Compact line ‘EW*D~J-’ water-cooled chiller range

Slides:



Advertisements
Similar presentations
Water Source Heat Pump Systems
Advertisements

Pre Sales Dept. HERCULES Solar 26 1 A Condensing floor-standing boilers with built-in solar circuit.
Fan Coil Unit Product Line-up. FCU Home Application Show.
SINGLE SPLIT INVERTER AIR-CONDITIONER
ENERGY SAVING Product Offering COMPRESSOR MARKETING OPPORTUNITIES.
Total HVAC Control from anywhere Easy control that can save a fortune
Setup/Installation/Operation of an Environmental Control Unit (ECU)
Johnson Controls1 YORK Model YVAA Air-Cooled Chillers Variable Speed Screw, tons.
Engineer Presentation
Evolution Daikin Chiller Range
Cooling Only 38MFC/ 40MFC Heat Pump 38MFQ/ 40MFQ
Presentation Technology ORC GREEN MACHINE
Product Introduction.
Mammoth Product Training
Aqualean Product Presentation 1 By Laurent Domenget Product Manager, Rooftop & Packaged Air Units.
RLC-CMS002-E4© American Standard Companies, inc All Rights Reserved Concentration of intelligence, High reliability. Series R TM.
© 2010 McQuay International 1 McQuay Delivered VAV System Product Overview October 2010.
Air conditioning – Refreshes your life Applied Systems DAIKIN Fan Coil Units Comfort Applications >> FWB
Air conditioning – Refreshes your life Mini-Chiller Applied Systems Sales1 EWA(Y)Q-AAV3P Residential Mini-Chiller Heating EWAQ - AA3VP EWYQ - AAV3P Cooling.
EWWD 380-C11 BJYNN Sep-15 Water Cooled Chiller 369 kW ÷ 1050 kW Single Screw Compressor EWWD 380-C11 BJYNN.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
22-Apr-17 EWWD DJYNN.
22-Apr-17 EWWD340-C19CJYNN.
22-Apr-17 EWAD AJYNN.
EWWD DJYNN Sep-15 Water Cooled Chiller 166 kW ÷ 604 kW Single Screw Compressor EWWD DJYNN.
Flooded Screw Chiller FWSF Electronic Expansion Valve Condenser Evaporator Control box compressor Flooded Screw Chiller - FWSF.
Applied Systems News FWEC*A Rudolf BARET HEISSIG.
/ 1 ERA A chiller to suit everyone. Air cooled water chillers Free-cooling chillers Air/water heat pumps.
Product Presentation 2007 SKY AIR Launch of new Non-Inverter + Duct (R22) series.
BCWC Water-cooled water chillers with centrifugal compressor/s
Schneider Electric: Total Cooling Solutions for Data Centers
1 BREC Air-cooled water chillers BREF Air-cooled water chillers with free-cooling system 1602A A A A A 3202A A A -
Serial Transmission System Series EX510 BackgroundFeaturesTechnical detailsApplications.
MULTISTACK WORLD-WIDE HEADQUARTERS SPARTA, WISCONSIN.
Introduction to Energy Management. Week/Lesson 12 Advanced Technology for Effective Facility Control.
CUE – Make Any Pump an E-Pump
Large Tonnage Chiller WC Screw.
New product introduction:
Evolution Daikin Chiller Range
Status of the Marco chiller and Marco capacity analyses Bart Verlaat, Lukas Zwalinski, Maciej Osterga, Jan Godlewski MPI Munich,1 March.
2016 Chiller New Products Presentation.
ESX10-T Electronic Circuit Protectors with Hazardous Area approvals.
Air Cooled Chillers with High Speed Centrifugal Compressors.
I-RACH range I-RACH range I-RACH range I-RACH range High efficiency air/water heat pump with INVERTER scroll compressor Range Modularity Components Highlights.
CHIGO HVAC Product Introduction.
UniTrane™ Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
10 12 and 14 TR Advanced Glycol Chiller
C1300 advanced circular chart recorder
Wega & Wega Power chilled beams
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
UNICOS: UNified Industrial COntrol System CPC (Continuous Process Control) Basic course SESSION 3: PLC basics UCPC 6 UNICOS-Continuous Process Control.
Chillers for Tomorrow… Today
WELCOME Indoor Chillers.
10TR Nominal Glycol Chiller
DC Inverter Air-cooled Chiller Aqua Tempo Super II Series
New Air Cooled Scroll Chiller
Trane Care Energy RTHD Adaptive Frequency Drive retrofit.
General Training Session
WELCOME Indoor Chillers.
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Title RTWD Water-Cooled Chillers subtitle START
Total HVAC Control from anywhere Easy control that can save a fortune
Dunham Bush Air Cooled Package
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
NRL NRL - Welcome to the NRK Sales Training Program
NRL NRL - Welcome to the NRL Sales Training Program
The efficient interface for lighting control
Presentation transcript:

Compact line ‘EW*D~J-’ water-cooled chiller range - Product presentation - Applied Systems - Strategic Marketing Daikin Europe NV

CONTENTS 1. What’s changing? 1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range 2. What are we going to offer? 2.1 Features & benefits 2.2 Capacity classes 2.3 Operation range 2.4 Energy efficiency 2.5 Dimensions 2.6 Connections 2.7 Options 3. Conclusion

Chapter 1 --------------------------------- What’s changing?

1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range Current product portfolio: COOLING CAPACITY (kW) 50 100 250 500 750 1000 1250 1500 2000 R-410A & 407c Hydrocube EWWP012-065KBWN (incl. EWLP) EWWQ~B- R-134a EW*D~MB REPLACEMENT EW*D~J- EW*D~G- EWWD~H- (Flooded technology) EW*D~I- INVERTER EWWD~FZ DWSC/WDC (Centrifugal Chiller) (DWSC up to 4.500 kW) (DWDC up to 9.000 kW) 4

1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range Current range overview: MODEL CHANGE! Model change includes: 1 Complete range will feature: - extended capacity range - new compressor - new controller 2 Complete range will be updated with regard to: - option configuration - warranty 1year standard instead of 3 extendable up to a maximum of 4 years warranty applicable on parts only

1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range Product Water-cooled chiller with single screw compressor Refrigerant R-134A Series name EW*D~J- ¹ Cooling capacity From 120 kW up to 570 kW (nominal conditions) Circuits 1/2 circuits (1/2 compressors) Efficiency versions S Standard efficiency Sound versions S Standard sound New range overview: Note ¹ Also available as condenserless series ‘EWLD~J-’

1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range New range overview: Product line-up: ‘EW*D~MB’ replaced by ‘EW*D~J-‘ range Current situation New situation

1.1 Replacement of EW*D~MBYNN 1.2 Position in our W/C range Product positioning: WATER COOLED EW*D~G- EWWD~H- NEW Direct expansion EWWD~FZ Flooded EW*D~I- EW*D~J- DWSC/DWDC EWWQ~B-

Chapter 2 --------------------------------- What are we going to offer?

2.1 Features & benefits wide capacity range: 120 – 570kW 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options wide capacity range: 120 – 570kW compact design to allow easy indoor installations or retrofit operations availability of both standard and condenserless units high energy efficiency (EER up to 4.41, ESEER up to 5.37) upgrade of chiller controller to Microtech III easy integration with control systems (BMS, sequencing panels) extensive option list, including heat pump version

extended capacity range 2.2 Capacity classes 2.1 Features 2.2 Capacity 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Standard unit: ● Standard efficiency – standard sound Current situation New situation extended capacity range additional sizes

extended capacity range 2.2 Capacity classes 2.1 Features 2.2 Capacity 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Condenserless unit: ● Standard efficiency – standard sound Current situation New situation extended capacity range additional sizes

Standard efficiency – standard sound 2.3 Operation range 2.1 Features 2.2 Capacity 2.3 Operation 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Standard unit: Standard efficiency – standard sound Operation with Glycol ICE mode Operation with Glycol (below 4°C ELWT) = Units should not be able to reach the minimum capacity when working in part load

Standard efficiency – standard sound 2.3 Operation range 2.1 Features 2.2 Capacity 2.3 Operation 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Condenserless unit: Standard efficiency – standard sound Operation with Glycol ICE mode Operation with Glycol (below 4°C ELWT) = Units should not be able to reach the minimum capacity when working in part load

2.4 Energy efficiency levels 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Standard unit: New range Current range EER comparison Up to 8% increase in EER

2.4 Energy efficiency levels 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Standard unit: New range Current range ESEER comparison

COMPACT LINE! 2.5 Unit dimensions Current situation New situation 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Dimensions Dimensions of the new units will be the same as the current EW*D~MB range COMPACT LINE! Current situation New situation

2.6 Connections Connections: Hydraulic side (dual compressor unit) 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Connections: Hydraulic side (dual compressor unit) Note 1 – Units are mechanically linked Note 2 - Connection pipes are NOT provided by Daikin Evaporator water IN Condenser water OUT Condenser water IN Evaporator water OUT - Evaporator water inlet/outlet: 76,2mm - Condenser water inlet/outlet: 4’’ (2½’’ on size 120)

2.6 Connections Connections: Electric side (dual compressor unit) 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Connections: Electric side (dual compressor unit) One Microtech III controller on the superior unit (master) is connected through RS485 with control modules on the lower unit (slave) Communication through cables between the two units Main switch Cables IN (side entry)

Microtech III controller (Siemens) 2.6 Connections 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options Connections: Electric panel Current situation New situation Microtech III controller (Siemens) Microtech II controller (Carel) Emergency stop (standard) Emergency stop (standard) Main switch (standard) Note: Main switch available as option

2.7 Options & accessories A) Options Compared to MB-series: 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options A) Options 1) Standard factory mounted The base model will include here below standard factory mounted options: Compared to MB-series: electronic expansion device: STD suction shut off valve: STD main switch: STD compressor fuse protection: STD

Extensive list of options 2.7 Options & accessories 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options 2.7 Options 2.7 Options A) Options 2) Options on request Below mentioned options will be available for the new ‘EW*D~J-‘ range: Current situation New situation Extensive list of options

2.7 Options & accessories B) Accessories 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options B) Accessories The R-134a ‘EW*D~J-‘ range will feature the new Microtech III controller Main features: ▫ Unit controller fully programmed and engineered by Daikin on Siemens hardware ▫ P.I.D. logic (proportional, integrative, derivative) ▫ Easy visual interface with 4 rows display and 3 keypads ▫ Push and roll navigating wheel ▫ Modular control solution: ▫ Freely programmable controllers ▫ Extendable with additional I/O modules ▫ Extended temperature range (-40ºC up to +70ºC) ▫ Field installable COMM modules (integration) ▫ Advanced (remote) servicing possibilities Microtech III

2.7 Options & accessories Current situation New situation 2.1 Features 2.2 Capacity 2.3 Operation 2.4 Efficiency 2.5 Dimensions 2.6 Connections 2.7 Options 2.7 Options B) Accessories Below accessories will be available: Current situation New situation

Chapter 3 --------------------------------- Conclusion

Superior control logic Small package, great chiller The new compact line ‘EW*D~J-’ chiller range features compact design, maximum efficiency and superior control logic, offering flexible solutions for a wide range of comfort and process applications Application flexibility Easy indoor installation & retrofit operation The EW*D-J- series is available in a wide range of capacities (120 - 570kW), allowing project solutions for an extensive range of applications. Water cooled units are typically intended for indoor installation and operation, resulting in acoustic isolation and also zero impact on the building layout. Thanks to the compact design, the EW*D-J- series allow easy indoor installations and retrofit operations. Superior control logic New MicroTech III controller provides easy to use control environmental and an easy interface with LonWorks, BACnet, Ethernet TCP/IP or Modbus communications