T-6B On-Board Oxygen Generation System (OBOGS)

Slides:



Advertisements
Similar presentations
Installed Oxygen System
Advertisements

SECTION 11 LEVEL B SUIT OUT. SECTION 12 AIR MONITORING.
AST 473 CE 550 Citation II Systems
Cessna C500 Fuel System hello and welcome to my talk on the c500 fuel system.
Engine Systems J-52-P408 &J-52-P6/P8
Refrigeration Flow Control
Perspective SR-22 Electrical System
 Description of PressurePro System  Identify system components  Display and Operational Modes  Sensor alerts  Checking of tire pressures  Manual.
737 PNEUMATICS MENU PRINCIPAL.
AST 473 Citation II Systems Pressurization
AST 473 Cessna Citation Oxygen System Dr. Kurt Barnhart.
ECS and MINISTAB System Capt Johnson. Two vent controls are mechanically connected to flapper valves, which lock in different positions to vary the.
Indicates primary inverter is inop. Operational secondary and auxiliary inverters will Maintain power to all fixed frequency busses.
Aircraft Systems Oxygen Systems A-4N/TA-4. Aircraft Systems Oxygen System LESSON OBJECTIVES To give the TP information on the Oxygen System to include.
Product Introduction.
AccuMax Multi-Point Injection Mechanics
Hydronic Mechanical Controls
Series Operational Training. 2 Water Tank Water Pump Multiple Discharges 2000 Series Line Strainer Foam Tank Electronic Direct Injection Proportioner.
AST 473 Cessna Citation II Air Conditioning System Dr. Barnhart.
Aircraft Ice Protection Systems
B757 Review Questions.
APPROVED TRAINING MANUAL’S LESSON PLANS AND COURSEWARE STAR MARIANAS AIR, INC. Recurrent – Flight Crew Part III – Aircraft Ground Training Section 2 –
Reservoir 0.6 Gal HYDRAULICS Engine Driven Pump NWS ± 12 o 3 Gear 6 sec Doors SB 70 o Flaps 23 o / 50 o Chk Valve Filter 3500 PSI Release Helium Hyd Fl.
Settings & Adjustments. Settings & Adjustments.
Ice Protection © 2011 Tron Aviation Flight Operations and Pilot Training Program Version 3.0.
Machinery Cooling Water System Locations and Operations.
Created: 30 Aug 2015 Updated: 18 Sep 2015 T6BDriver.com
Initial Pilot Ground School
Air Line Pilots Association, International EMB 145 Oral Questions Overhead “A” Select “Slide Show” Use the space bar on your computer to advance the presentation.
UH-60 IPC/MOI CW2 JAMES THOMAS.
UH-60 HYDRAULIC SYSTEM BY: CW2 Ron Nelson.
UH-60A/L Fuel System.
T-6B On-Board Oxygen Generation System (OBOGS)
TITLE OF THE PROJECT:- AUTOMOBILE AIR CONDITIONING AIM OF THE PROJECT:- TO STUDY ABOUT AIR CONDITIONING SYSTEM OF AN AUTOMOBILE PRESENTED BY: INAMUL.
AfterSalesTraining Welcome to AfterSalesTraining.
Air Line Pilots Association, International EMB 145 Oral Questions Overhead “E” Select “Slide Show” Use the space bar on your computer to advance the presentation.
7 A/C System Components, Operation, and Service.
Initial Pilot Ground School
Air Line Pilots Association, International EMB 145 Oral Questions Center Pedestal Select “Slide Show” Use the space bar on your computer to advance the.
T-6B Electrical System Created:24 Aug 2015 Updated:30 Aug 2015 T6BDriver.com.
Electrical system : Operator station PLC display Engine under operation - Operating the unit is carried out from the Operator Station. - Two rotary switch.
General Electric T-700 Engine Overview
MENU PRINCIPAL. THIS PRESENTATION INCLUDES THE SOURCES OF AIR, THE MAJOR SYSTEM COMPONENTS AND THE WAY THE CONTROLS AND INDICATORS ARE USED TO OPERATE.
EC 130 B4 Initial Pilot Ground School Chapter 9 Hydraulic System.
AIR CONDITIONING SYSTEM. FUNCTION Air conditioning systems create a safe and comfortable environment for passengers and crews in the aircraft cabin. The.
T-6B Environmental Control System (ECS) Created:5 Sep 2015 Updated:18 Sep 2015 T6BDriver.com.
250-C20J Engine System.
ECS and MINISTAB System
Pressure Regulators KVR + NRD Presentation , Jbm - Page 1.
Automotive Heating And Air Conditioning
GROUND SERVICING OF VARIOUS SUB SYSTEMS
Brooks Expert Support Tool (BEST) Software
GROUND SERVICING OF VARIOUS SUB SYSTEMS
14 Refrigerant Recovery, Recycling, and Recharging.
MACS CPAP System Self Guided Tour.
Automotive Heating And Air Conditioning
air cycle cooling systems
Controllers and Positioners
Air Distribution Control
PA-28R-201 Systems Andy Philbin.
Digital Chart Recorder Operation
Created: 24 Aug 2015 Updated: 30 Aug 2015 T6BDriver.com
AVIATION 325 PITOT - STATIC SYSTEM VACCUM SYSTEM
Compressor Operating Instructions
Brake Hydraulic Systems
AUTOMATIC AIR-CONDITIONING SYSTEM OPERATION
T-6B On-Board Oxygen Generation System (OBOGS)
Created: 30 Aug 2015 Updated: 18 Sep 2015
Created: 24 Aug 2015 Updated: 30 Aug 2015
The Basic Bulb Bulb uses electrical current to produce light.
Presentation transcript:

T-6B On-Board Oxygen Generation System (OBOGS) Created: 5 Sep 2015 Updated: 7 Sep 2015 T6BDriver.com

(Utilize OBOGS system schematic while reviewing this slideshow) Objectives Identify components and understand operation of OBOGS (Utilize OBOGS system schematic while reviewing this slideshow)

References T-6B NATOPS Manual Section 1 On-Board Oxygen Generating System (OBOGS) Oxygen Pressure Regulator Oxygen Pressure Regulator Supply Lever Oxygen Pressure Regulator Concentration Lever Oxygen Pressure Regulator Pressure Lever Oxygen Pressure Regulator BIT Button Oxygent Pressure Regulator Flow Indicator

Lt Side P3 Port Shutoff Valve   Heat Exchanger   OBOGS System Overview OBOGS TEMP High Temp Switch   Provides each pilot with automatically regulated oxygen supply Uses conditioned bleed air from engine by pressure swing absorption using a molecular sieve Oxygen provided at a slight positive pressure Plenum provides a limited amount of oxygen in case of OBOGS failure Each cockpit has pressure regulator 200 F Condensation Drain Built In Test (BIT) -Initiated upon first activation of system -Sensor warm-up period of 3 min -OBOGS FAIL inhibited (by Monitor for concentration) -OBOGS FAIL still works for Low Pressure -At end of 3 min – OBOGS FAIL if internal failure OBOGS FAIL Low Press Switch     OBOGS (Hot Bat Bus) BIT Water Separator OBOGS FAIL Pressure Regulator/Shutoff Valve Internal Failure OBOGS FAIL Monitor Low Concentration Concentrator Composition Controller Non-return Valve Initiated Built In Test (I-BIT) -Initiated by BIT on regulator after 3 min warm-up -Verification that OBOGS sensor & OBOGS FAIL work -Use: --Momentarily push button --Oxy concentration purposely drops --Get OBOGS FAIL from Monitor (for concentration) --Warning extinguishes within 2 min Plenum     OXYGEN FLOW BIT SUPPLY   • EMERGENCY   •NORMAL ON   • NORMAL OXYGEN • TEST MASK • MAX OFF Cockpit Specific Affects Both Cockpits < 15K: 25 – 70% > 15K: 45 – 95% MAX: 95% Cockpit Specific (Turns on OBOGS & Opens P3 Shutoff Valve)

Accessory Section (right side) Gas Generation Section (left side) Bleed Air Supply Lt Side P3 Port Left Side P3 Port Tap off compressor section of engine Supplies engine bleed air to OBOGS only Shutoff Valve Controlled by supply lever on Oxygen Pressure Regulator Allows the flow of bleed air into the OBOGS Shutoff Valve   Accessory Section (right side) Gas Generation Section (left side) Shutoff Valve Supply Lever Lt Side P3 Port

Heat Exchanger Cools bleed air for use in OBOGS Lt Side P3 Port Heat Exchanger Shutoff Valve   Cools bleed air for use in OBOGS Divided into 2 sections: Cooling for anti-G/canopy seal/OBOGS (left side) Cooling for all other ECS functions Air directed to heat exchanger by cooling air inlet duct on nose On ground, flap covers inlet duct and WOW switch activates blower to push air across heat exchanger Heat Exchanger   Cooling Air Inlet OBOGS Line Heat Exchanger

Supply Line High Temperature Switch Condensation Drain Lt Side P3 Port High Temperature Switch Measures temperature in OBOGS ducting A OBOGS TEMP caution illuminates if temperature exceeds 200°F in OBOGS ducting Indicates heat exchanger not sufficiently cooling bleed air Condensation Drain Actually multiple drains in the system (3 total) Removes moisture from lines as a direct result of cooling through heat exchanger Low Pressure Switch Senses bleed air pressure upstream of the OBOGS concentrator A OBOGS FAIL warning illuminates to indicate low bleed air pressure in system OBOGS Malfunction procedures requires advancing the PCL to see if warning will extinguish Shutoff Valve   Heat Exchanger   OBOGS TEMP High Temp Switch   200 F Condensation Drain OBOGS FAIL Low Press Switch  

OBOGS Unit Located in left avionics bay (and labeled OXYGEN) Lt Side P3 Port Located in left avionics bay (and labeled OXYGEN) Powered by Hot Battery Bus Activation and functional settings controlled by Oxygen Pressure Regulator (either cockpit) Extracts oxygen from conditioned bleed air by pressure swing absorption using a molecular sieve Oxygen stored in Plenum and pushed to pilots at a low positive pressure Internally: Shutoff Valve Composition Controller Concentrator Monitor Shutoff Valve   Heat Exchanger   OBOGS TEMP High Temp Switch   200 F Condensation Drain OBOGS FAIL Low Press Switch   Left Avionics Bay   OBOGS (Hot Bat Bus) OBOGS FAIL Internal Failure An OBOGS FAIL warning illuminates to indicate internal failure of system OBOGS Unit

Pressure Regulator/Shutoff Valve Composition Controller OBOGS Unit Lt Side P3 Port Water Separator Internal system to actively remove water from bleed air Drains water to external vent Pressure Regulator/Shutoff Valve Controlled by supply lever on regulator Turning supply lever on in either cockpit opens valve and allows oxygen production Concentrator Sets oxygen concentration as selected by concentration lever on regulator Concentration is based off of current altitude When concentration levers are in NORMAL: Oxygen concentration is 25% – 70% for altitudes up to 15,000 ft MSL Oxygen concentration is 45% - 95% for altitudes above 15,000 ft MSL When either concentration lever is in MAX: OBOGS supplies highest possible oxygen concentration to both regulators 95% oxygen & 5% inert gas Maximum concentration light (green) illuminates on regulator Composition Controller Controls the gas composition (mixture) of the product Monitor Monitors composition and concentration of air being created An OBOGS FAIL warning illuminates to indicate low oxygen concentration from the system Shutoff Valve   Heat Exchanger   OBOGS TEMP High Temp Switch   200 F Condensation Drain OBOGS FAIL Low Press Switch     OBOGS (Hot Bat Bus) BIT Water Separator OBOGS FAIL Pressure Regulator/Shutoff Valve Internal Failure OBOGS FAIL Monitor Low Concentration Concentrator Composition Controller Non-return Valve OBOGS Fail Warning Summary An OBOGS FAIL warning illuminates to indicate: Low bleed air pressure Low oxygen concentration Internal system failure You can only affect the failure due to low pressure by advancing the PCL!

Pressure Regulator/Shutoff Valve Composition Controller OBOGS Unit Lt Side P3 Port Built-in-Test (BIT) Power up BIT to check system on initial start up System enters a 3 minute, sensor warm-up period when first activated The OBOGS FAIL warning inhibited during the warm-up period (3 minutes) for concentration & internal failure (still works for low pressure) At end of BIT system will activate OBOGS FAIL warning if internal failure Warning remains illuminated until failure is cleared by the self-test or by resetting regulators Initiated Built-in-Test (I-BIT) Use button on regulator to initiated the BIT at times other than the power up BIT Provides verification that OBOGS monitor is working along with fail warning Momentarily pushing button: Opens valve in concentrator allowing ambient air into the concentration monitor Concentration drops below normal (20-30 seconds) The OBOGS FAIL warning illuminates for low concentration Once valve closes and concentration returns, warning extinguishes (within 2 minutes) Operations with mask down or loose fitting: May induce OBOGS FAIL warning If fault does not automatically clear after securing mask, perform I-BIT check No further action required if I-BIT check passes Shutoff Valve   Heat Exchanger   OBOGS TEMP High Temp Switch   200 F Condensation Drain Built In Test (BIT) -Initiated upon first activation of system -Sensor warm-up period of 3 min -OBOGS FAIL inhibited (by Monitor for concentration) -OBOGS FAIL still works for Low Pressure -At end of 3 min – OBOGS FAIL if internal failure OBOGS FAIL Low Press Switch     OBOGS (Hot Bat Bus) BIT Water Separator OBOGS FAIL Pressure Regulator/Shutoff Valve Internal Failure OBOGS FAIL Monitor Low Concentration Concentrator Composition Controller Non-return Valve Initiated Built In Test (I-BIT) -Initiated by BIT on regulator after 3 min warm-up -Verification that OBOGS sensor & OBOGS FAIL work -Use: --Momentarily push button --Oxy concentration purposely drops --Get OBOGS FAIL from Monitor (for concentration) --Warning extinguishes within 2 min

Pressure Regulator/Shutoff Valve Composition Controller OBOGS Unit Lt Side P3 Port Provides a limited supply of oxygen in the event OBOGS fails Duration of Plenum depends on: Cockpit pressurization Aircraft pressure altitude Pilot regulator settings Pilot demand Shutoff Valve   Heat Exchanger   OBOGS TEMP High Temp Switch   200 F Condensation Drain Built In Test (BIT) -Initiated upon first activation of system -Sensor warm-up period of 3 min -OBOGS FAIL inhibited (by Monitor for concentration) -OBOGS FAIL still works for Low Pressure -At end of 3 min – OBOGS FAIL if internal failure OBOGS FAIL Low Press Switch     OBOGS (Hot Bat Bus) BIT Water Separator OBOGS FAIL Pressure Regulator/Shutoff Valve Internal Failure OBOGS FAIL Monitor Low Concentration Concentrator Composition Controller Non-return Valve Initiated Built In Test (I-BIT) -Initiated by BIT on regulator after 3 min warm-up -Verification that OBOGS sensor & OBOGS FAIL work -Use: --Momentarily push button --Oxy concentration purposely drops --Get OBOGS FAIL from Monitor (for concentration) --Warning extinguishes within 2 min Plenum  

Pressure Regulator Lt Side P3 Port Panel-mounted regulator on right side console of each cockpit Controls OBOGS electrical power and oxygen flow for respective cockpit Can be “gang-loaded” in event of hypoxia symptoms or loss of cabin pressure (ON/MAX/EMERGENCY) Shutoff Valve   Heat Exchanger   OBOGS TEMP High Temp Switch   200 F Condensation Drain Built In Test (BIT) -Initiated upon first activation of system -Sensor warm-up period of 3 min -OBOGS FAIL inhibited (by Monitor for concentration) -OBOGS FAIL still works for Low Pressure -At end of 3 min – OBOGS FAIL if internal failure OBOGS FAIL Low Press Switch     OBOGS (Hot Bat Bus) BIT Water Separator OBOGS FAIL Oxygen Pressure Regulator (front cockpit) Pressure Regulator/Shutoff Valve Internal Failure OBOGS FAIL Monitor Low Concentration Concentrator Composition Controller Non-return Valve Initiated Built In Test (I-BIT) -Initiated by BIT on regulator after 3 min warm-up -Verification that OBOGS sensor & OBOGS FAIL work -Use: --Momentarily push button --Oxy concentration purposely drops --Get OBOGS FAIL from Monitor (for concentration) --Warning extinguishes within 2 min Plenum     OXYGEN FLOW BIT SUPPLY   • EMERGENCY   •NORMAL ON   • NORMAL OXYGEN • TEST MASK • MAX OFF

Pressure Regulator Supply Lever Concentration Lever Lt Side P3 Port Supply Lever Controls power to OBOGS & oxygen flow to respective regulator ON Opens P3 Shutoff Valve (left side) Opens Regulator Shutoff Valve (internally) for respective regulator OFF Cuts OBOGS power & oxygen flow to respective regulator Both regulator supply levers must be OFF to disable the OBOGS system Concentration Lever Sets oxygen concentration Concentration is based off of current altitude When concentration levers are in NORMAL: Oxygen concentration is 25% – 70% for altitudes up to 15,000 ft MSL Oxygen concentration is 45% - 95% for altitudes above 15,000 ft MSL When either concentration lever is in MAX: OBOGS supplies highest possible oxygen concentration to both regulators 95% oxygen & 5% inert gas Maximum concentration light (green) illuminates on regulator Shutoff Valve   Heat Exchanger   OBOGS TEMP High Temp Switch   200 F Condensation Drain Built In Test (BIT) -Initiated upon first activation of system -Sensor warm-up period of 3 min -OBOGS FAIL inhibited (by Monitor for concentration) -OBOGS FAIL still works for Low Pressure -At end of 3 min – OBOGS FAIL if internal failure OBOGS FAIL Low Press Switch     OBOGS (Hot Bat Bus) BIT Water Separator OBOGS FAIL Pressure Regulator/Shutoff Valve Internal Failure OBOGS FAIL Monitor Low Concentration Concentrator Composition Controller Non-return Valve Initiated Built In Test (I-BIT) -Initiated by BIT on regulator after 3 min warm-up -Verification that OBOGS sensor & OBOGS FAIL work -Use: --Momentarily push button --Oxy concentration purposely drops --Get OBOGS FAIL from Monitor (for concentration) --Warning extinguishes within 2 min Plenum   BIT Button Flow Indicator   OXYGEN FLOW BIT SUPPLY   • EMERGENCY   •NORMAL ON   • NORMAL OXYGEN • TEST MASK • MAX OFF Cockpit Specific Affects Both Cockpits < 15K: 25 – 70% > 15K: 45 – 95% MAX: 95% Cockpit Specific (Turns on OBOGS & Opens P3 Shutoff Valve) Pressure Lever Concentration Lever Supply Lever

Pressure Regulator Pressure Lever BIT Button Flow Indicator Lt Side P3 Port Pressure Lever EMERGENCY – Provides pilot with positive pressure oxygen flow needed during emergencies NORMAL – Provides a slight positive pressure of oxygen flow TEST MASK – Provides highly pressurized flow to check face-to-mask seal BIT Button Pressing momentarily activates an I-BIT Flow Indicator Provides visual indication of oxygen flow through regulator Each inward breath activates a flow indicator (white) Can indicate leak in mask or hose assembly Shutoff Valve   Heat Exchanger   OBOGS TEMP High Temp Switch   200 F Condensation Drain Built In Test (BIT) -Initiated upon first activation of system -Sensor warm-up period of 3 min -OBOGS FAIL inhibited (by Monitor for concentration) -OBOGS FAIL still works for Low Pressure -At end of 3 min – OBOGS FAIL if internal failure OBOGS FAIL Low Press Switch     OBOGS (Hot Bat Bus) BIT Water Separator OBOGS FAIL Pressure Regulator/Shutoff Valve Internal Failure OBOGS FAIL Monitor Low Concentration Concentrator Composition Controller Non-return Valve Initiated Built In Test (I-BIT) -Initiated by BIT on regulator after 3 min warm-up -Verification that OBOGS sensor & OBOGS FAIL work -Use: --Momentarily push button --Oxy concentration purposely drops --Get OBOGS FAIL from Monitor (for concentration) --Warning extinguishes within 2 min Plenum   BIT Button Flow Indicator   OXYGEN FLOW BIT SUPPLY   • EMERGENCY   •NORMAL ON   • NORMAL OXYGEN • TEST MASK • MAX OFF Cockpit Specific Affects Both Cockpits < 15K: 25 – 70% > 15K: 45 – 95% MAX: 95% Cockpit Specific (Turns on OBOGS & Opens P3 Shutoff Valve) Pressure Lever Concentration Lever Supply Lever

Pressure Regulator Anti-Suffocation Valve Lt Side P3 Port Anti-Suffocation Valve Positioned where oxygen hose connected to panel Ensures pilot can breath in event OBOGS fails Shutoff Valve   Heat Exchanger   OBOGS TEMP High Temp Switch   200 F Condensation Drain Built In Test (BIT) -Initiated upon first activation of system -Sensor warm-up period of 3 min -OBOGS FAIL inhibited (by Monitor for concentration) -OBOGS FAIL still works for Low Pressure -At end of 3 min – OBOGS FAIL if internal failure OBOGS FAIL Low Press Switch     OBOGS (Hot Bat Bus) BIT Water Separator OBOGS FAIL Pressure Regulator/Shutoff Valve Internal Failure OBOGS FAIL Monitor Low Concentration Concentrator Composition Controller Non-return Valve Initiated Built In Test (I-BIT) -Initiated by BIT on regulator after 3 min warm-up -Verification that OBOGS sensor & OBOGS FAIL work -Use: --Momentarily push button --Oxy concentration purposely drops --Get OBOGS FAIL from Monitor (for concentration) --Warning extinguishes within 2 min Plenum     OXYGEN FLOW BIT Anti-Suffocation Valve SUPPLY   • EMERGENCY   •NORMAL ON   • NORMAL OXYGEN • TEST MASK • MAX OFF Cockpit Specific Affects Both Cockpits < 15K: 25 – 70% > 15K: 45 – 95% MAX: 95% Cockpit Specific (Turns on OBOGS & Opens P3 Shutoff Valve)

Conclusion Identified components and described operations of OBOGS Lt Side P3 Port Shutoff Valve   Conclusion Heat Exchanger   Identified components and described operations of OBOGS OBOGS TEMP High Temp Switch   200 F Condensation Drain Built In Test (BIT) -Initiated upon first activation of system -Sensor warm-up period of 3 min -OBOGS FAIL inhibited (by Monitor for concentration) -OBOGS FAIL still works for Low Pressure -At end of 3 min – OBOGS FAIL if internal failure OBOGS FAIL Low Press Switch     OBOGS (Hot Bat Bus) BIT Water Separator OBOGS FAIL Pressure Regulator/Shutoff Valve Internal Failure OBOGS FAIL Monitor Low Concentration Concentrator Composition Controller Non-return Valve Initiated Built In Test (I-BIT) -Initiated by BIT on regulator after 3 min warm-up -Verification that OBOGS sensor & OBOGS FAIL work -Use: --Momentarily push button --Oxy concentration purposely drops --Get OBOGS FAIL from Monitor (for concentration) --Warning extinguishes within 2 min Plenum   Abnormal OBOGS Scenarios located in Procedures Section/EPs   OXYGEN FLOW BIT SUPPLY   • EMERGENCY   •NORMAL ON   • NORMAL OXYGEN • TEST MASK • MAX OFF Cockpit Specific Affects Both Cockpits < 15K: 25 – 70% > 15K: 45 – 95% MAX: 95% Cockpit Specific (Turns on OBOGS & Opens P3 Shutoff Valve)