4: From x-ray to image – Computed Tomography

Slides:



Advertisements
Similar presentations
PRINCIPLES OF CT.
Advertisements

IMAGE GENERATION IN CT.
Principles of CT.
Fund BioImag : Interaction of ionizing radiation with matter 1.What is the basis of contrast for x-ray imaging ? 2.By which mechanisms does ionizing.
Computed Tomography Principles
Fund BioImag : Echo formation and spatial encoding 1.What makes the magnetic resonance signal spatially dependent ? 2.How is the position of.
Fund BioImag : Emission (Computed) Tomography 1.What is a tracer ? 2.Why is collimation necessary and what are its consequences ? 3.How are the.
X Rays Medical Physics Notes.
CT Scanning: Dosimetry and Artefacts
Wilhelm Conrad Röntgen
Computers and Computed Tomography
Image Reconstruction.
Fund BioImag : Echo formation and spatial encoding 1.What makes the magnetic resonance signal spatially dependent ? 2.How is the position of.
6: Positron Emission Tomography
Improved Conspicuity of Abdominal Lesions with Single-Source Dual-Energy MDCT Hadassah Hebrew University Medical Center Jerusalem, Israel Ruth Eliahou.
Wednesday night and Thursday Lab Mega Group.  1967: The first Computer Tomography (CT) theory was developed  1972: The CT scan was invented by Godfrey.
Computed Tomography
Fund BioImag : MRI contrast mechanisms 1.What is the mechanism of T 2 * weighted MRI ? BOLD fMRI 2.How are spin echoes generated ? 3.What are.
Mark Mirotznik, Ph.D. Associate Professor The University of Delaware
Fund BioImag : From x-ray to image – Computed Tomography 1.What factors influence contrast in x-ray imaging ? Beam hardening Sensitivity and.
Advanced Biomedical Imaging Dr. Azza Helal A. Prof. of Medical Physics Faculty of Medicine Alexandria University Lecture 6 Basic physical principles of.
Computed Tomography II
SCANCOMEDICAL Computed Tomography SCANCO User Meeting 2005 Dr. Bruno Koller SCANCO Medical AG
IPIM, IST, José Bioucas, X-Ray Computed Tomography Radon Transform Fourier Slice Theorem Backprojection Operator Filtered Backprojection (FBP) Algorithm.
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
CT Physics V.G.Wimalasena Principal School of radiography.
Computed Tomography III
BME 560 Medical Imaging: X-ray, CT, and Nuclear Methods
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
Computed Tomography RAD309
tomos = slice, graphein = to write
Lean Body Mass Assessment: Interpretations of Computed Tomography
Application of Digital Signal Processing in Computed tomography (CT)
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
…….CT Physics - Continued V.G.WimalasenaPrincipal School of radiography.
LEC ( 2 ) RAD 323. Reconstruction techniques dates back to (1917), when scientist (Radon) developed mathematical solutions to the problem of reconstructing.
COMPUTED TOMOGRAPHY (I) RAD 365 CT - Scan
Basic principles Geometry and historical development
5.4.1 X-Rays. (a) describe the nature of X-rays Stowmarket Physics X-rays - nature Forms of electromagnetic radiation Short wavelength High frequency.
COMPUTED TOMOGRAPHY I – RAD 365 CT - Scan
Radiation therapy is based on the exposure of malign tumor cells to significant but well localized doses of radiation to destroy the tumor cells. The.
Without reference, identify principles relating to Computed Tomography Clinical Applications with at least 70 percent accuracy.
Alhanouf Alshedi CT Physics and Instrumentation RAD
CT “Computer tomography”. Contrast mechanisms in X-ray imaging: X-ray absorption X-ray absorption mechanisms: 1. Photoelectric effect 2. Compton scatter.
X-Ray Medical Imaging Physics – IB Objectives
Medical Image Analysis Medical Imaging Modalities: X-Ray Imaging Figures come from the textbook: Medical Image Analysis, Second Edition, by Atam P. Dhawan,
Computed Tomography Physics, Instrumentation, and Imaging
A-LEVEL PHYSICS 15/09/ :49 Medical Physics.
Resident Physics Lectures
MIPR Lecture 7 Copyright Oleh Tretiak, Medical Imaging and Pattern Recognition Lecture 7 Computed Tomography Oleh Tretiak.
Computed Tomography Q & A
PRINCIPLE AND BASIC PHYSICS OF COMPUTED TOMOGRAPHY
Computed Tomography References The Essential Physics of Medical Imaging 2 nd ed n. Bushberg J.T. et.al Computed Tomography 2 nd ed n : Seeram Physics of.
X - RAYS IN DIAGNOSTICS D. Krilov
Factors affecting CT image RAD
Interaction ionizing radiation with biological tissue. Basic dosimetry.
Computed Tomography Diego Dreossi Silvia Pani University of Trieste and INFN, Trieste section.
The production of X-Rays X-Rays are produced whenever charged particles are slowed down or stopped. X-rays are generated via interactions of the accelerated.
Part No...., Module No....Lesson No
Chapter-4 Single-Photon emission computed tomography (SPECT)
Introduction to Medical Imaging Week 3: Introduction to Medical Imaging Week 3: CT – Reconstruction and uses Guy Gilboa Course
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Introduction to Medical Imaging Week 2: X-ray and CT
Computed Tomography Basics
Resident Physics Lectures (Year 1)
X Rays Medical Physics Notes.
Basic principles Geometry and historical development
Computed Tomography (CT)
Resident Physics Lectures (Year 1)
Computed Tomography (C.T)
Presentation transcript:

4: From x-ray to image – Computed Tomography What factors influence contrast in x-ray imaging ? Beam hardening Sensitivity and resolution considerations What is the fundamental basis for image reconstruction using x-ray absorption ? Radon Transform How can x-ray images be reconstructed? Sinogram Backprojection vs. filtered backprojection Central Slice Theorem Examples After this course you Understand the consequences of the Bremsstrahlung continuum on image contrast Understand how Compton scattering reduces image contrast and how its influence can be reduced Are familiar with the Radon transform Understand the principle of matrix reconstruction and backprojection Understand the major mechanisms leading to CT contrast Fund BioImag 2013

Computed Tomography invented 1971 Primitive pancreatic lesion (neoplastic) Godfrey Hounsfield Allan Cormack Nobel prize 1979 engineer First clinical CT- 1972 physicist Fund BioImag 2013 Physiology and Medicine

CT of animal models transgenic mice and cancer models kidneys with IV contrast rat spine micro-CT scanner abdomen heart and lungs full body skeleton microCT (~50 µm spatial resolution) Mouse: blood vessels (red) Fund BioImag 2013

4-1. What does absorption in the real world imply 4-1. What does absorption in the real world imply ? Linear attenuation coefficient m n n-dn Contrast is “well-defined” for monochromatic x-rays But, µ=f(En,Z, r) μ : linear attenuation coefficient Unit: [cm-1] The measurement that is wanted: m(x,y) What is measured: n(x) dx If µ is constant in x Two consequences: Beam hardening Depth dependent contrast Fund BioImag 2013 (m for a homogeneous object of thickness x)

What does the Energy Spectrum of an x-ray tube really look like What does the Energy Spectrum of an x-ray tube really look like ? filtered Bremsstrahlung and characteristic emission i(En): complex function i(En) Eeff Interaction with orbital electrons Define effective photon energy Eeff Bremsstrahlung continuum Soft x-rays (low energy) Hard x-rays (high energy) Maximal x-ray energy is = kinetic energy of e- (eVcathode) Eeff is increased by instrument (filtering of soft x-rays) Minimal energy is zero, but: Soft x-rays (low energy) are filtered by instrument Fund BioImag 2013

What is the consequence of energy-dependent absorption What is the consequence of energy-dependent absorption ? Beam Hardening - Effective energy depends on depth A similar consequence arises in tissue: Ideal: Monochromatic x-rays (En(l) = d(l0)) Reality: Polychromatic, multienergetic i(En) Absorption is not uniform with En Contrast changes with large objects and depth Excessive radiation dose to superficial tissue “Solution”: Reduce i(En) for soft x-rays (e.g. 3mm Al eliminates 90% of 20keV photons) Fund BioImag 2013

How does x-ray scattering impact CNR ? Scattering increases with FOV (field-of-view) of irradiation  Further reduction of image contrast Solution: Anti-scatter grid (collimator) Object (lesion) Photoelectric effect: complete absorption of photons → Object (lesion) easily detected With En ↑: Compton scattering → increased masking of object. High Z, r: stop x-rays Collimation principle: establishes directionality of x-rays Slice selection Detector Fund BioImag 2013

How is CNR quantified ? Signal:  I(d) (no. photons detected)  I0 (no. photons irradiated) Contrast: DI(d) due to µ(d) differences i(En), mC produces reduced contrast Compton scattering: Antiscatter grid CT intensity can be measured in absolute terms (CT-number) Soft tissue: Typically has weak contrast (small Hounsfield units) HU : attenuation normalized to water (0) range from -1000 (air) to +3000 (bone and contrast agents) soft tissues: -300 to +100 Fund BioImag 2013

4-2. What is the basis of image reconstruction ? The Radon transform Dy Dy … Considering a two-dimensional objet: Given a certain beam intensity (no. of photons) I at a given position y, I(y0), the beam intensity at y+Dy is Recursive application to derive I(y0+2Dy) I(y) I0 I0: intensity of incident x-ray beam x y0 y Radon transform g(x) Definition Radon transform of a point-like homogeneous object rectangular object lim Dy→0 Fund BioImag 2013 g(x)

Does each pixel have a unique trajectory ? Sinogram Radon transform of a circular object f Radon transform = projection of object Trajectory: Rsin(f+f0) Each point in space is uniquely represented by Amplitude R and phase f0 of sinusoidal trajectory in Sinogram (sic!): (x,y) → (R,f0) Detector: is moved in circular motion around object (indicated by angular position f) Fund BioImag 2013

Can a CT image be constructed by Matrix inversion ? Decomposing an object into a 2x2 matrix requires a minimum of 4 measurements: ln(I1/I0) = -m1Dx-m2 Dx ln(I2/I0) = -m3Dx-m4 Dx ln(I3/I0) = -m1Dy-m3 Dy ln(I4/I0) = -m2Dy-m4 Dy Setting Dx=Dy yields a linear 2x2 inversion problem linking mk to Ik In principle such an n2 matrix can be inverted.  Too complex, computationally intensive and unstable CT was introduced in 1970  simple reconstruction algorithm! Fund BioImag 2013

180 backprojections: reconstruction is complete. 4-3. What algorithm is adapted to 1970’s computing power ? Backprojection reconstruction Basic reconstruction principle: Along the measured projection direction fill in each pixel constant numbers corresponding to the Radon transform (projection intensity). Repeat for next orientation of the projection, sum the values in overlapping pixels. Illustration with gray shades (point-like object): 1 1 1 1 1 1 1 1 2 x’ y’ 4 Projections 2 Projections 180 backprojections: reconstruction is complete. 1st 60 Projections the next 60 8 Projections 16 Projections Fund BioImag 2013

Why does simple Backprojection have poor spatial resolution ? Backprojection has poor spatial resolution: Solution ? Reconstruction of a point-object falls of with 1/r WHY? The reconstruction falls off with 1/r (in analogy to the decrease of light intensity in 2D) dxdy=dA=rsin(df)drrdfdr df dA  r Number of rays (projections): constant with df rdf df But: pixel size = dxdy  dA = const  No. of rays  1/r r dr Fund BioImag 2013

How can good image resolution be maintained ? Filtered Backprojection Fund BioImag 2013 Example: Reconstruction of a slice from projections

How is Backprojection linked to Fourier transform How is Backprojection linked to Fourier transform ? Central Slice Theorem Image space x y Final Image (CT: acquired data) kx=0 FT FT of projection → 1 line in k-space IFT  Reconstruction using FT : k-space (Fourier space) kx ky MRI: Acquired Data artifacts Fund BioImag 2013 See also: Signals and Systems (SV)

X-ray CT : Examples (Human) Bone (calcification) : bright (high absorption) Imaging of mummified bodies Different densities of tissue give inter-mediate results Air is dark Dislodged arrow head Fund BioImag 2013

CT: Examples (mouse) Pre- Post-contrast 3D CT scan of rodent spine treated with human mesenchymal stem cells (transduced with the human BMP-9 gene via an adenoviral vector) significant bone formation at the treatment sites (arrows) 13µm micro CT of mouse placenta vasculature Micro-CT of mouse femor bone Fund BioImag 2013

Insect with iodine contrast agent CT: Summary Main contrast is bone vs. soft tissue (or air) (calcium content i.e. e- density r) Contrast agents (increase Zeff) allow depiction of vessel architecture and lesions SNR and CNR: Intensity can be increased by cathode current High spatial resolution possible (limited only by radiation dose in humans) Fish larvae Fund BioImag 2013 Insect with iodine contrast agent

How have CT scanners evolved ? Generations of CT scanners First Generation Parallel beam design One/two detectors Translation/rotation 2nd Generation Small fan beam Larger no. of detectors 3rd Generation Multiple detectors Large fan beam 4th Generation Detector ring Fund BioImag 2013