Air-Condition controller

Slides:



Advertisements
Similar presentations
TIS Climate Control Course 20 Minutes Test 10 Minutes TIS Training Program 2012, Rev 1.1
Advertisements

TECHNICAL TRAINING Mini Chiller Panel Controller V2.0.
WebStat™ Programming and Configuration of Thermostats.
Total HVAC Control from anywhere Easy control that can save a fortune
Air Condition Design Course 20 Minutes Test 10 Minutes.
April 2004 page 1 Confidential and propietary CentraLine Portfolio c l o s e t o y o u.
MDS Smart Commander.
Settings & Adjustments. Settings & Adjustments.
How to setup Genesis LC1 and Genesis Flex with the Buffalo Access Point to maximize wireless performance…
DLP LCD PANEL Programming
Applied Systems News FWEC*A Rudolf BARET HEISSIG.
GSM sites Cooling systems description Standard Air Conditioner SystemEmergency Cooling SystemEnergy Saving Cooling System Air Conditioner Cooling system.
TECHNICAL TRAINING SMART COMMANDER System Requirements CPU : 800MHz and aboveCPU : 800MHz and above Memory : 256MB RAM or HigherMemory : 256MB.
HVAC Wiring diagram 5 channel output (5A relay) Speed: High/Medium/Low Mode: Cooling / Heating /Dehumidifier HVAC is a module specially for Air Conditioner.
DMX Controller SB-DN-512DMX.
Service Section Technical Training December 2005.
HDL KNX System Introduction
TOUCH Life SB-WL-TL7 SB-MBL-TS10-CE Windows XP. Touch screen function manual Click the icon 5 times to exit Room select key Room Function Icon function.
Infrared Remote Description Remote control distance : About 5m Two modes: 1. Default control Mode( for all Panel) 2. Page control Mode ( for DLP using,
SB-DN-HVAC (MAC01.331) Air-Condition controller.
Buspro Wireless Last update: April 10, HDL-MCIP-RF.10 Connections: Buspro, Ethernet, Buspro wireless Work Mode: Mesh mode or Bridge mode Wireless.
目录 12 in 1 Sensor Features ● PIR motion sensor ● Ultrasonic sensor ● LUX sensor ● Temperature sensor ● 2 Dry contacts ● 2 external condition inputs ● IR(infrared)
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
Solutions for Hotel HDL-MHRCU.431.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
Curtain Controller SB-DN-2Motor. SB-DN-2Motot is a professional two curtains(shutters) controller. The curtain module can control the curtain by AC motor.
0 Configuring a 3500 Using iTools 2 iTools Workshop - getting started Start iTools and from the New File menu choose 3504 v1.04 programmer.
Detect Range : 5×5m Detect Angle : 110 Degree Bus Port : HDL-BUS(485bus) Detect distance( sensitivity ): Adjustable via Software, from 1 to 100 Dimension.
6 CH 5A LED Dimmer HDL-MDLED /2/2016 Description HDL-MDLED CH 5A Intelligent LED Dimming Module, it can be used to control the LED.
ENERGY SAVING AND EFFICIENCY OF AIR CONDITION & LIGHT SYSTEMS AT PUBLIC BUILDINGS Meitav-tec (Contel group)
Refer to Service Manual for details Fault codes. To retrieve fault codes from the remote controller Press the ‘CHECK’ button for approximately.
ABB i-bus® EIB Shutter Actuators
System Important Points for Wiring
Fan Coil Controller FC/S 1.1
DIN Rail Music Player HDL-MZDN.432A.
Integration AC System.
Gateway HDL-MBUS01IP.431.
Wireless Power Interface
DIN Rail Music Player HDL-MZDN.432A.
Multifunctional Sensor
ILife App.
CHIGO VRF System Commissioning.
SB-DN-Logic960 Logic module.
6 CH 5A LED Dimmer HDL-MDLED
SMS module HDL-MGSM.431.
FCU Controller M/FCU
ABB i-bus® KNX Light Controller LR/S x.16.1 with LF/U 2.1.
FLoor Heating Controller
Power meter SB-DN-PM1P03 SB-DN-PM3P02.
Text آشنایی بیشتر با کنترلر هوشمند زیمنس
Computer and Information Technology for HKCEE
Security module SB-DN-SEC250K.
Dry contact sensor HDL-MSD04.40 HDL-MSD08.40.
Blower-/Fan Coil-Actuator
DMX Controller SB-DN-48DMX.
3V System Product Training
Haiwell PLC Modules Introduce
Pneumatics Module 9 Time delay valve.
FLoor Heating Controller
Wireless 4 Buttons Touch Panel
IR Emitter module SB-IR-EM.
Wireless 3 Buttons Touch Panel
Curtain Actuator M/W
Curtain Motor HDL-MWM70B.12 HDL-MVSM45B.12.
PowerValue 11/31 T Sales Presentation
Roof Top Unit Overview (MAGNUM)
Module 1 – Power Supply AMC APS-PBC-60
ACOE347 – Data Acquisition and Automation Systems
Total HVAC Control from anywhere Easy control that can save a fortune
Table of contents Getting started Panel configuration with Eldes Utility Tool Setting automation parameters Practical examples.
Presentation transcript:

Air-Condition controller SB-DN-HVAC (MAC01.331)

Description SB-DN-HVAC (MAC01.331) module designed to control centralized HVAC or FCU, through HDL control panel with air-conditioning function, depending on the preset ,current temperature and with the built-in algorithm

Main functions It has three relays to control modes ( cooling, heating and dehumidification) Three relays to control fun speed ( low, medium and high) Built-in controlling algorithm which can control the air-conditioner smartly. Can be connected up to 4 PCS of DS18B20( Digital Temperature Sensor, supplied by HDL) One master module can control about 8 slave modules. Support online upgrading

Wiring

Setting page The main tab for setting main configurations

Setting page Delay settings:- The compressor delay helps to protect the HVAC module from several problems, so it’s better to set some delay for each compressor. (refer to the manual of FCU)

Setting page VAV fan voltage output settings If the fan of FCU is controlled by DC 0-10V, then connected the fan to the DC 0-10V port of HVAC module, and set the fan speed controlling voltage in ‘VAV Fan voltage Setting’. (the voltage of fan speed, you can refer to the manual of FCU)

Setting page AC model settings: There three different modes for the AC model settings regarding the wiring diagram a) Normal mode: the wiring should be like this: relay1=cooling; relay2=heating; relay3=humidity.

Setting page AC model settings: b)complex mode: if the cooling/heating/humidity/fan/close mode need to use more than one channel to control, you can use complex mode. 12/28/2017 12/28/2017

Air setup page There are two different operation ways. a) Fully control: the module has ability to control itself, and can be controlled directly from iLife app. the time for compressor, you can refer to the manual of FCU. 12/28/2017

The temperature can refer to inner sensor or bus sensor, when refer to bus sensor, click “help” button, it would detect the device which can broadcast temperature automatically. Read sensor every 3s

Air setup page Operation way: b) Slave control: the module can only be controlled via a DLP, other device (e.g. iLife) can only control HVAC through the DLP. 12/28/2017 12/28/2017

Setting page AC model settings: example for complex mode: cooling=relay1 on; heating=relay1 & relay2 on. Attention: Enable simple mode means disable this function 12/28/2017 12/28/2017

Air setup page Host settings one master HVAC module can control up to 8 slave HVAC modules synchronously. e.g. below screen shot control the slave HVAC (1-5) synchronously. Click “Help”, it would detect the HVAC module automatically 12/28/2017

AC model settings: c) Force cooling mode: the wiring should be like this: ModeⅠ=Normal cooling;ModeⅡ=Force cooling channel; Mode Ⅲ=Narmal relay. Tip: when it is more than 2degree difference between setpoint and current temp, would open the force cooling chanel.

Test page Test settings: The wiring test ensures that every relay has been wired correctly and that the system can operate safely, so before programming an end-user panel, the relay wiring can be tested here.

Application 1 HVAC in Slave control mode, DLP in Fully control mode. HVAC setting: Select full control 12/28/2017 12/28/2017

Application 1 HVAC in Slave control mode, DLP in Fully control mode. DLP AC page setting: Enable AC function, fill in the ID of HVAC, select the type of AC. If HVAC has two control modes, it would be old type; If it has three control modes, it would be new type. Check this option 12/28/2017

Application 2 HVAC in Fully control mode, DLP in Slave control mode. HVAC setting: Select full control 12/28/2017 12/28/2017

Application 2 HVAC in Fully control mode, DLP in Slave control mode. DLP AC page setting: Enable AC function, fill in the ID of HVAC, select the type of AC. If HVAC has two control modes, it would be old type; If it has three control modes, it would be new type. Uncheck PS: more information, please refer to the user manuals of HVAC and DLP. 12/28/2017 12/28/2017

12/28/2017