ESD Protection 02/12/2018 Radiometer Medical ApS 2 December, 2018.

Slides:



Advertisements
Similar presentations
ESD Basics and Protection
Advertisements

Unlocking the Mystery of Circuit Board Failures A Case Study Presented By: Alaa Arif EDTC 560 January 15, 2007.
Compliance Verification Testing of Installed ESD Protective Products
3 Static Awareness Seminar.
Mission Success Starts With Safety GSFC Electrostatic Discharge (ESD) Control Program Are you plugged in? Jeannette Plante, Program Manager, Code 300.
IT Essentials: PC Hardware and Software v4.0. Chapter 2 Objectives 2.1 Explain the purpose of safe working conditions and procedures 2.2 Identify tools.
Verigy V93000 Service Training
Customer Satisfaction No.1. Pioneer Electronics Service (PSE)
Safety/Electrostatic Discharge (ESD) Computer Maintenance Copyright © Texas Education Agency, All rights reserved.1.
 Workshop induction. Hazards Magazine,
CIT In this chapter you will learn how to:  Care for the external parts of the computer  Describe methods for keeping the inside of the case problem-free.
Tom Watkins President Transforming Technologies. Outline Generation of Static Charge Effects of Static Charge Physical damage Contamination Automation.
ESD Constant Monitor System Packaging Bench set-up.
ElectroStatic Discharge (ESD)
S Changes and Procedures
1 Student Hands On Training I (2009) Soldering 101.
Power Supplies Chapter 6. Understanding Electricity Electricity is simply a flow of negatively charged particles, called electrons, through matter Materials.
A+ certification training: Electricity/Power Supply.
ESD BASICS Basic Concepts in ElectroStatic Discharge (ESD) ©Copyright 2012 VermasonMarch 2012.
Chapter 12 Electronics.
ESD Control Experts Electrical Overstress (EOS) and Electrostatic Discharge (ESD) Event StaticControl.com © 2015 Desco Industries Inc.
Model Continuous Workstation Monitor, Dual Wire ©Copyright 2003 DESCO INDUSTRIES INC.
ElectroStatic Discharge (ESD)
© 2015 Desco Industries Inc. StaticControl.com ESD Control Experts HBM vs. CDM vs. CBE What is the difference?
4/20/2017 © 2015 Vermason Ltd..
1 © 2008 Cisco Systems, Inc. All rights reserved.Cisco Confidential014874_11_2008 ESD Best Practices Electrostatic Discharge and Grounding Cisco Best Practices.
ELECTRO STATIC DISCHARGE
ElectroStatic Discharge (ESD)
Unit 4, Lesson 9 Keeping You and Your Computer Safe AOIT Computer Systems Copyright © 2008–2013 National Academy Foundation. All rights reserved.
PC Repair Fundamentals 1. Objectives Learn about tools you’ll need as a computer support technician Learn how to develop a preventive maintenance plan.
© 2006 Cisco Systems, Inc. All rights reserved.Cisco Public ITE PC v4.0 Chapter 2 1 Chapter 2: Safe Lab Procedures and Tool Use IT Essentials: PC Hardware.
© Cisco Systems, Inc. All rights reserved. Cisco Public ITE PC v4.1 Chapter 2 1 Chapter 2: Safe Lab Procedures and Tool Use IT Essentials:
1 Safety and Preventative Maintenance. 2 MB, One megabyte - MB or M-byte - represents about 1 million (10 6 ) bytes. Precisely, 1 MB = = 1 kB x 1 kB =
Tools.
Course ILT Electricity and power systems Unit objectives Measure and describe the characteristics of electricity Identify static electricity and follow.
Do this now… Go to and complete the pre-lesson survey. Go to my eBoard and set up.
Copyright © 2008–2011 National Academy Foundation. All rights reserved. Unit 4, Lesson 9 Keeping You and Your Computer Safe AOIT Computer Systems.
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
Safety. Outcomes  Potential health hazards when working with computer equipment.  Precautions to take to prevent injuries.  Steps and techniques for.
Course ILT Safety Unit objectives Identify safety issues and hazards in the computer environment Identify ways to avoid injury and strain when working.
Course ILT Troubleshooting and maintaining a PC Unit objectives Identify tools and software that make up a troubleshooter’s toolkit Perform preventive.
Troubleshooting Equipment Containing Integrated Circuits Jimmie Fouts Houston County Career Academy.
PC Maintenance By Tammy Pratt University of Phoenix EDTC560.
Safe Lab Procedures and Tool Use
Electrical Testers Basic test equipment used in today’s shops may include an analog type meter, a VAT (Volt-Amp-Tester), DMM (Digital Multimeter),
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 2: Safe Lab Procedures and Tool Use IT Essentials 5.0.
Chapter 3 PHYSICAL INJURY AND CONTROLS 3.2 Electrical Safety
HOW NOT TO INCORRECTLY CARE FOR COMPUTER HARDWARE HANDLING AND STORAGE BY BLAINE AND ZACH.
Safety/Electrostatic Discharge (ESD)
CompTIA Server+ Certification (Exam SK0-004)
Chapter 2: Introduction to Lab Procedures and Tool Use
Overall Comprehensive ESD Control Programme Required Use ESD Control Products Correctly or You Can Do More Harm Than Good ©Copyright 2017 DESCO EUROPE.
Static Management Program (SMP)
© 2008 Cisco Systems, Inc. All rights reserved.Cisco ConfidentialPresentation_ID 1 Chapter 2: Safe Lab Procedures and Tool Use IT Essentials 5.0.
ELECTRIC DISCHARGE.
Automotive Electronics
Electro Static Discharge Control
Electricity & Magnetism
Apply your knowledge Module 2.
Dealing With Static Discharge In Polar Environments
Review basic safety precautions
Computer Repair & Maintenance
Electricity & Magnetism
Static Eraser for ESD protection
Static Management Program (SMP)
Soldering: Methods, Tips, and Applications
ESD Procedures for the Electronics Industry
the most complete monitoring solution on the market
Electricity & Magnetism
Presentation transcript:

ESD Protection 02/12/2018 Radiometer Medical ApS 2 December, 2018

Electro Static Discharge (ESD) 02/12/2018 RADIOMETER PRESENTATION Electro Static Discharge (ESD)

Electro Static Charge and Discharge Fundamentals 02/12/2018 RADIOMETER PRESENTATION Electro Static Charge and Discharge Fundamentals Whenever there is movement, static charge is produced Static charge is caused by an excess or deficiency of electrons collected on a surface Electro Static Discharge is the rapid flow of charge between two objects

When Is a Static Charge Present? 02/12/2018 RADIOMETER PRESENTATION When Is a Static Charge Present? A person walking on a carpet up to 35000 volts A person walking on a vinyl floor 12000 volts A person on a padded chair up to 18000 volts Styrofoam coffee cup up to 5000 volts Plastic or scotch tape up to 5000 volts Vinyl covered notebook (Service Manual) up to 8000 volts

Electro Static Discharge 02/12/2018 RADIOMETER PRESENTATION Electro Static Discharge TO FEEL IT -- 3500 volts or more TO HEAR IT -- 4500 volts or more TO SEE THE SPARK -- 5000 volts or more

Component damaging Voltage Levels 02/12/2018 RADIOMETER PRESENTATION Component damaging Voltage Levels Device type Range of ESD Vulnerability (volts) VMOS 30-1800 MOSFET 100-200 EPROM 100 JFET 140-7000 SAW 150-500 OP AMP 190-2500 CMOS 250-3000 Diodes 300-2500 The range where a injury can occur. Bipolar Transistors 380-7000 TTL 1000-2500 Reference: Radiometer ESD book, code number 919-553 Radiometer Medical ApS 2 December, 2018

Electro Static Discharge 02/12/2018 RADIOMETER PRESENTATION Electro Static Discharge 90 % That are damaged by ESD are Zinged 10 % That are damaged by ESD are Zapped. Zinged: Components’ life span is reduced Operating Characteristic changed (intermittent failures) Temperature sensitivity Zapped: - Component totally destroyed

ESD Protected Area Static Dissipative Bench Mat ESD protected floor 02/12/2018 RADIOMETER PRESENTATION ESD Protected Area Static Dissipative Bench Mat ESD protected floor Wrist Strap (1MΩ) Look for the sign:

General Requirements Instrument for repair must be grounded 02/12/2018 RADIOMETER PRESENTATION General Requirements Instrument for repair must be grounded Service person must have wrist strap connected Mains supplied test instruments must be grounded Solder iron must be grounded Discharge tools on bench mat before use Clean up Make ESD protected area visible Train the personnel Check facilities regularly

02/12/2018 RADIOMETER PRESENTATION Grounding Example 1

02/12/2018 RADIOMETER PRESENTATION Grounding Example 2

02/12/2018 RADIOMETER PRESENTATION Grounding Example 3

Working Instructions Perform grounding (instrument, person, bench mat) 02/12/2018 RADIOMETER PRESENTATION Working Instructions Perform grounding (instrument, person, bench mat) Dismantle instrument Unpack replacement board and mount in instrument Place faulty/suspect board in ESD protected bag Remount instrument case

02/12/2018 RADIOMETER PRESENTATION Inventory / Transport ESD sensitive devices will be delivered in protected bags or boxes ESD sensitive devices must be kept in protected bags or boxes outside protected area Unprotected ESD sensitive devices must be rejected

02/12/2018 RADIOMETER PRESENTATION Cleaning ESD Vacuum cleaner

RADIOMETER ESD stock items 02/12/2018 RADIOMETER PRESENTATION RADIOMETER ESD stock items 3M bench mat type 8214 -R- part no. 993-072 3M field kit type 8501 -R- part no. 993-073 3M wrist band type 2204 -R- part no. 920-716 3M cord for 2204, 1.5 m -R- part no. 617-925 3M cord for 2204, 3 m -R- part no. 617-926 3M bag 150 x 250 mm -R- part no. 955-053 3M bag 200 x 300 mm -R- part no. 955-054 3M bag 250 x 350 mm -R- part no. 955-055 3M bag 350 x 450 mm -R- part no. 955-056

02/12/2018 RADIOMETER PRESENTATION Implementation Manufacturing and stocking facilities in Copenhagen, January 15, 1993 Distributors service and stocking facilities, May 15, 1993

Questionnaire Have you implemented ESD protection in your company ? 02/12/2018 RADIOMETER PRESENTATION Questionnaire Have you implemented ESD protection in your company ? Yes No Have the person responsible for your stock received training in ESD ? Yes No Have you got ESD protected areas in your workshop ? Yes No Have you got portable ESD protection equipment ? Yes No Do you feel that you now have enough information to implement ESD protection in your company ? Yes No

End of Session 02/12/2018 Radiometer Medical ApS 2 December, 2018