Unit 2: Chapter 2 Cooling.

Slides:



Advertisements
Similar presentations
SAN DIEGO SUPERCOMPUTER CENTER at the UNIVERSITY OF CALIFORNIA, SAN DIEGO Green Datacenter Initiatives at SDSC Matt Campbell SDSC Data Center Services.
Advertisements

Chapter 3. HVAC Delivery Systems
Clair Christofersen Mentor – Aaron Andersen August 2, 2012
Heating, Ventilating, and Air-Conditioning
Environmental Controls I/IG Lecture 14 Mechanical System Space Requirements Mechanical System Exchange Loops HVAC Systems Lecture 14 Mechanical System.
Key HVAC Design Concepts. Agenda Discuss relevance of thermal enclosure system to HVAC system. Present the three major steps to design an HVAC system.
Components of HVAC System
HVAC: heating, ventilating, and air conditioning this is a thermostat: it sends signals to the heating/cooling system.
Cooling Product Positioning
Cloud Computing Data Centers Dr. Sanjay P. Ahuja, Ph.D FIS Distinguished Professor of Computer Science School of Computing, UNF.
Thermal Management Solutions from APW President Systems
 Site  Requirements  Local Resources  Initial layout ideas  Brief material selection  Supply options.
Computer Room Experiences A medium sized tier-2 site view Pete Gronbech GridPP Project Manager HEPIX April 2012.
Refrigeration and Heat Pump Systems Refrigeration systems: To cool a refrigerated space or to maintain the temperature of a space below that of the surroundings.
September 18, 2009 Critical Facilities Round Table 1 Introducing the Heat Wheel to the Data Center Robert (Dr. Bob) Sullivan, Ph.D. Data Center Infrastructure.
Contributed by: Integrated Teaching and Learning Program, College of Engineering, University of Colorado at Boulder.
HVAC523 Heat Gain. Heat First law of thermal dynamics states that HEAT TRAVELS FROM HOT TO COLD. 95 degree outside air will flow through the building.
Best Practices in HVAC Design/Retrofit
Afternoon Agenda Deciding on your soldering equipment and important factors to consider on configuration for a robust process Reflow.
Applying Precision Air Conditioning Systems
Important variables Water: Air: Conversion:
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
Data centre air management Case studies Sophia Flucker.
 Design a data centre for a large computing company  To have high efficiency standards  Utilise renewable technology  To be an exemplar in design.
NOVO ETS IMPROVING YOUR ORGANIZATIONS’ ENVIRONMENTAL, HEALTH AND SAFETY PERFORMANCE ENERGY MANAGEMENT IN THE CONTEXT OF GREEN PRODUCTIVITY.
Energy Conservation Physics /24/03. Reducing energy consumption may help alleviate environmental problems: Conserve fossil fuel resources Reduce.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
Thermal Design Project Final Report John Wallerich Principal Engineer Wallerich Group, LLC.
Dealing with Hotspots in Datacenters Caused by High-Density Computing Peter Hannaford Director of Business Development EMEA.
The Data Center Challenge
HEATING AND COOLING SYSTEMS
We can…. 2 GLOBAL REFERENCES Rev: 00 References :
COMP 4923 A2 Data Center Cooling Danny Silver JSOCS, Acadia University.
EXPLORING ENERGY MANAGEMENT. PROJECT TITLE What is Energy Management? Energy management is doing more with the same amount of energy or less energy. Energy.
Authors: William Tschudi, Lawrence Berkeley National Lab Stephen Fok, Pacific Gas and Electric Company Stephen Fok, Pacific Gas and Electric Company Presented.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Green Server Room Construction Primary concerns when building a server room is size and cooling. Size can be diminished with the use of virtual servers.
Energy Basics Understand it, Control it and Save.
All content in this presentation is protected – © 2008 American Power Conversion Corporation Row Cooling.
1 PCE 2.1: The Co-Relationship of Containment and CFDs Gordon Johnson Senior CFD Manager at Subzero Engineering CDCDP (Certified Data Center Design Professional)
Ventilation & Airflow NetShelter CX 18U,24U,38U Ambient office air is drawn in to the soundproofed air-intake chambers on either side of the NetShelter.
VENTILATION AND AIR CONDITIONING Under the Subject Industrial Safety and Environment || ||
Location: Rockler Headquarters, Medina, MNRTUs: 1 Founded in 1954, Rockler Woodworking & Hardware is a specialty store dedicated to bringing woodworking.
Heat transfer Steady state conditions not for dynamic systems in buildings through walls, roofs, floors, windows, doors building structures and U-values.
Free Air Cooling for Data Centres
Air source heat pump Understand the fundamental principles and
Electrical Power and Cost of Electricity
Part 16 Technician’s Guide & Workbook for Duct Diagnostics and Repair
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Maria’s Restaurant Chapter 1 Section 4
DESIGN AND DEVELOPEMENT OF AIR CONDITIONING CUM WATER COOLER
The Data Center Challenge
Welcome to the Colorado Restaurant Association Pikes Peak Chapter Energy Efficiency in the Restaurant Industry.
HVAC EQUIPMENT: COOLING SOURCES (see Chapter 16)
CERN Data Centre ‘Building 513 on the Meyrin Site’
RESIDENTIAL HVAC (HEAT LOSS & GAIN)
Conduction Cooling Loads
Lecture Objectives: Discuss HW3 parts d) & e) Learn about HVAC systems
Energy Efficiency in District Coiling System
Did you know? In the U.S. alone, buildings account for: 72% of electricity consumption
Cloud Computing Data Centers
Exploring Energy Management
FBE03: Building Construction & Science
UNDERSTANDING YOUR BUILDING AND CLIMATE CONTROL
Cloud Computing Data Centers
Reducing Electrical Energy Consumption
Exploring Energy Management
Exploring Energy Management
Objective Revie the Cooling Cycle Learn about air distribution systems
Liebert DSE High efficiency thermal management
Presentation transcript:

Unit 2: Chapter 2 Cooling

Cooling Costs Some estimates state that cooling can account for upward of 63 percent of your IT department’s power usage. Electricity is paid for per kilowatt-hour (kWh). This is a measure of the hourly consumption of electrical power. Let’s use a basic electrical device—the household incandescent light bulb—to determine how much electricity costs. A 100-watt (W) bulb uses 100 watt-hours of electricity in 60 minutes. As such, ten 100 W light bulbs will use a total of 1 kWh of electricity per hour.

Causes of Cost Increased power consumption as more servers and storage devices are deployed. • Increased heat density in the racks because of increased computing power in a confined space. Irregular heat load in the datacenter. Increasing power costs A tendency to overcool datacenters.

Room Size All the equipment in your server room generates heat. So does the lighting. And so do the people working there. All these sources of heat contribute to the heat load of the server room. Typically this number is expressed in British Thermal Units (BTUs) or kW. One kilowatt is the same as 3412 BTUs. In order for your air conditioner to cool a room, its output must be greater than the heat load

The room itself requires cooling The room itself requires cooling. To calculate the cooling needs of the room, use this formula: Room Area BTU = Length (meters(m)) × Width (m) × 337

Reducing Cooling Costs Economizers: You can save a lot of money if you are able to put Mother Nature to work for you. In a lot of the country, winter provides you with an opportunity to enhance your cooling system by using the cold outside air to cool things down. But it isn’t as simple as opening a window to accomplish this. To do so, you need to employ what is called an economizer. There are two types: air-side economizers and waterside economizers.

Air An air-side economizer regulates the use of outside air for cooling a room or a building. It employs sensors, ducts, and dampers to regulate the amount of cool air brought in.

The sensors measure air temperature both inside and outside the building. If it notices that the outside air is suitably cold enough to cool the datacenter, it will adjust its dampers to draw in the outside air, making it the main source of cooling.

Fluid A water-side economizer utilizes evaporative cooling (usually provided by cooling towers) to indirectly produce chilled water to cool a datacenter when outdoor conditions are cool (often at night). Water-side economizers are especially beneficial, because not only do they save costs, but they don’t allow contaminants or altered humidity levels into the datacenter.

Optimizing Airflow Air exchange is important. To deliver the precise cooling environment, air must be exchanged at a sufficient rate. Normal office environments must change air over twice an hour. In high-density datacenters, air has to be exchanged 50 times an hour. If enough air is not exchanged, cooling air will heat up before it reaches the equipment, and disaster could occur.

Hot Aisle/Cold Aisle

Raised Floors Datacenters are conventionally built on a floor that is raised 18 to 36 inches. The higher the floor level, the more air that can be distributed under the floor and the more air that can be used by the cooling system. Cable Management Vapor Seal: If you have a poor vapor barrier, humidity will move into the datacenter during hot months and escape during the winter months.

Prevent Recirculation of Equipment Exhaust 1. Hot-aisle/cool aisle Employ the hot-aisle/cool-aisle design mentioned earlier in this chapter. 2. Rigid enclosures Build rigid enclosures to keep exhaust heat from being sucked back into the device’s cool air intakes. 3. Flexible strip curtains Use flexible strip curtains to block the open air above your racks that have been configured into a hot-aisle/cool-aisle layout.

4. Block unused rack locations with blanks Equipment typically draws in cool air from the front and exhausts it out the back. Blanking open areas under equipment prevents the exhaust from being drawn back into the device. 5. Design with cooling in mind Although most do, some equipment does not draw air in from the front and exhaust it out the back. Some have top-discharge or side to- side designs. Configure your racks to ensure your equipment doesn’t blow into the intake of other equipment. 6. Select racks with good airflow Buy racks that don’t have an internal structure that would block the smooth flow of air to your equipment.

Supply Air Directly to Heat Sources. Fans Humidity Adding Cooling: Fluid Considerations System Design: Closed systems are good for small solutions, assuming there is adequate ventilation if the system fails. Datacenter Design Centralized Control: This sort of system offers several benefits over the prevalent multiple-distributed unit system. Better efficiency., Less maintenance is required.