Presentation On INERGEN

Slides:



Advertisements
Similar presentations
SCS East Region Safety & Health
Advertisements

Mine Gases Atmospheric Testing C.4. Contributed by: Richard Black Industrial Scientific Corp.
Multiplication X 1 1 x 1 = 1 2 x 1 = 2 3 x 1 = 3 4 x 1 = 4 5 x 1 = 5 6 x 1 = 6 7 x 1 = 7 8 x 1 = 8 9 x 1 = 9 10 x 1 = x 1 = x 1 = 12 X 2 1.
Division ÷ 1 1 ÷ 1 = 1 2 ÷ 1 = 2 3 ÷ 1 = 3 4 ÷ 1 = 4 5 ÷ 1 = 5 6 ÷ 1 = 6 7 ÷ 1 = 7 8 ÷ 1 = 8 9 ÷ 1 = 9 10 ÷ 1 = ÷ 1 = ÷ 1 = 12 ÷ 2 2 ÷ 2 =
Unit B: Safety in Agricultural Mechanics
OXYGEN-ALTERNATE FUEL TORCH EASY SET UP June 4, 2011 Chad Koens District Manager
Pneumatic Principles.
Green house Effect Simulation
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Understanding Its Causes
Flammable and Combustible Liquid & Compressed Gas Handling and Storage
Let’s watch a DVD… DVD Instructor Notes
1. 2 Earthquake effects on health care facilities 2.
SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
PPE: Clothing/Ensembles
Halon Replacement for Airplane Cargo Compartments What it Takes Fourth Triennial International Fire and Cabin Safety Research Conference Lisbon, Portugal.
Fire Extinguishers 29 CFR Session Objectives You will be able to: Identify different classes of fire Choose the appropriate type of extinguisher.
US Chemical Safety and Hazard Investigation Board The Hazards of Nitrogen Asphyxiation.
Compressed Gas Cylinder Safety
East Carolina University Compressed Gas Safety Training Program
Compressed Gas Cylinder Safety
The Gas Advantage ! Information contained in this document is the intellectual property of Venus Gas Products & Services (Mysore) Pvt. Ltd. (VGPSPL) and.
Boilers Dept. of Mech & Mfg. Engg..
1 A GUIDE TO LABORATORY SAFETY School of Engineering and Science February 2009 HEALTH, ENGINEERING AND SCIENCE.
There are three types of emergencies:  Internal  External  Natural disasters.
Gas Management Systems
Fire Extinguisher Training
Halon Systems Ch. 5, pages HALogenated hydrocarbON not the same as halogen F, Cl, Br, I 1940’s ’s extremely effective.
© Siemens Industry, Inc Confidential / Drive Your Business Forward Ignite the Power of New Products and Partnerships Siemens Fire Partner Summit.
Fire Detection and Suppression Chapter 7 Special Extinguishing Systems.
Viking TotalPac2 FireFlex Dual / 1230
Section 2 Safety, Tools and Equipment, Shop Practices Unit 4 General Safety Practices.
Damage Control II Objectives DC Actions & Reports DC Actions & Reports Classes of Fires & Combating them Classes of Fires & Combating them Firefighting.
Stages of Fire Detections and Extinguishants From Ginge-Kerr Danmark A/s & BMTT Corporation S/B (www. ginge-kerr.com)
Atlantic Beach Fire Department Presents: For Business Employees and the General Public.
The three essential ingredient for creating a fire are HEAT, AIR AND FUEL Fire triangle.
Visual 2.1 Introduction and Unit Overview The role of CERTs in fire safety:  Put out small fires.  Prevent additional fires.  Shutoff utilities  Assist.
In today’s global business environment, the need for clean agent fire suppression has never been greater. Pem All.
Fire Safety & Fire Extinguisher Use. OBJECTIVES Understand the combustion process and different fire classes Understand fire extinguisher types, operating.
Portable Fire Extinguishers Selection and Placement University Safety Council April 19, 2006 Steven G. Triebold Fire Prevention and Protection Program.
LNG Hazards.
What you will learn in this session 1.The characteristics of fire, smoke and toxic fumes 2.Fire hazards involved in the working environment 3.Significant.
Clean Agent Fire Suppression Alternatives
Fire Risk Assessment.
Control Rooms  Serve as operations centers for the control and monitoring of a service or process  Flight control rooms  Power generation control rooms.
Unit 8: Portable Fire Extinguishers & Smoke Control Management Systems
Inert Gas Fire Extinguishants
SINORIXTM CDT Product Presentation.
NEXT GENERATION Kidde Engineered Fire Suppression System Designed for use with 3M™ Novec™ 1230 Fire Protection Fluid.
Welding and Cutting for construction. Welding safety program guidelines Person responsible Accountability and enforcement Job hazard assessment Special.
CXS490 Carbon Dioxide Systems
CLIC CES Webex 12 Nov Summary: – Set of fire safety measures defined in CERN Safety Report – Proposed Structure for CLIC/ILC Fire Safety Report Fabio.
Anhydrous Ammonia Emergency Preparedness v Information from the 2012 Emergency Response Guidebook v ID # 1005 v Guide # 125 v Name of Material Anhydrous.
3M™ Novec 1230™ Fire Protection Fluid
Unit 4: General Safety Practices
Tyson Burt Mathieu Gagnon
FIRE SERVICES AT DATA CENTRE
Add name of trust / organisation in box 1 and name of trainer in box 2. Delete THIS box.
Kidde FM-200® Product Review
2012 Lik Kai Pacific Sense March PACIFIC SENSE Company Intro.
Metal Fabrication Oxygen & Acetylene Integra ® Cylinders 2014.
Health & Safety Risk Management
Johan Bremer, 22th-26th September 2008 Cryogenics Operations 2008, CERN, Geneva, Switzerland 1 CRYOGENICS OPERATIONS 2008 Organized by CERN Safety aspects.
What you will learn in this session 1.The characteristics of fire, smoke and toxic fumes 2.Fire hazards involved in the working environment 3.Significant.
Fire Extinguishers 29 CFR © Business & Legal Reports, Inc Session Objectives You will be able to: Identify different classes of fire Choose.
General Safety Practices
Emergency Electrical Power Supply for Buildings
Firefighting equipment
Fire Suppression for your IT Solution
Presentation transcript:

Presentation On INERGEN Romeetech Engineering & Services Introducing Inergen Bijan Kumar Mani Managing Partner - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Fire triangle Oxygen Fuel Heat The fire needs Fuel, Heat and Oxygen. Remove or lower one of those and the fire is extinguished. The fire goes out if the oxygen level is below 15% Oxygen Fuel Heat - Perfectly Safe for People, Property, the Planet…. and your Pocket!

How does Inergen work? - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Why Inergen? Unlike any other suppression agent like, Water, DCP, Foam, or gases like CO2, FM200, ,Nitrogen, Argonite or Halon 1301 INERGEN will: Extinguish the fire and inhibit re- ignition, with no risk to people or damage to equipment and no impact on the environment - Perfectly Safe for People, Property, the Planet…. and your Pocket!

This is really possible! Wouldn’t it be fantastic to extinguish fire with the air that we breathe? - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Inergen Safe for People Safe for Property NO adverse effects on people. Contains a small amount of CO2 to stimulate the uptake of oxygen Does not create a fog ensuring that escape routes are always visible Safe for Property Harmless on physical assets like equipment furniture etc. Leaves no residue to clean up and does not produce any toxic by-products - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Safe for the Planet Safe for your Pocket Inergen Inergen is as safe as the air we breathe! Safe for your Pocket Inergen will never be banned Central cylinder banking to protect multiple areas Naturally existing gases makes maintenance and refills easy 10 year Evergreen warranty takes all your problems away - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Manufactured by Mother Nature Inergen Manufactured by Mother Nature - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Inergen Comparatively Less Spaces & Less Maintenance Cost Than Other INERGEN System 300 Bar Cylinders with Accessories From Fire eater , Denmark Supplied with UL listed Manifolds UL Listed Products - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Advantage Of 300 Bar Cylinder Inergen It is only 300 Bar cylinder store pressure and the system pressure is same as other pressure rating like 200 Bar & 150 Bar. No of cylinder reduce to 2/3rd as compared to 200 Bar and just ½ as compared to 150 Bar. 300/200/150 Bar all cylinders are UL Listed and Certified which ensure the best safety aspect of the products. Civil construction cost reduces drastically . Spaces saving. Initial investment are much less since the no of cylinder is less. Accessories are also less. Maintenance cost for refill and others spare parts are less. Easy remote monitoring round the clock to ensure correct functionality all the time. - Perfectly Safe for People, Property, the Planet…. and your Pocket!

New Inergen Atmosphere Safe for people New Inergen Atmosphere NITROGEN 68% Lowers oxygen level below 15% ARGON 16% The INERGEN atmosphere has a density similar to normal air – with a long retention time of 20 to 30 minutes CO2 4% Increases human respiration rate and oxygen transfer to brain – protects human life OXYGEN 12 - 12.5% Fires are extinguished below 15% - Perfectly Safe for People, Property, the Planet…. and your Pocket!

U.S. Research Program – Test Results Test atmospheres O2 21% O2 10% Medically supervised tests carried out with human beings Test atmospheres: Air 21% oxygen Hypoxia 10% oxygen Inergen 10% O2 + 4% CO2 Source: University of Pennsylvania - Perfectly Safe for People, Property, the Planet…. and your Pocket!

O2 21% Blood oxygenation O2 10% Safe for people Blood oxygenation O2 21% O2 10% Inergen maintains brain oxygen at normal levels due to the CO2 content. Lowering the Oxygen level using any other Inert gas does not. - Perfectly Safe for People, Property, the Planet…. and your Pocket!

O2 21% Safe for people Pulse rate O2 10% Inergen does not affect the heart rate in low oxygen atmospheres Critical for people with heart disease. 100 90 80 70 60 50 O2 10% O2 21% - Perfectly Safe for People, Property, the Planet…. and your Pocket!

O2 21% Safe for people Word and number tests O2 10% 10 20 30 Word and number tests O2 21% O2 10% Inergen maintains mental performance in low oxygen atmospheres Good for an emergency situation! - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Generates NO Toxic Breakdown Products - HF (Hydrogen Fluoride Gas) Safe for property NO Thermal Shock Generates NO Toxic Breakdown Products - HF (Hydrogen Fluoride Gas) Long “Holding” Time Generates no residue - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Safe for property THERMAL SHOCK Electronics can be adversely affected by sudden temperature changes Change from temperature 20oC to: Agent Temp Time Halon 1301 9.3oC 10 sec. Inergen 15.2oC 1 min. FM-200 -0.8oC NAF-S-III -20.5oC - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Typical Results Safe for property 60 56 52 48 44 40 36 32 28 24 20 16 12 8 4 1 2 3 5 6 7 9 10 11 13 14 15 17 18 19 INERGEN® Retention Threshold INERGEN® Concentration (%) HALON Concentration (%) HALON Retention Threshold HALON Concentration INERGEN® Concentration Typical Results Time (Minutes) - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Safe for the planet Ozone Depletion Potential (ODP) = 0 Global Warming Potential (GWP) = 0 Atmospheric Lifetime = 0 Composed entirely of gases present in the air we breathe - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Central Storage safe for your pocket One cylinder requires 0.07m2 (1 square foot) of storage space Cylinders can be stored up to 100m from the protected room Central Storage and selector valves can be used for multi- hazard protection - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Cylinders can be Stored 150 meters away There is always a convenient place to locate the storage bank - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Cost Saving – Central Cylinder Bank System Single Cylinder Bank Cost Saving – Central Cylinder Bank System 5 CYL 10 CYL 15 CYL Room 1 Room 2 Room 3 Selector Valves - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Cost Saving – Central Cylinder Bank System Single Cylinder Bank Cost Saving – Central Cylinder Bank System 5 CYL 10 CYL 15 CYL Room 1 Room 2 Room 3 Selector Valves - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Automatic Remote Cylinder Condition Monitoring INERGEN Gas Based System Is Nothing But Safety Measurement Used For Fire Prevention In The Event Of Fire. What Happens If Some Or All Cylinders Are Exhausted Due To Leaking Or Low Pressure. To Ensure Correct System In Place Throughout - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Automatic Remote Monitoring Automatic Remote Cylinder Condition Monitoring The manoswitch (combined pressure gauge and pressure switch) used by Fire Eater features a single pole change over switch making it possible to monitor for normal and low pressure as well as short circuitry and open circuit. The manoswitches are designed to be connected in a daisy chain, where low pressure on one manoswitch will indicate low pressure on the monitoring panel. The dual-resistor terminator (part of this kit) has to be placed on the last manoswitch in the daisy chain. In the normal position (pressure above the set point) the resistance of the circuitry is high (3K3/5K6), when pressure falls below the set point the resistance of the circuitry falls to low (680/470 ohm). - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Where Inergen is Used Worldwide Machinery Spaces Laboratories Control Rooms Telecommunication Facilities - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Where Inergen is Used Worldwide Electrical Switch Rooms Museums and Archives Computer Rooms Normally occupied areas Operation and Command Centers - Perfectly Safe for People, Property, the Planet…. and your Pocket!

Inergen, The logical choice Safe for People NO adverse effects on people. Contains a small amount of CO2 to stimulate the uptake of oxygen Does not create a fog ensuring that escape routes are always visible Safe for Property Harmless on physical assets like equipment furniture etc. Leaves no residue to clean up and does not produce any toxic by- products Safe for the Planet Inergen is as safe as the air we breathe! Easy on your Pocket Inergen will never be banned Central cylinder banking to protect multiple areas Naturally existing gases makes maintenance and refills easy 10 year Evergreen warranty takes all your problems away - Perfectly Safe for People, Property, the Planet…. and your Pocket!

------ Your Safety Is Our Commitment -------- END ------ Your Safety Is Our Commitment -------- - Perfectly Safe for People, Property, the Planet…. and your Pocket!