Receptacle Classifications

Slides:



Advertisements
Similar presentations
Electricity Chapter 13.
Advertisements

ZH and ZR Connectors To introduce the ZH crimp style and ZR insulation displacement wire-to-board connector series.
To introduce the PA wire-to-board connector series.
VL Connector To introduce the VL wire-to-board and wire-to-wire, crimp style connector series.
Inspection & Preventive maintenance of breakers
Compliance With Resolution 0859 – Safety of Persons Underwriters Laboratories Inc. March 2008 Refrigerators, Freezers and Combination of Refrigerator-Freezers.
HIL Connector An introduction to the new HIL wire-to-wire, crimp style connector series.
Motorized Tongue Jack Owners Manual Model SAFETY WARNINGS * Read, understand and follow all instructions before installing and/or using product.
Electronics. Solid snap together electronic connectors.
Proposed Design and the Operation of a Disconnecting Device for Small EG Installations Prepared by Hendri Geldenhuys.
SH / SR Connectors PURPOSE: To introduce the SH crimp style and SR insulation displacement wire-to-board connector series.
Hazard - Inadequate Wiring
Bonding, Grounding and the NEC  Presented by The National Association of Certified Home Inspectors
By Carlin Bright. Electricity The flow of electrons in a conductor.
NFPA ELECTRIC VEHICLE SAFETY FOR EMERGENCY RESPONDERS Module II : Basic Electrical Concepts And Hazards Module II : Basic Electrical Concepts And Hazards.
Electrical Safety INSTRUCTOR’S NOTES:
Two Minute Drill #8 Copyright 2005 Ted "Smitty" Smith Practice Code Look Up.
7.1.3 Student Book © 2005 Propane Education & Research CouncilPage Applying a Systems Approach to Gas Appliance Troubleshooting Troubleshooting.
Grounding, bonding, and ground fault currents
Electrical Safety.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Smitty’s Speed Drills 2008 Code Drills Health Care Facilities (C) Copyright 2008 Ted "Smitty" Smith1.
1a.  Exposed part  Live or energized part  De-energized part 1a.
Chapter Electric Current
Chapter 7 Safety. Introduction This chapter covers the following topics: Dangers of electricity Preventive measures Electrostatic discharge Safety practices.
Safety Rules, Practices and Devices Electric Shock – Nerve and muscle (including breathing and heart beat) functions work off of electric pluses (electron.
XMA Connector Purpose: Objectives: Content:
Introduction to switchgears
Ag. Mechanics for Beginning Teachers
Electrical Safety, Subpart K
Electrical Testers Basic test equipment used in today’s shops may include an analog type meter, a VAT (Volt-Amp-Tester), DMM (Digital Multimeter),
HOUSE WIRING Final Review. Electricity Electricity = flow of electrons Conductor= electricity passes thru easily - Metal, water, person Insulator = restricts.
HOUSE WIRING NOTES. Electricity  Proton – positive charge  Electron – Negative charge  Electricity = flow of electrons Conductor= electricity passes.
Screening to Identify Unsafe Electrical Products * * These comments are those of the CPSC staff, have not been reviewed or approved by, and may not necessarily.
2013 HEALTHCARE Training Presentation Harvey Hubbell Electric Company Great History…….Great Connections Harvey Hubbell.
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
TROUBLESHOOTING ELECTRIC MOTORS
Office and Home Electrical Safety
Ground Bond and Ground Continuity Testing
Electrical Safety OSHE 382, Spring 2016
Electricity & Magnetism
High Voltage Engineering
“Success in Safety”.
Electrical Systems.
Circuit Protection Unit 9.
2011 Changes Two Minute Drill
Basic Electrical Safety
Always with appliances V= 230V
Circuit Breakers & Reclosers
ELECTRICAL INSTALLATION AND MAINTENANCE (EIM) 5 INSTALL ELECTRICAL PROTECTIVE DEVICES FOR DISTRIBUTION, POWER, LIGHTING, AUXILIARY, LIGHTNING PROTECTION.
Practical electricity
Personal Protective Equipment
Mechanical Dimensions
Electrical Safety.
Outlet Branch Circuit Arc Fault Circuit Interrupter (OBC AFCI)
ELECTRICAL POWER-II Electrical engineering sixth semester
TROUBLESHOOTING ELECTRIC MOTORS
Grounds Tester GT400 or GT600.
Basic Electrical Safety
DC Motors Starters and Breaking Methods
Wiring Circuits Lesson Plan PSTS: C6-7.
2008 Code Drills Health Care Facilities
Mechanical Dimensions
Biosco: MV/LV prefabricated substations IEC Presentation of the standard Safety is a choice.
Fluid Power System Electrical Control
Presentation transcript:

Receptacle Classifications GENERAL USE – UL498 & CSA C22.2 No. 42 FED SPEC GENERAL GRADE – Federal Specification WC596 HOSPITAL GRADE – UL498 Supplement and CSA C22.2 No. 42 FED SPEC HOSPITAL GRADE – Federal Specification WC596 Third party test laboratories are independent test laboratories who perform testing on a product to maintain the products safety when used in the applications the product was designed for. Basic test and construction requirements for 15 and 20 amp receptacles are contained in UL498 and CSA 22.2, No. 42. Receptacles meeting these standards will have a listing mark indicating the receptacles comply with the standard. Listing marks may be UL, CSA, CUL, CSA-US, indicating compliance with UL or CSA standard.

Receptacle Markings CLASSIFICATIONS MARKINGS GENERAL USE FED SPEC HOSPITAL GRADE FED SPEC/ Third party test laboratories are independent test laboratories who perform testing on a product to maintain the products safety when used in the applications the product was designed for. Basic test and construction requirements for 15 and 20 amp receptacles are contained in UL498 and CSA 22.2, No. 42. Receptacles meeting these standards will have a listing mark indicating the receptacles comply with the standard. Listing marks may be UL, CSA, CUL, CSA-US, indicating compliance with UL or CSA standard. Hospital Grade Hospital Grade Hospital Grade Hospital Grade

Standard Grade/General Use Performance Test Sequence Blade retention Terminal strength Overload Temperature rise Repeat blade retention Resistance to arcing Grounding pin retention Fault Current Dielectric Voltage Withstand Mold Stress Relief Dielectric Voltage Withstand (Repeated) Assembly Security Receptacles may be evaluated to Fed Spec requirements in Federal Specification W-C-596G. These requirements are in addition to the basic requirements in UL498 Receptacles meeting this specification will be identified with the UL Fed Spec Mark. Receptacles may also be evaluated to the Hospital Grade requirements in UL498 and CSA C22.2, No. 42 The Hospital Grade requirements are also in addition to the basic requirements in these standards. Hospital Grade receptacles are identified by a green dot on the face of the receptacle.

Blade Retention After ten insertions of a steel bladed plug gauge The purpose of this test is to ensure that blade retention is maintained. Blade retention is important to avoid a high heat rise situation at the blade and receptacle contact connection. Also to assure the plug can be removed from the receptacle with reasonable force. (UL498, Section 105) Receptacle must retain a polished steel 2 bladed plug gauge against a 3 lb. force for 1 minute Receptacle must release a polished steel 3 bladed plug gauge at 15 lb. force or less

Terminal Strength This test is performed to assure the strength of the termination is maintained. Wire must not be displaced and terminals must not be damaged as a result of this test. (UL498, Section 117) GENERAL USE: Tightened once then tested with 12 AWG wire.

Current Overload Test 100 Insertions & Removals making and breaking DC current at 150% of device rating. The overload test insures there will be no mechanical or electrical breakdown of the receptacle. After the receptacles are conditioned by blade retention test, the overload test is performed.This test is to assure the device will perform properly when it has been subjected to a current overload. A current overload can temporarily occur from inductive load starting such as a motor. (UL498, Section 106)

Temperature Rise The temperature rise test is run at rated load to assure that the terminations and break-off tab stay within an acceptable temperature range when utilized under maximum load conditions. Receptacles subjected to 100 cycles of overload are used for the temperature test. After the temperature test the same receptacle must pass the repeated blade retention test. (UL498, Section 107)

Resistance to Arcing Test The resistance to arcing test insures there will be no mechanical or electrical breakdown of the receptacle. After the 100 cycles of overload test is performed, the receptacles are again conditioned by the blade retention test and tested for 150 additional cycles of plug insertion and withdrawal of DC current at 150% of the rated load. This test is to assure the device will continue to perform acceptably when it has been subjected to the additional current overload. (UL498, Section 109)

Grounding Pin Retention - All Devices This test is performed to ensure that the ground integrity is maintained over a period of use. 5 lb. weight applied for 1 minute in four positions, ground up, down, left and right. Continuity checked during swivel test. (UL498, Section 119)

Fault Current The ground circuit must maintain continuity after the fault current test. The purpose of this test is to assure the ground will maintain its integrity if subjected to a ground fault condition. (UL498, Section 116)

Dielectric 2,000V applied with no arcing or breakdown permitted. The dielectric test is performed to assure isolation between current carrying contacts and ground. The strap of the device is connected to ground. The dieelectric test is conducted using a receptacle that has been exposed to high temperature and high humidity. (UL498, Section 60) 2,000V applied with no arcing or breakdown permitted.

Mold Stress Relief General use: 70°C - 7 hours This test is performed to assure the receptacle will maintain electrical and mechanical integrity when exposed to high temperature. The receptacle cannot distort or show evidence of mechanical or electrical breakdown. After mold stress relief the dielectric strength of the receptacle is measured. (UL498 Section 58)

Assembly Security This test is performed in an attempt to separate the face from the back body and simulate a rugged environment. No mechanical breakage permitted or damage that would prevent receptacle from performing as intended. (UL498, Section 118)

Assembly Security This test is performed to assure the strap will not separate from the face of the device under rugged use. No mechanical breakage permitted. Receptacle must maintain ground continuity. (UL498, Section 118)

ADDITIONAL TEST REQUIREMENTS FOR HOSPITAL GRADE ABRUPT PLUG REMOVAL GROUNDING CONTACT TEMPERATURE GROUNDING CONTACT RESISTANCE GROUNDING CONTACT OVERSTRESS ADDITIONAL TERMINAL STRENGTH ASSEMBLY SECURITY IMPACT INCREASED MOLD STRESS RELIEF Hospital Grade receptacles are specifically designed to provide increased grounding reliability, assembly integrity, strength, and durability.

Hospital Grade Abrupt Removal This test is designed to simulate a plug repeatedly being pulled out by the plug cord. This is a common occurrence with hospital emergency receptacles and even maintenance receptacles. The 10 pound weight is attached to the metal test plug and dropped 24 inches with the ground contact in four positions, ground up, down, left and right. The receptacle cannot show breakage, which will interfere with it's function or integrity, and the ground contact must retain a standard pin weighing 4 oz. for one minute in face down position. (UL498, Section SD21)

Hospital Grade Grounding Contact Temperature Much attention is given to the ground path due to the nature of applications where a hospital grade device is used. The purpose of this test is to assure ground continuity after the device has been abused. Receptacles that have been through the abrupt removal test are wired in series through the ground path and subjected to a 25 amp current for one hour, followed by a 22 amp current until the temperature reaches equilibrium. The temperature of the ground contact must not rise more than 30 degree C (86 degree F). (UL498, Section SD22)

Hospital Grade Grounding Contact Resistance This test is to assure proper continuity between the ground terminal and the ground contact. This is the next test in the sequence of ground contact tests. The test is performed on the same samples used for the abrupt removal and grounding contact temperature test. (UL498, Section SD23)

Hospital Grade Grounding Contact Overstress Conditioning: Oversized .204 in. diameter steel pin inserted 20 times into each ground contact. Test: Each ground contact must retain a .184 in. diameter polished steel pin against a 4 oz. force for 1 minute. Inserting an oversized pin in the ground contact is simulating aging of the receptacle. This test is intended to assure the receptacle maintains ground blade retention. (UL498 Section SD25)

Hospital Grade Terminal Strength HOSPITAL GRADE: Tightened 5 times then tested with 12 AWG wire. In Comparison GENERAL USE: Tightened once then tested with 12 AWG wire. This test is performed to assure the strength of the termination is maintained. Wire must not be displaced and terminals must not be damaged as a result of this test. (UL498, Section SD26)

Hospital Grade Assembly Security HOSPITAL GRADE: 100 lbs In Comparison This test is performed in an attempt to separate the face from the back body and simulate a rugged environment. No mechanical breakage permitted or damage that would prevent receptacle from performing as intended. (UL498, Section SD27) GENERAL USE: 50 lbs

Hospital Grade Assembly Security HOSPITAL GRADE: 100 lbs In Comparison GENERAL USE: 50 lbs This test is performed to assure the strap will not separate from the face of the device under rugged use. No mechanical breakage permitted. Receptacle must maintain ground continuity. (UL498, Section SD27)

Hospital Grade Impact Test This test is performed to simulate the face being struck in high abuse applications often encountered in hospital applications. This test cannot cause breakage that impairs the function of the receptacle. (UL498, Section SD28)

Hospital Grade Mold Stress Relief 90°C – 7 hours In Comparison GENERAL USE: 70°C – 7 hours This test is performed to assure the receptacle will maintain electrical and mechanical integrity when exposed to high temperature. The receptacle cannot distort or show evidence of mechanical or electrical breakdown. (UL498 Section SD29)

ADDITIONAL TEST REQUIREMENTS FOR FED SPEC GRIPPING - POWER BLADE - GROUNDING BLADE TERMINAL STRENGTH OVERLOAD – 200% AC TEMPERATURE RISE REPEAT BLADE RETENTION DIELECTRIC VOLTAGE WITHSTAND INSULATION RESISTANCE HEAT RESISTANCE ASSEMBLY SECURITY The Federal Specification W-C-596 is a document produced by the General Service Administration of the U.S. Federal Government. It is intended to provide for extended service life and durability.

Fed Spec Power Blade Retention Test: Oversized (.075 in. thick) steel blade inserted 20 times in each contact. Conditioning: .075 thk. Steel blade inserted 20 times into current-carrying contact. Test: Each ground contact must retain a .055 thk. Steel blade secured to 1.5 lb weight for 1 minute. After Test: Contacts must retain a steel blade (.055 in. thick) for 1 minute. This test follows the General Use blade retention test. Inserting an oversized blade simulates aging of the receptacle. This test is intended to assure the receptacle maintains blade retention over a period of use. (WC596, Section 4.6.3.1)

FED Spec Ground Blade Retention Conditioning: Oversized .204 in. diameter steel pin inserted 20 times into each ground contact. Test: Each ground contact must retain a .184 in. diameter polished steel pin against a 4 oz. force for 1 minute. Note: This test is the same as Hospital Grade

Fed Spec Terminal Strength Tightened 5 times then tested with min. and max. wire (14-10 AWG). In Comparison GENERAL USE: Tightened once, then tested with 12 AWG wire. This test is performed to assure the strength of the termination is maintained. Wire must not be displaced and terminals must not be damaged as a result of this test. (WC596 Section 4.6.4.2)

Fed Spec Current Overload Test 250 Insertions & Removals making and breaking AC current at 200% of device rating. In Comparison GENERAL USE: 100 Insertions and Removals making and breaking DC current at 150% of device rating. The overload test insures there will be no mechanical or electrical breakdown of the receptacle. After the receptacles are conditioned by the power blade retention test, the overload test is performed.This test is to assure the device will perform properly when it has been subjected to a current overload. A current overload can temporarily occur from inductive load starting such as a motor. (WC596 Section 4.6.5)

Fed Spec Temperature Rise The temperature rise test is run at rated load to assure that the terminations and break-off tab stay within an acceptable temperature range when utilized under maximum load conditions. Receptacles subjected to 250 cycles of current overload are used for the temperature test. After the temperature test the same receptacle must pass the blade retention test. (WC 596 Section 4.6.6)

Fed Spec Heat Resistance 85c for 2 Hours This test is performed to assure the receptacle will maintain electrical and mechanical integrity when exposed to high temperature. The receptacle cannot distort or show evidence of mechanical or electrical breakdown. After heat resistance, the insulation resistance and dielectric strength of the receptacle are measured. (WC596, Section 4.6.10)

Fed Spec Dielectric The dielectric test is performed to assure isolation between current carrying contacts and ground. The strap of the device is connected to ground. The dielectric test is conducted using a receptacle that has been exposed to high temperature. (WC 596 section 4.6.7) 2,000V applied with no arcing or breakdown permitted.

Fed Spec Insulation Resistance The high resistance measurements are required to assure isolation between all metal parts. Insulation resistance is measured after the overload and temperature tests. (WC596, Section 4.6.8)

Fed Spec Assembly Security Fed Spec: 100 lbs. In Comparison General Use: 50 lbs. Same as basic receptacle assembly security test except 100 pound force instead of 50 pound. Same criteria - No mechanical breakage permitted or damage that would prevent receptacle from performing as intended. (WC 596, Section 4.6.14)

Summary GENERAL USE – Meets all requirements for General Use receptacles of UL498 & CSA C22.2 No. 42. FED SPEC – Meets the requirements for General Use receptacles and additional requirements for Federal Specification WC596. HOSPITAL GRADE – Meets the requirements for General Use receptacles and additional requirements for Hospital Grade of UL498 Supplement SD & CSA C22.2 No. 42. HOSPITAL GRADE/FED SPEC - Meets the requirements for General Use receptacles and additional requirements for Federal Specification and Hospital Grade.