Patient–ventilator interaction

Slides:



Advertisements
Similar presentations
Patient – Ventilator Asynchrony
Advertisements

CPAP/PSV.
Pressure support ventilation Dr Vincent Ioos Pulmonologist and Intensivist Medical ICU, PIMS 1st International Conference Pulmonology and Critical Care.
Physiology of the Respiratory System
Interpretation of Ventilator Graphics
Control of Respiration
Part 5 Control of Respiration
How a Breath is Delivered
Respiratory Physiology Part I
Effect of different cycling off criteria and positive end-expiratory pressure during pressure support ventilation in patients with chronic obstructive.
Section 4 Regulation of the Respiration.
BASICS OF WAVEFORM INTERPRETATION Michael Haines, MPH, RRT-NPS, AE-C
Mechanics of Breathing Overview 1. Inspiration 2. Expiration 3. Respiratory Volumes.
Ventilator Graphics Emeritus Professor Georgia State University
3 nd LECTURE VENTILATORS Part One. Ventilators One of the major life support systems. Ventilators take over the vital role of the respiratory muscles.
Mechanical Ventilation Graphical Assessment
Are You Optimizing Every Bilevel Breath? Jim Eddins, RRT.
 Understand the dual control concept  Understand the pressure regulation mechanism in PRVC  Demonstration of PRVC  Settings and adjustment with Servo.
Mechanical Ventilation
Introduction to Basic Waveforms
Mechanical Ventilator 2
Mechanical Ventilation
Mechanical Ventilator 1
Volume-Assured Pressure Support Ventilation (VAPSV)
Advanced Modes of Mechanical Ventilation
Basic Concepts in Adult Mechanical Ventilation
Management of Dyspnea in Severe Chronic Obstructive Pulmonary Disease
Patient-ventilator interaction: insight from waveforms
Neuronal demand.
Assessing the performance of the Whisperflow® continuous positive airway pressure generator: a bench study  G.W. Glover, S.J. Fletcher  British Journal.
Management of Dyspnea in Severe Chronic Obstructive Pulmonary Disease
Influence of anaesthesia and analgesia on the control of breathing
M. Garnier, C. Quesnel, J. -P. Fulgencio, M. Degrain, G. Carteaux, F
Relationship of inspiratory and expiratory times to upper airway resistance during pulsatile needle cricothyrotomy ventilation with generic delivery circuit 
M.J. Wood, E.S. Lin, J.P. Thompson  British Journal of Anaesthesia 
Mechanical Ventilation: State of the Art
Effects of airway occlusion on breathing muscle electromyogram signals, during isoflurane anaesthesia, with and without the effects of fentanyl and hypercapnia 
The upper airway during anaesthesia
Static versus dynamic respiratory mechanics for setting the ventilator
Pleural mechanics and the pathophysiology of air leaks
Physiological comparison of spontaneous and positive-pressure ventilation in laryngotracheal stenosis  S.A.R. Nouraei, D.A. Giussani, D.J. Howard, G.S.
Respiratory resistance during anaesthesia with isoflurane, sevoflurane, and desflurane: a randomized clinical trial  V. Nyktari, A. Papaioannou, N. Volakakis,
Model-based administration of inhalation anaesthesia. 2
Practical assessment of respiratory mechanics
L.W. Sturesson, G. Malmkvist, M. Bodelsson, L. Niklason, B. Jonson 
J.A. Short, S.T. Paris, P.D. Booker, R Fletcher 
L.M. Ferguson, G.B. Drummond  British Journal of Anaesthesia 
Recent advances in gas exchange measurement in intensive care patients
J. Hofland, I. GuÕltuna, R. Tenbrinck  British Journal of Anaesthesia 
Lung Volumes 17-Apr-19 Lung Volumes.
Volume 140, Issue 2, Pages (August 2011)
Shape-signal method of triggering combines shape signal (A) and volume (B) methods of triggering. Shape-signal method of triggering combines shape signal.
Association of airway obstruction, sleep, and phasic abdominal muscle activity after upper abdominal surgery†  M.Q. Rahman, R.N. Kingshott, P. Wraith,
Effects of anaesthesia on paediatric lung function
New ventilators for the ICU—usefulness of lung performance reporting
The abdominal muscles in anaesthesia and after surgery
Systemic recirculation assessed in apnoeic anaesthetized patients using carbon dioxide concentration measurements during stepwise expiration  F. Pizzichetta,
Tidal pressure–volume loops (i.e.
B. Pearce, G.B. Drummond  British Journal of Anaesthesia 
An appropriate inspiratory flow pattern can enhance CO2 exchange, facilitating protective ventilation of healthy lungs  L.W. Sturesson, G. Malmkvist,
Wu A , Drummond G.B.   British Journal of Anaesthesia 
P. Persson, O. Stenqvist, S. Lundin  British Journal of Anaesthesia 
Volume 140, Issue 1, Pages (July 2011)
J.H. Philip  British Journal of Anaesthesia 
Pressure (P)–volume (V) relationships of the total respiratory system a) in normal and b) in chronic obstructive pulmonary disease (COPD). Pressure (P)–volume.
The peak flows (60 L/min) and flow patterns are the same for all the breaths. The peak flows (60 L/min) and flow patterns are the same for all the breaths.
Capire e interpretare le curve sul ventilatore
This tracing depicts 30 seconds of information.
Alveolar recruitment in acute lung injury
Effect of respiratory mechanics on cycling of pressure support from inhalation to exhalation. Effect of respiratory mechanics on cycling of pressure support.
Presentation transcript:

Patient–ventilator interaction E Kondili, G Prinianakis, D Georgopoulos  British Journal of Anaesthesia  Volume 91, Issue 1, Pages 106-119 (July 2003) DOI: 10.1093/bja/aeg129 Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 1 Variables that influence patient–ventilator interaction. Dotted lines indicate various feedback systems. Pmus=respiratory muscle pressure; Paw=ventilator pressure; V˙=flow; V=volume relative to passive functional residual capacity; R and E=resistance and elastance of respiratory system, respectively. See text for details. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 2 Flow–time waveform in two patients ventilated with a Vision ventilator on pressure support mode. Inspiration is down and expiration is up. Open arrows indicate the flow shape signal, generated by offsetting (0.25 litre s−1) and delaying (300 ms) the actual flow (thick line) during inspiration and expiration. Closed arrows indicate the electronic signal rising in proportion to actual inspiratory flow (thick line) in each breath. (a) Mechanical breath triggered and terminated by the shape method. During expiration the actual flow decreased abruptly (due to the onset of inspiratory effort), crossed the flow shape signal and triggered the ventilator. During inspiration the acute decrease in inspiratory flow caused the actual flow to cross the flow shape signal and terminated the pressure delivery (cycling off) before the electronic signal equalled the actual flow. (b) Mechanical breath triggered by the volume method and terminated by the spontaneous expiratory threshold. During expiration the actual flow did not cross the flow shape signal (the actual flow crossed the shape signal after the triggering). The ventilator was triggered when 6 ml of volume was inspired. During expiration the electronic signal equalled the actual flow and terminated the pressure delivery (cycling off) before the actual flow crossed the shape signal flow.43 See text for details. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 3 Flow and airway (Paw) and oesophageal (Poes) pressures in a patient with severe chronic obstructive pulmonary disease ventilated with pressure support. Dotted vertical lines indicate the beginning of inspiratory efforts that triggered the ventilator. Closed arrows indicate ineffective efforts. Notice the time delay between the beginning of inspiratory effort and ventilator triggering. Observe also that ineffective efforts occurred during both mechanical inspiration and expiration. These ineffective efforts may be identified easily using the flow tracings; ineffective efforts during mechanical inspiration result in an abrupt increase in inspiratory flow, whereas during expiration they result in an abrupt decrease in expiratory flow (open arrows in flow tracing). The ventilator frequency is 12 bpm and that of the patient is 33 inspiratory efforts min−1. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 4 Airway pressure (Paw), flow and oesophageal pressure (Poes) in a patient with chronic obstructive lung disease ventilated with assist volume control with two inspiratory flow rates (V˙I), 30 litres min−1 (a) and 90 litres min−1 (b). With both flow rates tidal volume (VT) was kept constant (0.55 litre). Ineffective efforts are indicated by arrows. By increasing the time available for expiration (increase in inspiratory flow at constant VT; panel b), dynamic hyperinflation was decreased and as a result the number of ineffective efforts was reduced and the rate of the ventilator increased. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 5 End-tidal carbon dioxide tension (PE′CO2), airway pressure (Paw), flow (inspiration up), volume (inspiration up) and oesophageal (Poes) pressure in a representative subject during proportional assist ventilation (a, b), pressure support (c, d) and assist volume control (e, f) without (a, c, e) and with (b, d, f) carbon dioxide challenge. Observe the different response of Paw with carbon dioxide stimulation between the three modes of support. From reference 38. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 6 Flow and airway (Paw) and oesophageal (Poes) pressures in a patient recovering from acute lung injury and ventilated with assist volume control with constant inspiratory flow. In the second breath, tidal volume (volume not shown) was decreased at the same inspiratory flow. As a result there was a premature end to mechanical inspiration, and because inspiratory muscles continued to contract they developed pressure which overcame the elastic recoil at the end of inspiration. As a result Paw decreased below the triggering threshold and the ventilator therefore delivered a new mechanical breath. The ventilator was triggered three times by the two inspiratory efforts. Observe the high Paw of the third mechanical breath because lung volume was greater (the volume of the third breath was added to that of the second). Notice also that total breath duration of the second respiratory effort of the patient was considerably longer than that of the first, owing to activation of the Hering–Breuer reflex by the high volume. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 7 Graded increases in pressure support cause a decrease in respiratory drive (dP/dt), associated with considerable increase in the triggering time. Adapted from reference 33. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 8 Schematic representation of the respiratory system in terms of respiratory system loop, controller and controlled gains. An input to the control centre of the respiratory system (located in the brainstem) will change the activity of respiratory muscles (motor arm) depending on (i) the sensitivity of the control centre to the input change, (ii) the integrity of the pathway that connects the control centre to respiratory muscles (bulbospinal neural tract, lower motor neurones, peripheral nerves and neuromuscular junction) and (iii) the ability of respiratory muscles to develop pressure. The change in respiratory muscle activity for a given change in the input stimulus defines the respiratory controller gain. Depending on (i) the modes of mechanical ventilation, (ii) the assist level and (iii) the mechanics of respiratory system, the activity of respiratory muscles will determine the ventilation that is the final output. The change in ventilation for a given change in respiratory muscle activity defines the respiratory system-controlled gain. The change in output (ventilation) for a given change in the input defines the respiratory system loop gain and is the product of controller and controlled gain factors. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 9 Respiratory system loop, controller and controlled gains in normal subjects ventilated with assist volume control (cross-hatched bars), proportional assist ventilation (open bars) and pressure support (hatched bars) without (initial, zero FICO2) and with carbon dioxide challenge (final FICO2 ∼7%); PTPminute=pressure time product of respiratory muscles per minute; PE′CO2=partial pressure of end tidal Pco2; V˙>e=minute ventilation. +P<0.05 compared with the corresponding value with PAV; *P<0.05 compared with the corresponding values at initial FICO2. From reference 38. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 10 Changes in flow, airway pressure (Paw), volume (ΔV) and transdiaphragmatic pressure (ΔPdi) in a patient during spontaneous breathing (SB) and during pressure support (PSV) and proportional assist ventilation (PAV) without (load off) and with chest and abdominal binding (load on). Observe the difference in breathing pattern response to load application between pressure support and proportional assist ventilation. From reference 25. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions

Fig 11 Relationship between the changes in the time that mechanical inspiration extended into neural expiration (ΔText, changes in expiratory asynchrony) and in neural expiratory time (ΔTEn) of mechanically ventilated patients with ARDS. The solid line is the regression line. Closed circles=ΔText induced by changes in volume (at constant flow); open circles=flow (at constant volume); open triangles=pressure support. From reference 32. British Journal of Anaesthesia 2003 91, 106-119DOI: (10.1093/bja/aeg129) Copyright © 2003 British Journal of Anaesthesia Terms and Conditions