Goals of the Workshop The Development of Large-Area Psec TOF Systems

Slides:



Advertisements
Similar presentations
Bandwidths of Transmission Line Anodes Jean-Francois GENAT LPNHE Paris LAPPD Workshop, Chicago, April 26th 2011.
Advertisements

1 Continuous Scintillator Slab with Microchannel Plate PMT for PET Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat 2, Fukun Tang 2,
Recent news about SiPM based applications R&D in DESY Nicola D’Ascenzo University of Hamburg - DESY.
Chapter 8 Planar Scintigaraphy
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
DEVELOPMENT OF A READOUT SYSTEM FOR LARGE SCALE TIME OF FLIGHT SYSTEMS WITH PICOSECOND RESOLUTION Considerations and designs for a system of tdc’s with.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
Pico-second Timing Hardware Workshop Sponsored by: High Energy Physics Division at ANL Enrico Fermi Institute, University of Chicago Organization committee:
Solid State Detectors- 5 T. Bowcock 2 Schedule 1Position Sensors 2Principles of Operation of Solid State Detectors 3Techniques for High Performance Operation.
Large Area, High Speed Photo-detectors Readout Jean-Francois Genat + On behalf and with the help of Herve Grabas +, Samuel Meehan +, Eric Oberla +, Fukun.
Timing Properties of T0 Detectors At PHOBOS Saba Zuberi, Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek Skulski University of Rochester.
Development of Picosecond-Resolution Large-Area Time-of-Flight Systems C. Ertley 2, J. Anderson 1, K.Byrum 1, G.Drake 1, H.Frisch 2, J. Genat 2, H. Sanders.
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
Planar scintigraphy produces two-dimensional images of three dimensional objects. It is handicapped by the superposition of active and nonactive layers.
10 Picosecond Timing Workshop 28 April PLANACON MCP-PMT for use in Ultra-High Speed Applications.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
Lens ALens B Avg. Angular Resolution Best Angular Resolution (deg) Worst Angular Resolution (deg) Image Surface Area (mm 2 )
The BTeV Tracking Systems David Christian Fermilab f January 11, 2001.
Semiconductor detectors
Peter Križan, Ljubljana March 17, 2006 Super B Workshop, Frascati Peter Križan University of Ljubljana and J. Stefan Institute Aerogel RICH and TOP: summary.
May 31, 2008 SuperB PID sessionMarko Starič, Ljubljana Marko Starič J. Stefan Institute, Ljubljana Report on hardware tests and MC studies in Ljubljana.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
Photodetection EDIT EDIT 2011 N. Dinu, T. Gys, C. Joram, S. Korpar, Y. Musienko, V. Puill, D. Renker 1 Micro Channel plate PMT (MCP-PMT) Similar to ordinary.
HEALTH Novel MR-compatible PET detectors for simultaneous PET/MRI imaging FP7-HEALTH-2009-single-stage The focus should be to develop novel.
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
MINERvA Main INjector ExpeRiment for -A is the symbol for the neutrino. The beam that is sent to MINERvA is made out of neutrinos. In chemistry, an A stands.
1 Performance of a Magnetised Scintillating Detector for a Neutrino Factory Scoping Study Meeting Rutherford Appleton Lab Tuesday 25 th April 2006 M. Ellis.
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
M. Garcia-Sciveres July 2002 ATLAS A Proton Collider Detector M. Garcia-Sciveres Lawrence Berkeley National Laboratory.
Jean-François Genat Fast Timing Workshop June 8-10th 2015 FZU Prague Timing Methods with Fast Integrated Technologies 1.
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
TORCH IOP meeting Manchester March 31, 2015 TORCH Maarten van Dijk On behalf of the TORCH collaboration (CERN, University of Oxford,
TORCH – a Cherenkov based Time-of- Flight Detector Euan N. Cowie on behalf of the TORCH collaboration E N Cowie - TORCH - TIPP June 2014.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
- Herve Grabas - Ecole Superieure d’Electicite 1 Internship presentation - University of Chicago – 3 sept
PROJECT X PHYSICS STUDY WORKSHOP (PXPS 2012) Working Group on Time of Flight Conveners: Mike Albrow (FNAL) & Bob Wagner (ANL) New directions in fast timing:
Page Detector and Electronics R&D for picosecond resolution, single photon detection and imaging J.S. MilnesPhotek Ltd T.M. ConneelyUniversity.
1Jean-Francois Genat on behalf of the LAPPD collaboration (
Fabio, Francesco, Francesco and Nicola INFN and University Bari
Simulation of the Time Response of a VPT
Detector building Notes of our discussion
HPS: R&D issues Krzysztof Piotrzkowski (UCLouvain/CERN)
Idee per lo sviluppo del Charge Identifier
Grid Pix Field Simulations and precision needed for a module
Development of Large-Area Photo-detectors:
Image quality and Performance Characteristics
IMAGE ORTHICON.
Multigap Resistive Plate Chambers (MRPC)
The Development of Large-Area Psec-Resolution TOF Systems
Would Psec TOF Be Useful To LHCb?
The Development of Large-area Picosecond-resolution Detectors
The Development of Large-area Picosecond-resolution Detectors
Directional Optical Module Integration
Time-of-flight with LAPPD MCP-PMTs & MRPC
The Development of Ultra-fast Timing and the Application of HEP Technologies to Biomedical Imaging: Chin-Tu Chen, Chien-Min Kao, Jeffrey Souris, Qingguo.
The Development of Large-Area Psec-Resolution TOF Systems
Progress on the development of a low-cost fast-timing microchannel plate photodetector Junqi Xie1, Karen Byrum1, Marcel Demarteau1, Joseph Gregar1, Edward.
2nd Photocathode Workshop
The New Readout Electronics for the SLAC Focusing DIRC Prototype (SLAC experiment T-492 ) L. L. Ruckman, G. S. Varner Instrumentation Development Laboratory.
Jean-Francois Genat, Herve Grabas, Eric Oberla August 2d 2010
Enrico Fermi Institute and Physics Dept
Latest Results from T979: PSec Time-of-flight
The Development of Large-Area Psec-Resolution TOF Systems
Variable distance from beam.
Electronics for the PID
Large-Area Micro-pore Photo-sensors
PHYS 3446 – Lecture #17 Wednesday ,April 4, 2012 Dr. Brandt
Performance test of a RICH with time-of-flight information
Computed Tomography (C.T)
Presentation transcript:

Goals of the Workshop The Development of Large-Area Psec TOF Systems Henry J. Frisch Enrico Fermi Institute and Physics Dept University of Chicago 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne OUTLINE Goals of workshop A little history of the project: why picosec, and why `large-area’? (This is the 7th Workshop!) Description of concept- straw plan for concreteness, slings and arrows, education Specific Questions to be answered. 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Create/connect a community to work on large-area photo-devices, especially those in material science, surface chemistry, photo-processes. 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Identify/collect technical details; find and understand state-of-the-art; identify facilities and resources 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Identify and describe possible `show-stoppers’ on the path(s) to large-area photo-detectors; assess risk of steps on path; Answer the question “Is there a reason why this won’t work?” 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Add resources and knowledge (i.e. people) to the growing collaboration working on the proposal; (we need a first draft very soon!) 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Modus Operandi so far In Nov. 2005, we had our 1st workshop- idea was to invite folks working or interested in related subjects- didn’t know many (most) of them Have developed tools and knowledge- also contact with pioneers and practictioners (Ohshima, Howorth, Va’vra,…; Breton, Delanges, Ritt, Varner) Development clearly too big for one group- devices, electronics, applications- have worked collaboratively with each other, national labs (see talks by Karen, Andrew,Jerry,…), and industry (Burle/Photonis, Photek, IBM,…)-believe we have now solved the front-end electronics problem. Now want to extend this inclusive model of creating a community into the device itself- hence this highly focused workshop. 9/22/2018 Goals of the Workshop; Argonne

Motivation, a little history- Needs: HEP colliders, neutrino detectors, medical imaging (e.g. PET-TOF), accelerator diagnostics, truck/container scanners, … Three key developments since the 60’s may allow us to rethink the possibilities: nano/material science, fast, cheap, low-power many-channel electronics, and powerful computation for simulation Since the first workshop we have developed a readout scheme that is relatively insensitive to size- does not scale as area. Allows very large area detectors, so new applications. Can optimize parameters for different applications based on time, space resolution, occupancy, geometry, and cost- however there are common features. 9/22/2018 Goals of the Workshop; Argonne

An Explanation of what follows I’ve been driven by wanting to follow flavor-flow in colliders- most of our work has been focused on that geometry- light made in window by a relativistic particle, ~30 photo-electrons, goal of <= 1 psec timing. You’ll see most results for this regime- have to scale back to single photons (Jerry Va’vra is a notable exception) However, this path has led us to solving the electronics problem for large-area detectors- the solution for timing turns out to solve the problems of readout for large areas (capacitance, among other things). Note- good time and space resolution come naturally in this design- get 3D (`tomographic’) info by design. (time resolution IS space resolution- key point). 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne GOAL: to Develop Large-Area Photo-detectors with Psec Time and mm SpaceResolution Too small- can go larger- (But how does multiplication work- field lines?) From Argonne MSD ALD web page- can we make cheap (relatively) ultra-fast planar photo-detector modules? 9/22/2018 Goals of the Workshop; Argonne

Characteristics we need Feature size <~ 300 microns (= 1 psec at c) Homogeneity (ability to make uniform large-area- think amorphous semicndtr solar-panel) Fast rise-time and/or constant signal shape Lifetime/robustness/simplicity Cost/unit-area << that for photo-multipliers 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Design Goals Colliders: ~ 1 psec resolution, < 100K$/m2 Neutrino H2O: ~100 psec resolution, < 1K$/m2 PET: ~ 30 psec resolution, < 20% of crystal cost Micro-photograph of Burle 25 micron tube- Greg Sellberg (Fermilab)- ~2M$/m2- not including readout 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Proof of Principle Camden Ertley results using ANL laser-test stand and commercial Burle 25-micron tube- lots of photons (note- pore size may matter less than current path!- we can do better with ALD custom designs (transmission lines)) 9/22/2018 Goals of the Workshop; Argonne

`Photo-multiplier in a Pore’ Idea is to build a PMT structure inside each pore- have a defined dynode chain of rings of material with high secondary emissivity so that the start of the shower has a controlled geometry (and hence small TTS) One problem is readout- how do you cover a large area and preserve the good timing? Proposed solution- build anode into pores, capacitively couple into transmission lines to preserve pulse shape. 9/22/2018 Goals of the Workshop; Argonne

Large-area Micro-Channel Plate Panel “Cartoon” N.B.- this is a `cartoon’- working on workable designs-join us… Front Window and Radiator Photocathode Pump Gap High Emissivity Material Low Emissivity Material `Normal’ MCP pore material Gold Anode 50 Ohm Transmission Line Rogers PC Card 9/22/2018 Goals of the Workshop; Argonne Capacitive Pickup to Sampling Readout

Get position AND time Anode Design and Simulation(Fukun Tang) Transmission Line- readout both ends=> pos and time Cover large areas with much reduced channel account. 9/22/2018 Goals of the Workshop; Argonne

Photonis Planicon on Transmission Line Board Couple 1024 pads to strip-lines with silver-loaded epoxy (Greg Sellberg, Fermilab). 9/22/2018 Goals of the Workshop; Argonne

Comparison of measurements (Ed May and Jean-Francois Genat and simulation (Fukun Tang) Transmission Line- simulation shows 3.5GHz bandwidth- 100 psec rise (well-matched to MCP) The time difference yields a velocity of 64ps/cm against 68ps predicted

Scaling Performance to Large Area Anode Simulation(Fukun Tang) 48-inch Transmission Line- simulation shows 1.1 GHz bandwidth- still better than present electronics. 9/22/2018 Goals of the Workshop; Argonne

Front-end Electronics Critical path item- probably the reason psec detectors haven’t been developed We had started with very fast BiCMOS designs- IBM 8HP-Tang designed two (really pretty) chips Realized that they are too power-hungry and too ‘boutique’ for large-scale applications Have been taught by Gary Varner, Stefan Ritt, Eric DeLanges, and Dominique Breton that there’s a more clever and elegant way- straight CMOS – sampling onto an array of capacitors Have formed a collaboration to do this- have all the expert groups involved (formal with Hawaii and France)- see talks by Tang and Jean-Francois at Lyon 9/22/2018 Goals of the Workshop; Argonne

FY-08 Funds –Chicago Anode Design and Simulation (Fukun Tang) 9/22/2018 Goals of the Workshop; Argonne

Front-end Electronics Wave-form sampling does well- CMOS (!) 9/22/2018 Goals of the Workshop; Argonne

Application to a water Cherenkov Counter- effect on the physics 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Application to a water Cherenkov Counter- effect on the physics- can you get much more physics bang for your buck? (and also save big bucks!) What does coverage buy ? What does spatial resolution in x-y buy? Can x-y-z resolution allow track reconstruction? Can x-y-z resolution allow pizero-electron sep? Can one get momentum from multiple scattering? What are the trade-offs in geometry if you have robust (pressure-resistant) detectors? (Mayly) What haven’t we thought of? (e.g. magnetic field for sign determination). 9/22/2018 Goals of the Workshop; Argonne

Strawman Large-area Design “Straw” MCP panel Use AAO to make 1” square active areas in a 64-element array in a single sheet of AAO Use ALD to make coatings Solve (?) ion-feedback problem by “hiding PC” from pore Use small pores and “funnels to get large active area fraction Use septa for current paths 9/22/2018 Goals of the Workshop; Argonne

Strawman Large-area Design “Straw” 2 foot square module 9 8”by 8” double panel stacks make a module Transmission line readout covers full 24” Electronics on the back side so you can tile up to larger modules 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Drafting a Proposal 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Drafting a Proposal 9/22/2018 Goals of the Workshop; Argonne

Specific Questions to Be Answered 3-yr R&D leading to a commercializable large-area device Useful to try to make a resource-loaded schedule, even if it’s R&D with many unknowns Need to identify check-points, risk May need alternative parallel efforts for higher risk efforts Application-specific design can grow out of 3-yr effort 9/22/2018

Specific Questions to Be Answered 3-yr R&D leading to a commercializable large-area device Available for discussion, criticism, etc.- is intended only as a starting point to sharpen discussion- join us! I am not an expert (tho not an excuse for making something like this)- there are many in the room who know at least some of this is nonsense- so be gentle and constructive- take it in the spirit offered, and make it better.. 9/22/2018 ETC- (3 YRS)

Goals of the Workshop; Argonne The End- 9/22/2018 Goals of the Workshop; Argonne

Goals of the Workshop; Argonne Backup Slides 9/22/2018 Goals of the Workshop; Argonne

Anode Return Path Problem Current out of MCP is inherently fast- but return path depends on where in the tube the signal is, and can be long and so rise-time is variable Incoming Particle Trajectory Signal Would like to have return path be short, and located right next to signal current crossing MCP-OUT to Anode Gap 9/22/2018 Goals of the Workshop; Argonne S R

Capacitive Return Path Proposal Return Current from anode Current from MCP-OUT Proposal: Decrease MCP-OUT to Anode gap and capacitively couple the return (?) 9/22/2018 Goals of the Workshop; Argonne

The Future of Psec Timing- From the work of the Nagoya Group, Jerry Va’vra, and ourselves it looks that the psec goal is not impossible. It’s a new field, and we have made first forays, and understand some fundamentals (e.g. need no bounces and short distances), but it’s entirely possible, even likely, that there are still much better ideas out there. Big Questions: What determines the ultimate limits? Are there other techniques? (e.g. all Silicon)? 9/22/2018 Goals of the Workshop; Argonne

Smaller Questions for Which I’d Love to Know the Answers What is the time structure of signals from crystals in PET? (amplitude vs time at psec level ) Could one integrate the electronics into the MCP structure- 3D silicon (Paul Horn, Pierre Jarron)? Will the capacitative return work? How to calibrate the darn thing (a big system)?! How to distribute the clock Can we join forces with others and go faster? Saclay slide 9/22/2018 Goals of the Workshop; Argonne

Present Status of ANL/UC Have a simulation of Cherenkov radiation in MCP into electronics Have placed an order with Burle/Photonis- have the 1st of 4 tubes and have a good working relationship (their good will and expertise is a major part of the effort): 10 micron tube in the works; optimized versions discussed; Harold and Tang have a good grasp of the overall system problems and scope, and have a top-level design plus details Have licences and tools from IHP and IBM working on our work stations. Made VCO in IHP; have design in IBM 8HP process. Have modeled DAQ/System chip in Altera (Jakob Van Santen); ANL will continue in faster format. ANL has built a test stand with working DAQ, very-fast laser, and has made contact with advanced accel folks:(+students) Have established strong working relationship with Chin-Tu Chen’s PET group at UC; Have proposed a program in the application of HEP to med imaging. Have found Greg Sellberg and Hogan at Fermilab to offer expert precision assembly advice and help (wonderful tools and talent!). 9. Are working with Jerry V’avra (SLAC); draft MOU with Saclay 9/22/2018 Goals of the Workshop; Argonne

A real CDF event- r-phi view Key idea- fit t0 (start) from all tracks 9/22/2018 Goals of the Workshop; Argonne

Why has 100 psec been the # for 60 yrs? Typical path lengths for light and electrons are set by physical dimensions of the light collection and amplifying device. These are now on the order of an inch. One inch is 100 psec. That’s what we measure- no surprise! (pictures from T. Credo) Typical Light Source (With Bounces) Typical Detection Device (With Long Path Lengths) 9/22/2018 Goals of the Workshop; Argonne

Geometry for a Collider Detector 2” by 2” MCP’s Typical Area: 28 sq m (CDF) 25 sq m (LHC) =>10K MCP’s Beam Axis Coil Space in the radial direction is expensive- need a thin segmented large-area (30m2) detector 9/22/2018 Goals of the Workshop; Argonne

Small dim. Anode Structure? RF Transmission Lines Summing smaller anode pads into 1” by 1” readout pixels An equal time sum- make transmission lines equal propagation times Work on leading edge- ringing not a problem for this fine segmentation 9/22/2018 Goals of the Workshop; Argonne

Solutions: Generating the signal Use Cherenkov light - fast Incoming rel. particle Custom Anode with Equal-Time Transmission Lines + Capacitative. Return A 2” x 2” MCP- actual thickness ~3/4” e.g. Burle (Photonis) 85022-with mods per our work 9/22/2018 Goals of the Workshop; Argonne Collect charge here-differential Input to 200 GHz TDC chip

Use Cherenkov light - fast Generating the signal for relativistic particles (HEP, nuclear, astro, accelerator- but different for neutrinos) Incoming rel. particle Use Cherenkov light - fast Custom Anode Present work is with commercial MCP’s: e.g. Burle/Photonis Planicons. Expensive (!), hard to get, little flexibility. BUT- it works. And well. 9/22/2018 Goals of the Workshop; Argonne

Starting Point- Time resolution Resolution on time measurements translates into resolution in space, which in turn impact momentum and energy measurements. Silicon Strip Detectors and Pixels have reduced position resolutions to ~5-10 microns or better. Time resolution hasn’t kept pace- not much changed since the 60’s in large-scale TOF system resolutions and technologies (thick scint. or crystals, PM’s, Lecroy TDC’s) Improving time measurements is fundamental , and can affect many fields: particle physics, medical imaging, accelerators, astro and nuclear physics, laser ranging, …. Need to understand what are the limiting underlying physical processes- e.g. source line widths, photon statistics, e/photon path length variations. What is the ultimate limit for different applications? 9/22/2018 Goals of the Workshop; Argonne

Benefit of TOF no TOF 300 ps TOF 1 Mcts 5 Mcts 10 Mcts Better image quality Faster scan time 1 Mcts 5Mcts 1Mcts 1Mcts TOF 5Mcts TOF 5 Mcts 10 Mcts Slide from Chin-Tu Chen (UC) talk at Saclay Workshop Karp, et al, UPenn

Time-of-Flight Tomograph Slide from Chin-Tu Chen (UC) talk at Saclay Workshop  x Can localize source along line of flight - depends on timing resolution of detectors Time of flight information can improve signal-to-noise in images - weighted back-projection along line-of-response (LOR) D One normal variation in PET cameras is the “time-of-flight” or TOF design. By measuring the difference in arrival time at the two detectors, the positron source can be localized along the line of flight. Doing this does not improve the spatial resolution, but improves the signal to noise ratio (the mechanism will be described in more detail in the next slide) — the variance improves by a factor of 2D/ct, where D is the diameter of the radionuclide distribution, c is the speed of light, and t is the TOF resolution. Several TOF PET systems were built in the 1980’s with barium fluoride or cesium fluoride scintillators. They achieved ~500 ps timing resolution, which results in 8 cm localization. For objects the size of the human head (which was what most PET cameras imaged in the 1980’s) the net result is a tomograph with a factor of ~2 lower variance than a non-TOF BGO tomograph. Problems arose from the use of barium fluoride as a scintillator. It is less dense than BGO, and so the spatial resolution is degraded. In addition, the wavelength of its fast emission is in the hard UV, which made it difficult to work with (i.e. expensive) because it does not penetrate glass-windowed photomultiplier tubes or any known glue (to couple the crystal to the photomultiplier tube). Finally, it was difficult to keep these cameras in tune. Thus, TOF PET largely died at the end of the 80’s. However, the advent of LSO and other new PET scintillators (that can provide excellent timing resolution without the material drawbacks of barium fluoride) makes TOF a promising direction for modern PET.  x = uncertainty in position along LOR = c . t/2 9/22/2018 Goals of the Workshop; Argonne Karp, et al, UPenn

Goals of the Workshop; Argonne TOFPET DREAM 30 picosec TOF 4.5 mm LOR Resolution 10 picosec TOF 1.5 mm LOR Resolution 3 pico-sec TOF 0.45 mm LOR Resolution Histogramming No “Reconstruction” 30-50 may be possible (LeDu) Slide from Chin-Tu Chen (UC) talk at Saclay Workshop 9/22/2018 Goals of the Workshop; Argonne