What we have learned about NZEB in 2017 (With thanks to our students)
1 CPC & EPC will both need to be below 0.2 for NZEB
2 Projected PE factors are needed to safeguard investment
3 Default Y-factors are potential signals of incompetence
4 Upskilling in NZEB will require new delivery methods
What is NZEB?
NZEB Definition Definition of NZEB for new build residential adopted by DIT: 30kWh/m2a (maximum) measured in DEAP Including up to 35kWh/m2a on-site renewables Almost an A1 BER
NZEB Definition
NZEB Definition
NZEB Definition
NZEB Definition Typical BER A3 Typical BER ≈ A1
1 CPC & EPC will both need to be below 0.2 for NZEB
Scope of the study 13 Unique New Dwellings studied: Detached single storey Detached two storey Semi-detached two storey Terraced two storey Top floor Apartment Approx. 70% “live” projects Rural and urban sites
EPC target values for NZEB Average Energy Performance Coefficient (EPC) Part L = 0.350 NZEB = 0.164 NZEB Range: 0.128 – 0.185 MPEPC
CPC target values for NZEB Average Carbon Performance Coefficient (CPC) Part L = 0.315 NZEB = 0.157 NZEB Range: 0.134 – 0.189 MPCPC
Renewables contribution Average Onsite Generated Renewables (kWh/m2a) Part L = 18 kWh/m2a NZEB = 25 kWh/m2a (Limit: 35 kWh/m2a) NZEB Range: 18 – 29 kWh/m2a
2 Projected PE factors are needed to safeguard investment
Primary Energy Factor Primary Energy factor of mains electricity in Ireland 2000 to 2025 2016: 2.19 2020: 1.5? 2030: 1.1?
Primary Energy Factor
Primary Energy Factor Direct electrical space heating Instant electrical water heating PV renewables Gas boiler Part L NZEB 2.19
Primary Energy Factor Part L NZEB 2.19 1.80
Primary Energy Factor Part L NZEB 2.19 1.80 1.40
Primary Energy Factor Part L NZEB 2.19 1.80 1.40 1.00
Primary Energy Factor Part L NZEB 2.19 1.80 1.40 1.00
Primary Energy Factor Primary Energy Factors will fluctuate wildly as the grid decarbonises Buildings which complied when designed may not comply on completion as a result We need a building lifetime average PE factor to design to Is it unreasonable to suggest it be set at 1.1 for buildings due for demolition after 2075?
3 Default Y-factors are potential signals of incompetence
Y-Factor Calculated to default spread 0.01 to 0.15 50% of heat losses
Y-Factor Detail selection Psi-value spread 0.005 to 0.181
4 Upskilling in NZEB will require new delivery methods
5 Upskilling in NZEB will require new delivery methods http://www.mens-nzeb.eu/en/education/distant-learning/webinars/636317779981826208//
A word of advice to suppliers …
Glazing Type Part L 25% triple glazed NZEB 89% triple glazed
Main Fuel Type Part L 9% electrical NZEB 75% electrical
And now its over to our upskilled graduates …