Increase your efficiency with Schneider Electric

Slides:



Advertisements
Similar presentations
Packaged Terminal Air Conditioners
Advertisements

MEDIUM VOLTAGE VFD MOTOR CONTROLLER Liquid Cooled Components Active Front End - No Transformer 3300 – 6900 VAC 700 – 2500 HP Contact:
ABB standard drive Enhanced ACS550
G.E. UPS Productline.
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
Total HVAC Control from anywhere Easy control that can save a fortune
POWER ELECTRONICS Multi-Step VSI vs GTO CSI. Power Electronics España S.L. © reserves the right to modify the content without prior notice 01 GTO CSI.
Variable Frequency Drives VFD Basics
LP33 Series UPS kVA 400Vac/CE
Franz Frank (ABB Switzerland Ltd) – PowerGen Europe 2010
© ABB-EWEC 2006 ATHENS /03/06 EWEC 2006 Athens The Challenges of Offshore Power System Construction Peter Jones Lars Stendius ABB.
PSI Pump Systems Inc. 1(800) PSI Pump Systems Inc. 1(800) Variable Frequency Drives Presented by PSI Pump Systems Inc. “ Your Solutions.
Environmental solutions from Franklin Electric Oman Energy & Water Exhibition May 20 th, 2015 Presented by: Hisham Al Shehabi.
Power Converter Systems
Steve Craker K-12 Team Lead Geoff Overland IT and Data Center Focus on Energy Increase IT Budgets with Energy Efficiency.
FUJI Medium Voltage IGBT Inverter
© BA Electrical Machines BU Electrical Machines General presentation.
1 Electronic Soft Starters How and Why they Work, and What they can do for You. Fairford North America.
Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Direct-to-Drive Technology Product Feature Overview.
Confidential & Proprietary. What happens when Wind /Solar do not meet requirements? What next?
1 EE462L, Fall 2011 Motor Drives and Other Applications.
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
Air conditioning – Refreshes your life EWTP MBY Applied Systems Sales1 EWTP-MBYNN Air-cooled Heat Recovery.
VLT ® Low Harmonic Drive. | Property of Danfoss Drives A/S | Tuesday, 15 September 2015 | 2 Acoustic noise Planes, trains, automobiles, busses, construction.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
© BA Electrical Machines BU Electrical Machines General presentation.
Flooded Screw Chiller FWSF Electronic Expansion Valve Condenser Evaporator Control box compressor Flooded Screw Chiller - FWSF.
Copyright © 2011 Rockwell Automation, Inc. All rights reserved. Insert Photo Here OneGear™ SMC™ Flex Controller kV.
Melo EDP PT Session 2 – Block III – Question 9.1 Barcelona May EDP Distribuição Energia ASD Immunization to Voltage Dips Case Study in Cement.
BCWC Water-cooled water chillers with centrifugal compressor/s
PowerIT Air Insulated Cubicle Uniswitch
© Copyright year ABB. All rights reserved /6/2016 Insert image here ACS800 regenerative drives Product presentation.
Altivar 32 So slim, So smart!
Wholesale Medium Voltage Drives
2016 Chiller New Products Presentation.
UPS SG-CE Series 300 kVA. SG-CE Series kVA S1 Sales presentation SAP_SGS_XCE_M16_M30_1GB_V011.ppt 2 Product portfolio CE Marked, 3x380/400/415V.
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
ENERGY CONSERVATION IN MOTOR SYSTEMS. Introduction 2.
Copyright © 2009 Toshiba International Corporation. All rights reserved. Hx7+Pack Drive Severe Duty Adjustable Speed Drive Prepared By: ASD Marketing.
Altivar Process Unique Value Propositions. Drives vision Extend drives sales from Transactional to Solutions & Segments Best in Class Products Solutions.
Review of ABB Drives. 1.Direct torque control explains what DTC is; why and how it has evolved; the basic theory behind its success; and the features.
1 Altivar Machine Industrial Machines Altivar Machine ATV320 Book ATV320 Compact ATV340 ATV12.
ELECTRICAL DEPARTMENT ELEMENT OF ELECTRIC DESIGN
CANOVATE MOBILE (CONTAINER) DATA CENTER SOLUTIONS
FUJI ELECTRIC CO.,LTD Power Electronics Business Group Drive Division
Energy Efficient Motors and Variable Speed Drives
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
The New C55* CPVSd 10-20hp People. Passion. Performance.
Auxiliary power supply (APS) Hossein Harimi 2014
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Speed control of three phase induction motor
MEDIUM VOLTAGE APPLICATIONS.
Introduction to Electrical Drive
Yaskawa Electric America on Variable Torque Loads
AdaptaPAK The sustainable, energy-efficient outdoor refrigeration solution.
SPOC Automation and BECI- who are we?
Five level diode clapmed inverter
Power distribution and UPS in a single, compact system
High Pressure screw compressor
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
Robicon Perfect Harmony.
The evolution of pipe cutting Patented products Designed in Finland Pipe Cutting System.
Vibration Monitoring System M14
VITALITY Large Splits Johnson Controls PowerPoint Guidelines | July 21, 2009.
Direct Current (DC) Data Center
Title RTWD Water-Cooled Chillers subtitle START
Total HVAC Control from anywhere Easy control that can save a fortune
Solar Drive Enclosure and ATV312 Solar Drive
The smart choice for demanding motor switching
Liebert DSE High efficiency thermal management
Presentation transcript:

Increase your efficiency with Schneider Electric MV DRIVE SYSTEMS Increase your efficiency with Schneider Electric Confidential Property of Schneider Electric

Altivar 1200 THE PRODUCT 2

Altivar 1200 Motor FRIENDLY and LOW Harmonic Technology Multi-level architecture Compact & environment friendly Innovative technology : Example of 6kV drive circuit 3

Altivar 1200 Multilevel architecture Output Voltage by Number of Cells 3,3kV 3 cells 4,16kV 4 cells 6,0kV 5 cells

Simple, Convenient, Reliable Altivar 1200 Simple, Convenient, Reliable Reliable Automatic Contactless Cell Bypass for a better reliability Convenient Easy Front access design for Control & Transformer maintenance Combined Control & Transformer cabinet Separated airflow cooling Modular inverter stage cubicle for fast maintenance Complete Well equipped as a standard : UPS, LS, lightening, Security screw, door locks… Control cabinet optimized for an Easy Customization 5

Altivar 1200 KEY FEATURES 6

Reduced Harmonic Technology Altivar1200 Key Features Reduced Harmonic Technology Input voltage (Green) and Current (Orange) Smooth to public grid 30 pulse THDi < 3% 36 pulse THDi < 2% 54 pulse THDi < 1% pF> 0.96 over the speed range Waveforms (line side) 7

Reduced Harmonic Technology Altivar 1200 Key Features Reduced Harmonic Technology LOW HARMONIC or negligible harmonics All standards like IEEE 519.1992 inherently fulfilled Save installation costs because no additional filters needed (CAPEX) Save costs of losses in your transformers and grid due to low harmonics (OPEX) 8

Motor FRIENDLY Great Waveform Altivar 1200 Key Features 9 JUST SHOW Voltage (Green) and Current (Orange) on motor side 9

Motor FRIENDLY ATV1200 Key Features No dU/dt peaks stressing motor insulation No output current harmonics are increasing rotor losses THDi < 2% 10

Motor FRIENDLY ATV1200 Key Features Long cable distances allowed Run EXISTING old motor Run all brands of motors Long cable distances allowed Up to 1000m and more Save money with energy saving projects at your old motor Save money with standard motor 11

Motor FRIENDLY Altivar 1200 Key Features Perfect waveform and input transformer avoids bearing currents Transformer and multilevel is the only architecture to cut common mode voltage effects 12

..at Pumps & Fans (ROI < 2 Years) Altivar 1200 PERFECT for OLD Motors ..at Pumps & Fans (ROI < 2 Years) 13

Premium & Standard No AUX. supply for fan needed !! …..saves CAPEX…. Altivar 1200 Premium & Standard Different Transformer Execution means: Providing cost effective execution with Standard Transformer selection No AUX. supply for fan needed !! …..saves CAPEX…. 14

Solid State Devices do work under all environmental conditions Altivar 1200 CONTACTLESS SYMETRICAL CELL BYPASS Solid State Devices do work under all environmental conditions E.g. a contact will not be reliable in a cement factory if 2 years not operating Keep operating with 75% of speed but with 100% current when using the Option Cell Bypass. We can offer 100% voltage with the Option N+1 power cells. 15

Altivar 1200 Easy to operate 16

KEY Features & Options Altivar 1200 All Field Busses to =SE= PLC No PC needed Key Interlock UPS inside as standard Internal Fan supply saves aux. supply (CAPEX) Synchronous Transfer 17

Altivar 1200 APPLICATIONS 18

10250 installed Units 12500 MW installed power MV Drive Offer Schneider Electric as Key Player 10250 installed Units Key segments : O&G, Mining, Power Gen. Metal, Water Installed based in more than 25 countries 12500 MW installed power Energy Managment expertise Karim to present Application Process knowledge

12050kW 11kV Gas Compressor Starters Place: Badra Oilfield, IRAQ Customer: M.A.N Turbo & Diesel Application: Centrifugal Compressor Customer requirement: Synchronous Transfer Multiple ETO requirements according O&G standards Product: ATV1200 A14900 1111 A4S Contact: Schneider Electric Germany Must be explained

1500kW 3300V District Heating Line Pumps Place: ROTERDAM Customer: AVR Application: Line Pumps Customer requirement: Reliability Product: ATV1200 A1830 3333 A4S Contact: Schneider Electric Netherlands Must be explained

1750kW, 780kW 6,6kV Loading Pumps Place: Pengerang, Malaysia Customer: VOPAK, Dialog, Petronas Application: Loading / Unloading Pumps Customer requirement: 6,6kV, low harmonic Product: ATV1200 A2020 6666 A3S Contact: Schneider Electric Kuala Lumpur Must be explained

Overland conveyor Place: Australia Customer: Rio Tinto Mesaa, WA Application: Conveyor twin drive Customer requirement: Multi drive with 1 x “synchronizer” Master and torque controlled slaves Product: 3,3kV - 2 x 800kW - 1 x 400kW Contact: Schneider Electric Beijing Must be explained