Arrow Valves Ltd – The Water Regulations Solution Specialist

Slides:



Advertisements
Similar presentations
“The Major Breakthrough In Hard Water Treatment Technology”
Advertisements

Arrow Valves Ltd – The Water Regulations Solution Specialist
Let’s watch a DVD… DVD Instructor Notes
Fired And Unfired Pressure Vessels
HOT & COLD WATER SYSTEMS
International Mechanical Codes Scald Protection. – Where a combination potable water-heating and space-heating system requires water for space.
Primarily Focusing on Backflow Prevention
Cross-Connections Gary Carlson Drinking Water Program U.S. EPA Region 8.
Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Customer Service – International Dept. The thermal solar systems  Installation  Commissioning  Maintenance.
Buildings and Structures 2 Fixed Installations Aim To provide students with information to allow them to recognise the types of fixed fire protection.
Unit 206: Domestic hot water systems
Unit 205: Cold water systems
UL/FM Fire Pump Systems Lunch & Learn 04/18/05
September 29-30, 2011 Drinking Water Program Sustained Compliance Workshop Lee Johnson, P.E
Potential Pathways for Coliform Contamination. Fixing Positive Coliform Results.
Chemigation. Chemigation Chemigation is the process of applying pesticides and fertilizer through irrigation waterChemigation is the process of applying.
Unit 206: Domestic hot water systems
Garry Boorman Principal Advisor, Public Health & Standards
DMK Mechanical Services Ltd Pipework Solutions… Service Excellence.
Unit 205: Cold water systems
Unit 206: Domestic hot water systems
Unit 205: Cold water systems
Unit 206: Domestic hot water systems
Lesson One.
Direct Cross-Connection (a) A Clean-In-Place system is used to direct sanitizer from a reservoir to a recently cleaned milk tank. The sanitizer exists.
Water Regulations for Allotment Users 1999 onwards.
Backflow Prevention.
Pharmaceutical Water Systems Alain Kupferman Manufacture of sterile medicines – Advanced workshop for SFDA GMP inspectors, Nanjing, November 2009.
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
Hydronic Mechanical Controls
Safe Facilities and Equipment
1-1. Key Sanitation condition No. 1:  Safe supply for water that contacts food and food contact surfaces;  Safe water supply for production of ice; and.
ASSE 1016, 1069 & Automatic Compensating Valves for Individual Showers and Tub/Shower Combinations  Intended for wall-mounted showers and tub/showers.
Domestic Natural Gas Installations Marc Billington.
HVAC523 Circulator Pumps.
5.1.? Student Book © 2005 Propane Education & Research CouncilPage 1 Selecting the pump for a propane dispenser should include a complete understanding.
© 2009 Michigan State University licensed under CC-BY-SA, original at Water Quality.
Trade of Plumbing – Phase 2 Module 2 – Unit 9 Module 2: Domestic Hot and Cold Water Services Unit 9 – Valves and Taps Duration – 11 Hours.
CHAPTER 12 Copyright © 2007 Thomson Delmar Learning 12.1 Protective Systems.
Specification & Installation pitfalls “Getting it right to ensure safe drinking water”
1 CXS490 - Pre-Engineered Fire Protection Systems Off-Road Vehicle Systems.
To complete installation on electronic models run one wash cycle then click the DIP switch setting no.4 to the on position DIP switch settings.
Launch Chameleon Plus P - More Preventive features and safety L - More Longer Lasting and robust U - More User friendly operation S - More Service friendly.
Lab design Assignment 3 Unit 2.
Water Recycling. Why? Do you think water should be recycled? Why? How do you think water is recycled?
Regulations 1999 Water Supply (Water Fittings) With an Introduction to Utility Applications.
Unit 209: Drainage systems
Testing Requirements in the Boiler House Requirements for regular testing will vary according to national regulations, and the type of equipment installed.
Unit 209: Drainage systems
“Beyond the loop layout”.  Jeremy Neven, C.B.C.O. ◦ Chief Building Official ◦ Plumber ◦ HVAC Designer ◦
Hot and Cold Water Supplies
CROSS CONNECTION CONTROL PROGRAM
Design, Evaluation and Application of a Fuel Cell Vehicle
Plumbing system fundamental and design course
Workshop developed by RCAP/AWWA and funded by the USEPA
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Heating Ventilation and Air Conditioning
Borbotech BV • Tel.: +31(0) • •
Electrical Gas Plumbing Heating & Cooling
PLUMBING APPLIANCES & COMPONENTS
Private Fire Hydrant. Fire hydrant systems (also known as fire pumps, hydrant boosters, fire water pumps) are high pressure water pumps designed to increase.
Hot water Systems Heaters.
Hot Water Systems Cylinders and Systems.
Cisterns and Insulation
Heating Ventilation and Air Conditioning
Backflow Devices 5 Types.
Primarily Focusing on Backflow Prevention
Presentation transcript:

Arrow Valves Ltd – The Water Regulations Solution Specialist July 2007 Arrow Valves Ltd – The Water Regulations Solution Specialist BACKFLOW www.arrowvalves.co.uk copyright 2006-2013

www.arrowvalves.co.uk copyright 2006-2012 What is Backflow? July 2007 “Backflow” means flow upstream, that is in a direction contrary to the intended normal direction of flow, within or from a water fitting Flow of water Backflow Back Siphonage Vacuum on supply Back Pressure Downstream pressure higher than supply www.arrowvalves.co.uk copyright 2006-2012

The above diagram shows a bath with a submerged shower head Backflow Example July 2007 Double Check Valve model ED235 Shower head Bath (1st floor) Sink (ground floor) The above diagram shows a bath with a submerged shower head If negative pressure should occur, dirty bath water could be sucked back into the pipework and be discharged from the sink as water used for hand washing, drinking etc Further (secondary) backflow protection should also be provided (see later slide) A Double Check Valve fitted to the shower hose would prevent the bath water reaching the sink and contaminating it www.arrowvalves.co.uk copyright 2006-2012

Fluid Categories Previous UK Classification July 2007 Previous UK Classification European/New UK Classification Backflow Prevention Examples (Used in Building Services) Class 1 Schedule A Risk European Fluid Category 5 Air Gap – AA AB Pipe Interrupter - DC European Fluid Category 4 RPZ – BA Pipe Interrupter - DB Class 2 Schedule B Risk European Fluid Category 3 Double Check – ED Class 3 Schedule C Risk European Fluid Category 2 Single Check – EB Wholesome Water European Fluid Category 1 No Protection Required (Except Secondary, at times) www.arrowvalves.co.uk copyright 2006-2012

Types of Backflow Protection Point of Use Protection July 2007 “The provision of zone or whole site backflow protection should be in addition to individual requirements at points of use and within the system” G15.25 Appliances of different types e.g. a washing machine and dishwasher, must have their own protection, preventing cross contamination www.arrowvalves.co.uk copyright 2006-2012

Types of Backflow Protection Zone Protection July 2007 “Any taps and fittings used for supplying water for non-domestic applications, such as commercial, horticultural, agricultural or industrial purposes should be provided with a. backflow protection devices appropriate to the downstream fluid category; and b. where appropriate, a zone protection system” G15.18 Where several appliances of the same type and same Fluid Category are used within a commercial building, water suppliers may accept single protection for multiple appliances. www.arrowvalves.co.uk copyright 2006-2012

Types of Backflow Protection Secondary Backflow Protection July 2007 “A whole-site or zone backflow prevention device should be provided on the supply or distributing pipe, such as a single check valve or double check valve, or other no less effective backflow prevention device, according to the level of risk as judged by the Water Undertaker…” G15.24 Whole site backflow protection should be provided on supply pipes to two or more separately occupied premises Arrow Valves Branch Valve model BRV – Servicing, Double Check & Drain Tap with Solder Union connections www.arrowvalves.co.uk copyright 2006-2012

Fluid Category 3 Protection Double Check Valve July 2007 ED Double Check Valve Category 3 protection ED is “non-verifiable” meaning there are no test points provided. EC is verifiable but none is approved and since protection is still Fluid Category 3, there is no benefit. Exceptionally low head-loss ED Device (Model ED132) Double Check Valve - model ED235. For fluid category 3 protection on shower hoses. Flow limiter option No Tools Required Applications – Supply to flats (whole site) Separate floors (secondary) Stainless Steel - exceptionally low head-loss – Model ED316 Numerous others www.arrowvalves.co.uk copyright 2006-2012

Filling Heating Systems July 2007 Fluid Category 3 (heating permanent connection) “Autofill” – Fluid Category 4 Model AFS Filling Valve – CA Device with Pressure Reducing Valve and inlet/outlet servicing valves Model CA297PRV Fluid Category 4 “Autofill” – Fluid Category 3 Model AFCA Optional wall mounting brackets (Model AFBRA) Automatically fill “house” heating systems or “non-house” heating systems less than 45 kW output Fills and pressurises “non-house” heating systems with output greater than 45 kW Accessories available include Expansion Vessels (EVCP), Expansion Vessel Isolators (BVEV) and Air Dirt Removers (ADR), Water Meter (WMV3P) www.arrowvalves.co.uk copyright 2006-2012

Filling Heating Systems – Fluid Category 5 July 2007 Features – “Midi-Fill” Digital Model MFD All the features of the “Midi-Fill” Digital plus – Low chemical BMS warning Manual internal dosing facility External dosing facility – replaces need for dosing pot Advanced Pressurisation Unit “Midi-Fill” Digital with Automatic Dosing Features – Weekly self test – BMS alerts to avoid heating system shutdown Anti-seize daily pump pulse Integral water meter and excessive filling alarms No annual testing Dose & Fill – Model DF www.arrowvalves.co.uk copyright 2006-2012

Fluid Category 4 Protection RPZ Valve / BA Device July 2007 Applications Clothes washing machines Dishwashing machines Fire fighting equipment Printing and photographic equipment Water treatment Water softening Vehicle washing and many more RPZ Option B Upstream Isolating Valve, Strainer, RPZ, downstream Isolating Valve Compact RPZ Valve Model BA3T Reduced Pressure Zone (RPZ) Valves – also known as BA device. Mechanical backflow preventer for Fluid Category 4 backpressure and backsiphonage protection Installation requirements Access height 0.3 m min 1.5 m max Adequate rear clearance Tamperproof environment Standpipe Freestanding watering point incorporating BA device Model SPBA www.arrowvalves.co.uk copyright 2006-2012

Fluid Category 4 Protection AF Air Gap July 2007 Based on diagram G15.31.2 SgV Outlet Air Gap Primarily to boost the supply pressure to Penthouse Suites and similar tall buildings requiring individual booster sets Applications Tall buildings (3 storey+) e.g. Penthouse suites Boosting low pressure “Combi” boilers and showers Drinking (“wholesome”) water – use optional jacket OPTIONS: Insulation Jacket Model BTJAC Wall Cover Model BTCAB3 Drip Tray Model BTDT1 “Pent-A-Boost” Fixed speed Compact Domestic Booster model BTAF Incorporating type AF air gap Variable speed also available Shown with optional insulation jacket Wall mounting brackets Model BTBRA Supplied as a complete package ready for installation www.arrowvalves.co.uk copyright 2006-2012

Fluid Category 5 Protection AB Air Gap July 2007 Based on diagram G15.31.2 SgV Outlet Air Gap Weir Overflow Primarily to provide Fluid Category 5 backflow protection and to boost water pressure for high flow applications Applications Non-domestic Hose Union taps e.g. Waste bin washing Wash-down Irrigation Laboratories Rain water Baths / Showers – Healthcare Bed pan washers OPTIONS: “Boost-A-Break” Fixed speed Break Tank and Booster Set model BTAB Incorporating type AB air gap Variable speed also available Suitable for all backflow prevention applications Wall Cover Model BTCAB3 Floor cabinet Model BTCAB1 Drip Tray Model BTDT1 Wall mounting brackets Model BTBRA www.arrowvalves.co.uk copyright 2006-2012

Fluid Category 5 Protection Wall mounted Break Tank & Booster Set AB Air Gap July 2007 Wall mounted Break Tank & Booster Set Primarily to provide Fluid Category 5 backflow protection and to boost water pressure for high flow applications Three models – Midi-1, Midi-2A and Midi-3A BTCAB4 - Wall Cover for “Midi-Break” Wall mounting brackets included Applications –  Healthcare premises (baths with shower hoses, clothes and dishwashing machines)  Bidet washing  Sinks with hoses  Non-domestic Hose Union taps  Vegetable washing “Midi-Break” Break Tank & Booster Set model BTMIDI Incorporating type AB air gap Stainless steel housing provides neat and hygienic installation BTDT3 - Stainless steel drip tray for “Midi-Break” www.arrowvalves.co.uk copyright 2006-2012

Fluid Category 5 Protection Care Shower July 2007 Supplies instantaneous hot water to an accurate maximum temperature Fluid Category 5 backflow protection Meets BEAB Care Mark Requirements as safe for use by elderly, young or sick Applications –  Healthcare (assisted bathing)  Nursing homes  Veterinary  Dog grooming  Medical  Mortuary  Butchery  Bidet  Toilet (paperless) Thermostatically controlled shower – Electric Shower & Booster Pump package (model CSABATLF) www.arrowvalves.co.uk copyright 2006-2012

Fluid Category 5 Protection Ablution Plant Ablution Plant – FC5 July 2007 Fluid Category 5 backflow protection Consists of - • Break Tank with Type AB air gap • Booster Pump • Storage Heater • TMV Assists with multi-cultural facilities Applications – Toiletry (paperless), animal washing, butchery Safe hot water with Fluid Category 5 backflow protection – Model BTHW www.arrowvalves.co.uk copyright 2006-2012

www.arrowvalves.co.uk copyright 2006-2012 July 2007 THE END For further guidance or to discuss your particular application, please contact us:  01442 823123  info@arrowvalves.co.uk www.arrowvalves.co.uk copyright 2006-2012