HW4 Problem (Use TITUS Square Ceiling MCD diffuser

Slides:



Advertisements
Similar presentations
Elementary Mechanics of Fluids
Advertisements

SUPPLY DUCT SYSTEMS (Additional information. Read sections 18.4, 18.5, & 18.6) General –The supply duct system conveys conditioned air from an AHU to the.
CHE Pumps and gas moving equipment  For the fluid flow from point to another, a driving force is needed.  The driving force may be supplied by.
Pumps and Pumping Stations
Heating and Air Conditioning I
Nonmetallic ducts (Additional information) –Fiberglass (also see section 18.5) Made of glass wool insulating material in which the stranded fiber wool.
Objectives Finish with ducts and fans Define project topics.
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Trevor Thompson Senior Project II Vermont Technical College Spring 2011.
ARCH-4372/6372 HVAC Distribution & Sizing HVAC Distribution Systems
Announcement Course Exam October 11 th (Tuesday) In class: 90 minutes long Examples are posted on the course website.
MECH 221 FLUID MECHANICS (Fall 06/07) Chapter 9: FLOWS IN PIPE
1 Lec 26: Frictionless flow with work, pipe flow.
Lesson 26 CENTRIFUGAL PUMPS
MER Design of Thermal Fluid Systems Pumps and Fans Professor Anderson Spring Term
Force 10/31. LT: I will be able to apply Newton’s law of motion Vocabulary: Coefficient of friction Static friction Kinetic friction Review Homework Finish.
Chapter 12: Fans and Building Air Distribution
Pumps and Lift Stations. Background Fluid Moving Equipment Fluids are moved through flow systems using pumps, fans, blowers, and compressors. Such devices.
The International Authority on Air System Components Fan Performance Mark Stevens Director of Laboratory Services AMCA International.
Aerodynamics Linear Motion (Moving Air ).
Fan Performance and Selection
Analysis of Axial & Centrifugal Compressors To be Selected as per Specific Speed of Applications…. P M V Subbarao Professor Mechanical Engineering Department.
Lesson 23 HEAD LOSS DEFINE the terms head loss, frictional loss, and minor losses. DETERMINE friction factors for various flow situations using the Moody.
DESIGN OF CASCADE for AXIAL FLOW COMPRESSORS
© Pritchard Introduction to Fluid Mechanics Chapter 8 Internal Incompressible Viscous Flow.
AIR FLOW IN DUCTS Shaharin Anwar Sulaiman
Introduction to Energy Management. Week/Lesson 10 Air Moving Equipment: Fans and Ducts.
Objectives Airflow in Ducts Fluid dynamic review Duct Design.
3.4 Equal friction method This method of sizing is used for supply, exhaust and return air duct system and employs the same friction lose per foot of length.
Objectives Describe room distribution basics Select diffusers
Objectives Learn about Fans Discuss: Exam (I will have an extra office hour on Monday at 8:00 am) Final Project (I need your group member lists till tomorrow).
Objectives Finish with Duct Design Review the design procedure and explain the theoretical background Diffuser Selection Answer question related to the.
Plenum Plenum design is based on Equal Static Pressure using Static Regain Most duct systems are designed to maintain Equal Friction or Equal Velocity.
Course Exam Next Thursday (April 15) 7 pm Same classroom (ECJ 7.208) 2.5-hour exam Open book open notes All problem types of questions (short but comprehensive)
Objectives - Air Distribution Systems -Diffuser selection -Duct design Reading Assignment: Chapter 18.
Objectives Air Distribution Systems -Diffuser selection -Duct design.
Duct Design Basics Lesson 4 Manual D Primer. Available Static Pressure 4.4.
Duct Design Basics Lesson 3 Calculations. Fitting losses, System Effect 3.4.
Lesson 1 Friction Chart Primer 1.3 Friction Chart.
Objectives Finish heat exchangers Air Distribution Systems
Duct Design Basics Lesson 4. Knowledge & Skills for Manual D 4.1.
Chapter 6 technology institute of HAVC from usst INDUSTRIAL VENTILATION TUTORIAL 王丽慧.
Field Trip Time: Tomorrow (Tuesday) 8 am Duration 1 hour (you will be back latest at 10 am) Location Texas State University: Round Rock
Power – Energy Relationships
System One Pumps S1-200 Centrifugal Hydraulics
Chapter 16B: FANS AND SYSTEM EFFECTS
and the like in the pipe or duct system.
Internal Incompressible
Subject Name: FLUID MECHANICS
MECH 8250 – Building Systems Winter 2015
Chapter 16 A: PUMPS AND SYSTEM EFFECTS
Design of An Axial Compressor Stage for Jet Engines
Chapter 16B: FANS AND SYSTEM EFFECTS
Maria’s Restaurant Chapter 3 Section 12
Fans – Lecture 2 Fan testing: Dr. C. L. Jones
Pumps and Lift Stations
Objectives Finish duct systems Learn about plumbing systems
Review for the Exam Should be able to do all calculations associated with lectures as well as HWs Problems may deal with context i.e. Explain how thermal.
Objectives Learn about Fans Discuss Exam Final Project.
Objectives - Learn about fans and fan curves
Objectives Finish with Duct Design Diffuser Selection
Next Class: Text 1.5 hour long Open book, open notes - Comprehensive
Objectives Duct Design AND Diffuser Selection.
Objectives Finish with Heat Exchangers
Pick up a handout from the front and complete it for bellringers
Objectives Duct Design AND Diffuser Selection.
Maria’s Restaurant Chapter 3 Section 12
Objectives Discuss Rotary Heat Exchangers
Objectives Discuss Exam Finish with Diffuser Selection
Objectives Air Distribution Systems Duct design HW4.
Presentation transcript:

HW4 Problem 18.13 (Use TITUS Square Ceiling MCD diffuser https://www.titus-hvac.com/Products/Diffusers) Problem 18.16 (The building size is 100 ft x 60 ft; use proportion to determine room sizes) Problem 18.19 Problem 18.20 Problem 18.27 (design problem)

Objectives Finish with Duct Design Learn about Fans

Example A C B Size the ducts and calculate pressure drop from - A to C - B to C A a c C b B Tabulated calculation: ……..

Local Dynamic losses Losses associated with Two methods Changes in velocity Obstructions Bends Fittings and transitions Two methods Equivalent length and loss coefficients

Conversion Between Methods

Duct design concepts Equal friction method Static pressure regain method

Equal friction method (the example)

Static pressure regain method

Fans Driving force to move air in buildings Raise pressure and produce flow Two main types: Centrifugal Axial

Relevant Fan Parameters Total pressure rise Static pressure rise Power requirement Efficiency Note ηtot does not account for motor efficiency

Balance Point

Fan Performance

Centrifugal fans

Axial Fans

Fan Laws “Approximate relationships” Given two aerodynamically similar fans, can extrapolate performance data Be very careful