control (SAC) system

Digital Simulation Results with SAC for Trapezoidal Reference Speed Trajectory

Digital Simulation Results with SAC for Trapezoidal Reference Speed Trajectory (Continue)

Digital Simulation Results with SAC for Sinusoidal Reference Speed Trajectory

Digital Simulation Results with SAC for Sinusoidal Reference Speed Trajectory (Continue)

Photovoltaic DC/DC Dual Converter Scheme: PV-DC Scheme II Stand-alone photovoltaic DC/DC dual converter scheme for village electricity use

Dynamic Error Driven Proportional plus Integral (PI) Controller Dynamic tri-loop error driven Proportional plus Integral control system

Digital Simulation Results with PI Controller Without controller With PI controller

Digital Simulation Results with PI Controller (Continue) Without controller With PI controller

Dynamic Error Driven Variable Structure Sliding Mode Controller (SMC) Dynamic dual-loop error driven variable structure Sliding Mode Control (SMC) system

Switching surface in the (et-ėt) phase plane

Digital Simulation Results with SMC Without controller With SMC

Digital Simulation Results with SMC (Continue) Without controller With SMC

Photovoltaic DC/AC Six-pulse Inverter Scheme: PV-AC Scheme Stand-alone photovoltaic DC/AC six-pulse inverter scheme for village electricity use

Variations of Ambient Temperature and Solar Irradiation Variation of ambient temperature (Tx) Variation of solar irradiation (Sx)

Dynamic Error Driven Proportional plus Integral (PI) Controller Dynamic tri-loop error driven Proportional plus Integral control system

Digital Simulation Results with PI Controller Without controller With PI controller

Digital Simulation Results with PI Controller (Continue) Without controller With PI controller

Dynamic Error Driven Variable Structure Sliding Mode Controller (SMC) Dynamic tri-loop error driven variable structure Sliding Mode Control (SMC) system

Digital Simulation Results with SMC Without controller With SMC

Digital Simulation Results with SMC (Continue) Without controller With SMC

Hybrid Renewable Photovoltaic/Wind Energy Utilization Scheme: Hybrid PV/Wind Scheme Stand-alone hybrid photovoltaic/wind energy utilization scheme for village electricity use

Variations of Wind Speed (Vw) Variation of wind speed (Vw)

Dynamic Error Driven Proportional plus Integral (PI) Controller Dynamic tri-loop error driven Proportional plus Integral control system

Digital Simulation Results with PI Controller Without controller With PI controller

Digital Simulation Results with PI Controller (Continue) Without controller With PI controller

The loop weighting factors (γv, γi and γp) and control gains (Kp, Ki) are assigned to minimize a selected time weighted excursion index J0 where is the magnitude of the hyper-plane error excursion vector N= T0/Tsample T0: Largest mechanical time constant in the hybrid system (10s) Tsample: Sampling time (0.2ms)

Time Weighted Excursion Index J0 Digital simulation results of time weighted excursion index J0 with different proportional and integral gains

Conclusions and Recommendations for Future Research (I) 1. The full mathematical models for PV array modules were fully developed including the inherently nonlinear I-V characteristics and variations under ambient temperature and solar irradiation conditions. 2. The proposed stand-alone renewable photovoltaic and hybrid photovoltaic/wind energy utilization schemes and robust dynamic control strategies were digitally simulated and validated using the MATLAB/Simulink/SimPowerSystems software environment. 3. The dynamic controllers require only the measured values of voltage and current signals in addition to the motor speed signals that can be easily measured with low cost sensors and transducers. 4. The proposed low cost stand-alone renewable photovoltaic and hybrid photovoltaic/wind energy utilization schemes are suitable for resort/village electricity application in the range of (1500 watts to 50000 watts), mostly for water pumping, ventilation, lighting, irrigation and village electricity use in arid remote communities.

Proposed Schemes, Controllers and Applications  

Conclusions and Recommendations for Future Research (II) 1. It is necessary to validate the proposed novel dynamic maximum photovoltaic power tracking control strategies by a specific laboratory facility using the low cost micro controllers. 2. The proposed dynamic effective and robust error driven control strategies can be extended to other control system applications. They are also flexible by adding supplementary control loops to adapt any control objectives of any systems. Further work can be focused on Artificial Intelligence (AI) control strategies. 3. The research can be expanded to the design and validation of dynamic FACTS with stabilization and compensation control strategies for other stand-alone renewable energy resource schemes as well as grid-connected renewable energy systems to make maximum utilization of the available energy resources.

Publications [1] A.M. Sharaf, Liang Yang, "A Novel Tracking Controller for a Stand-alone Photovoltaic Scheme," International Conference on Communication, Computer and Power (ICCCP'05), Muscat, Sultanate of Oman, Feb. 14-16, 2005 (Accepted). [2] A.M. Sharaf, Liang Yang, "A Novel Maximum Power Tracking Controller for a Stand-alone Photovoltaic DC Motor Drive," 18th Annual Canadian Conference on Electrical and Computer Engineering (CCECE05), Saskatoon, Canada, May 1-4, 2005 (Accepted). [3] A.M. Sharaf, Liang Yang, "A Novel Low Cost Stand-alone Photovoltaic Scheme for Four Quadrant PMDC Motor Drive," International Conference on Renewable Energy and Power Quality (ICREPQ'05), Zaragoza, Spain, March 16-18, 2005 (Submitted). [4] A.M. Sharaf, Liang Yang, "An Efficient Photovoltaic DC Village Electricity Scheme Using a Sliding Mode Controller," 2005 IEEE Conference on Control Applications (CCA05), Toronto, Canada, August 28-31, 2005 (Submitted). [5] A.M. Sharaf, Liang Yang, "A Novel Efficient Stand-alone Photovoltaic Energy Utilization Scheme for Village Electricity," 8th International Conference on Electrical Power Quality and Utilization, Cracow, Poland, September 21-23, 2005 (Submitted). [6] A.M. Sharaf, Liang Yang, "A Novel Efficient Stand-alone Hybrid Photovoltaic/Wind Energy Utilization Scheme for Village Electricity," International Conference on Electrical Drives and Power Electronics, Dubrovnik, Croatia, September 26-28, 2005 (Submitted). [7] A.M. Sharaf, Liang Yang, "Novel Dynamic Control Strategies for Efficient Utilization of a Stand-alone Photovoltaic System," Electric Power Systems Research (Submitted).

Standalone Wind Energy Utilization Scheme and Novel Control Strategies Prof. Dr. A. M. Sharaf

Outline Introduction Stand-alone WECS with Dynamic Series Switched Capacitor Scheme Stand-alone WECS with Dynamic Series/Parallel Compensation Scheme Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme

Outline Stand-alone WECS with Universal DC-Link Compensation Scheme Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme Conclusions and Recommendations Models Publications

1.Introduction 1.1 Wind Energy Wind energy: one of the most significant, alternative energy resources. Most wind turbines use the three phase asynchronous induction generator for it is low lost, reliable and less maintenance. However, the voltage stability problem of a wind driven induction generator system is fully dependent on wind gusting conditions and electrical load changes. New interface technologies are needed

1.Introduction 1.2 Wind Energy Conversion Schemes Six novel techniques and compensation schemes developed by Dr. Sharaf in this thesis are proposed. Dynamic Series Switched Capacitor (DSSC) Dynamic Series/Parallel Capacitor (DSPC) Dynamic Hybrid Power Compensation (DHPC) Dynamic Dual-switching Universal Power Compensation 1 and 2 (DUPC1&2) Universal DC-Link Compensation (UDCC)

1.Introduction 1.2 Wind Energy Conversion Schemes Six PWM switched controllers developed by Dr. Sharaf are studied in this thesis . Aux controller. Tri-loop (voltage, current and power signals) error driven PID controller. Dual-loop (voltage and current) error driven PID controller. Tri-loop nonlinear self-adjusting Tan-sigmoid controller Voltage regulator controller. Tri-loop error driven sliding mode controller.

Standalone Wind Energy Utilization Scheme and Novel Control Strategies Prof. Dr. A. M. Sharaf

Outline Introduction Stand-alone WECS with Dynamic Series Switched Capacitor Scheme Stand-alone WECS with Dynamic Series/Parallel Compensation Scheme Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme

Outline Stand-alone WECS with Universal DC-Link Compensation Scheme Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme Conclusions and Recommendations Models Publications

1.Introduction 1.1 Wind Energy Wind energy: one of the most significant, alternative energy resources. Most wind turbines use the three phase asynchronous induction generator for it is low lost, reliable and less maintenance. However, the voltage stability problem of a wind driven induction generator system is fully dependent on wind gusting conditions and electrical load changes. New interface technologies are needed

1.Introduction 1.2 Wind Energy Conversion Schemes Six novel techniques and compensation schemes developed by Dr. Sharaf in this thesis are proposed. Dynamic Series Switched Capacitor (DSSC) Dynamic Series/Parallel Capacitor (DSPC) Dynamic Hybrid Power Compensation (DHPC) Dynamic Dual-switching Universal Power Compensation 1 and 2 (DUPC1&2) Universal DC-Link Compensation (UDCC)

1.Introduction 1.2 Wind Energy Conversion Schemes Six PWM switched controllers developed by Dr. Sharaf are studied in this thesis . Aux controller. Tri-loop (voltage, current and power signals) error driven PID controller. Dual-loop (voltage and current) error driven PID controller. Tri-loop nonlinear self-adjusting Tan-sigmoid controller Voltage regulator controller. Tri-loop error driven sliding mode controller.

1.Introduction 1.3 Standalone WECS Components The Stand-alone WECS comprises the following main components (1) Wind Turbine (2) Gear Box (3) Induction or Synchronous Generator (see the appendix A.2 for generator models) (4) Stabilization Interface Scheme and Stabilization Controller (5) The Electric Load

1.Introduction 1.3 Standalone WECS Components

Figure 2.1 depicts the sample WECS with Dynamic Chap2. Stand-alone WECS with Dynamic Series Switched Capacitor Scheme 2.1 Stand-alone WECS Modeling and Description Figure 2.1 depicts the sample WECS with Dynamic Series Switched Capacitor (DSSC) scheme WECS Parameters are shown in Appendix A.1

Chap2. Stand-alone WECS with Dynamic Series Switched Capacitor Scheme 2.2 DSSC Compensation Scheme Figure 4 depicts DSSC Stabilization Scheme using Back to Back Gate Turn off GTO switching Device (per phase).

Chap2. Stand-alone WECS with Dynamic Series Switched Capacitor Scheme 2.3 Proposed Dynamic Control System Figure 2.3 depicts Tri-loop Error Driven PID Controlled PWM Switching Scheme How the Controller Parameters are selected is Shown in Appendix A.3 And the PWM model is shown in Appendix A.4

Chap2. Stand-alone WECS with Dynamic Series Switched Capacitor Scheme 2.4 Digital Simulation and Results Figure 2.4 below is the Unified Sample Study A.C Systems Matlab/Simulink Functional Model

Chap2. Stand-alone WECS with Dynamic Series Switched Capacitor Scheme 2.4 Digital Simulation and Results Case one: under electrical load excursion a) Under linear and non-linear load excursion from 0.1s to 0.3s, we apply 50% (100kVA) linear load; from 0.4s-0.6s, we apply 60% (120kVA) non-linear load. The figures below showed us the dynamic response of generator voltage without and with DSSC compensation scheme Without DSSC Compensation With DSSC Compensation

Chap2. Stand-alone WECS with Dynamic Series Switched Capacitor Scheme 2.4 Digital Simulation and Results Case one: under electrical load excursion b) Under Motor load excursion from 0.2s to 0.4s, we apply a 20% (20kVA) induction motor load The figures below showed us the dynamic response of generator voltage without and with DSSC compensation scheme Without DSSC Compensation With DSSC Compensation

Chap2. Stand-alone WECS with Dynamic Series Switched Capacitor Scheme 2.4 Digital Simulation and Results Case two: under wind excursion From 0.3s-0.6s, the wind speed was decreased to 6m/s from 10m/s The figures below showed us the dynamic response of generator voltage without and with DSSC compensation scheme Without DSSC Compensation With DSSC Compensation

Chap2. Stand-alone WECS with Dynamic Series Switched Capacitor Scheme 2.5 Conclusions The DSSC Facts compensation scheme is effective for generator bus voltage stabilization of the linear, non-liner load excursions as well as wind speed excursions. But it can not compensate for large induction motor excursion. Tri-loop dynamic error driven PID controller works well to control the compensation scheme

Chap3. Stand-alone WECS with Dynamic Series/Parallel Switched Capacitor Scheme 3.1 Stand-alone WECS Modeling and Description Figure 3.1 depicts the sample full stand-alone wind energy system with squirrel cage induction generator, hybrid load and DSPC compensation

Chap3. Stand-alone WECS with Dynamic Series/Parallel Switched Capacitor Scheme 3.2 DSPC Compensation Scheme Figure 3.2 showed Low Cost Dynamic Series/Parallel Capacitor Compensations Stabilization Scheme using the Back to Back Gate Turn off GTO1&2 switching Devices (Per phase)

Chap3. Stand-alone WECS with Dynamic Series/Parallel Switched Capacitor Scheme 3.3 Proposed Dynamic Control System Figure 3.3 showed the Tri-loop nonlinear Self-adjusting Tan-sigmoid Controller

Chap3. Stand-alone WECS with Dynamic Series/Parallel Switched Capacitor Scheme 3.3 Matlab Digital Simulation and Results Figure 3.4 below is the Unified Sample Study A.C Systems Matlab/Simulink Functional Model

Chap3. Stand-alone WECS with Dynamic Series/Parallel Switched Capacitor Scheme 3.3 Matlab Digital Simulation and Results Case one: under electrical load excursion a) Under linear and non-linear load excursion from 0.1s to 0.3s, we apply 50% (100kVA) linear load; from 0.4s-0.6s, we apply 60% (120kVA) non-linear load. The figures below showed us the dynamic response of generator voltage without and with DSPC compensation scheme Without DSPC Compensation With DSPC Compensation

Chap3. Stand-alone WECS with Dynamic Series/Parallel Switched Capacitor Scheme 3.3 Matlab Digital Simulation and Results Case one: under electrical load excursion b) Under Motor load excursion from 0.2s to 0.4s, we apply a 20% (20kVA) induction motor load The figures below showed us the dynamic response of generator voltage without and with DSPC compensation scheme Without DSPC Compensation With DSPC Compensation

Chap3. Stand-alone WECS with Dynamic Series/Parallel Switched Capacitor Scheme 3.3 Matlab Digital Simulation and Results Case Two: under wind excursion From 0.3s-0.6s, the wind speed was decreased to 6m/s from 10m/s The figures below showed us the dynamic response of generator voltage without and with DSPC compensation scheme Without DSPC Compensation With DSPC Compensation

Chap3. Stand-alone WECS with Dynamic Series/Parallel Switched Capacitor Scheme 3.4 Conclusions The Matllab/Simulink simulations validate that the DSPC compensation are very effective for the electric linear, non-liner, motor excursion and wind excursion. The proposed low cost DSPC voltage compensation scheme is suitable for isolated wind energy conversion systems feeding linear and non-liner and motor type loads The tri-loop nonlinear self-adjusting tan-sigmoid controller is effective for controlling the compensation scheme.

Chap4. Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme 4.1 Stand-alone WECS Modeling and Description Figure 4.1 showed Stand Alone Wind Energy Conversion Scheme Diagram with Hybrid Electric Load

Chap4. Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme 4.2 Dynamic Hybrid Power Compensation scheme Figure 4.2: Dynamic Hybrid Power Compensation (DHPC) Stabilization Scheme using the Back to Back Gate Turn off GTO and 6 Pulse VSC-PWM Controller (3 phase)

Chap4. Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme 4.2 Dynamic Hybrid Power Compensation scheme Figure 4.3 below is the 6 Pulse Thyristor- VSC Converter

Chap4. Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme 4.3 Proposed Dynamic Control System Figure 4.4 is the Tri-loop Error Driven PID Controller

Chap4. Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme 4.4 Digital Simulation and Results Figure 4.5 is the Unified Sample Study A.C Matlab/ Simulink Functional System Model

Chap4. Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme 4.4 Digital Simulation and Results Case one: under electrical load excursion a) Under linear and non-linear load excursion from 0.1s to 0.3s, we apply 50% (100kVA) linear load; from 0.4s-0.6s, we apply 60% (120kVA) non-linear load. The figures below showed us the dynamic response of generator voltage without and with DHPC compensation scheme Without DHPC Compensation With DHPC Compensation

Chap4. Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme 4.4 Digital Simulation and Results Case one: under electrical load excursion b) Under Motor load excursion from 0.2s to 0.4s, we apply a 20% (20kVA) induction motor load The figures below showed us the dynamic response of generator voltage without and with DHPC compensation scheme Without DHPC Compensation With DHPC Compensation

Chap4. Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme 4.4 Digital Simulation and Results Case two: under wind excursion From 0.3s-0.6s, the wind speed was decreased to 6m/s from 10m/s The figures below showed us the dynamic response of generator voltage without and with DHPC compensation scheme Without DHPC Compensation With DHPC Compensation

Chap4. Stand-alone WECS with Dynamic Hybrid Power Compensation Scheme 4.5 Conclusions Digital simulation results validate that this new DHPC scheme is very effective for bus voltage stabilization under electric load disturbance including linear, non-linear load and motor load excursions. The proposed novel tri-loop dynamic controller is very effective for the compensation scheme.

Chap5. Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme 5.1 Stand-alone WECS Modeling and Description Figure 5.1 showed Stand Alone Wind Energy Conversion Scheme Diagram with Hybrid Electric Load

Chap5. Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme 5.2 Dual-switching Universal Power Compensation 1 Scheme Figure 5.2 depicts Dual-switching Universal Power Compensation1 (DUPC1) Stabilization Scheme using the 6 Pulse VSC-PWM Controller and IGBT

Chap5. Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme 5.3 Proposed Dynamic Control System In this research we used two novel controllers, dual-loop error driven PID controller and Aux Controller Figure 5.3 is the Dual-loop Error Driven PID Controller

Chap5. Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme 5.3 Proposed Dynamic Control System Figure 5.4 below showed the Aux Controller

Chap5. Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme 5.4 Matlab/Simulink Digital Simulation and Results Figure 5.5 is the Unified Sample Study A.C Matlab/Simulink Functional System Model

Chap5. Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme 5.4 Matlab/Simulink Digital Simulation and Results Case one: under electrical load excursion a) Under linear and non-linear load excursion from 0.1s to 0.3s, we apply 50% (100kVA) linear load; from 0.4s-0.6s, we apply 60% (120kVA) non-linear load. The figures below showed us the dynamic response of generator voltage without and with DUPC1 compensation scheme Without DUPC1 Compensation With DUPC1 Compensation

Chap5. Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme 5.4 Matlab/Simulink Digital Simulation and Results Case one: under electrical load excursion b) Under Motor load excursion from 0.2s to 0.4s, we apply a 20% (20kVA) induction motor load The figures below showed us the dynamic response of generator voltage without and with DUPC1 compensation scheme Without DUPC1 Compensation With DUPC1 Compensation

Chap5. Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme 5.4 Matlab/Simulink Digital Simulation and Results Case two: under wind excursion From 0.3s-0.6s, the wind speed was decreased to 6m/s from 10m/s The figures below showed us the dynamic response of generator voltage without and with DUPC1 compensation scheme Without DUPC1 Compensation With DUPC1 Compensation

Chap5. Stand-alone WECS with Dual-switching Universal Power Compensation 1 Scheme 5.5Conclusions This new DUPC1 compensator scheme is very effective in stabilizing generator bus voltage as well as enhancing power/energy utilization under favorable wind gusting conditions The novel dual-loop dynamic controller is extremely flexible and can be easily modified to include other supplementary loops such as generator power

Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.1 Standalone Wind Energy Conversion Scheme Description Figure B.1: Stand Alone Wind Energy Conversion Scheme Diagram with Hybrid Load and Universal Power Compensator

Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.2 Universal DC-Link Compensation Scheme Figure B.2: Universal DC-Link (Rectifier-DC-Link-Inverter) Scheme using 6 Pulse Diode and 6 Pulse GTO (3 phase)

Referred to Matlab/Demo Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.3 Proposed Dynamic Control System In this research we used a Voltage Regulator Controller (VRC). The figure below shows the structure of the controller. Referred to Matlab/Demo

Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.4 Matlab Digital Simulation and Results Figure B.4 show the stand-alone wind energy system model and wind subsystem model

Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.4 Matlab Digital Simulation and Results Figure B.5 is the Wind Subsystem Model

Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.4 Matlab Digital Simulation and Results Case one: under electrical load excursion a) Under linear and non-linear load excursion from 0.1s to 0.3s, we apply 50% (100kVA) linear load; from 0.4s-0.6s, we apply 60% (120kVA) non-linear load. Without UDCC Compensation With UDCC Compensation

Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.4 Matlab Digital Simulation and Results Case one: under electrical load excursion b) Under Motor load excursion from 0.2s to 0.4s, we apply a 20% (20kVA) induction motor load Without UDCC Compensation With UDCC Compensation

Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.4 Matlab Digital Simulation and Results Case two: under wind excursion From 0.3s-0.6s, the wind speed was decreased to 6m/s from 10m/s Without UDCC Compensation With UDCC Compensation

Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.4 Matlab Digital Simulation and Results Case three: under temporary full short circuit fault (grounding) excursion. From 0.2s to 0.3s, all loads are grounded The figures below showed us the dynamic response of generator voltage without and with UDCC compensation scheme Without UDCC Compensation With UDCC Compensation

Appendix B Stand-alone WECS with Universal  DC-Link Compensation Scheme B.5 Conclusions This new UDCC compensator scheme is very effective in stabilizing the generator bus voltage under all electric loads and wind gusting conditions as well as full three phase short circuit fault. the UDCC Facts-device showed its special advantage that it can compensate for full three phase short circuit fault. The Voltage stabilization is complex and suitable in large wind farm utilization scheme with one load collection center

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.1 Standalone WECS Description Figure C.1 showed the Wind-Diesel Standalone Energy Conversion Scheme Diagram with Hybrid Electric Load and Switching DUPC2 Scheme

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.2 Dual-switching Universal Power Compensation Scheme2 Figure C.2 showed Dual Switching Universal Power Compensation (DUPC2) Scheme2

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.3 Proposed Novel Controller System Figure C.3 is the Tri-loop Error Driven Sliding Mode Controlled PWM Switching Scheme with Dynamic Switching Surface

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.4 Matlab/Simulink Digital Simulations and Results Figure C.4 below is the Unified Sample Study A.C Matlab/Simulink Functional System Model

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.4 Matlab/Simulink Digital Simulations and Results Figure C.5 is the Diesel Driven Synchronous Generator Energy Subsystem Matlab/Simulink Model The details of the Diesel Engine are shown in Appendix A.5

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.4 Matlab/Simulink Digital Simulations and Results Case one: under electrical load excursion (Wind driven generator energy system only, no diesel driven generator) a) Under linear and non-linear load excursion from 0.1s to 0.3s, we apply 50% (100kVA) linear load; from 0.4s-0.6s, we apply 60% (120kVA) non-linear load. Without DUPC2 Compensation With DUPC2 Compensation

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.4 Matlab/Simulink Digital Simulations and Results Case one: under electrical load excursion (Wind driven generator energy system only, no diesel driven generator) b) Under motor load excursion from 0.2s to 0.4s, we apply a 20% (20kVA) induction motor load Without DUPC2 Compensation With DUPC2 Compensation

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.4 Matlab/Simulink Digital Simulations and Results Case two: under wind speed excursion (Wind driven generator energy system only, no diesel driven generator) From 0.3s-0.6s, the wind speed was decreased to 6m/s from 10m/s Without DUPC2 Compensation With DUPC2 Compensation

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.4 Matlab/Simulink Digital Simulations and Results Case three: under three phase temporary short circuit fault (Combined wind-diesel energy system) From 0.1s to 0.2s, the system experienced three phase short circuit fault, and from 0.1s to 0.4s the standby diesel generator was put into operation Without DUPC2 Compensation With DUPC2 Compensation

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.4 Matlab/Simulink Digital Simulations and Results Case Four: Under the Diesel Engine Mechanical Output Power Excursions (Combined wind-diesel energy system) From 0.2-0.3sec the output of diesel engine mechanical power increases 100% (0.3pu) and from 0.3-0.4sec it decrease 100% (0.3pu). Voltage of Gen Bus Current of Gen Bus P&Q of Gen Bus

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.4 Matlab/Simulink Digital Simulations and Results Voltage of Load Bus Current of Load Bus P&Q of Load Bus

Appendix C Wind-Diesel Standalone Energy System Using Dual-switching Universal Power Compensation2 Scheme B.5 Conclusions The DUPC2 compensation scheme is very effective for voltage stabilization under the linear, non-liner and motor load excursions as well as wind speed and diesel on-off excursions. During emergency three phase short circuit fault condition, the standby diesel generator can keep the voltage of the generator bus at 1.0pu. The proposed wind/ diesel energy system combined with stabilization scheme DUPC2 is fully suitable for all isolated wind energy conversion systems in the range 0.5-2MW.

Chapter 6 Conclusions and Recommendations 6.1 Conclusions Six schemes developed by Dr.A.M.Sharaf are fully validated and compared in table 1 next slide. 1: Dynamic Series Switched Capacitor compensation scheme (DSSC) 2: Dynamic Series/Parallel Capacitor compensation scheme (DSPC) 3: Dynamic Hybrid Power Compensation scheme (HPC) 4: Dual-switching Universal Power Compensation scheme1 (DUPC1) 5:Universal DC-Link Compensation scheme (UDCC) 6:Dual-switching Universal Power Compensation scheme2 (DUPC2)

Chapter 6 Conclusions and Recommendations 6.1 Conclusions DSSC DSPC HPC DUPC1 UDCC DUPC2 Elements Switched Series CAPs; Fixed Parallel 1 GTO Series and 2 GTO Switched 6 pulse GTO; DC Cap 6 pulse DC Cap; filter; 2GTO; 1 IGBT Diode; RLC switched 1GTO; 2IGBT Controller Used Tri-loop PID Tan- sigmoid Dual-loop PID; Aux Voltage Regulator Sliding Mode Switching PWM (200 Hz) (195Hz) (195 Hz) (1000 Hz) N/A

Chapter 6 Conclusions and Recommendations 6.1 Conclusions Availability Linear, Nonlinear and wind excursions ,Motor Nonlinear, Motor and wind Motor, full fault Performance Limited Good Better Best Complexity Simple Complex Cost Low Reasonable High Suitable Size (kw) 50-500 500-2000 Large Utility

Chapter 6 Conclusions and Recommendations 6.1 Conclusions Rules of How to Choose Controllers Tri-loop error driven PID controller is suitable and popular for all compensation schemes, but sometimes we are not satisfied with it, so in some cases it is not the best one. When we are not satisfied with tri-loop error driven PID controller, we have to develop or find a new controller for example: the Voltage Regulator Controller which is better than tri-loop error driven PID controller for DUCC. If a simpler controller (for example: dual-loop error driven PID controller and Aux controller) or any other controller (for example: the nonlinear self-adjusted tan-sigmoid controller Tri-loop error driven sliding mode controller) is as good as tri-loop error driven PID controller then we will not use the tri-loop error driven PID controller so that we can have many choices.

Chapter 6 Conclusions and Recommendations 6.1 Extensions The proposed novel stabilization schemes can be extended to other hybrid energy schemes such as solar/small hydro/micro-gas/hydrogen fired turbine/biomass/fuel cell, microgas turbines and hybrid systems. The era of hydrogen technology is dawning with new hybrid fuel technologies using PV/Wind/ Small Hydro to produce hydrogen from water. This hydrogen will be used in remote sites in producing electricity via Fuel Cell large units

Appendix A Models A.1 WECS Parameters Selected of DSSC Scheme A.1.1 Induction Generator (3 phase, 2 pairs of poles) Vg=4160V(L-L), Sg=1MVA, Cself=217uF; A.1.2 Selected Per Unit Base Value Sbase= 1MVA, Vbase=4160V/25kV (Generator/ Transmission Line and Load)

Appendix A Models A.1 WECS Parameters Selected of DSSC Scheme A.1.3 Feeder Line (3 phase) Vline-line =25kV, Length= 20km; Positive sequence parameters: R1= 0.45 Ohms/km, L1= 0.928mH, C1=infinite A1.14 Transformers Generator side: 4160V/1MVA Load Side: 25kV/1MVA/

Appendix A Models A.2 Generator Models A.2.1 3 Phase Induction Generator Model Below is the Induction Generator d-q Model

Appendix A Models A.2 Generator Models Electrical System Equations as Follows (Flux Models) Where Where Where Where

Appendix A Models A.2 Generator Models Mechanical System Equations:

Appendix A Models A.2 Generator Models A.2.2 3 Phase Synchronous Generator Model The electrical model of the machine is

Appendix A Models A.2 Generator Models The Synchronous Machine block implements the mechanical system described by:

Appendix A Models A.3 Controller Parameters Controller parameters are selected by guided trial and error (1) Define an excursion based performance index Where Ns=Tsettling/Tsample, Tsettling=largest mechanical time constant

Appendix A Models A.3 Controller Parameters (2) Select control loop weightings (gamma) to reflect the controller main objective, with the assign the largest loop weight for the voltage loop stabilization. (3) Select different delay times to ensure multi-loop-decoupling and the control priority assignment, ensure dynamic tracking error delay of half cycle for the fast electrical loops and few cycles for the slow mechanical loops. (4) Avoid the creation of any near resonance condition (5) Avoid any control loop/system unstable interaction by ensuring full control loop-decoupling of the multi-loop structure

Appendix A Models A.3 Controller Parameters (6) Select the controller PID parameters to ensure fast controllability and voltage stabilization as well as short settling time (Kd is very small, if used) (7) Minimize the index J under a number of sequenced wind and load excursions over a selected settling time (1-2 times the largest time constant in the system) (8) Repeat the optimization guided procedure until delta error especially voltage is within maximum +- 10 % in a short settling period and max wind power is somewhat extracted also no severe oscillations in the dynamic response, damped or over-damped dynamic response.

Appendix A Models A.3 Controller Parameters The figure below showed J-Ki-Kp 3-phase-portait for Controller Parameter Searching Start End

Appendix A Models A.4 PWM Models Below is the Structure of PWM Model Referred to Matlab/Help

Appendix A Models A.4 PWM Models The PWM Generator block generates pulses for carrier-based pulse width modulation (PWM) systems. The block can be used to fire the self-commuted devices (FETs, GTOs, or IGBTs) of single-phase, two-phase, three-phase, or a combination of two three-phase bridges. The number of pulses generated by the PWM Generator block is determined by the number of bridge arms you have to control

Appendix A Models A.4 PWM Models The pulses are generated by comparing a triangular carrier waveform to a reference sinusoidal signal. The reference signal can be generated by the PWM generator itself, or it can be generated from a signal connected at the input of the block. In the second option, the PWM Generator needs one reference signal to generate the pulses for a single- or a two-arm bridge, or it needs a three-phase reference signal to generate the pulses for a three-phase bridge (single or double bridge The amplitude (modulation), phase, and frequency of the reference signals are set to control the output voltage (on the AC terminals) of the bridge connected to the PWM Generator block.

Appendix A Models A.4 PWM Models The following figure displays the two pulses generated by the PWM Generator block when programmed to control a one-arm bridge

Appendix A Models A.4 PWM Models The following figure displays the six pulses generated by the PWM Generator block when programmed to control a three-arm bridge.

Appendix A Models A.5 Diesel Engine Model The figure below is the Structure of the Diesel Engine

Appendix A Models A.5 Diesel Engine Model The diesel engine comprises diesel engine & governor and excitation system. The diesel engine & governor include the control system, actuator and diesel engine; it inputs desired and actual speed, output diesel engine mechanical power. The excitation system provides excitation for the synchronous machine and regulates its terminal voltage. The first input of the block is the desired value of the stator terminal voltage. The following two inputs are the vsq and vsd components of the terminal voltage. The fourth input can be used to provide additional stabilization of power system oscillations.

Publications: A.M. Sharaf, and Liang Zhao, “A Low Cost Dynamic Voltage Stabilization Scheme for Stand Alone Wind Induction Generator System”. ICCCP05 Oman (Accepted). A.M. Sharaf, Liang Zhao, “A Hybrid Power Compensation Scheme for Voltage Stabilization of Stand Alone Wind Induction Generator System”. CCECE05 (Accepted). A.M. Sharaf, and Liang Zhao, “A Universal Power Compensation (UPC) Scheme for Voltage Stabilization of Stand Alone Wind Induction Generator System”, 2005 IEEE Conference on Control Applications, August 28-31, 2005, Toronto, Canada. (Submitted) A.M. Sharaf, and Liang Zhao,“A Dual Switching Universal Power Compensation Scheme for Wind-Diesel Standalone Energy System”, 8th International Conference on ‘Electrical Power Quality and Utilization’, Sep 21-23, Cracow, Poland. (Submitted) A.M. Sharaf, and Liang Zhao, “Novel Control Strategies for Wind-Diesel Standalone Energy System Using Dual Switching Facts Universal Power Stabilization Scheme”, EPSR- Elsevier Jounal. (Submitted)

Prof. Dr. A. M. Sharaf Electrical and Computer Engineering Department Dynamic Filter Compensator Schemes for Monitoring and Damping Subsynchronous Resonance Oscillations Prof. Dr. A. M. Sharaf Electrical and Computer Engineering Department

Background review of SSR Modeling details for -Synchronous generators PRESENTATION OUTLINE Introduction Objectives Background review of SSR Modeling details for -Synchronous generators -Induction motors Sample dynamic simulation results Conclusions and future extensions

Example of SSR oscillations: SSR was first discussed in 1937 Introduction What is Subsynchronous Resonance (SSR)? Subsynchronous Frequency: Subsynchronous resonance is an electric power system condition where the electric network exchanges energy with a turbine generator at one or more of the natural frequencies of the combined electrical and mechanical system below the synchronous frequency of the system. Example of SSR oscillations: SSR was first discussed in 1937 Two shaft failures at Mohave Generating Station (Southern Nevada, 1970’s) Where: - Synchronous Frequency = 60 Hz - Electrical Frequency - Inductive Line Reactance - Capacitive Bank Reactance 1.Subsynchronous frequency and electrical resonance frequency are complementary. 2.During the last 30 years significant efforts have been devoted to the analysis of the phenomenon.

Objectives 1. Study Subsynchronous Resonance (SSR) oscillations for synchronous generators and large induction motors 2. Explore a new method to monitor SSR shaft torsional oscillations 3. Develop and validate a novel dynamic control scheme to damp SSR shaft torsional oscillations

Background Review of SSR SSR Torsional Modes Analysis -Mechanical System (inertia, shaft stiffness, etc.) -Electrical System Mechanical test shows that the natural torsional modes as a function of inertia and shaft stiffness. Torsional modes of frequency used in this study are between 11 and 45Hz. (typically 15.71Hz; 20.21Hz; 24.65Hz; 32.28Hz; 44.99Hz) Categories of SSR Interactions: 1.The natural frequencies of shaft torsional modes are frequencies of the shaft mechanical stresses. - with inertia increases, the mechanical resonance frequency of torsional modes decreases. - With shaft stiffness increases, the mechanical resonance frequency of torsional modes increases. 2. The subsynchronous currents produce shaft torques on the turbine generator rotor that cause the rotor to oscillate at subsynchronous frequencies. Torsional interaction Induction generator effect Shaft torque amplification Combined effect of torsional interaction and induction generator Self-excitation Torsional natural frequencies and mode shapes

Background Review of SSR Other sources for excitation of SSR oscillations Power System Stabilizer (PSS) HVDC Converter Static Var Compensator (SVC) Variable Speed Drive Converter 1. Besides the interaction between turbine-generators and series capacitor compensated networks. 2. In general, any devices which control or respond rapidly to power or speed variations in the subsynchronous frequency range is a potential source

Modeling for Synchronous Generator Sample Study System Figure 1. Sample Series Compensated Turbine-Generator and Infinite Bus System A spring mass model is used for the representation of the shaft system. 2. Mechanical system damping: rad/sec Figure 2. Turbine-Generator Shaft Model Table 1. Mechanical Data

Modeling for Synchronous Generator Figure 3. Matlab/Simulink Unified System Model for the Sample Turbine-Generator and Infinite Bus System

The Intelligent Shaft Monitor (ISM) Scheme 1. Figure 4. Proposed Intelligent Shaft Monitoring (ISM) Scheme

The Intelligent Shaft Monitor (ISM) Scheme - The result signal of (LPF, HPF, BPF) = 377 –Radians/Second T0 = 0.15 s, T1 = 0.1 s, T 2 = 0.1s, T3 = 0.02 s Band Pass filter: w1=w2=377 remove 60Hz Figure 5. Matlab Proposed Intelligent Shaft Monitoring (ISM) Scheme with Synthesized Special Indicator Signals ( )

The Dynamic Filter Compensator (DFC) Scheme -Shunt Modulated Power Filter -Series Capacitor -Fixed Capacitor 1. Figure 6. Facts Based Dynamic Filter Compensator Using Two GTO Switches S1, S2 Per Phase

Figure 8. DFC Device Using Synthesized Damping Signals ( ) Magnitudes Control System Design Figure 8. DFC Device Using Synthesized Damping Signals ( ) Magnitudes

Control System Design Figure 7. Dynamic Error Tracking Control Scheme for the DFC Compensator

Simulation Results for Synchronous Generator Figure 9. Monitoring Synthesized Signals without DFC Compensation Under Short Circuit Fault Condition

Simulation Results for Synchronous Generator Figure 10. SSR Oscillatory Dynamic Response without DFC Compensation Under Short Circuit Fault Condition

Simulation Results for Synchronous Generator Figure 11. Monitoring Synthesized Signals ( ) with DFC Compensation Under Short Circuit Fault Condition

Simulation Results for Synchronous Generator Figure 12. SSR Oscillatory Dynamic Response with DFC Compensation Under Short Circuit Fault Condition

Modeling Details for Induction Motor Figure 13. Induction Motor Unified System Model

The Dynamic Power Filter (DPF) Scheme Figure 14. Novel Dynamic Power Filter Scheme with MPF/SCC Stages

Figure 15. Tri-loop Dynamic Damping Controller Control System Design Figure 15. Tri-loop Dynamic Damping Controller

Control System Design Figure 16. Tri-loop Error-Driven Error-Scaled Dynamic Controller Using a Nonlinear Tansigmoid Activation Function

Control System Design Figure 17. Proposed Tansigmoid Error-Driven Error-Scaled Control Block

Synthesized Monitoring Signals Where: Figure 18. Voltage Transformed Synthetic Signals Figure 19. Current Transformed Synthetic Signals

Simulation Results for Induction Motor Without Damping DPF Device With Damping DPF Device Figure 20. Monitoring Signals P & Q Figure 21. Monitoring Signals P & Q

Simulation Results for Induction Motor Without Damping DPF Device With Damping DPF Device Figure 22. Shaft Torque Oscillatory Dynamic Response Figure 23. Load Power versus Current, Voltage Phase Portrait

Summery: Three Cases Comparison Figure 24. Monitoring Signals Without SSR Modes Figure 25. Monitoring Signals With SSR Modes But Without DPF Figure 26. Monitoring Signals With SSR Modes And With DPF

Summery: Three Cases Comparison Figure 27. Monitoring Signals Without SSR Modes Figure 28. Monitoring Signals With SSR Modes But Without DPF Figure 29. Monitoring Signals With SSR Modes And With DPF

Summery: Three Cases Comparison Figure 30. Shaft Torque and Speed Dynamic Response without SSR Modes Case 1 Figure 31. Shaft Torque and Speed Dynamic Response with SSR Modes But without DPF Case 2 Figure 32. Shaft Torque and Speed Dynamic Response with SSR Modes And with DPF Case 3

Summery: Three Cases Comparison Figure 33. Stator Current Fast Fourier Transform (FFT) without SSR Modes Case 1 Figure 34. Stator Current Fast Fourier Transform (FFT) with SSR Modes but without DPF Case 2 Figure 35. Stator Current Fast Fourier Transform (FFT) with SSR Modes and with DPF Case 3

Conclusions and Future Extensions For both synchronous generators and induction motor drives, the SSR shaft torsional oscillations can be monitored using the online Intelligent Shaft Monitor (ISM) scheme. The ISM monitor is based on the shape of these 2-d and 3-d phase portraits and polarity of synthesized signals The proposed Dynamic Power Filter (DPF) scheme is validated for SSR torsional modes damping Future work includes: Develop a Matlab based monitoring software environment- the Intelligent Shaft Monitor (ISM) system for commercialization Test a low power laboratory model of the prototype Dynamic Power Filter (DPF) and control scheme.

Publications [1] A.M. Sharaf; and Bo Yin; “Damping Subsynchronous Resonance Oscillations Using A Dynamic Switched Filter-Compensator Scheme,” International Conference on Renewable Energies and Power Quality (ICREPQ’04), Barcelona, March, 2004. [2] A.M. Sharaf; Bo Yin; and M. Hassan; “A Novel On-line Intelligent Shaft-Torsional Oscillation Monitor for Large Induction Motors and Synchronous Generators,” CCECE04, IEEE Toronto Conference, May, 2004. (Accepted)