Barcelona, 20/08/2011. INTRODUCTION More than 25% of the existing housing moistures are originated on the roof. Mainly caused by the lack waterproofing.

Slides:



Advertisements
Similar presentations
ROOFS.
Advertisements

Contents: Cover
Wilko Paint, Inc. Wilko Paint is the premier supplier of industrial finishes and coatings.   Our staff of industrial coatings specialists will provide.
FRIGI-TECH REFLECTIVE ROOF COATINGS. MAIN BENIFITS INSULATES – Outperforms 7 of fiberglass insulation. Keeps interiors cooler and more comfortable. CUTS.
Copyright , Facade Works Inc - Drained/Back-Ventilated Rain Screen System.
Microteja Plus ® A State of the Art Heat-Dissipating Coating.
DECORATIVE SINGLE COAT PLASTER FOR MARBLE CHIPS CLADDING SYSTEM ( PEBBLEDASH )
Chapter 16 Roofing. First line of defense against the weather Precipitation (Rain, snow) Sun Thermal Transmission Subjected to extreme heat and cold Surface.
Moisture Control. Indications of Excessive Moisture Condensation,frost or ice on the inside surface of windows Damp spots on ceilings or inner surfaces.
A passive investment towards improved control over energy costs.
RESINOUS FLOOR COATINGS
ARC313 Building Code II. Review What is the minimum bearing pressure allowed for soils to support foundations? 75 kPa How can you tell by looking at the.
Silglaze N NEUTRAL SILICONE SEALANT SCS2500 SERIES DESCRIPTION
MarineMend Repair Kit Procedure
Water Based Bituminous Liquid Membrane WATERPROOFERS TO THE NATION
How do clouds form and precipitation types (Do not write what is in blue) RRB
Customer Service – International Dept. The thermal solar systems  Installation  Commissioning  Maintenance.
SHOTCRETING K.V.SUBBA RAO.
Subfloor Evaluation Prior to Installation Understanding the science of concrete slabs prior to installation of moisture sensitive floor covering materials.
Curing and Protection of Concrete
Asphalt Materials.
® SPACE TECHNOLOGY THAT STAYS ON TOP SPM THERMO-SHIELD ® INC BY.
SYNTHETIC RED OXIDE METAL PRIMER It has good anti-corrosive properties. It contains Zinc-chrome. Recommended for agricultural, steel structures & other.
1470 NW 107 th Ave Suite E, Miami, FL Phone:
Roofing Barrier System AC100 RF Best Coat  SCS Coatings, LLC 8 Timberbrooke Drive, Hopewell, NJ
Example of a successful lining Description: Tuff Stuff is sprayed as a protective lining onto a boat hull. The lining with TS provides a high level of.
Presentation Agenda IKO Overview Polimar Systems Presented by
PAVEMENT MAINTENANCE II Part 1b: Chip Seal Construction Idaho Roads Scholar Program.
THERMAL INSULATION IN THE NEW ERA. INSULATION THICKNESS IN EUROPE ROOFS.
Repair Methods of the Roofing Structures Rak Repair Methods of Structures, exercise (4 cr) Esko Sistonen.
ROOF MATE Step-By-Step Application Over MODIFIED BITUMEN ROOFING Master Guide Specifications List of materials: ROOF MATE WHITE ROOF MATE BASECOAT ROOF.
A member of Sayegh Group
Relevance of Ambient Conditions Temperature/humidity restrictions often ignored Air and surface temperature can be too hot or too cold for proper film.
What is Liquid Rubber? An asphalt emulsion coating engineered to provide exceptional adhesive, elastic & protective properties An asphalt emulsion coating.
 Single Component Products TT-P-1952E - Waterborne traffic paint TT-P-1952E - Waterborne traffic paint A-A-2886A - Solvent traffic paint A-A-2886A - Solvent.
OPTIMUM COATING SOLUTIONS OPTEK PRODUCTS CEMETITIOUS COATINGS AND ADDITIVES Brief overveiw.
SELECTION AND INSTALLATION OF BRIDGE EXPANSION JOINTS
ROOF MATE Step-By-Step Application Over METAL ROOFING Master Guide Specifications List of Materials: ROOF MATE WHITE ROOF MATE BASECOAT ROOF MATE BUTTER.
Student Book © 2004 Propane Education & Research CouncilPage Applying Protective Coatings to Storage Containers ASME tanks require proper.
Presented by: Peter Emmons,
ROOF MATE Step-By-Step Application Over EPDM ROOFING Master Guide Specifications List of Materials: ROOF MATE WHITE ROOF MATE LIGHT GRAY ROOF MATE BUTTER.
Protactinium 台 灣 拓 鏷 化 工 PD-660.  Oriental Star insulation paints are compounded of polymeric resins and inorganic insulating powders, which features.
The new technology for watertight construction joints
ROOF MATE Step-By-Step Application Over CONCRETE ROOFING
BondChem TECHNICAL DATA Roll-a-crete ( Three Component Cementitious Waterproof Coating ) Page 1 / 2. DESCRIPTION BondChem’s Roll-a-crete is a three component.
Aqua-Mite The one and only true water proofing coating designed for permanent under water usage.
Chapter 23 Plumbing Systems. Objectives After reading the chapter and reviewing the materials presented the students will be able to: Identify several.
TEAM: FIBREX Waterproofing Coating. Introduction  The ASTM Standard defines it is a treatment of a surface to prevent the passage of water under hydrostatic.
Aqua-Therm Superior roof waterproofing system. Aqua-Therm Aqua-Therm is a uniquely formulated two pack coating system, the first of it's kind in the world,
LiquiGard ™ Firestone Building Products. LiquiGard ™ About Firestone LiquiGard™ is a tough, liquid applied, two-part polyurethane adhesive. It forms a.
Air Leakage and Water Vapor Control Chapter 6. Mehta, Scarborough, and Armpriest : Building Construction: Principles, Materials, and Systems © 2008 Pearson.
Concrete Countertops. Cast in place Pre – Cast Overlay.
2- Available Conformal Coatings Chemistries and Technologies.
BUILDING CONSTRUCTION ( ) GOVERNMENT ENGINEERING COLLEGE,DAHOD CIVIL ENGINEERING DEPARTMENT PRESENTED BY: PATEL TEJASH S. ( ) GUIDE BY:
Causes of fire &precaution: The variouscauses of fire are as follows: 1. Careless smoking. 2. Faulty electrical wiring or short circuiting. 1.
Curing Definition The process of prevention of loss of moisture from fresh concrete while maintaining satisfactory temperature regime (BS 8110) Fig: The.
STATIC CONTROL TILES & SHEETING PRIMO SD. INTRODUCTION  Static Dissipative flooring is essential for protecting sensitive equipment from static charge.
Call Us: Roofing Materials.
Welcome To Astec Paints Paint With Pride
Beyem Fir White Enhanced cement based tile adhesive for interior use
High Density Polyethylene (HDPE) Panels or Sheets
Prepared By: Alka Shah Civil Engineering Department
DAMP-PROOFING AND WATER-PROOFING COURSE
Chapter 10 Construction Basics.
“Thermo reflective Nano technological treatment "
Interior Finishes and Detailing
Building Construction I Sofia Sebastian 1
Building Construction I Sofia Sebastian 1
Who is Weatherskin? WEATHERSKIN is a North American company who is focused on developing the highest caliber, eco-friendly coatings for use in the construction.
Presentation transcript:

Barcelona, 20/08/2011

INTRODUCTION More than 25% of the existing housing moistures are originated on the roof. Mainly caused by the lack waterproofing solution or the failure. A roof is a protection element exposed to atmospheric agents (rain, ice, snow, solar radiation, pollution, etc.) Barcelona, 20/08/2011

ROOF TYPES Following its shape: Flat or bent skirt, flat or pitched, simple or double bent, etc. Following its constructive elements: Homogeneous (one layer), heterogeneous (multiple layers) Following its protection or finishing: Concrete, tiles, stoneware, panels, etc. Following its uses: Trafficable (not vehicular), non trafficable or green roofs. Barcelona, 20/08/2011

WATERPROOFING TYPES The most important characteristic from a waterproofing system is its sealing power against atmospheric and pollution agents. Most common types: Waterproofing sheets (bituminous or synthetic) Metal sheets (folding and moldable) Metal deck- Metal panels Big elements with sealed joints Overlap elements (tiles, slates) Liquid ( bitumen emulsions, acrylic emulsions, epoxy, PU, polyuria, etc.) Barcelona, 20/08/2011

PATHOLOGICAL AGENTS RAIN WATER CONDENSATION OR DEW HAIL WIND FREEZE-THAW SOLAR RADIATION POLLUTION Barcelona, 20/08/2011

PRODUCT DESCRIPTION Elastic coating based on an acrylic copolymer emulsion Barcelona, 20/08/2011

TECHNICAL PROPERTIES Adaptive liquid membrane for structures with irregular geometry. Monolithic membrane without joints or overlaps and securely attached. Water based. Thinner, tar or any asphalt derivate product free. Easy to apply: single-component, roller, brush or airless spray. 100% waterproof. Breathable to water vapor. I allows the support to breath. Barcelona, 20/08/2011

TECHNICAL PROPERTIES Very good elongation properties. High absorption capacity to the roof movements caused by temperature changes or settlement. Great endurance to atmospheric agents. Formulated to comply with UNE norm for flexible coatings without reinforcement. Environmentally friendly, complies with Directive 2004/42/CE in relation with Volatile organic compounds (VOC). Barcelona, 20/08/2011

USES Specially indicated for waterproofing of external concrete surfaces, precast concrete, bitumen waterproofing, tiles, asbestos cement, projected PU foam, expanded polyethylene and wood (balconies and terraces), roofs, vaults, balconies, gutters, pots, etc. In liquid applied waterproofing for non trafficable balconies and terraces, for private use when reinforced with geotextile IMPERTEXSA A-50. Protection of polyurethane foam insulation. Barcelona, 20/08/2011

USES In adaptive liquid waterproofing coating for structures with irregular geometry and protective coating on vertical walls. Provides a monolithic continuous elastic and flexible coating without joints or overlaps. In repair and rehabilitation waterproofing work over concrete, mortar, asbestos cement, non glass ceramic tiles, tiles, wood, etc. Protection of concrete structures in marine environment. Barcelona, 20/08/2011

TECHNICAL DATA Barcelona, 20/08/2011 CharacteristicsValue AspectSemi matt ColorWhite, blue, red, grey, green and terracotta. Viscosity centipoises Solid Volume42 – 45% Consumption2 kilos / m², in two or three layers Tack3 hours at 20º C Elongation at Break400 – 600% Cold bendingNo cracks between – 5ºC and 180°C Washability> cycles following UNE VOCComplies with Directive 2004/42/CE, Annex I subclass c) 3,9 – 4,1 g/l depending on the color (40g/l maximum 2010)

APPLICATION Application method : roller, brush or airless spray. Dilution : 0 to 5% Diluent and cleaning : Water Repainting time: hours at 20º C –Can be repainted after cleaning the existing coating as much as needed. Application conditions: Working temperatures must be above 10 °C and below 35 °. RH below 80 %. Temperatures of support and coating must be within the application conditions too. Barcelona, 20/08/2011

APPLICATION Support : The concrete structures must be cured for 28 days. The surface to be treated should be clean of grease, oil, curing chemicals, dust and dirt. IMPERTEXSA can be applied directly on wet substrate following sealing procedure. Eliminate surface irregularities. Do not apply on loose, dusty, unclean substrates which are unacceptable to receive the coating. If required use mechanical or manual tools to clean the support. Resurface and seal the cracks with polyurethane caulk, reinforced with ROOFTEX FLEECE 80 wherever necessary. Treat the expansion joints (according to standards) and seal with polyurethane caulk. Barcelona, 20/08/2011

APPLICATION Support : We recommend using a thin geotextile interlayer to control the film thickness and uniformity. Sealing: Apply on layer of IMPERTEXSA CUBIERTAS 20% diluted with water. Drying time 2 to 4 hours at 20º C. Finishing: Apply two layers of IMPERTEXSA CUBIERTAS without diluting. Drying time between layers is 12 hours. Barcelona, 20/08/2011

PRECAUTIONS Dont apply IMPERTEXSA CUBIERTAS if rain is forecasted during drying time, on cloudy days or during maximum insolation hours. Drying time and repainting time may vary following weather conditions. Apply on surfaces with enough slope to avoid stagnant water. This product is not recommended for trafficable areas, although temporary pedestrian accessibility is allowed for maintenance jobs. Barcelona, 20/08/2011

PRECAUTIONS Avoid direct exposition to sun of the containers. For a correct waterproofing, we recommend to cross layers between first and second hand, reaching a better distribution of the coating and correctly regularize the consumption. On roof waterproofing, parapet (walls) must be painted with a minimum high of 15 cm. Dont use brackish water, chemically polluted, cloudy or calcareous in excess. It could be alter the product properties. Storage of the containers must be protected from frost, prolonged exposure to sunlight and high temperatures. Barcelona, 20/08/2011

PACKING 20 and 5 kilos drums. Colors: White, blue, red, terracotta, green and grey. Recommended maximum storage time: 1 year at 25 º C in their respective containers. Barcelona, 20/08/2011

SAFETY Water based product. Each container has a safety label with instructions that must be observed. National an local safety regulation must also be respected. Avoid inhalation of vapor or direct contact of the painting with skin and eyes. If applied on enclosed rooms, force ventilation is required. Use personal protective equipment.. IMPERTEXA CUBIERTAS is free of nonylphenols, formaldehydes, thinners, tar, asphalt or chloride plasticizers. Barcelona, 20/08/2011

APPLICATION EXEMPLES Barcelona, 20/08/2011

APPLICATION EXEMPLES Barcelona, 20/08/2011

APPLICATION EXEMPLES Barcelona, 20/08/2011

APPLICATION EXEMPLES Barcelona, 20/08/2011

APPLICATION EXEMPLES Barcelona, 20/08/2011

APPLICATION EXEMPLES Barcelona, 20/08/2011

THANKS Barcelona, 20/08/2011