SP series solar Pump inverter Introduction. Application.

Slides:



Advertisements
Similar presentations
INVERTERS: The Investigation to the
Advertisements

MODULAR SMPS POWER PLANT
Inverters Alex Stanton Henry Schober III Benjamin Garber Rance.
LP33 Series UPS kVA 400Vac/CE
NT series introduction UPS training June 2006 Markus Schwab.
Power Electronics Chapter 6 AC to AC Converters ( AC Controllers and Frequency Converters )
Copyright by UNIT III DC Choppers 4/17/2017 Copyright by
Chapter 8 Inverters AC Power • Inverters • Power Conditioning Units • Inverter Features and Specifications.
Inverters. Inverter Functions Change DC to AC Change DC to AC Increases or decreases voltage from array voltage to: Increases or decreases voltage from.
Solar Home UPS 850VA & 1400VA India’s first Sine wave inverter with in built Solar Charge Controller and Controlled DC Load Output. Simultaneous Charging.
To develop a small scale solar powered system that will power a DC load, which incorporates power management techniques, DC-DC conversion and a user interface.
LECTURE 9 INTRO TO POWER ELECTRONICS
DC POWER SUPPLY. Maeil Power Co.,Ltd is a one of leading supplier of switching power supply. The company design and manufacture quality products that.
0 Confidential String inverters for commercial PV applications David Smith, November 2013.
Off-Grid Power Using Enphase Micro-Inverters Off-grid inverter systems, using batteries, can be used to provide AC power when the grid is down. It is possible.
Station Battery Solar AC Source Home Batteries Battery Chargers.
LECTURE 28 AC Voltage Controllers Dr. Rostamkolai
Renewable Energy as Priority
Sustainable Energy Systems Engineering Peter Gevorkian Ch 2: Solar Power Generation Design Brevard Community College EST1830 Bruce Hesher.
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
The PV industry challenge of reaching grid parity
Hybrid Wind & Solar Generation Project
1 EE462L, Fall 2011 Motor Drives and Other Applications.
Janus Convertible Line – interactive Series UPS
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
Confidential / Property of Danfoss Drives A/S DKDD-SMC 1 Drives Division Danfoss presents - VLT ® 2800 Series.
MonoDrive & XT Constant Pressure Controller
Modular Inverter.
LECTURE 25 Controlled Rectifiers Dr. Rostamkolai
Balance of Systems (BOS)
YASKAWA VS-606 V7 COMPACT VECTOR - CONTROLLED INVERTER FOR GENERAL USE 230V (Single-Phase).1Kw ~ 3.7Kw (.13HP ~ 5HP) 230V (Three-Phase).1Kw ~ 7.5Kw (.13HP.
Fall 2009 Module 8 Inverters. Converts the DC power produced by the solar modules into AC power used on the utility grid.
Top manufacturer of AC Drive in China! Creative Technology, Service Leading! Shenzhen & Suzhou China AC Drive/
Product Introduction Reported by Jerry Huang
1\ Backup system for solar on-grid installation 1 1pcs XTM inverter charger, nominal power 3.5KVA, 30min. Power 4KVA AC DC Load2 (secured power)
1: Introduction of solar water pump system 2: Solar Pump Application 3: PV Panels 4: Solar Pump Inverter Function 5: Veichi Solar Pump Inverter.
Solar Pumps- High profitability and reliability lead to prosperity.
Renewable Energy Systems David Buchla | Thomas Kissell | Thomas Floyd Copyright © 2015 by Pearson Education, Inc. All Rights Reserved Buchla, Kissell,
SEC598F16 Photovoltaic Systems Engineering Session 12 PV System Components Inverters Balance of Systems (BOS) October 04, 2016.
UNIT III DC Choppers.
Photovoltaic and Battery Primer
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
SMPS.
PV100&PV200 Solar Pumping VFD
Power Electronics and Control in Wind Energy Conversion Systems
Speed control of three phase induction motor
FR200L & Wire Drawing Machine
UPS Sales Training Book Angela Hsu
MEDIUM VOLTAGE APPLICATIONS.
Introduction to Electrical Drive
Pompa Tenaga Surya The Complete Efficient Solar Water Pumping System.
- Corporation Introduction -
FEEDER PROTECTION UNIT
Dr. Unnikrishnan P.C. Professor, EEE
Energy. Anytime. Anywhere.
Best-in-class modular UPS ensuring business continuity
FR200L & Wire Drawing Machine
From Lecture1 vi , ii vo , io Power Processor Controller Source Load
Inverters Converting dc to ac
Model Output Current Battery Life BATPSU VDC 2A 1.2Ah BATPSU VDC 2.3Ah
ACOE347 – Data Acquisition and Automation Systems
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
Grid Tied PV Systems – C&I scale Siting and Mechanical Considerations
Solar Drive Enclosure and ATV312 Solar Drive
PowerLogic™ offer for the basic metering market
SMPS POWER PLANT SMR 48V/25A SALIENT FEATURES
Inverters Converting dc to ac
MAX VS Huawei Brand Growatt HW Advantage Model 50K/60K/70K/80KTL3 LV
600 V HIGH VOLTAGE SOLUTION η μ.
Presentation transcript:

SP series solar Pump inverter Introduction

Application

1. Built-in MPPT solar charger 2. Supports three-phase asynchronous motor 3. Built-in full protection and self-diagnosis 4. Soft stop function prevents water hammer effect and extends system lifecycle 5. Comprehensive LEDs and display screen for real-time system status 6. Remote monitoring through RS-485

 Water Pump Inverter sometimes is also called “Pump Driver” or “Pump Controller”. This inverter is used to manage the motors to make the water pump operation smoothly and extend the lifetime during the service.  SP solar pump inverter would convert the PV power to drive the motor directly. There is no battery for energy storage on this inverter. The battery-less design would help to reduce the system maintenance cost and the inverter would work when sun raises and it will turn off automatically after sunset which is suitable for the remote sides.  Inbuilt the MPPT SCC to maximize the PV energy for the connected loads.  Supporting the soft start to reduce the starting surge current. Soft stop to avoid the “Water Hammer Effect” to extend the system service time.  Inbuilt the real time protections for Dry Pumping, Phase Loses, Motor Locked, Short Circuit, Water Level Detection, Anti-Lightning, Over-Heating.  LED/LCD display the real time system status and parameter setting  The RS232/RS485 remote monitoring system will be ready in the near future.

Off Grid Solar system -Inverter  The typical output of PV Inverter or UPS is Pure Sinewave of 380/220Vac with 50/60Hz. But the output of SP series model is High Frequency Impulse with Sinewave current waveform. The Sinewave current could make the motors running smoothly without bring the initial surge current.  SP series uses the fixed V/F ratio at V/F=380V/50Hz. We change the F to adjust the motor speed and the maximum F is less than 50Hz.

Input TypePV Input BrandSP modelIxxxSxx Static PerformanceGoodWorstWorse Dynamic PerformanceGood Worse MPPT PerformanceGoodWorseWorst Speed ControlGoodWorseWorst Low PV Input Working No Working Constant Voltage SettingYes No Pump NoiseNormal Big Low Frequency NoiseNormal Big LCD DisplayReal StatusSetting Only

Comparison – Soft Start During the Soft Start Period. SP offers smooth output current for the connected pump. Sxx brand Inverter has unstable output voltage and worst current. Ixxx brand Inverter has worst current and unstable output voltage which may set the inverter gets fault. SP model COMPETITOR’S CHART ( SXX BRAND I XX BRAND)

SP Sxx Brand From below waveform, SP inverter model provides the stable voltage and current output with best MPPT performance. But Sxx brand Inverter is worse and Ixxx brand Inverter is with worst performance. Comparison – Sufficient PV Input

 Even with variable PV input, SP model still could adjust the output to keep the system running stable. But Sxx & Ixxx brand inverter both switch to fault mode then turn off the output. SP inverter Competitor brand

 The available power rating of Solar pump inverters are 2.2KW/7.5KW/11KW for 3 different models.  SP solar pump inverter only supports the 3-Phase AC motor for 380/400/415/4440Vac voltages.  SP solar pump inverter could not support the 1-Phase AC motor even the rating is smaller than 1-Phase Power of the Solar pump inverter  SP solar pump inverter only could support the pump with less or equal rating, but could not support the rating of pump higher than the Inverter rating.  After the first time connecting the pump to SP model, user needs to do the initial configuration according to the spec label of the pump on Rated Voltage/Rated Current/Rated Frequency and Rated capacity. This configuration is only needed for the 1 st time after pump installation.

MODEL 2.2KW 7.5KW11KW Maximum DC Voltage 800 VDC MPPT Voltage Range 500 VDC ~ 600VDC Number of MPP Trackers 1 Maximum Input Current5.8 A20.5 A27 A  We recommend the total PV Vmp is around 560Vdc to get the maximum MPPT output.  Panel Types: A. 75-A: 75W, Vmp=17.46V, Imp=4.3A, Voc=21.96V B. 75-B: 75W, Vmp=13.3V, Imp=5.64A, Voc=16.94V C. 140-A: 140W, Vmp=17.9V, Imp=7.82A, Voc=22.0V D. 250-A: 250W, Vmp=30.64, Imp=8.16A, Voc=37.38V MODEL 2.2KW 7.5KW11KW PV Panel 75-A 32 in Series (2400W PV Panels) PV Panel 75-B 42 in Series (3150W PV Panels) PV Panel 140-A 32 in Series x 2 Strings (8960W PV Panels) 32 in Series x 3 Strings (13440W PV Panels) PV Panel 250-A 19 in Series x 2 Strings (9500W PV Panels) 19 in Series x 3 Strings (14250W PV Panels)

MODEL 2.2KW 7.5KW11KW Maximum PV Array Power3500 W12000 W17600 W Rated Output Power2200 W7500 W11000 W PV INPUT (DC) Maximum DC Voltage 800 VDC Start-up Voltage 350 VDC MPPT Voltage Range 500 VDC ~ 600VDC Number of MPP Trackers 1 OUTPUT Nominal Voltage3 x 380/400/415/440 VAC Efficiency> 97% Output Current5.1 A17 A26 A Motor TypeThree-phase asynchronous motor Frequency Precision±0.2% PROTECTION Full Protection Over-voltage, under-voltage, over-current, surge, over-temperature and short circuit protection PHYSICAL Dimension, D X W X H (mm)110 x 230 x 342 Net Weight (kgs) Type of Mechanical ProtectionIP20 INTERACE Communication PortRS-232/RS-485 ENVIRONMENT Humidity< 95% RH (No condensing) Operating Temperature-20°C~45°C at 100% full load, 46°C~60°C power derating