USonic-R™ Remote 2-Channel System

Slides:



Advertisements
Similar presentations
Direct Line Supply ArchWeigh HP Belt Scale Internal Speed Sensor The Most Technologically Advanced In-Motion Scale. Click to Advance.
Advertisements

RJ Mann Catalytic Monitoring Systems. RJMCMS 100 Low Cost Single Engine Monitoring System Monitors Pre and Post Catalyst Temperatures, Differential Pressure.
TandD RTR-500 Series Family of Wireless Data Loggers Multiple Data Collection Options Suite of Software Tools.
Open Channel Flow Panel Meters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
Training Course Industrial Solutions. You Can Measure the Benefits… 2 Industrial Solutions  Water and waste  Food and beverage  Chemical  Fuel and.
Paddlewheel Flow Sensors The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current.
Representative Sampling By Chuck Abbott. Automatic Samplers.
High Power Hg Target Conceptual Design Review Hg Target System Controls V.B. Graves P.T. Spampinato T.A. Gabriel Oak Ridge National Laboratory February.
You Can Measure the Benefits… Training Course Introduction to SmartScan.
NorCal Tech 2005 Technical Conference
CHE 185 – PROCESS CONTROL AND DYNAMICS OPTIMIZATION AND PRIMARY LOOP ELEMENTS.
Controller Wiring.
EESIFLO International Pte Ltd
You can Measure the Benefits… Training Course SolidScan’s products.
U-GAGE ® T30UX Series Ultrasonic Sensor with TEACH-Mode Configuration.
High Sensitivity Smoke Detection
Experts in Chem-Feed and Water Treatment An Overview of Possibilities Dulcometer Disinfection Controller ( DDC )
The complete flow monitoring solution Measure – Display – Switch – Transmit.
Solid Applied Technologies Gauger Compact, continuous, non-contact, loop- powered, ultrasonic level meter: Simple installation and configuration.
VisiMix Pipe Line VisiMix Ltd, PO Box 45170, Jerusalem, 91450, Israel Tel: Fax:
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
Well Monitoring Hot Geothermal Wells Pressure, Temperature Tool based on High Temperature Electronics Developed for Commercial Aircraft Engine Control.
© 2010 APM Automation Solutions Ltd. All rights reserved. APM Automation Solutions Ltd. 11 APM Customer Support Technical Training Part 4 Configuration.
You Can Measure the Benefits… Training Course SmartScan Setup & Configuration.
It’s a GasBadge…
Automating Continuous Gas Lift
The Detection Series to Envy.
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
You Can Measure the Benefits… Training Course MonoScan Setup & Configuration.
Ultrasonic Level Transmitters The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and.
CUE – Make Any Pump an E-Pump
Learning Outcomes Upon completion of this training one should be able to: Identify hydronic chilled water system applications. Define the difference between.
Multiple Module Vacuum Oven Productivity Enhancement System.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
RF Admittance Continuous Basics Theory of Operation
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
M20 Shaft Power Monitor PRODUCT TRAINING. Topics 1.What is an M20 Shaft Power Monitor 2.How does it measure Shaft HP 3.Benefits of Shaft Power measurement.
Ultrasound Physics Image Formation ‘97. Real-time Scanning Each pulse generates one line Except for multiple focal zones frame one frame consists of many.
Product Overview Analogue Input, 2fold, SM  Box  Sensor connections
Instrumentation & Measurement
APPLICATIONS Designed and manufactured to meet the needs for constant pressure required by modern plumbing systems, such as : Domestic applications and.
Cold-Chain Expert, Total Solution Quality Precision Service Value
10 12 and 14 TR Advanced Glycol Chiller
Ultrasound Physics Image Formation ‘97.
C1300 advanced circular chart recorder
5708 startup and commissioning
System Network Structure
Kessler-Ellis Products
Ultrasound Physics Image Formation ‘97.
USonic™ Series Continuous Ultrasonic Level Transmitter
Copyright SwissFlow B.V.
LDA Large Display for Analog Inputs
Transmission Media.
FEEDER PROTECTION UNIT
Industrial Instrumentation: Transmitters
Module – Groundwater Level Measurement
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Magnetostrictive Liquid Level Transmitter
Flow-X/C Flow Computer
HBLT-wire Product Introduction September 21, 2018.
F&J SPECIALTY PRODUCTS, INC.
HighPROTEC-2 MRDT4-2 Transformer Protection with differential Sales presentation 2015/08/10.
Chiller Plant Manager (CPM)
Keypad / Display Rev. J -11/21/2018.
Loop Water Controller Overview
Customer Presentation
Red-y compact 2. red-y compact 2 compact 2 series Launch 2015 Adding of alarm module 2016 New concept to replace compact 1 series No more Li-Ion battery.
easYgen-3000XT Series Training
Presentation transcript:

USonic-R™ Remote 2-Channel System

USonic-R™ Continuous Ultrasonics USonic-R Ultrasonic system for Liquid level measurements. 2 channel Line Powered 30 ft. (9.1 m) measurement range Level, Distance, Flow, Volume.

USonic-R™ Features Line Powered Ultrasonic System 24VDC, 110VAC, 220VAC 30 ft. (9.1 m) measurement range 3 inch (76 mm) minimum span 12 inch (305 mm) Near Zone Accuracy: 0.15% or 0.2 inch (5mm), whichever is greater < 0.12 inch (3mm) Repeatability < 0.12 inch (3mm) Resolution

USonic-R™ Features NEMA 4X Remote housing Up to 2 CPVC remote sensors Wall mount Up to 2 CPVC remote sensors Up to 1200 ft. of shielded twisted pair cabling from sensor to electronics Digital Signal between sensor(s) and electronics Provides better RFI / EMI rejection Provides better immunity with Variable Frequency Drives (VFD’s)

USonic-R™ Features Display & Indication Password Protected for configuration Display with graphic tank indication as a bar graph, 1-1/2” X 4” (38mm X 100mm) - 2-line, 7 digit LCD Level, Distance, Flow rate, Totalization, Echo Strength, Temperature, mA, Loss of Echo & Near Zone Engineering Units (Ft., in., %, m, cm, mm)

USonic-R™ Software Software Capabilities Flow GPM or M3/Hr Internal characterizations for over 80 flume/weir types and sizes 2 Totalizers per channel, 1 is user resettable Totalizer Range Selection, X10, X100, X1000, X10,000, X100,000, X1MGD

USonic-R™ Software Differential Level (channel 1 vs. channel 2) Traveling Bar Screen Submerged Flow Sum Level (channel 1 & channel 2) Pump Alternation for 6 pumps Batch Sample Activation Via assignable dry relay contact closure 21-point strapping table for custom tank shape, weir or flume use

USonic™ Outputs Outputs: 6 SPDT relays with 12 programmable trip points 5A / 250VAC rated (2) 4-20 mA Analog outputs (1 per channel) Max resistive load of 1000 ohms Digital connectivity via Modbus Ethernet – as a future product development

USonic-R™ Outputs Data Logging Downloadable to a spreadsheet* 1 to 24 month intervals Intervals of once per minute to once per day Sample interval dependant on max. time period * Specify 401-0700-044 DataView PC software and 15 ft. data cable for data logger download to PC

USonic-R™ Sensors CPVC Sensors 25 Ft. (7.6 m) Flying leads standard, other custom lengths optional to 1200 Ft. (365 m) Sensor leads are simple shielded twisted pair – customer can use own wiring to reduce cost Fully Submersible to IP68 Temp. -40°F to 158°F (-40°C to 70°C)

USonic-R™ Sensors Temperature compensated over full range –40°F to +158°F (-40°C to +70°C) Pressure: -10 psig (slight vacuum) to 50 psig (-0.7 to 3.4 bar) Mounting Options: ¾” / 2” NPT or BSP

USonic-R™ with SmartGain™ A Patented Algorithm embedded in the system that: Automatically ignores obstructions Eliminates Beam angle concerns Allows sensor to be recessed into nozzles to eliminate the dead zone concerns inside of vessel Beam Angle

USonic-R™ – SmartGain™ A 1” pipe (25 mm) can be as close as ½” (12 mm) from the centerline of the beam and ignored. A 2” pipe (50 mm) can be as close as 1” (25 mm) from the centerline of the beam and ignored. SmartGain is also a good choice for horizontal cylinders and spheres – to avoid possible multiple reflections.

SmartGain™ Comparison Drexelbrook method: Tank Mapping method: Bulk mass of liquid reflects the greatest signal strength USonic automatically attenuates receiver gain (based on actual distance to level) to only accept strongest signal reflections Non-level reflections will not produce high enough signal strength to be identified & processed. User must identify that non-level reflections are causing a problem – then enter a routine in the system to eliminate Unit receives all signals from both level and non-level reflections Unit adjusts Threshold level higher than reflections from non-level / base noise signals. Tank must be empty

SmartGain™ Comparison Drexelbrook benefit: Tank Mapping problems: A problem would usually occur before the user would run routine, because… The vessel must be emptied or near empty Agitators, or any moving objects, must be run during programming User must identify actual level then subtract 1.6 ft. (0.5m) User could misadjust, causing level reflection to also be ignored No user routines or programs Vessel doesn’t need to be empty User can’t misadjust or null out level signal reflection Future obstructions will be ignored without user intervention, or reprogramming

USonic-R™ Measurement SmartGain™ A Patented algorithm that automatically ignores most internal vessel obstructions without user adjustments or recordings Full Tank measurement Recess sensor in a nozzle to read level to vessel top Bench Configuration Allows the system to be fully configured in the shop Level and Open Channel Flow Preconfigured flow tables for over 80 primary elements 21-pt. Strapping table for custom shapes and sizes

USonic-R™ Applications in Water and Wastewater Treatment Plants Chemical Slurries Open Channel Flow Lift Stations Traveling Bar Screen Sludge Storage Water Filtration Chemical Mixing Water Wells Sludge Digesters Chemical Storage Primary & Secondary Settling Pump House

Questions?