Energy Codes and the Building Envelope

Slides:



Advertisements
Similar presentations
Exterior Window and Door Frames
Advertisements

BUILDING ENERGY CODES UNIVERSITYwww.energycodes.gov/BECU 1 BUILDING ENERGY CODES UNIVERSITY ANSI/ASHRAE/IES Standard Scope and Application April.
U.S. Department of Energy Building Energy Codes Program
Chapter 18 Windows and Doors.
Energy Codes and the Building Envelope
Presents 2012 Revisions to the NC Energy Code For Residential Building started after March 1, 2012.
Framing Assignment 4 Print SetSingle Family Dwelling SFD.
INSULATION THICKNESS CALCULATOR. ENERGY EFFICIENCY PERFORMANCE PRINCIPLES THE BUILDING ENVELOPE Components that constitute the building envelope are:
Energy Savings Impacts of the Advanced Energy Design Guide: Small Office Buildings Bing Liu, P.E. Research Engineer Pacific Northwest National Laboratory.
eQuest Quick Energy Simulation Tool
Guidelines and Required Codes That Affect Building Design
Heating and Air Conditioning I Principles of Heating, Ventilating and Air Conditioning R.H. Howell, H.J. Sauer, and W.J. Coad ASHRAE, 2005 basic textbook/reference.
“Do not take anyone’s advice as to how this building should be assembled.”
Manitoba Energy Code for Buildings 2013
Building Construction A fire resistive rating (FRR) is given in minutes or hours and relates to how long it takes to burn through a given material. Expressions.
Chapter 6: Windows and Doors To be used with the Guide to Building Energy Efficient Homes in Kentucky.
Emerging Standards and their effect on Exterior Continuous Insulation in Commercial Wall Construction.
Oklahoma Uniform Building Code Commission IRC Building Subcommittee Presentation to Commission November 17, 2010.
Common Architecture Terms. Fenestration The design and placement of windows in a building.
Presented by: Energy Systems Laboratory (ESL) Texas A&M University Funded by: State Energy Conservation Office (SECO) US Department of Energy (DOE) The.
Heat Loss & Gain Calculations 1. How Heat Moves in Homes Conduction is the transfer of heat through solid objects, such as the ceilings, walls, and floors.
Tom Andrew Henry Poor Lumber/ Homeworks.  Objective: after this brief you should have a better understanding of ; 1. Materials that don’t primarily affect.
Windows. Huge variety of available building components and several important roles Thermally most important they admit solar radiation Advantageous in.
Massachusetts “Stretch” Energy Code Marc Breslow Executive Office of Energy & Environmental Affairs.
Adriana Galue Wolfgang Custom Finishes HOME ENERGY STATS Biggest energy consumers Space heating – 34% Appliances and lighting – 34% Refrigerator.
MECHANICAL ASPECTS OF MICHIGAN UNIFORM ENERGY CODE MIAM DOHERTY INN CLAIRE, MICHIGAN MARK RILEY.
Arkansas Energy Code 2004 Compliance
1 Connecticut’s New Energy Code Connecticut ASHRAE Tech Session October 13, 2011 Frederick F. Wajcs, Jr. Senior Energy Engineer Connecticut Light and Power.
IECC, REScheck, and COMcheck Mark Halverson Pacific Northwest National Laboratory PNNL-SA
Brought to you by: Connecticut Energy Code Frederick F. Wajcs Senior Energy Engineer Northeast Utilities February 10, 2011.
Architectural CAD I – IM230 Vocabulary. GROUP 3 Vocabulary.
Development of the Envelope Criteria Merle McBride, Ph.D., P.E Senior Research Associate Owens Corning ASHRAE Representative At Large Orlando, FL February.
C A L I F O R N I A E N E R G Y C O M M I S S I O N California Energy Policy: Zero Net Energy Homes in 2020 Martha Brook, P.E. High Performance Buildings.
North Carolina State Buildings Efficiency Conference
Conservation and Environmental Design and Construction
Chapter 23 Plumbing Systems. Objectives After reading the chapter and reviewing the materials presented the students will be able to: Identify several.
Energy Conservation February 8, Steve Wilson, MBA, CEM, CDSM, BEP The Energy Guy.
HVACR416 - Design Heat Loss / Heat Gain Part 1. Why? The primary function of Air Conditioning is to maintain conditions that are… o Conductive to human.
PowerPoint ® Presentation Unit 52 Thermal Insulation and Other Insulating Methods Thermal Insulation Exterior Insulation and Finish Systems (EIFS) Roof.
Building Envelope. Physical separator between interior and exterior spaces – Walls – Floors – Roofs – Fenestrations (any opening in the structure) – Doors.
VENTILATION AND FENESTRATION
Stretch Code Informational Session March 16, 2011.
ENERGY SYSTEMS LABORATORY ABOVE CODE ENERGY ENHANCEMENT PROJECT for The City of Arlington ENERGY SYSTEMS LABORATORY Texas Engineering Experiment Station.
Part 1 Technician’s Guide & Workbook for Duct Diagnostics and Repair.
Stretch Code Informational Session February 16, 2011.
2015 International Energy Conservation Code
Heat Loss and Gain Civil Engineering and Architecture
Building Environmental Systems
Truss Heel Heights and Energy Code Requirements
WDMA Technical Conference Chicago, IL 28 June 2016
Use of Cantilevered Sill Plates with MPCWT to Align with Varying Thicknesses of Exterior Sheathing Overview Revised 3/22/2017.
Heat gain and heat loss in buildings
Heat Loss and Gain.
Heat Loss and Gain Heat Transfer Winter Heat Loss Summer Heat Gain
Land Use and Regulations
Building Construction
Introduction to Building Codes
Introduction to Building Codes
Arch205 building construction Windows- glazed curtain wall, skylights
Energy Codes and the Building Envelope
Land Use and Development Regulations
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Common Components of a Traditional Wood Framed Building
Heat Loss and Gain Civil Engineering and Architecture
DOER recommendations for BBRS
BUREAU OF STANDARDS JAMAICA
© OnCourse Learning.
Heat Loss and Gain Heat Loss and Gain
Heat Loss and Gain Heat Loss and Gain
Presentation transcript:

Energy Codes and the Building Envelope Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Energy Codes and the Building Envelope

Goal of Energy Efficient Design Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Goal of Energy Efficient Design Conserve Natural Resources Save the Environment Preserve Ozone Layer Create Healthier Living Spaces Reduce Costs 2

Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities A Few Acronyms ASHREA = American Society of Heating, Refrigerating, and Air-Conditioning Engineers ICC = International Code Council IECC = International Energy Conservation Code

Codes, Standards, and Model Codes Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Codes, Standards, and Model Codes Code Specifies how the building must be constructed Example: Indiana State Building Code Standard Describes how a building should be constructed Example: ASHRAE Model Code Recommendation for a code that may be adopted by a state or local jurisdiction Often adopted and modified by local jurisdictions Examples: IBC, IECC

Commercial Energy Usage Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Commercial Energy Usage Office, retail, and service buildings are the largest consumers of energy in the United States About half of this energy is consumed by lighting Energy Codes and Standards set a minimum level of energy performance with which the building must comply

Commercial Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Commercial Energy Codes Commercial energy codes apply to all buildings EXCEPT: One- and two-family residential buildings Multi-unit residential buildings three stories or less in height

Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Energy Codes Codes and standards may be enforced at the state, local, or jurisdictional level Voluntary Energy-Efficiency Programs Home Energy Rating System (HERS) ENERGY STAR Good Cents LEED

Commercial Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Commercial Energy Codes A few states have adopted the most recent versions (dark green) Some states have no statewide energy code (white) Most have adopted an older version of ASHRAE/IECC but will typically update as code requirements periodically change Most recent standard/model code is ASHRAE 90.1-2007/2009 IECC Courtesy US DOE

We’ll Look at ASHRAE/IESNA Standard 90.1-2007 Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities We’ll Look at ASHRAE/IESNA Standard 90.1-2007 Chapter 5 of the IECC General Prescriptive Approach Use for ≤ 40% of gross wall area in vertical fenestration Use for ≤ 3% of gross roof area in skylights

2009 IECC Climate Zones Keystone Library Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities 2009 IECC Climate Zones Keystone Library The Keystone Library Renovation project in Noblesville, Indiana, is within Zone 5 of the 2009 IECC Climate Zones. Code requirements are based on climate zones

Commercial Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Commercial Energy Codes COMMERCIAL Building Envelope Lighting Mechanical Service Water Heating Commercial energy codes address four broad categories: building envelope, lighting, mechanical (HVAC), and service water heating. We will concentrate on the energy code requirements for the building envelope in this presentation.

What is a Building Envelope? Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities What is a Building Envelope? Roof/ceiling Exterior walls Vertical fenestration (glazing) and skylights Lowest floor Slab edge Below grade walls

Building Envelope Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Building Envelope Sealing Filling small spaces in building envelope with a soft waterproof material Vapor Barrier Membrane that restricts the movement of moisture Insulation Material used to reduce the transmission of heat Fenestration Glass used in the building envelope Four important considerations with respect to the building envelope are sealing, vapor barrier, insulation, and fenestrations.

Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Sealing Requirements All fenestration, openings, joints, and seams in the building envelope must be sealed with one of the following Caulk Gasket Tape Moisture vapor-permeable wrapping material

Insulation Requirements Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Building Envelope Requirements for Climate Zone 5 This table is based on the 2009 International Energy Code Requirements for nonresidential buildings and provides the insulation maximum U for the entire assembly and the required insulation R-value

Roof Insulation Requirement Keystone Library Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Roof Insulation Requirement Keystone Library Insulation entirely above deck: R-20 c.i. Where c.i. = continuous insulation SURFACING INSULATION METAL DECK STEEL OPEN WEB JOIST

Wall Insulation Requirement Keystone Library Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Wall Insulation Requirement Keystone Library Mass wall above grade: R-11.4 c.i. What types and thicknesses of insulation would meet the code in this application? BRICK AIR GAP A masonry or concrete wall is considered a mass wall. So the existing walls in the Keystone building are mass walls. The new second floor wall may be something other than a mass wall. R-11.4 INSULATION 8” CMU

Floor Insulation Requirements Keystone Library Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Floor Insulation Requirements Keystone Library Mass floor (slab-on-grade) unheated: no requirement Note: When required, this perimeter insulation must be placed around the exterior edge of the slab. Accepted perimeter insulation configurations

Opaque Door Requirements Keystone Library Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Opaque Door Requirements Keystone Library Opaque doors have < 50% glass area Door type Swinging door: U-0.700 (or less) Overhead door: U-0.500 (or less)

Reminder: U-Factor Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Reminder: U-Factor The rate of heat loss through the window The lower the U-factor, the less heat is lost Reciprocal of R-value (1/R)

Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Fenestration All areas (including the frames) in the building envelope that let in light Examples include windows, plastic panels, clerestories, skylights, glass doors that are more than one-half glass, and glass block walls A skylight is a fenestration surface having a slope of less than 60 degrees from the horizontal plane

Fenestration Requirements Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Fenestration Requirements Fenestration selection is often strongly influenced by energy codes U-Factor and Solar Heat Gain Coefficient may be specified in codes Wonder Window, Co.

Fenestration Requirements Keystone Library Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Fenestration Requirements Keystone Library Fenestration area must be less than 40% maximum of above grade wall area Building Envelope Requirements for Climate Zone 5 The insulation requirements for fenestrations is given in terms of U-factors and Solar Heat Gain Coefficients.

Fenestration Requirements Definitions Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Fenestration Requirements Definitions Curtain Wall – Fenestration products used to create an external non-load bearing wall that is designed to separate the exterior and interior environments Storefront – A nonresidential system of doors and windows mulled as a composite fenestration structure that has been designed to withstand heavy use Entrance Door – Fenestration products used for ingress, egress, and access in nonresidential buildings, including but not limited to, exterior entrances that utilize latching hardware and automatic closers that contain over 50% glass specifically designed to withstand heavy use and possible abuse

Solar Heat Gain Coefficient (SHGC) Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Solar Heat Gain Coefficient (SHGC) The fraction of incident solar radiation admitted through a window Expressed as a number between 0 and 1 The lower a window's solar heat gain coefficient, the less solar heat it transmits

Overhangs and Fenestration Requirements Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Overhangs and Fenestration Requirements Overhangs can decrease requirement for SHGC (in some climates) Calculate the Projection Factor, PF

Solar Heat Gain Coefficient (SHGC) Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Solar Heat Gain Coefficient (SHGC) Southern climates with high cooling loads SHGC is more important than the U-factor in promoting energy efficiency Choose lowest SHGC possible Northern climates with insignificant cooling loads Choose highest SHGC to promote solar heat gain during cold weather

SHGC Requirements Keystone Project Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities SHGC Requirements Keystone Project If : U-0.40 or less Otherwise: no requirement

Vestibule Requirements Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Vestibule Requirements A small entrance area between the outer door and the interior door Required at entrance leading to spaces ≥ 3000 ft2 Doors must have self-closing devices Exceptions: Buildings in climate zone 1 Doors from guest room or dwelling Doors for vehicles, material handling, and adjacent personnel doors DOE

Energy Codes Civil Engineering and Architecture® Unit 3 – Lesson 3.3 – Services and Utilities Resources Barlett, R., Halverson, M.A., & Shankle, D. L. (year). Understanding building energy codes and standards. Publication no. PNNL-14235: U. S. Efficient Windows Collaborative. (n.d.). Retrieved December 15, 2009, from http://www.efficientwindows.org/ Department of Energy. (n.d). Building energy codes program. Retrieved December 15, 2009, from http://www.energycodes.gov/implement/ International Code Council (2009). International energy conservation code and ANSI/ASHRAE/IESNA standard 90.1 2007 energy standard for buildings except low rise residential buildings. Country Club Hills, IL: Author.