Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine.

Slides:



Advertisements
Similar presentations
Sprinkler Systems and Standpipe Operations
Advertisements

HH HOUSTON FIRE DEPARTMENT PUMP OPERATOR PROGRAM
Fire Apparatus Pump Theory
Dennis Fire Appliances Operations & use. PTO Step 1 Move slide cover towards the drivers seat to lock out the gearbox Step 2 Select drive on the gear.
Fuel System The fuel system supplies the air and fuel necessary for an engine to produce power. The fuel system includes: Air Cleaner Fuel Supply Carburetor.
Morgan City Rentals Diesel Jet Pump 6 x 6 Peerless Safe Operating Practices and Procedures.
Adapted From Cody Fire School Presentations Amsterdam Fire Regular Fire Training February 16, 2009.
Power Brake Systems.
CAFS On-Line Orientation
Tandem Pumping Video. INITIAL SIZE-UP When approaching the structure note the location of the FDC, Hydrant and Building Access.
Nozzle Pressure. Designed Nozzle Pressures  Smooth Bore Nozzle - Handline 50 PSI  Smooth Bore Nozzle - Master Stream 80 PSI  Combination Nozzle - (all.

State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Augmenting Fire Standpipe Systems
For The Driver Operator
Water supply and drafting. Objectives Understand and be able to demonstrate the different hydrant lays and hook ups Explain/demonstrate how to operate.
LoneStar Fire Specialties
Fire Pump Theory TCFP Section Part 3 Operations.
Pumping Apparatus Driver/Operator
CVFD Training – Water Supply SFFMA Training Objectives: –
HH H OUSTON H OUSTON F IRE F IRE D EPARTMENT P UMP P UMP O PERATOR O PERATOR P ROGRAM VAL JAHNKE TRAINING FACILITY.
Fire Streams SFFMA Training Objectives: –
Dennis Sabre Fire Appliances
FIREFIGHTER I LESSON 15. SPRINKLER SYSTEM DESIGN AND OPERATION Series of sprinklers arranged to automatically distribute enough water to extinguish or.
HYDRAULICS.
Pumping Apparatus Driver/Operator
Pumping Apparatus Driver/Operator
Pumper Operations n Why do we need to be concerned about being good pump operators? n When we are good pump operators the personnel working the hand lines.
Pumping Apparatus Driver/Operator
Pump types and theory.
1402 Hybrid Firefighter I 6 th Edition Chapter 14 Water Supply.
C L A S #4 Driver Operator Refresher Training.
Pumping Apparatus Driver/Operator
Task Force-7 Engine 14 Engine 13 Batt. 2
Intermediate SFFMA Objectives: – Hrs received.
PRESSURE REGULATING DEVICES By: Sgt. Larry Baker FF/Medic Len Clowser FF/EMT Terry Orndorff.
Learning Objective 1 Explain the ways water supply system components are used by firefighters.
Fire Pump Functions The main function of a fire pump is to increase the pressure of the water that flows through it. Inadequate or nonexistent municipal.
Instructor Lee Lautzenheiser
FIREFIGHTER II LESSON 12. TYPES OF VALVES Ball — Ball — Controls nozzle flow and pump discharge rates Gate — Gate — Controls hydrant flow Butterfly.
1402 Hybrid Firefighter II 6th Edition Chapter 15 — Fire Hose South Carolina Fire Academy.
Left side compressor behind Left control box Right side compressor behind Right control box.
Pumping Apparatus Driver/Operator
Pumping Apparatus Driver/Operator
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Select and deploy the appropriate hose lines to accomplish fire confinement and extinguishment.
TIDBITS Hose made pryor to July 1987 will be taken out of service Hose that is frozen will be service tested again Color’d Hoses All test gauges.
Water Supply Skill Drills.
MODULE:3 FIRE CONFINMENT AND EXTINGUISHMENT. OBJECTIVES Module 3 Overview Select and deploy the appropriate hose lines to accomplish fire confinement.
Mahoney, Hannig, Fire Department Hydraulics, 2nd Ed. ©2009 by Pearson Education, Inc., Upper Saddle River, NJ Fire Department Hydraulics Chapter 8 Required.
TANKER OPERATIONS Long Laneway – 1 st arriving pumper P-1 FIRE BLDG House?= 38mm x2 + 65mm backup line Barn? = consider 2- 65mm right away Lay a Hi-Vol.
1 HVACR318 – Refrigeration II Diagrams. 2 Hooking up Gauges on Suction and Discharge Lines.
Firefighter III Module B Water Supply (4-19) (4-19)
Achieving Maximum Flows The Water Triangle.... The FIRE Tetrahedron.
15 Water Supply. 15 Objectives (1 of 2) Discuss rural water supplies. Describe how portable tanks are used to supply water for firefighting. Describe.
STEP 1 Locate the transmission cooler line connection on the vehicle. Identify the correct adapters to be used by referring to the vehicle application.
Apparatus Testing Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
 All fire pumps are rated by drafting through 20 ft. of hose with 10 ft. of Lift  Theoretical Lift = 14.7 psi x 2.3 ft/psi = 33.8 ft.  Maximum practical.
Water Shuttle Operations
Snohomish County Training Officers 2013Q3. Drafting Need for drafting operations Set up and resource considerations Shuttle operations Jet Siphon Operations.
Relay Pumping Operations Sugar Land Fire Department Driver/Operator-Pumper Academy Spring 2003.
Operating Fire Pumps Sugar Land Fire Department Driver/Operator—Pumper Academy Spring 2003.
ATP FOAM SYSTEM Engine 438 Ansul / Rockwood Model B2 400 GPM Around The Pump Foam System.
Water Supply (Fire Fighter I)
2013Q1.
OBJECTIVES Describe the operation of a pressure-differential switch and a brake fluid level sensor switch. Describe the operation of a residual check valve.
Essentials of Fire Fighting
State of Georgia BASIC FIRE FIGHTER TRAINING COURSE
Bella Vista Fire Department Procedures on Sprinkled Buildings
Presentation transcript:

Dual Pumping Definition: An operation where a strong hydrant is used to supply two Engines by connecting the Engines intake-to-intake. The second Engine receives excess water not being pumped by the first Engine, which is directly connected to the water supply source.

Dual Pumping Operations: Step 1: Engine 1 connects to the hydrant steamer connection using LDH. This Engine then pumps water through its line(s) to the fire. Eng 1

Dual Pumping Operations: Step 2: Engine 2 is positioned intake to intake with Engine 1. The hydrant is closed down until the compound gauge of Engine 1 reads near zero. (Engine 1 throttle may need adjusting). This makes the volumes of discharge and intake equal, so the cap of the unused intake can be removed. {If Engine 1 is equipped with a gate valve on its unused intake, the hydrant need not be turned off.} Eng 1 Eng 2

Dual Pumping Operations: Step 3: Engine 2 is connected by Hard suction to the unused steamer intake of Engine 1. Step 4: Hydrant is opened completely. Eng 1 Eng 2

Dual Pumping Operations: Step 5: Engine 2 pumps water through its line(s) to the fire. Its supply is the water not being used by Engine 1 that is passing through Engine 1’s pump. Eng 2 is getting the left over hydrant intake pressure Eng 1 Eng 2

Tandem Pumping Definition: A short relay operation in which the pumper taking water from the supply source pumps into the intake of the second Engine. The second Engine boosts the pressure of the water even higher. This method is used when pressures higher than the capability of a single Engine are required.

Tandem Pumping The higher pressures result from the fact that the pumps are actually acting in series.

Tandem Pumping Tandem Pumping Operations: 1. Attack engine short distance from a hydrant. 2. 2nd Engine placed directly on hydrant to support supply lines to attack engine. 3. May also be used to overcome friction loss problems that occur in large sprinkler or standpipe systems and in long hose layouts. 4. Caution should be used as to not over pressure at which the hose is annually tested.

Tandem Pumping 300 PSI needed 70 psi + 150 psi = 220 psi 80 psi 300 psi You are making a 2 stage pump, using 2 engines with single stage pumps

Relay Pumping Definition: The process of using 2 or more Engines to move the water through hoselines over a long distance by operating the Engines in series.

Relay Pumping As soon as the source engine gets water, advance the throttle to the calculated pressure. At the same time allow water to waste through an open discharge (dump line). Dump discharge

Relay Pumping When the first relay engine is ready for water, the operator for the source engine opens the valve for the supply line, closes the open discharge (dump line) stopping the waste flow, and starts water moving toward the fire scene. Source Engine 1st Relay Engine Stop Dump discharge Dump discharge

1st Relay Engine Stop Dump discharge 2nd Relay Engine Dump discharge Relay Pumping When water reaches the first relay engine, it is allowed to flow through the uncapped discharge (dump line) as waste water until air is forced out. The engine is then engaged and the throttle advanced to establish the specified pressure while adjusting the valve on the uncapped discharge (dump line) to maintain 50 p.s.i. on the intake. Source Engine

2nd Relay Engine Stop Dump discharge Fire Scene Engine Relay Pumping Each engine in turn duplicates the previous steps until water arrives at the fire. The engine at the fire establishes the pump discharge pressure needed to provide the required nozzle pressure on all lines. All engines will set relief valves or pressure governors. 1st Relay Engine Source Engine

Relay Pumping Any adjustment of pressure at relay engines can only be made when gauges readings clearly indicate changes are necessary. The engine at the fire is shut down first by slowly decreasing pressure until the pump can be disengaged.

Relay Pumping Water is allowed to waste through the uncapped discharge (dump line) once again. Each engine in turn reduces pressure gradually and allows the water to waste after the pump is disengaged. Good communications is a must for a successful relay operation

Relay Pumping Source: IFSTA Fire Department Pumping Apparatus