Protection During Working at Heights

Slides:



Advertisements
Similar presentations
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
Advertisements

Fall Protection OSHA 29 CFR 1926, Subpart M..
Working At Heights Fall Protection
Construction Industry
Fall Protection for Construction A Survival Guide
Shipbreaking Module 4: Heavy Equipment & Material Movement 4.3 Personnel Hoist & Platforms Susan Harwood Grant Number SH F-23.
Fall Protection Systems
ABC’s of Fall Protection
Fall Protection Falls 4,628 fatal work injuries were recorded in the United States in deaths a week or 12 deaths every day 806 construction related.
Fall Protection Refresher Orientation
Safety on Call FALL PROTECTION SYSTEMS. Safety on Call WHY DO WE NEED FALL PROTECTION?
FALL PROTECTION.
Duty to Have Fall Protection Fall protection is required when one or more employees have exposure to falls of six feet or greater to the lower.
MODULE ONE – FALL PROTECTION What Causes Falls in Construction Duty to Have Fall Protection Competent Person Fall Protection Criteria for Commercial.
Copyright  Business & Legal Reports, Inc. BLR’s Safety Training Presentations Fall Protection.
By: Chou Lor, Safety Coordinator Fall Protection.
Fall Protection 1926 Subpart M – Fall Protection
Safety for Working in High Places
Stairways and Ladders 1926 Subpart X - Stairways and Ladders
Fall Protection.
GA Tech Safety and Health Consultation Program FALL PROTECTION.
Roofing Fall Protection The following presentation can be used to satisfy the training requirements of the Fall Protection Standard in the WISHA Safety.
OSHA Office of Training & Education
Fall Protection and Ladder Safety Training
OSHAX.org - The Unofficial Guide to the OSHA1 Stairways and Ladders.
Stairways and Ladders.
Walking-Working Surfaces
1 Telecom Cabling Ladder safety. 2 OSHA Office of Training & Education ation Telecom Cabling Stairways and Ladders.
Fall Protection I. Background for the Trainer:
Developed by Western Iowa Tech Community College This material was produced under a grant (SH20836SHO) from the Occupational Safety and Health Administration,
MIOSHA Const - Part 45 Fall Protection
Fall Protection and Ladder Safety Training. Course Outline  Introduction  Fall Protection  Ladder Safety  Wrap-up.
Fall Protection in the Roofing Industry
Safety for Working in High Places
FALL PROTECTION. WHY? –BECAUSE: Falls accounted for 10% of fatal work injuries in 1994 & Serious hazards can be present while above ground. –Examples:
v Falls from same level ◦ Slips ◦ Trips ◦ High frequency rate ◦ Low injury severity rate 1a.
Fall Hazards.
Fall Protection.
Copyright © Fall Protection, Subpart M.
Fall Protection.
FHM TRAINING TOOLS This training presentation is part of FHM’s commitment to creating and keeping safe workplaces. Be sure to check out all the training.
FALL PROTECTION. Duty To Have Fall Protection Protection at or above 6’ level Walking/working surfaces inspected before work begins Employees can only.
Office of Safety & Health Consultation Office of Safety & Health Consultation presents Focus Four Fall Protection in Construction Focus Four Fall Protection.
Fall Protection Training. - Falls remain the number one cause of fatalities in the construction industry. FALL PROTECTION FACT!!!
Fall Protection.
OSHA Office of Training & Education
1Fall FALL PROTECTION. 2Fall CONTENTS  Introduction  Purpose  Same Level Falls  Lower Level Falls  Fall Prevention  Summary.
Roofing Fall Protection
§1926 Subpart M Presented by: ETTA, OSH Division, Fall Protection in Construction.
FALL PROTECTION IN THE WORKPLACE. Pre-Meeting Notes Review the notes section of the slides prior to presenting Begin the meeting with: Does anyone one.
THE ABC’S OF YOUR PERSONAL FALL ARREST SYSTEM
OSHA Office of Training & Education
This presentation was created by the N.C. Department of Labor for safety and health training. §1926 Subpart M Presented by: ETTA, OSH Division,
Fall Protection for Construction
Fall Protection Sub-committee Update
Roofing fall protection
Fall Hazards.
Fall Protection.
Subpart M Fall Protection.
SMARCA Roy Brown, Safety Director
FALL PROTECTION.
Fall Protection.
FALL PROTECTION.
Fall Hazards.
Fall Protection.
Fall Protection Sub-committee Update
By: Kory Hildebrand PPE.
Fall Hazards.
10-hr. General Industry – Fall Protection
Presentation transcript:

Protection During Working at Heights Technical Services (HQ) Safety Department

Technical Services (HQ) Welcome! The reason for this Program Falls from Heights is the main cause of serious injuries Falls from Heights is the single biggest cause of deaths at sites The goal of this Program Learn when we must use fall protection equipment Learn about fall protection equipment Technical Services (HQ) Safety Department

Technical Services (HQ) What is “Working at Height” A place is at height if a person could be injured falling from it, even if it is at or below ground level. Work includes moving around at a place of work (except by a staircase in a permanent workplace) but not travel to or from place of work. Technical Services (HQ) Safety Department

Technical Services (HQ) What you must do as an employee Report any safety hazard to engineer. Avoid working at height where there is probability of falling from height. Use measures to prevent risk of fall where working at height could not be avoided. Use safety equipment properly following instructions, where other measure could not be installed. Technical Services (HQ) Safety Department

Technical Services (HQ) When is fall protection required in construction? If a worker is at three (3) metre or higher and danger of fall exists, fall protection system must be used. Places where fall protection is required at two (2) metre or less include holes, excavations, pits, shafts. Technical Services (HQ) Safety Department

Technical Services (HQ) Fall Protection Systems Preventing Falls Covers Guardrails Warning Lines Personal Fall Restraint Arresting Falls Personal Fall Arrest System Technical Services (HQ) Safety Department

Technical Services (HQ) Fall Protection Systems Covers – All covers must be able to support at least twice the load of employee, equipment and materials that may be imposed on them at any one time. Technical Services (HQ) Safety Department

Technical Services (HQ) Fall Protection Systems Guardrails – These should meet following requirements. Top rail and mid rail must be at least one-quarter inch nominal diameter. The top edge of guard rail must be 42 inch (1.07 m) +/- 3 inch (7.5 cm) above walking/working level. Mid rail should be installed at a height mid way between top rail and walking/working level. The guard rail must be capable of withstanding a force of at least 200 pounds (90.6 kilogram) applied within 2 inch (5.0 cm) of top edge in any direction. Guard rails must be surfaced to protect workers from lacerations and to prevent clothing from snagging. Technical Services (HQ) Safety Department

Technical Services (HQ) Fall Protection Systems Personal Fall Arrest System – This consists of an anchorage, connectors, a body belt or a full body harness and may include a deceleration device and life line. It should meet following requirements. Limit maximum arresting force on an employee to 1800 pounds (815.4 kilograms) when used with a body harness. Be rigged so that an employee can not free fall more than 6 feet (1.8 meters). Limit maximum deceleration distance to 3.5 feet (1.07 meters). Technical Services (HQ) Safety Department

Technical Services (HQ) Fall Protection Systems Personal Fall Arrest System Have sufficient strength to withstand twice the potential impact energy of an employee free falling a distance of 6 feet (1.8 meters). Horizontal/vertical life lines shall be designed, installed and used under the supervision of a qualified person as a part of a complete personal fall arrest system that maintains a safety factor of at least two. Life line shall be protected against being cut or abraded. On vertical life line the device used to connect to a vertical lifeline shall be capable of locking on the life line whenever an impact force is applied. Technical Services (HQ) Safety Department

Technical Services (HQ) Fall Protection Systems Personal Fall Arrest System Lanyards and vertical lifeline must have a minimum breaking strength of 5000 pounds (2265 kilograms). The anchor must support a minimum load of 2265 kilograms or be designed by a QUALIFIED person with a safety factor of two times the impact force of a person falling six feet. Technical Services (HQ) Safety Department

Technical Services (HQ) Personal fall arrest system components Energy absorbing rope lanyard Full Body Harness Technical Services (HQ) Safety Department

Technical Services (HQ) Rope Grab Fall Arrester & Life Line Made from Stainless Steel Useful for vertical & sloping movement Slides on 12 mm flexible Polyamide rope. Automatic Locking facility Technical Services (HQ) Safety Department

Technical Services (HQ) Anchorage Hooks for Safety Belts Technical Services (HQ) Safety Department

Technical Services (HQ) Life Line A Lifeline is a cable or a rope that connects to a body harness or lanyard and at least one anchorage. There are two types of Lifelines. Horizontal Lifeline. Vertical Lifeline. Technical Services (HQ) Safety Department

Technical Services (HQ) Vertical Life Line A vertical life line is attached to an overhead anchor and must be connected directly to worker’s full body harness, lanyard. It must have a minimum breaking strength of 5000 pounds (2265 kilograms). When a worker moves horizontally, a vertical life line could be hazardous due to potential for a swing fall and horizontal lifeline is recommended. Technical Services (HQ) Safety Department

Technical Services (HQ) Horizontal Life Line A flexible horizontal life line is a pliable line rigged in horizontal plane secured at each end to an anchorage. A worker is connected to the line using a personal fall arrest system that moves with the worker between the two anchorage points. It allows worker to move horizontally and reduces the hazard of dangerous swing fall that can occur if a worker moves to a location if the anchorage is no longer directly overhead. Technical Services (HQ) Safety Department

Technical Services (HQ) Horizontal Life Line Horizontal lifelines are subjected to much greater loads than vertical loads. If these are not installed correctly, horizontal lifelines may fail at anchorage points. Horizontal lifelines must be designed, installed and used by a competent person. Any load on horizontal lifeline will cause it to sag or deflect. The sag angle is a horizontal lifeline’s angle of deflection when it is subjected to a load, such as a falling worker. Reducing the sag angle (making the lifeline too tight) increases the force on the lifeline during a fall. When the sag angle is 15 degree, the force on the lifeline and anchorages subjected to load is 2:1. When sag angle is 5 degree, the force increases to about 6:1. Technical Services (HQ) Safety Department

Technical Services (HQ) Horizontal Life Line Technical Services (HQ) Safety Department

Technical Services (HQ) Safety Net Safety net openings should not be more than 15 cm on a side. Safety net must not be installed more than 30 feet (9.15 meters) below the working surface. An installed net must be able to withstand a drop test consisting of a 400 pounds (181.2 kilograms) sand bag, 30 inches (76.2 cm) in diameter, dropped from the working surface. Inspect safety nets regularly for damage. Technical Services (HQ) Safety Department

Technical Services (HQ) Retractable Wire Rope Fall Arrester Portable Multipurpose application Available length 10 M / 15 M 4 mm dia. galvanized / 5 mm Stainless steel Cable Composite anti-shock Casing Fall Arrest Peak Force less than 6 KN. Technical Services (HQ) Safety Department

Technical Services (HQ) Safe Practices for Personal fall-arrest system Don’t tie knots in rope lanyards and lifelines; knots can reduce strength by 50 percent. Don’t tie lifelines or lanyards directly to I-beams; the cutting action of beams edges can reduce the rope’s strength by 70 percent. Sag angle of the horizontal lifelines can affect arrest forces on the anchorages. Whenever you connect a lifelines; think about potential for a swing fall. Shock absorbing lanyard will elongate before arresting a fall. The fall distance includes lanyard length, deceleration distance, worker height and safety margin. Technical Services (HQ) Safety Department

Technical Services (HQ) Two ways to stop injury or death from falls Stop the worker from falling to a lower level. Technical Services (HQ) Safety Department

Technical Services (HQ) Two ways to stop injury or death from falls Stop injury/death after falling. Use personal fall arrest system Technical Services (HQ) Safety Department

Technical Services (HQ) Two ways to stop injury or death from falls Stop injury/death after falling. Safety Net (collective protection system) Technical Services (HQ) Safety Department

Technical Services (HQ) Fall Arrest or Fall Prevention? Fall Arrest Prevents deaths but may still cause injury from the arresting force or swing falls Technical Services (HQ) Safety Department

Technical Services (HQ) Fall Arrest or Fall Prevention? Fall Prevention is Better Technical Services (HQ) Safety Department

Technical Services (HQ) Total Fall Distance The distance between anchor to the activation of deceleration device + From activation of deceleration device to a complete stop = Total Fall Distance Technical Services (HQ) Safety Department

Technical Services (HQ) Total Fall Distance Technical Services (HQ) Safety Department

How Long does it take to Fall? Height (feet)/(m) 4 (1.2 m) 16 (4.8 m) 64 (19.32 m) 100 (30.48 m) 144 (43.89 m) 256 (78.02 m) 576 (175.56 m) 1000 (304.80 m) Time (second) 0.5 1.0 2.0 2.5 3.0 4.0 6.0 10.0 Technical Services (HQ) Safety Department

Technical Services (HQ) Inspecting fall arrest equipment (made from webbing or rope) Lanyards should be subject to Pre-use checks. Detailed inspections. Interim inspections. These should be carried out by competent person, to identify defects or damages that may affect safety. Technical Services (HQ) Safety Department

Technical Services (HQ) Inspecting fall arrest equipment (made from webbing or rope) Pre-use checks – These checks should be carried out visually each time, before a lanyard is used by passing it slowly through the hands. To detect small cuts of 1mm in the edges. Softening or hardening of fiber. Ingress of contaminants. A 1 mm cut in the edge of a lanyard can result in a 5 to 40% loss of strength depending upon the make of lanyard being used. Technical Services (HQ) Safety Department

Technical Services (HQ) Inspecting fall arrest equipment (made from webbing or rope) Detailed Inspections – These should be carried out periodically at minimum intervals as specified by manufacturer or at least every six months. For frequently used lanyards the inspection should be carried out every three months. Interim Inspections – These may be needed if lanyards are used in arduous environment involving welding/gas cutting operations, paints, chemicals, blasting operations, acidic/alkaline environment. Technical Services (HQ) Safety Department

Technical Services (HQ) Inspecting fall arrest equipment (made from webbing or rope) Examples of defects and damages – The following defects and damages have the potential to result in the degradation and/or weakening of the lanyard. Cuts of 1 mm or more at the edges. Surface abrasion across the face of webbing and at the webbing loops, particularly if localized. Abrasion at the edges, particularly if localized. Damage to stitching (eg cuts or abrasion). Technical Services (HQ) Safety Department

Technical Services (HQ) Inspecting fall arrest equipment (made from webbing or rope) A knot in the lanyard, other than those intended by the manufacturer. Chemical attack which can result in local weakening and softening – often indicated by flaking of the surface. There may also be a change to the color of the fiber. Heat or friction damage indicated by fibres with a glazed appearance which may feel harder than surrounding fibres. UV degradation is associated with some loss of colour and a powdery surface. Technical Services (HQ) Safety Department

Technical Services (HQ) Inspecting fall arrest equipment (made from webbing or rope) Partially deployed energy absorber (eg short pull-out of tear webbing). Contamination (eg with dirt, grit, sand etc) that may result in internal/external abrasion. Damaged or deformed fittings. Internal damage to a cable-laid rope. Technical Services (HQ) Safety Department

Technical Services (HQ) Withdrawing lanyards from Use A lanyard should be withdrawn from use and destroyed if it is thought to be defective or if there is any doubt about its safety after a pre-use check or interim inspection. A lanyard that has been used to arrest a fall should never be reused. It should be withdrawn from service immediately and destroyed. Technical Services (HQ) Safety Department

Technical Services (HQ) Use personal fall protection when working on or near Unprotected sides or edges of platforms. Walking or working on platforms which are under construction. Walking or working on temporary platforms or scaffolds. Walking or working on beams. Dangerous equipment. Excavations. Technical Services (HQ) Safety Department

Technical Services (HQ) Summary Wherever possible it is best to eliminate the need for personal fall protection by installing guardrails or covers. Employers are required to provide fall protection equipment and training on its use. Fall protection equipment should be inspected before each use for wear and damage. Fall protection system should be inspected at least twice a year by a competent person. Technical Services (HQ) Safety Department

Technical Services (HQ) You may complain that this equipment is awkward, but it’s better than taking a fall. Technical Services (HQ) Safety Department

Technical Services (HQ) Thank you Technical Services (HQ) Safety Department