LCLS-II CRYOPLANT CONTROLS HARDWARE FINAL DESIGN REVIEW

Slides:



Advertisements
Similar presentations
Subcontractor Electrical Safety & NFPA 70E
Advertisements

Control Circuit Protection Supplementary Protectors vs
DOE Electrical Assessment of C-AD: Inaccurate Electrical Panel Schedules Missing Knockouts Panel Modifications Picture of the Week Collider-Accelerator.
Murray State University
Electrical Safety.
 ELECTRICAL SAFETY Gerald P. Robinson Jr., P.E. – Hatch Mott MacDonald.
Refrigerators.
ARC FLASH ANALYSIS.
Construction Training
1 – Electrical Hazard Recognition EFCOG Electrical Safety Subgroup May 2015 Electrical Safety Month 2015.
“Standard for Electrical Safety in the Workplace”
 Recognize the scope and structure of the OSHA standards.  Identify the common electrical hazards in long term care settings.  Discuss electrical safety.
Occupational Safety and Health Course for Healthcare Professionals.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE PV APPLICATIONS CODES AND STANDARDS EMERGENCY RESPONSE.
P/1 NEMA/NFPA/UL LVDC Conference April 8, 2011 Product Standards Ken Boyce Underwriters Laboratories Inc.
An Introduction to Mersen Electrical Services Putting electrical safety to work.
Chapter One Electrical Design and Component Basics.
INTRUSION ALARM TECHNOLOGY
Flammable and Combustible Liquids
Electrical Safety INSTRUCTOR’S NOTES:
Paul Bellomo LCLS Power March 30, LCLS Injector, Sector 21 and BC1 Power Supply Hazard Analysis Summaries P. Bellomo,
Electrical Safety INSTRUCTOR’S NOTES:
© Evaluating Electrical Risk Factors Module 3.
Electrical Safety INSTRUCTOR’S NOTES:
All Colby employees work with and around electricity on a daily basis. This Safety Talk focuses on the basic electrical safety elements to protect you.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
First Draft Language (B) Service Equipment. In addition to the requirements in (A), service equipment shall contain the following information: (1)
SERVICE ENTRANCE EQUIPMENT
Electrical Safety in the Workplace FN000385/CR. FN000385/CR, Electrical Safety in the Workplace 2 Overview NFPA 70E Objectives Electrical Hazards Mitigation.
Suggestion on How to Use
1 © 2015 Eaton. All Rights Reserved.. Suggestion on How to Use Industry Trainers are encouraged to use this material in their sessions Download the presentation.
Flammable Liquids Directorate of Training and Education
Installation Package - Electrical
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
What is Arc Flash? Electrical arc flash and arc blasts release dangerous levels of heat energy, fire , molten materials, vaporized solids that can be inhaled,
Cryogenic Plant Controls - Configuration
Director’s Progress Review Closeout Meeting
Cryoplant Controls Installation
Kenneth A. Stone Senior Automation Specialist UL508 Standards
Cryogenic Plant Electrical and Controls
Section 6: Air-Conditioning (Heating And Humidification)
LCLS-II 2K Cold Box Controls Design Review
Energy Storage System Guide for Compliance with Safety Codes and Standards Gene Eckhart November 2, 2016.
Hongyu Bai LCLS-II 2 K Cold Box FDR March 9, 2017
LCLS-II Cryoplant Controls Readiness to Procure
"Don't Get Amped Up! Electrical Safety to Keep Your Team Grounded!"
Subpart K Electrical Long recognized as a serious hazard.
General Information for Electrical Installations
Personal Protective Equipment
Electrical Safety Review Compliance Assistance Region IV
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Director’s Progress Review Closeout Meeting
Cryogenic Plant Controls – Safety Switches
Online Emergency Lighting Inverter
Overcurrent Protection— Fuses and Circuit Breakers
Murray State University
EUSERC Training May 2017 Connecting Single phase 3 wire invertor to 3phase 4 wire utility service. Lessons learned - Customer Owned Interconnected Generation.
AGENDA INTRODUCTION CELLS AND COMPONENTS PV PERFORMANCE
Control Hardware & Status
Safety Meeting Topics Standby Generator Safety
Click to start.
Objectives Learn about Electricity Pricing Electric systems.
Objectives Review conductor and conduit selection
Objectives Finish with Practice circuits problems for
Objectives Finish Transformers Introduce HW5 (Pricing)
Presentation transcript:

LCLS-II CRYOPLANT CONTROLS HARDWARE FINAL DESIGN REVIEW Antonio de Lira Sept 13, 2017

LCLS-II CRYOPLANT CONTROLS HARDWARE FDR REVIEW CHARGES 3. ACCESS Is there ample room and adequate lighting inside the cabinets for maintenance? Are the cabinets adequately located (sufficient room around cabinets for safe maintenance)? 4. ES&H and BIO Have all related ES&H aspects been identified, in order to be properly addressed? Will all Cabinets be approved by NRTL? Are appropriate hazard rating signage on panels? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

LCLS-II CRYOPLANT CONTROLS HARDWARE FDR REVIEW CHARGES 3. ACCESS a. Is there ample room and adequate lighting inside the cabinets for maintenance? b. Are the cabinets adequately located (sufficient room around cabinets for safe maintenance)? 4. ES&H and BIO a. Have all related ES&H aspects been identified, in order to be properly addressed? b. Will all Cabinets be approved by NRTL? c. Are appropriate hazard rating signage on panels? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

WORKING INSIDE ENCLOSURES WORKING SPACE AROUND CONTROLS ENCLOSURES 3. ACCESS TOPICS WORKING INSIDE ENCLOSURES WORKING SPACE AROUND CONTROLS ENCLOSURES CONTROLS ENCLOSURE LOCATION 3.a. Is there ample room and adequate lighting inside the cabinets for maintenance? 3.b. Are the cabinets adequately located (sufficient room around cabinets for safe maintenance)? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

3. ACCESS WORKING INSIDE ENCLOSURES PLC enclosures are provided with internal LED strip lighting Ample wiring ducts are provided in control enclosures Finger touch safe connectors No > 50 V exposed connections inside PLC cabinets Enough room for future expansion No need for special tools for field wiring installation: majority of electrical connections are cage-clamp type 120 V ac service outlets will be available close to control enclosures in all areas 3.a. Is there ample room and adequate lighting inside the cabinets for maintenance? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

3. ACCESS WORKING INSIDE ENCLOSURES EQUIPMENT ID LED STRIP LIGHTS TOUCH-SAFE COMPONENTS ROOM FOR FUTURE EXPANSION 3.a. Is there ample room and adequate lighting inside the cabinets for maintenance? CAGE CLAMP, CONNECTORS WIRE DUCTS LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

3. ACCESS WORKING SPACE AROUND CONTROLS ENCLOSURES Placement of control enclosures conform to all conditions of Article 110 of the NEC2014 for dedicated space around, above and below electrical equipment Enclosure locations checked in the cryoplant 3D model Dedicated plan and elevation drawings show coordinates for controls equipment installation Covered in installation FDR NEC 2014 3.b. Are the cabinets adequately located (sufficient room around cabinets for safe maintenance)? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

3. ACCESS WORKING SPACE AROUND CONTROLS ENCLOSURES B905-LCP-1002 Example: placement of Utility PLC enclosure and 120 V ac emergency panel B905-4PB-1004 B905-4DP-1005 B905-2EPB-1001 NEW LOCATION COLUMN 5C B905-4TX-1004 3.b. Are the cabinets adequately located (sufficient room around cabinets for safe maintenance)? FUTURE UTILITY PLC ENCLOSURE LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

3. ACCESS CONTROLS ENCLOSURE LOCATION Plan view drawings show coordinates for controls equipment installation All controls enclosures captured in cryoplant 3D model DWG # Sheet # DWG Description 79120-1714 E4.1.1 Compressor room 1 enclosure location 79120-1715 E4.1.2 Compressor room 2 enclosure location 79221-1706 E4.1.3 Cold Box room enclosure location 79720-1703 E4.1.4 Tank Farm enclosure location 3.b. Are the cabinets adequately located (sufficient room around cabinets for safe maintenance)? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

3. ACCESS CONTROLS ENCLOSURE LOCATION Excerpt from cold box room enclosure location 3.b. Are the cabinets adequately located (sufficient room around cabinets for safe maintenance)? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

Yes, inside the PLC cabinets 3. ACCESS SUMMARY Is there ample room and adequate lighting inside the cabinets for maintenance? Yes, inside the PLC cabinets 120 V ac outlets installed close to all control enclosure b. Are the cabinets adequately located (sufficient room around cabinets for safe maintenance)? Yes. Controls cabinets located per Article 110 of the NEC2014 Control enclosure location checked in 3D model LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

LCLSII CRYOPLANT CONTROLS HARDWARE FDR REVIEW CHARGES 3. ACCESS a. Is there ample room and adequate lighting inside the cabinets for maintenance? b. Are the cabinets adequately located (sufficient room around cabinets for safe maintenance)? 4. ES&H and BIO a. Have all related ES&H aspects been identified, in order to be properly addressed? b. Will all Cabinets be approved by NRTL? c. Are appropriate hazard rating signage on panels? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

4. ES&H and BIO ES&H ASPECTS - Enclosures covered under this procurement Aspect & Risks Standard Mitigation Electrical Shock Arc flash Overcurrent Fire NEC2014 NFPA 70E BIO Proj 17-085 SLAC Control of Hazardous Energy (CoHE) Program No exposed > 50 V inside PLC enclosures All terminals are finger touch safe in PLC cabinets No stored energy inside cabinets (no batteries, or > 10 J capacitors) Voltage LED indicator on door of control heater enclosures (> 120 V ac) Disconnect switches are lockable and do not allow opening the enclosure door while it is energized All enclosures have a lockable upstream breaker Placement of SLAC danger labels per short circuit and arc flash calculations Fuses, circuit breakers per Article 240 of the NEC2014 Internal/Field wiring sized per ANSI/UL 508A UL recognized components Enclosure installation per NEC2014 requirements Environmental rain, humidity dust SLAC EEIP NEMA 3R enclosures IP54 filter fans for enclosures located indoors Enclosure heater Structural/Seismic - Equipment integrity SLAC ES&H Seismic Design Specification BIO Proj 17-085, Comment #90 Free-standing, floor-mounted PLC enclosures, seismic rated for zone 4 Seismic calculations and equipment anchoring requirements predefined Thermal - Hot surfaces Cooling fans to keep enclosure temperature < 50 °C 4.a. Have all related ES&H aspects been identified, in order to be properly addressed? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

4. ES&H and BIO CERTIFICATION - Enclosures covered under this procurement JLab Specification 79120-S1500 Built to print Material list provided in JLab drawings All UL recognized components Enclosures to be manufactured by a UL listed panel shop Enclosures to comply with construction requirements from ANSI/UL 508A (Standard for Safety for Industrial Control Panels) 4.b. Will all Cabinets be approved by NRTL? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

4. ES&H and BIO HAZARD LABELS SAMPLE SLAC will conduct a short circuit/arc flash study for the entire cryoplant construction SLAC will issued danger labels for controls enclosures 120 V and above per NFPA 70E (Standard for Electrical Safety in the Workplace) Shock/Flash protection Flash hazard category Protection boundaries PPE requirements Equipment ID Equipment sources Load 4.c. Are appropriate hazard rating signage on panels? SAMPLE LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

b. Will all Cabinets be approved by NRTL? 4. ES&H and BIO SUMMARY Have all related ES&H aspects been identified, in order to be properly addressed? Yes, ES&H aspects of the control enclosures have been addressed during design and specification b. Will all Cabinets be approved by NRTL? No. Controls enclosures will be manufactured by a UL listed panel shop and EEIP’d at SLAC c. Are appropriate hazard rating signage on panels? Yes. SLAC will provide the danger labels for all enclosures powered by > 120 V ac LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017

Questions? The End 4.b. Will all Cabinets be approved by NRTL? LCLS-II Cryoplant Controls Hardware FDR, Sept 13, 2017