Red-y compact 2. red-y compact 2 compact 2 series Launch 2015 Adding of alarm module 2016 New concept to replace compact 1 series No more Li-Ion battery.

Similar presentations


Presentation on theme: "Red-y compact 2. red-y compact 2 compact 2 series Launch 2015 Adding of alarm module 2016 New concept to replace compact 1 series No more Li-Ion battery."— Presentation transcript:

1

2 red-y compact 2

3 compact 2 series Launch 2015 Adding of alarm module 2016
New concept to replace compact 1 series No more Li-Ion battery but standard AA battery Touch display very versatile instrument, configurable by user No more plastic path for sensor channel Basically same/similar flow path as red-y smart FW-upgrades can be done by user

4 compact 2 series Versions
Battery Version 24V Power Supply Version Unit with Alarm Contacts - Standard AA Battery - Life time 2-3 weeks continuous use - USB Power supply no backlight USB power supply possible incl. backlight (powerbank, laptop, wall plug adaptor) - Cable with fly leads - Cable with plug type power adapter  Backlit display unless disabled Backlit display unless disabled No plug type power adaptor possible

5 compact 2 alarm module An optional module for the compact 2. Main features are: 3 alarm contacts (relays that can switch up to 1 amp, 30 Vdc) 2 optical isolated input channels (to optionally reset an alarm remotely) Every alarm contact separately settable as high, low, window or totalizer alarm Hysteresis, delay and alarm extension time all customer configurable Built-in 12…30 Vdc power supply, polyfuse protected All variables adjustable locally through the integrated touch screen The alarm module can be easily retrofitted on existing red-y compact 2 meters.

6 Replaces the battery holder:

7 Compact 2 alarm module Alarm module with: 24 volt power input 2 inputs
3 alarm contacts 12 colour coded loose wires going out (fly leads)

8 Functional specs OUT 1 and 2
Switching current output 1, 2 (relay): Rated load: 0.3 A at 125 VAC, 1 A at 24 VDC Max. voltage: 60 VDC,  125 VAC Max. current: 1 A Switching frequency (including de-bounce time):  100 Hz

9 Technical specification OUT3
Switching current output 3 (relay): Rated load: 3 A Max. voltage: 220VDC, 250VAC Max. current: 4 A Switching frequency (including de-bounce time): 100 Hz

10 Technical specification IN1 and IN2
Input 1, 2 (opto-coupler): Voltage range (polarity sensitive): 5 – 30 VDC 5mA max)

11 Technical specification Power supply :
Voltage range : VDC Max. current : 300 mA Protection : Polyfuse (trip current > 500mA) Reverse polarity protected

12

13 Main display compact 2 with alarm
Alarm is active Alarm is inactive Alarm is disabled Alarm is enabled

14 Home Screens with/without Alarm Module

15 Alarm Home Screens New Home Screens provide more information
With alarm module Without Alarm Modul In the menu you can define which home screens are visible

16 Alarm menu diagram Display view with Alarm Module without Alarm Module

17 Alarm Configuration Threshold low Alarm
Threshold in currently set flow unit Hysteresis for automatic reset of the alarms (in %FS) Delay in ms Minimum alarm duration in ms Translation of the alarm stage in the value at output Source for Reset of the alarms Event to trigger the reset of the alarm

18 Alarm Configuration Window Alarm
Type selection (within or out of window) Upper value of window (in currently set flow unit) Lower value of window (in currently set flow unit) Hysteresis at automatic reset of the alarm (in % of Full Scale). The hysteresis is valid for the upper and the lower threshold likewise.

19 Alarm Configuration Totalizer Alarm
Threshold in currently set flow unit At automatic reset of the Totalizer you need to define in the menu „Reset trigger“ if and how a reset will happen.

20

21 Alarm Configuration Flow high alarm with hysteresis and automatic reset

22 Alarm Configuration Flow high alarm with hysteresis and automatic reset

23 Alarm Configuration Flow low alarm with alarm duration, automatic reset and inverted output

24 Alarm Configuration Window alarm with alarm delay and automatic reset

25 Alarm Configuration Window alarm with alarm delay and automatic reset

26 Alarm Configuration Totalizer alarm with alarm duration and edge triggered automatic reset

27 How to update a compact 2 Connect the unit to the computer
Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull Some USB can cause problems, especially the long and badly shielded cables. It is recommended to us the Vögtlin supplied cable.

28 How to update a compact 2 Connect the unit to the computer
Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull Restart the unit. During power-up hold your finger on the display for approximately 3 seconds until the unit switches to Service Mode You do not have to unplug the USB cable to restart, you can do this from the menu as well.

29 How to update a compact 2 Driver is not present Driver is present
Connect the unit to the computer Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull When you connect the unit for the first time to the PC, you need to install a driver on your PC. This will be done automatically when you install the update software Driver is present Driver is not present You only have to install the driver once on your PC

30 How to update a compact 2 Connect the unit to the computer
Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull After a successful installation of the driver, it can take some seconds before the PC recognizes the compact You only have to install the driver once on your PC

31 How to update a compact 2 Connect the unit to the computer
Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull After the latest “rescan” the unit will be recognized and you can press Execute to start the update

32 How to update a compact 2 Connect the unit to the computer
Start the unit up in „Service Mode“ Start the Service Tool on PC Install the driver (first time only) Update the compact 2 Test if the update is succesfull After the update the program will give a confirmation that all connected units are updated After the update press the display for about 5 seconds and the unit will start again with the new firmware.

33 Latest upgrade to FW 3.0.5

34 Connect to the Vögtlin LinkedIn page for updates

35 Intuitive operation via touch display!

36 Flow Control Network – Innovation Award 2016
Great opportunity to promote Vogtlin and compact 2, increase name recognition and create new leads world wide! Compete against Sierra, Emerson, E+H, ITT, Sage, Siemens, etc. Visit innovation-awards-2016/ to see instruction for voting. Action Plan GET VOTES FOR OUR PRODUCT!!! (internal, external, families, all Berwind corporations, customers, reps, …) Promote on Vogtlin and AW-L websites (pop-ups and special designed page) Connect a competition (Vote and Win) Full page Ad in printed Flow Control Magazine PR in various online magazines blast in USA and worldwide Social Media Announcement (LinkedIn, Facebook, Twitter, Google+, … share, share, share!) Temporary signatures

37 Flow Control Network – Innovation Award 2016

38 Flow Control Network – Innovation Award 2016

39


Download ppt "Red-y compact 2. red-y compact 2 compact 2 series Launch 2015 Adding of alarm module 2016 New concept to replace compact 1 series No more Li-Ion battery."

Similar presentations


Ads by Google