Getting to Know the AAnalyst 200

Slides:



Advertisements
Similar presentations
1 Series V4T 1/4 DIN Temperature Controllers. 2 3 Watlows Next Generation Styling Series 97 Matching 1/16 DIN Limit Controller Series F4S and F4D Ramping.
Advertisements

PRODUCT PRESENTATION QUANTUM2. EVOLIS QUANTUM, MODULAR SYSTEM FOR CENTRALIZED CARD PRODUCTION.
Preferred Instruments CB-Hawk Replacement System Based on BurnerMate TS Technology A low-cost upgrade for obsolete CB-Hawk systems.
ASF Leak Detectors – New Design Präsentation neuer LAG Newsletter.ppt 1 After our previous device models are used for nearly four decades in more than.
Installation base of over 25,000 valued installations, Country wide Installation base of over 25,000 valued installations, Country wide Recognised as.
All purpose professional emergency lighting. Ceiling mounting. Beghelli Formula 65 is equipped with a symmetric reflector which makes it suitable for.
BurnerMate TS Overview
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
Atomic Absorption Spectrometer
ES Hwang Inorganic Product Specialist PerkinElmer Korea
CONFIDENTIAL. The Challenges Develop the next generation of value-oriented card printers Bring dual-sided card printing into the mainstream by making.
… for Combustible Gas Detection S4000C Intelligent Sensors..
Multi-Loop PID Controllers All Watlow® multi-loop time/temperature controllers offer auto-tuning which automatically sets PID control parameter for optimum.
The Importance of Combustion Testing Testo HVAC Distributor Training:
Dr C Narain Spantech Products, South Godstone, Surrey, UK The exclusive representative for ACD in Europe, Middle East and India.
ONYX RIP Version Technical Training General. Overview General Messaging and What’s New in X10 High Level Print and Cut & Profiling Overviews In Depth.
Sales Presentation Q Datamax Corporation Orlando, FL USA.
An Introduction to Flame Atomic Absorption Spectrometry (FAAS) Steve Badger and Charity Wessel.
LEAK-MASTER Welcome page No. 1 for gas safety equipment and gas control equipment Leak_master_praes_uk_30722.
(Use space bar to step through presentation)
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
MET ONE 7000 Series Remote Airborne Particle Counters Customer Name Date Presenter Presenter Title.
S8910U1000 Universal Electronic Ignition Modules Training Module
April 2004 page 1 Confidential and propietary CentraLine Portfolio c l o s e t o y o u.
1. LEARN CONNECT & GET SUPPORT GENERATE LEADS START Marketing Community Marketing Services Bureau Microsoft Dynamics Marketplace Demand Generation Campaigns.
Fluorescence. Topics Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-Induced Fluorescence.
Atomic Absorption Spectroscopy (AAS)
ATOMIC ABSORPTION AND ATOMIC FLUORESCENCE SPECTROMETRY Chap 9.
Fluorescence. Topics Definition Instrumentation Sensitivity (nM-pM) –Contrast UV-vis measurements Derivatization Laser-induced Fluorescence.
Atomic Absorption Spectroscopy Elemental analysis Dissolved metals Source –Hallow Cathode Lamp –Cathode of specific element Sample –Acetylene-air flame,
BC ILN Atomic Absorption Spectroscopy (AAS) 1 Thompson Rivers University.
Presented to: Name of Customer Enhanced MET ONE 3400 Series Portable Airborne Particle Counters.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
Instrumentation Developments in Stream Switch Valve Technology Steve Doe, Parker Hannifin Corporation.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
OmniView® Single Rail Rack Console with KVM. 31/03/20082 OmniView® Single Rail Rack Console with KVM Control your servers from a compact 1U rack-mount.
Atomic Emission Spectrometry
What’s New?. 2 Introducing the new What’s New? Compact industrial-strength barcode label & RFID printers  The best performance & features for the price.
High Sensitivity Smoke Detection
Your analytical partner ! Company Introduction Company Profile: Experience Customers Products: Reducing Compound Photometer Flame Ionization Detector Span.
NAVIGATOR™ Portable Balances
TL70 The Choice is Yours: You choose how to order and build the TL70 with the flexibility to customize the tower light as needed and change positions in.
MX6 iBrid Multi-Gas Monitor
EZPump tm SSI Pump Control for EZChrom SI tm And EZChrom Elite tm.
Sales Objections and FAQ’s 940-LC Analytical to Preparative Systems.
Introduction to Design Engineer Analysis
Introduction to training
The MINIKO High Precision Semi-automatic SMT Stencil Printer.
Atomic-absorption spectroscopy
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
2015 NetSymm Overview NETSYMM OVERVIEW December
A TOMIC - ABSORPTION SPECTROSCOPY Lab no. 3 Done by : Iman Al Ajeyan.
The New Switch can replace all the Old Room Needed Controllers 1– Light Switches and Wall Dimmers 2– Air-conditioning Thermostat 3– Volume Control 4–
emerald™ New Product Announcement November 2012.
BurnerMate TS Overview. PREFERRED UTILITIES MFG CORP South St. Danbury CT T: (203) F: (203) www. PREFERRED-MFG.com.
PRODUCT PRESENTATI ON COLOR TOUCH SCREEN DISPLAY.
Overview Of Autoflame. Schedule Overview of Autoflame products – MM Controls: Mk8 & Mini Mk8 – Exhaust Gas Analyser (EGA) – Data Transfer Interface (DTI)
Atomic Absorption Spectrometer
A New autodata Comprehensive | Innovative | Business focussed
C1300 advanced circular chart recorder
LIAISON®: Instrument Overview
Introducing the Bradford White ICON System™ and Accessory Packages
Installing the HP LaserJet Pro 500 color MFP M570 printer software in Windows on a Wireless Network & Wired Network.
Focus HT Product overview July 2017.
Introduction: New Compact Display Panel SimpleTouch
AQT90 FLEX – the product 28/11/2018.
Diagnostics Analytical 920 LC Semi-Prep 940 LC
High Accuracy UV-VIS Spectroradiometer ( nm)
OL 750 Spectroradiometer & Linear Spectral Transmission Measurements
Presentation transcript:

Getting to Know the AAnalyst 200 Chuck Schneider

The AA business strategy Redefine the low-end AA marketplace Develop a next generation platform Create a strong desire among customers to replace their existing AA Make modern technology available at a lower price point Build momentum and penetration into new market areas

AAnalyst 200—A Better way to do AA The AAnalyst 200 offers our customers a better way to do Flame AA. The AAnalyst 200 provides a no compromise approach to Atomic Absorption—from sample introduction to results

What is the AAnalyst 200? What it is not… It is not a cheap single-beam AA It is not a low-performance system designed only for new markets It is most definitely not another version of the 3100/3300/3110/100/300

Well, then what is the AAnalyst 200 The first of a new generation of AA instruments: Intuitive touch screen interface Eight different languages to choose from New burner system design New nebulizer An entirely new approach to servicing an instrument New Echelle optical system with solid state detector

Expect More from your AA The AAnalyst 200 offers… … our customers a better way to do Flame AA. The AAnalyst 200 provides a no compromise approach to Atomic Absorption—from sample introduction to results. By providing the features and benefits found in top-of-the-line AA instruments without the price tag.

Well, then what is the AAnalyst 200 The first of a new generation of AA instruments: Intuitive touch screen interface

The AAnalyst 200 Touch Screen Interface Large 9-inch, full-color LCD display Rugged design tested to over one million touches Resistant coating makes it safe for lab use Similar to WinLab32, reducing their learning curve when they purchase an ICP or high-end AA from PKI

Touch Screen Interface-Lamp Page Lumina lamps recognized for automatic setup of wavelength, slit and flame type On-line cookbook conditions for all flame elements Built-in EDL power supply on mid- level and premium configurations

Touch Screen Interface-Flame Page Fully automated gas box ensures easy setup and safety Selection of flame type, fuel/oxidant flows Continuous readout of absorbance for easy setup of burner system Toggle switch for on/off of flame

Touch Screen Interface-Flame Page Eight safety interlocks ensure safe operation Automatic switchover from air-acetylene to nitrous oxide Flows stored with method Emergency off switch similar to ICP for increased safety

Touch Screen Interface-Parameters Page Selection of integration times, replicates and read delay Decide what to print and manual or automated analysis Second page is to setup calibration parameters

Touch Screen Interface-Analyze Samples Manual or automated analysis Supports AS-90 plus and AS-93 plus autosamplers Print results to DeskJet or LaserJet Display and print calibration curve

Touch Screen Interface-Tools Page Tools page supports remaining user functionality Select method, save method and new method are used to store methods Options allows user to select autosampler, language, and printer On-line cookbook for all elements Service diagnostics built-in

Well, then what is the AAnalyst 200 Support for eight different languages GUI is fully translated in German, Italian, French, Spanish, Japanese, Russian, Chinese and English Manual is also available in eight languages

Touch Screen Interface-Eight Languages

Well, then what is the AAnalyst 200 The first of a new generation of AA instruments: New burner system design New nebulizer

Quick-lock Burner System Improved design from proven AAnalyst 100/300 Burner head with automatic recognition Reliable igniter system Rugged corrosion resistant spray chamber design Quick-lock design makes removal easy

New corrosion resistant nebulizer design High Sensitivity design One design for both air-acetylene and nitrous oxide Uses ceramic impact bead Sample tubing connected via a screw fitting for easy replacement

Well, then what is the AAnalyst 200 The first of a new generation of AA instruments: An entirely new approach to servicing an instrument

AA 200—Designed to be customer serviced All electronics are in the e-box Customer can replace Customer can keep spare for no downtime Service engineer can troubleshoot much quicker Touch screen can also be replaced Dramatically reduced cost of ownership

AA 200—Designed to be customer installed Customer self-installation available in some areas Installation/Trouble-shooting CD helps customer install/repair intstrument Verification kit ensures that instrument is performing properly Dramatically reduced cost of ownership

Well, then what is the AAnalyst 200 The first of a new generation of AA instruments: New Echelle optical system with solid state detector Modern Technical Advantages at a Lower Price

First True Double-beam Echelle in an AA

The First of a New Generation of AAnalysts AAnalyst 200-Three configurations All configurations have touch screen, double-beam optics, user serviceable electronics, multi-language support Base Configuration: Single lamp, no D2, no EDL support Mid-Level Configuration: Single lamp, D2, support for one EDL, Ethernet connection Premium Configuration: Four lamp turret, D2, dual EDL support, Ethernet connection Optional Accessories AS-9X and MHS-15

Coming Soon….Upgradeablity WinLab32 Control Graphite Furnace But not until later this year!! Including initial units

AAnalyst 200 Features—A Better Way… Touch Screen  Incredible Ease of Use Quick-lock Burner Assembly Easy to remove system for maintenance New nebulizer  Corrosion resistant high sensitivity design E-box  Easy customer service Echelle Monochromator  High light throughput Solid State Detector  No PMT to replace Compact Design  Saves laboratory space Verification Kit  Increases customer confidence of self-installation Purged Optics  Increased reliability in corrosive environments