FIRE ALARM TRANSMISSION METHODS “NFPA ”

Slides:



Advertisements
Similar presentations
Denver Fire Alarm Test FUNDAMENTAL, POWER SUPPLIES, CIRCUITS, INSPECTIONS, TESTING and MAINTENANCE.
Advertisements

Chapter Eight: The Telephone System
Chapter 5 Voice Communication Concepts and Technology.
Transmitting Fire Alarms Reliably After the Sunset of the PSTN Gregory Lapin, PhD, PE King-Fisher Company, inc Lowell, MA.
Welcome to the Radionet Monitoring Secure-Com Presentation.
ARC reporting ARC Cerny Verze
1 Telephone Connection. 2 Introduction The section instructs you on how to install a required phone line to every receiver.
Initiating Devices Manual Fire Alarm Boxes Ionization Smoke Detectors
GS3055-I Installation Process
Ch. 10 Circuit Switching and Packet Switching
BASIC TELECOMMUNICATIONS
NFPA National Fire Alarm & Signaling Code
VoIP alarm monitoring. Traditional alarm systems Motion sensor Smoke detector Camera Premise Controll Unit Fire station Security service Central station.
GS3055-I GSM Universal Wireless Alarm Communicator
Ted “Smitty” Smith  I have included in the following slides some key sections from each of the codes you will primarily encounter on the test. I recommend.
Principles of Information Systems, Sixth Edition Telecommunications and Networks Chapter 6.
UL Code th Edition An Overview of the Foremost Code Updates.
2003 IFC SCFPA Symposium July 28, 2010 Fire Alarm Communication Technologies LeRoy McNulty Lynnwood Fire Department.
G- Welcome to our DSC IMPASSA & IP Communicators Road Show!
1 Fox Valley Fire & Safety’s Wireless Radio Network Our customers experience reduced monitoring costs; normally 25% or more. Eliminates expensive phone.
21 st Century Voice Networks and the National Fire Alarm and Signaling Code June 8, 2010 NFPA Expo Session Roy Perry
Status of Public Safety Sector Discussions and Next Steps October 15, 2014.
Computers Are Your Future © 2006 Prentice-Hall, Inc.
FIRE ALARM SYSTEMS AND FUNDAMENTALS
Ted “Smitty” Smith  This slide show contains multiple timed questions. All questions can be answered using the International Fire Code, The National.
Chapter 14: Inspection and Maintenance
EC4019PA Intrusion & Access Control Technology (IACT) Chapter 4- CAMS Prepared by Sandy Tay.
Signaling and Switching Chapter 6. Objectives In this chapter, you will learn to: Define modulation and explain its four basic versions Explain the different.
Commissioning of Fire Protection and Life Safety Systems Presented by: Charles Kilfoil Bechtel National Waste Treatment Plant Richland WA.
Cintas Fire Protection
Presentation on the Cable- Related Needs Assessment for Washington County CBG Communications, Inc. 73 Chestnut Road, Suite 301 Paoli, Pa P: (610)
GS3055-I GSM Universal Wireless Alarm Communicator
How to Sell T-Link TL250/300. T-Link Internet & Network Alarm Communicators Internet alarm communications for multi-branch Financial Institutions, Governments,
Paradox Communication Solution GPRS / GSM
Introduction to Information Systems Lecture 06 Telecommunications and Networks Business Value of Networks Jaeki Song.
GS3055-I Installation Process
AICC Members CSAA CSAA ESA ESA SIA SIA ADT ADT AFA Protective Systems AFA Protective Systems Alarm Detection Systems Alarm Detection Systems Bay Alarm.
Innovative Applications: Satellite Deployment for Emergency Backup Presented by Mark Ayers, GCI.
Principles of Information Systems, Sixth Edition Telecommunications and Networks Chapter 6.
1 ARC reporting ARCCerny Verze INTERNET ARC events reporting Control panel 3. PSTN Telephone network - CID 1. GSM network – GPRS IP CID.
Telecommunications and Networks Chapter 6 Principles and Learning Objectives Effective communication is essential to organizational success. –Define.
Data Communication and Networks Chapter 5. What’s a Network? a network consists of two or more computers that are connected together to share information.
Fire Alarm Verification CAN/ULC-S561-03
Class A, B, and now N NFPA 72, 2016 Edition Dan Horon President
INTEGRATED SERVICES DIGITAL NETWORK
Principles of Information Systems, Sixth Edition 1 Telecommunications and Networks Chapter 6.
OSI Model OSI MODEL. Communication Architecture Strategy for connecting host computers and other communicating equipment. Defines necessary elements for.
OSI Model OSI MODEL.
NFPA National Fire Alarm & Signaling Code
Carbon Monoxide Detection: Code and Legislation Updates
VoIP ALLPPT.com _ Free PowerPoint Templates, Diagrams and Charts.
By Asma Hamad Alharbi.
MISY 3312: Introduction to Telecommunications Summer 2012 VoIP
NFPA Circuits & Pathways
Communications Infrastructure
Standards Changes that will Affect Signal Receiving Centres in Canada
DEPARTMENT OF COMPUTER SCIENCE
Fire Alarm Systems for Emergency Operations of Elevators
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
DATA COMMUNICATION Lecture-32.
William Stallings Data and Computer Communications
The duress & emergency Lift telephone (DET) service
NICET Fire Alarm Tech Level 1 Practice Test # 13
General Requirements of NFPA 101
Chapter 12: Circuit Switching and Packet Switching
Computers Are Your Future
Chapter 4: Data Communication and Networks
OSI Model OSI MODEL.
Area of Refuge It’s the Law!
FIRE ALARM DRILL 26 © Ted Smith 2017.
Presentation transcript:

FIRE ALARM TRANSMISSION METHODS “NFPA 72 2013” Louis T. Fiore FIRE ALARM TRANSMISSION METHODS “NFPA 72 2013” March 14, 2012

Methods in NFPA 72 Chapter 26 DACT One-Way Private Radio Two-Way Radio Performance Based Technologies

“Digital Alarm Communicator Transmitter” First defined in NFPA 71 DACT “Digital Alarm Communicator Transmitter” First defined in NFPA 71

NFPA 72 The next edition (2013) will see DACT and a second technology (not two phone lines). The current (and perhaps final) version of NFPA 72-2013 requires a 6 hr DACT test rather than 24 hrs. The 2016 Edition will probably “sunset” DACT altogether. Two-Way radio, Private One-Way Radio, Digital Cellular and IP will survive as your only communications alternatives. NITNAM Procedure

26.6.3.1 Performance Based Technologies Single Path 60 second polling or check-in Multiple Paths 6 hour polling or check-in on each side Digital Cellular IP/Internet

Current Version (2010): 26.6.3.2.1.4 Transmission Channels. (A) A system employing a DACT shall employ one telephone line (number). In addition, one of the following transmission means shall be employed: (1) A second telephone line (number) (2) A cellular telephone connection (3) A one-way radio system (4) A one-way private radio alarm system (5) A private microwave radio system (6) A two-way RF multiplex system (7) A transmission means complying with new technologies section

VoIP

Issues for Alarms with VoIP Pass alarm DACT signal formats in an undistorted fashion Ensure Line Seizure is not compromised The ability to provide for our control panels to "see” a telephone line equivalent (voltage and dialtone) VoIP and cable/ISP hardware should have sufficient backup power

MFVN in NFPA 72-2010 Definition: 3.3.141 Manage and maintain their network to ensure service quality and reliability Provide a service that is functionally equivalent to traditional analog phone service (dialing, dial plan, and loop voltage treatment), Provide real-time transmission of voice signals that carry alarm system formats unchanged, Provide both professional installation and subscriber information …….which preserves primary line seizure for alarm system interconnection, and Have disaster recovery plans to address both individual customer outages and widespread events of a catastrophic nature, including network power restoration equivalent to traditional landline telephone services.

One Way Private Radio Two-Way RF Multiplex AES-Intellinet AlarmNet A AlarmNet M AAGARD HolmesNet

Transmission Channels (A) A system employing a DACT shall employ one telephone line (number). In addition, one of the following transmission means shall be employed: (1) A one-way private radio alarm system (2) A two-way RF multiplex system (3) A transmission means complying with 26.6.3.1 (performance-based technologies) Exception: Where access to two technologies listed above is not available at the protected premises, with the approval of the authority having jurisdiction, a telephone line (number) shall be permitted to be used as the second transmission means.

26.6.3 Communications Methods. The communications methods used to transmit signals to supervising stations shall meet the requirements of 26.6.3.1 for performance-based technologies, or 26.6.3.2 (Digital Alarm Communicator Systems) or 26.6.3.3 (Radio Systems) for prescriptive-based technologies. 26.6.3.1 Performance-Based Technologies. 26.6.3.1.1 Conformance. Communications methods operating on principles different from specific methods covered by this chapter shall be permitted to be installed if they conform to the performance requirements of this section and to all other applicable requirements of this Code.

26.6.3.1.5 Single Communications Path. Unless prohibited by the enforcing authority, governing laws, codes, or standards, a single transmission path shall be permitted, and the path shall be supervised at an interval of not more than 60 minutes. A failure of the path shall be annunciated at the supervising station within not more than 60 minutes. The failure to complete a signal transmission shall be annunciated at the protected premises in accordance with 10.12. 26.6.3.1.6 Multiple Communications Paths. If multiple transmission paths are used, the following requirements shall be met: (1) Each path shall be supervised within not more than 6 hours. (2) The failure of any path of a multi-path system shall be annunciated at the supervising station within not more than 6 hours. (3) The failure to complete a signal transmission shall be annunciated at the protected premises in accordance with 10.12. 26.6.3.1.7 Single Technology. A single technology shall be permitted to be used to create the multiple paths provided the requirements of 26.6.3.1.6(1) through 26.6.3.1.6(3).

26. 6. 3. 1. 5 Single Communications Path 26.6.3.1.5 Single Communications Path. Unless prohibited by the enforcing authority, governing laws, codes, or standards, a single transmission path shall be permitted, and the path shall be supervised at an interval of not more than 60 minutes. A failure of the path shall be annunciated at the supervising station within not more than 60 minutes. The failure to complete a signal transmission shall be annunciated at the protected premises in accordance with 10.12.

26. 6. 3. 1. 6 Multiple Communications Paths 26.6.3.1.6 Multiple Communications Paths. If multiple transmission paths are used, the following requirements shall be met: (1) Each path shall be supervised within not more than 6 hours. (2) The failure of any path of a multi-path system shall be annunciated at the supervising station within not more than 6 hours. (3) The failure to complete a signal transmission shall be annunciated at the protected premises in accordance with 10.12.

26.6.3.1.7 Single Technology. A single technology shall be permitted to be used to create the multiple paths provided the requirements of 26.6.3.1.6(1) through 26.6.3.1.6(3).

Questions?