Process Monitors and Controllers

Slides:



Advertisements
Similar presentations
TPS… was established in is Certified to ISO9001:2000 by SGS. Manufacturers of Instrumentation for pH, Redox, Specific Ions, Conductivity, Salinity,
Advertisements

PXR Series Digital Temperature Controllers Leader for Temperature Controllers.
… for Combustible Gas Detection S4000C Intelligent Sensors..
ProMinent Product Overview
 lpha-2000 Series Process Controllers u  lpha pH/ORP 2000 u  lpha CON 2000 u  lpha DO 2000 Eutech Instruments.
Company Confidential © 2005 All Rights Reserved. What is it? State-of-the-art: microprocessor-based, wall-mount gas monitor Easy installation and operation:
Paddlewheel Flow Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Remote Monitoring and Management Solutions ®
Application Types Variable Torque Constant Torque.
Single-Loop PID Controllers All Watlow single-loop auto-tuning temperature and time/temperature profiling controllers are available in 1/32, 1/16, 1/8.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
E VERY L IFE H AS A P URPOSE… Chillgard ® L Series Refrigerant Monitors.
Experts in Chem-Feed and Water Treatment Business Unit Measuring and Control Technology M&C Packages for the year 2015 Valid from 1 st January 2015 Rev.
Experts in Chem-Feed and Water Treatment Chlorine Chemistry.
RP-2000 Series Deluge & Agent Releasing Panels
Experts in Chem-Feed and Water Treatment ProMinent Fluid Controls, Inc General Product Overview.
Electromagnetic Flowmeters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Experts in Chem-Feed and Water Treatment An Overview of Possibilities Dulcometer Disinfection Controller ( DDC )
Experts in Chem-Feed and Water Treatment Robinson & Associates, Inc. Indianapolis, IN Ken Sobbe City of Lafayette, IN Columbian Park Reservoir Residual.
A new class in PC Data Acquisition Delphin Technology AG Felix Ottofuelling V5.0.
1 HD SIGNAL CONDITIONER SERIES THERMOCOUPLE TRANSMITTER MODEL HD-TC MODEL & SUFFIX CODE SELECTION HD-TC MODEL ■ Output1 signal ■ Output2 signal Availability.
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
Experts in Chem-Feed and Water Treatment Handheld Photometer for Calibration of Sensors  Basics photometry  Portable photometer  Overview photometer.
Motor-driven pumps  Sigma/ 1  Sigma/ 2  Sigma/ 3.
1 HD SIGNAL CONDITIONER SERIES POWER DISTRIBUTOR TRANSMITTER MODEL HD-IPC MODEL & SUFFIX CODE SELECTION HD-IPC MODEL ■ Input signal ■ Output1 signal ■
ProMinent Fluid Controls, Inc.
E VERY L IFE H AS A P URPOSE… 9010 / 9020 Controller.
Water. What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured application software.
1 HD SIGNAL CONDITIONER SERIES SAMPLE HOLD TRANSMITTER MODEL HD-SHC MODEL & SUFFIX CODE SELECTION HD-SHC MODEL ■ Output2 signal Availability as Output1.
CUE – Make Any Pump an E-Pump
Our Controllers MegaTron MegaTron Multiple System Capability Multiple System Capability Internet Communication Internet Communication Conductivity.
Series RHP Temperature and Humidity Transmitter The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential.
Water Horner APG, LLC June 4, What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured.
IC Controls Quality Water Solutions for pH pH / ORP Conductivity Dissolved Oxygen Chlorine Standards R1.0 © 2004 IC CONTROLS Concerns.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Preferred Instruments a division of Preferred Utilities Mfg. Corp. Plant Wide Controller (PWC) Overview.
Ashan Perera Senior Design Project - Electronic System for Remote Water Quality Monitoring.
Photo size is: Versatronic
WELCOME TO ASHRAE 2012 CHICAGO DISTRIBUTOR BREAKFAST MEETING
Output Devices Device that accepts data from a computer and translates them into a form suitable for outside world. Output Soft Copy Output Hard Copy.
VARLOGIC NRC12 Varmetric Controller
C1300 advanced circular chart recorder
WELCOME TO ASHRAE 2011 LAS VEGAS DEALER BREAKFAST MEETING
Kontrol Series K800 K502 K500 K100 K200 K40.
EMSA 22 Lab Module 1 Field Equipment Calibration
BioTector Diagnostic Download
CLOSED-LOOP MOTOR SPEED SENSOR & CONTROLLER
HD SIGNAL CONDITIONER SERIES POTENTIOMETER TRANSMITTER
Hemodialysis Lecture 3.
HD SIGNAL CONDITIONER SERIES
USonic-R™ Remote 2-Channel System
Creative solutions for water management for Irrigation Control Systems
LDA Large Display for Analog Inputs
Creative solutions for water management with Irrigation Smart Control Systems
Enclosed Parking Ventilation 1 EK Engineering (India) CO/NO2 detection, Fan Control and automation System E: Mobile:
Industrial Instrumentation: Transmitters
PH Scale.
HD SIGNAL CONDITIONER SERIES ISOLATED SIGNAL TRANSMITTER
CHAPTER 2 TERMINOLOGY.
NSA-7000 Stylish flush mount Network Sensors
How to: Walchem W600 Calibration Introduction Calibration Overview
Magnetrol Eclipse Radar
How to: Walchem W600 Calibration Introduction Calibration Overview
Customer Presentation
Input-Output-Process Demo
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
Accelerator PSS Radiation Monitoring
COOLING WATER TREATMENT CONTROLLER
GasGard 100 Control System
Presentation transcript:

Process Monitors and Controllers The ProMinent DULCOMETER series combines a process monitor (analyzer) with automatic control capabilities for nearly any water treatment process. The series includes: D1C single variable controllers D2C dual variable controllers ProMinent 11/10/2018 ProMinent Fluid Controls

Process Monitors & Controllers ProMinent DULCOTEST sensors measure the process and the controller displays the value on a large LCD screen Control outputs can operate various control devices to keep the process within control limits using proportional or PID control action Alarm relays are available for fault annunciation Analog outputs are available for recording the measured value Features/options are selectable by identity code 11/10/2018 ProMinent Fluid Controls

ProMinent Fluid Controls Mounting Options Ident Code Option W Wall Mount, NEMA 4X Enclosure P Panel Mount, 96 x 96 mm cutout 11/10/2018 ProMinent Fluid Controls

D1C Measured Variable Options Ident Code Option Range P pH 0-14 R Redox/ORP 0 - 999 mV C Chlorine 0 - 50 ppm L Conductivity 0-20,000 mS/cm Z Ozone 0-2 ppm D Chlorine Dioxide 0-10 ppm T Temperature 32-212 deg. F A Peracetic Acid 0-2000 ppm H Hydrogen Peroxide 0-2000 ppm S Standard Analog Signal 0-20 mA I Chlorite 0-2 ppm 11/10/2018 ProMinent Fluid Controls

ProMinent Fluid Controls D2C Measured Variables Ident Code Option Range PC Chlorine/pH 0-0.5/2/10/20ppm 0-14 pH PR Redox(ORP)/pH 0 - 999 mV PP pH/pH 0-14 pH CC Free/Total Cl 0-100 ppm PD pH/Chlorine Dioxide 0-20 ppm 11/10/2018 ProMinent Fluid Controls