MAKING HEALTH CARE SAFE ENGINEERING AND SAFE ANAESTHESIA

Slides:



Advertisements
Similar presentations
Unit C: Agricultural Power Systems
Advertisements

Carburetion Systems Small Engines.
Using Gas Welding Equipment
ANESTHETIC MACHINES.
Safety Requirements of the Anesthesia Workstation
Anesthesia Machine Presented by Gil Soto C.R.N.A.
INTERMEDIATE PRESSURE SYSTEM PRESENTED BY: Dr CHITTRA MODERATED BY: Dr JYOTI PATHANIA.
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 1 of 4.
Utility Management Providence Health System - Oregon Environment of Care.
Anesthesia Apparatus Checkout Recommendations
Supply Of Medical Gases
Medical Gas Supply By Ahmed Ibrahim ; M.D. Prof.of Anaesthesia Ain Shams University.
Inhaled Anesthetic Delivery Systems
Labyrinth seal into two halves
Gas Welding (Oxy-acetylene)
Check Valves and Manufacturer-Recommended Leak Test
Engine Systems and Components
Anesthetic Equipment.
Hydraulics.
 The annular space. The clearance between the head of the float and the flow tube is known as the annular space.
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
By Dr. Ahmed Mostafa Assist. Prof. of anesthesia and I.C.U.
Sensors used in EFI (Electronic Fuel Injection)
Flow Meters Flow: Volume of a fluid passing certain point over a given time Flow Rate. over a given time Flow Rate. Flow meters:sets used to measure flow.
Parts of the Anesthetic Machine
The Anesthesia Gas Machine
CARBURETED FUEL SYSTEM
A). When the carrier gas is quickly switched to 100% nitrous oxide (B). the halothane concentration decreases to 3% within 8 to 10 seconds A new steady-state.
Dr. S. Parthasarathy MD., DA., DNB, MD (Acu), Dip. Diab. DCA, Dip. Software statistics PhD(physiology) Mahatma gandhi medical college and research institute,
Products Training.
Teknologi Dan Rekayasa
High Pressure Lifting Bags
To Menu.
CENTRAL GAS SYSTEMS Without reference, identify principles relating to central gas systems as they pertain to facility and equipment interface with at.
Introductory Lecture Series: The Anesthesia Machine
 A piston is a component of reciprocating engines, reciprocating pumps, gas compressors and pneumatic cylinders, among other similar mechanisms. It is.
Without reference, identify principles about Anesthesia Units with at least 70 percent accuracy.
To Menu.
Parts of the Anesthetic Machine A&A Pages
Introductory Lecture Series: The Anesthesia Machine
MECH1300 Pneumatic Components Topics Pneumatic Cylinders Pneumatic Motors Other Pneumatic Actuators Pneumatic Directional Control Valves Pneumatic Flow.
IDENTIFY THE MAJOR SYSTEMS OF AN ENGINE!. NEXT GENERATION SCIENCE/COMMON CORE STANDARDS ADDRESSED! CCSS.ELA Literacy.RST.9‐ 10.3 Follow precisely a complex.
PART 3: Breathing System Parts
Automotive Heating And Air Conditioning
Valve Train Assemblies
Chapter 37: Fluid Containment
Unit III Class II Pneumatic actuators.
HYDRAULIC AND PNUEMATIC ACTUATION SYSTEMS
Anaesthesia for healthy patient
Using Gas Welding Equipment
Piped gas supply Description
Gas Cylinders Description
Oxyacetylene Welding Processes
Parts of the Anesthetic Machine Parts 1 & 2: A&A pages
Pneumatic schematic of the Dräger Infinity V500 intensive care ventilator. A. Gas-mixture and gas-metering assembly. Gas from the supply lines enters the.
HOUGHTO-MIX Coolant Mixing and Supply Unit Rainer Hoerbst
Valves.
Pressure Regulator, Pressure Gauge, Flowmeters
Unit 37: Fluid containment Dr
East Carolina University Compressed Gas Safety Training Program
Sophie Young 21st February 2007
The Anaesthesia Machine
Introduction of fuel feed system
The inventions of John Blease
Chapter 11 Lesson 3 Engine Top End.
Dip. Software based statistics PhD ( physiology), FICA , IDRA
Pressure regulators (reducing valves)
Dip. Software based statistics PhD ( physiology), FICA , IDRA
Parker domnick hunter. Safety of Electrical and
Pneumatic System Conditioning
Presentation transcript:

MAKING HEALTH CARE SAFE ENGINEERING AND SAFE ANAESTHESIA By ; Anyango P. Amoko Deputy Chief Medical Engineering Technologist –MOH, Kenya Presented By; Joseph Nundu SMET, THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

ANAESTHETIC EQUIPMENT Anaesthetic machines dispense a mixture of gases and vapours in varying proportions to control a patient's level of consciousness, analgesia, or both during surgical procedures. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

FUNCTION THE EQUIPMENT Four functions;- (I ) Provides oxygen; (ii) Accurately mixes anaesthetic gases and vapours (iii) Enables patient ventilation; and (iv) Minimizes anaesthesia-related risks to patients and staff. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

ELEMENTS OF TRADITION ANAESTHETIC EQUIPMENT A high-pressure supply of gases. It housed two oxygen and two nitrous oxide cylinders in a wooden box. Pressure regulators on oxygen cylinders and fine-adjustment reducing valves produce a manageable breathing system pressure of 4 bars Flow meters -Control gas flow rate and adjust proportions of gas delivered. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

ELEMENTS OF ANAESTHETIC EQUIPMENT A metal and glass vaporizer bottle for; Halothane, Isoflorane, Safoflorane etc. A breathing system comprising a re- breathing bag, three-way stopcock (APL VALVE) Corrugated hoses and facemask. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

MODERN ANAESTHETIC M/C Have six basic subsystems: Gas supplies: pipelines and cylinders; Gas flow measurement and control (flowmeters); vaporizers; Gas delivery: breathing system and ventilator; scavenging; Monitoring. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

Cylinders Pipeline GAS SUPPLIES THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

Cynders Cylinders usually serve as a backup, should the central gas supply fail They are mounted on yokes attached to the machine or On Y-connection and attached to the machine THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

Cylinder Safety Molybdenum steel alloy construction. This is stronger and lighter than its carbon steel predecessor. Pin-index system. This prevents the accidental connection of a cylinder to the wrong machine yoke. The cylinder valve block bears an arrangement of holes, into which fit pins protruding from the yoke. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

UNSAFE COMMON PRACTICES One oxygen cylinder connected to the equipment-unsafe practice Mixed colors oxygen cylinder with blue and white lining Cylinders not chained on the wall THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

Best and safe practice THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

Cylinder Safety Bodok seals (bonded disk). These are non- combustible neoprene washers with aluminum edges, interposed between the cylinder head and yoke to provide a gas-tight seal. Colour-coding for each gas or vapour Medical Oxygen- Black bottom and white top Blue for Nitrous oxide THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

UNSAFE COMMON PRACTICES tesssss Oxygen cylinder used as nitrous cylinder THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

PIPED GASES Gases are fed into a labeled and colour- coded pipeline distribution network, which terminates in self-closing (Schrader) sockets at the wall. Flexible pipelines connect the terminal outlet to the anaesthetic machine. : THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

PIPED GASES Reducing valves ensure the pipeline pressure of anaesthetic gas services is 4 bar. Flexible pipelines have three components Schrader probe. To prevent misconnection to the wrong gas service, the probe for each gas supply has a protruding indexing collar with a unique diameter, which only fits the Schrader socket assembly for the same gas. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

PIPED GAS SYSTEM THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

PIPED GASES Flexible hosepipe. Originally the hoses were made of black reinforced rubber with short lengths of coloured sheaths at each end. Modern hoses are colour-coded for each gas (oxygen is white; nitrous oxide, French blue; medical air hose, black/white). THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

OXYGEN OUTLET THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

PIPED GASES Non-Interchangeable Screw Thread (NIST) connection to the anaesthetic machine. This ensures a hose connection specific to each gas service. It comprises a nut and probe. The probe has a unique profile for each gas, which fits only the union on the machine for that gas. The nut has the same diameter and thread( Left or Right) for all gas services, but can only be attached to the machine when the probe is engaged.. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

PIPED GASES The term NIST is in fact misleading; the screw thread does not determine the unique fit. A one-way valve ensures unidirectional flow THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

PRESURE REGULATORS Two types Primary Secondary Primary reduces potentially dangerous cylinder pressure to working pressure of 4bars. Secondary regulators set below the anticipated decrease in pressure will make the emergent pressure more uniform THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

GAS FLOW METERS Flow control valves govern the transition from the high to the low-pressure system Reduce the pressure from 4 bar to just above atmospheric as gas enters the flowmeter block. Flowmeter indicate flow rate consist of a needle valve, valve seat and a conically tapered and calibrated gas sight tube containing a bobbin. Flowmeters may be mechanical or electronic. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

GAS FLOMETERS Mechanical Electronic In Mechanical system TYPES OF FLOWMETERS Mechanical Electronic In Mechanical system gas entering the sight tube lifts the bobbin in proportion to flow. The bobbin floats and rotates without touching the sides, giving an accurate indication of gas flow. Flow is read from the top of the bobbin. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

GAS FLOMETERS Sight tubes for each gas are individually calibrated at 20°C and 101.3 kPa; they are non-interchangeable. Tubes have different lengths and diameters, and may have a pin-index system at each end. Tubes are leak-proof because of neoprene washers (O-rings) at both ends of the flowmeter block. The tubes have an antistatic coating on their inner and outer surfaces. This prevents the bobbin from sticking to the tube wall. The bobbin is visible throughout the length of the tube and has vanes to improve its rotation in the gas flow. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

GAS FLOMETERS Features reducing inaccuracy to within 2% include: Sight tubes for each gas are individually calibrated at 20°C and 101.3 kPa; they are non-interchangeable. Tubes have different lengths and diameters, and may have a pin-index system at each end. Tubes are leak-proof because of neoprene washers (O- rings) at both ends of the flowmeter block. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

GAS FLOWMETER THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

GAS FLOMETERS The tubes have an antistatic coating on their inner and outer surfaces. This prevents the bobbin from sticking to the tube wall. The bobbin is visible throughout the length of the tube and has vanes to improve its rotation in the gas flow. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

GAS FLOMETERS Hypoxic mixture prevention devices Is an interlocked oxygen and nitrous oxide flow controls This prevents inadvertent delivery of a hypoxic inspired gas mixture, as the ratio of oxygen to nitrous oxide concentrations never decreases below 0.25. This can be achieved by a mechanical, pneumatic or electronic mechanism. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

VAPORIZERS Vaporizers sit on the back bar of the anaesthetic machine, downstream of the flowmeter block. Manifolds for vaporizers are commonly of the Selectatec type or Similar Interlock type (Cagemount) THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

VAPORIZER-SAFETY MEASURES (i) an interlock to isolate vaporizers not in use; (ii) a clear indication of liquid level; (iii) a non-spill reservoir with up to 180° of allowable tilt; (iv) a keyed-filler or pour-fill systems prevent filling with an incorrect volatile agent and minimize leaks; and (v) an increased wick capacity. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

DOWN STREAM SAFETY FEATURES Oxygen failure warning device. British Standard BS4272 specifies that this alarm should be powered solely by the oxygen supply pressure in machine piping and activated when that pressure decreases below 200 kPa. In case of complete oxygen failure, ventilation with room air is facilitated. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

DOWN STREAM SAFETY FEATURES Spring-loaded non-return valve. This prevents surges in back pressure from damaging vaporizers and flowmeters. Pressure relief valve. This is set at 30–40 kPa to prevent back pressure from damaging vaporizers and flowmeters. Emergency oxygen flush, which is supplied from the high-pressure circuit upstream of the flowmeters and back bar, and provides flow between 35 and 75 litre min−1. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

BREATHING SYSTEMS Either Closed system comprises of Closed or Semi close system Closed system comprises of The carbon dioxide absorber, Adjustable pressure limiting (APL) valve, Reservoir bag, Circuit pressure gauge and A switch to select manual or mechanical ventilation mode. APL (Adjustable pressure limit), Allows excess gas to escape when preset pressure is passed. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

SCAVANGING SYSTEM Disposes the waste gases Modern scavenging has four components for collecting, transferring, receiving and disposal of waste gases from the breathing circuit: The collecting system comprises a gas-tight shroud enclosing the APL valve of the breathing circuit (or expiratory port of the ventilator) utilizing 30 mm conical connections. Some systems (Ohmeda AGS) have an over-pressure relief valve which blows at 1 kPa. The transfer system comprises wide bore tubing leading from the collecting systems to the receiving system. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

SCAVANGING SYSTEM The receiving system comprises a reservoir, air brake, flow indicator and filter. A closed system requires a dumping valve to prevent excessive negative pressure developing (0.5 cm water at 30 litre min−1 gas flow) and a pressure relief valve to prevent excessive positive pressure (5 cm H2O at 30 litre min−1 gas flow). The transfer system comprises wide bore tubing leading from the collecting systems to the receiving system. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

SCAVANGING SYSTEM The receiving system comprises a reservoir, air brake, flow indicator and filter. A closed system requires a dumping valve to prevent excessive negative pressure developing (0.5 cm water at 30 litre min−1 gas flow) and a pressure relief valve to prevent excessive positive pressure (5 cm H2O at 30 litre min−1 gas flow THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

SCAVANGING SYSTEM Disposal systems are active and high flow. The sub-atmospheric pressure required is generated by an exhauster unit, which uses a fan to generate a low pressure, high volume system capable of removing 75 litre min−1 at a peak flow of 130 litre min−1. Other countries use active and low flow systems using a higher-pressure vacuum (USA) or passive Venturi/ejector systems (Scandinavia). Rarely used in EA countries. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012

CONCLUSIONS Problems have been reported with all parts of anaesthesia systems. Pre-use checklists, regular inspections and maintenance can help reduce hazards. THIRD BIANIAL EA HEALTHCARE ENGINEERING CONFERENCE, DAR ES SALAAM, TANZANIA 31ST OCT-2ND NOV.2012