PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004.

Slides:



Advertisements
Similar presentations
Beam-plug and shielding studies related to HCAL and M2 Robert Paluch, Burkhard Schmidt November 25,
Advertisements

LC Calorimeter Testbeam Requirements Sufficient data for Energy Flow algorithm development Provide data for calorimeter tracking algorithms  Help setting.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
Status of DHCAL Slice Test Data Analysis Lei Xia ANL-HEP All results preliminary.
W. Clarida, HCAL Meeting, Fermilab Oct. 06 Quartz Plate Calorimeter Prototype Geant4 Simulation Progress W. Clarida The University of Iowa.
IHEP,Protvino,Russia 1 Current status of a gas luminosity monitor Sergei Erin † † For the LCAL group V.Bezzubov,S.Erin, A.Ferapontov, Yu.Gilitsky,V.Korablev,
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
The performance of LHCf calorimeter was tested at CERN SPS in For electron of GeV, the energy resolution is < 5% and the position resolution.
Slide 1 Diamonds in Flash Steve Schnetzer Rd42 Collaboration Meeting May 14.
Far forward angle physics at the LHC E. Norbeck and Y. Onel University of Iowa For the 24th Winter Workshop on Nuclear Dynamics South Padre Island
Design and test of a high-speed beam monitor for hardon therapy H. Pernegger on behalf of Erich Griesmayer Fachhochschule Wr. Neustadt/Fotec Austria (H.
M.Gallinaro, ``Innovative Particle and Radiation Detectors’’, Siena, October slide 1 The CDF MiniPlug Calorimeter Forward Physics Conceptual.
ALPHA Storage Ring Indiana University Xiaoying Pang.
E. Norbeck U. IowaFast Gas Detector APR 05 Tampa1 Small Fast Gas Detector for High-Energy Electrons E. Norbeck, J.E. Olson, and Y. Onel University of Iowa.
Rad Hard Active Media for Calorimeters E. Norbeck, J.E. Olson, A. Moeller, and Y. Onel University of Iowa PPAC Čerenkov Liquid with Tungsten metal.
SHMS Optics and Background Studies Tanja Horn Hall C Summer Meeting 5 August 2008.
Jornadas LIP 2008 – Pedro Ramalhete. 17 m hadron absorber vertex region 8 MWPCs 4 trigger hodoscopes toroidal magnet dipole magnet hadron absorber targets.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
PHENIX Local Polarimeter PSTP 2007 at BNL September 11, 2007 Yuji Goto (RIKEN/RBRC)
BES-III Workshop Oct.2001,Beijing The BESIII Luminosity Monitor High Energy Physics Group Dept. of Modern Physics,USTC P.O.Box 4 Hefei,
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
HE CALORIMETER DETECTOR UPGRADE R&D Y. Onel for University of Iowa Fairfield University University of Mississippi.
CALICE 03/14/05Ed Norbeck U. of Iowa1 PPACs in a Calorimeter Edwin Norbeck University of Iowa.
Combined Function Magnets/Calorimeters ■ Introduction ■ Superconducting magcal concept ■ Geant4 studies ♦Birmingham ♦Liverpool ■ Summary Insertion of GO.
Development of Digital Hadron Calorimeter Using GEM Shahnoor Habib For HEP Group, UT Arlington Oct. 12, 2002 TSAPS Fall ’02, UT Brownsville Simulation.
Ion signals with R134a and R134 in a parallel plate proportional counter Edwin Norbeck, J. E. Olson, Y. Onel University of Iowa For Sec. DH-3 of DNP06.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
Luminosity Monitoring Issues  ZDC  what’s the advantage?  problems  BBC  can they do it? A. Drees QCD critical point workshop, Mar
CaTS and Dual Readout. CaTS – Calorimeter and Tracker Simulation Describe detector in gdml file (xml like) Define.
Quartz Plates R&D Status By F. Duru, S. Ayan, U. Akgun, J. Olson, Y. Onel The University Of Iowa V.Podrasky, C. Sanzeni, D.R.Winn Fairfield University.
00 Cooler CSB Direct or Extra Photons in d+d  0 Andrew Bacher for the CSB Cooler Collaboration ECT Trento, June 2005.
Ion signals with R134a and R134 in a parallel plate proportional counter Y. Onel, E. Norbeck, J. E. Olson University of Iowa For HCAL meeting at Fermilab.
FCC-hh HCAL software goals Ana Henriques (thanks for Clement Helsens, Carlos Solans input)
Geant4 Tutorial, Oct28 th 2003V. Daniel Elvira Geant4 Simulation of the CMS 2002 Hcal Test Beam V. Daniel Elvira Geant4 Tutorial.
Lucia Bortko | Optimisation Studies for the BeamCal Design | | IFJ PAN Krakow | Page 1/16 Optimisation Studies for the BeamCal Design Lucia.
PPAC in ZDC for Trigger and Luminosity Edwin Norbeck University of Iowa Luminosity Workshop November 5, 2004.
Quartz Plate Calorimeter Prototype Hardware & Preliminary Test Beam Data Anthony Moeller The University of Iowa.
1 ZDCs in CMS Michael Murray,U Kansas pp Lum EMHad PMTs Lead/ plastic Fiber 1.5cm tungsten plates 2mm plates Beam LED Spare space for flow upgrade Light.
Robert R. Wilson Prize Talk John Peoples April APS Meeting: February 14,
Gas detectors in a ZDC (at LHC) Edwin Norbeck and Yasar Onel University of Iowa For7 th CMS Heavy-Ion meeting at Delphi June 2003.
Small, fast, low-pressure gas detector E. Norbeck, J. E. Olson, and Y. Onel University of Iowa For DNP04 at Chicago October 2004.
W Prototype Simulations Linear Collider Physics & Detector Meeting December 15, 2009 Christian Grefe CERN, Bonn University.
H. Matis, S. Hedges, M. Placidi, A. Ratti, W. Turner [+several students] (LBNL) R. Miyamoto (now at ESSS) H. Matis - LARP CM18 - May 8, Fluka Modeling.
PPAC Jonathan Olson University of Iowa Thesis Defense 8 April 2005.
1 Status of Zero Degree Calorimeter for CMS Experiment O.Grachov, M.Murray University of Kansas, Lawrence, KS A.S.Ayan, P.Debbins, E.Norbeck, Y.Onel University.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
I nstrumentation of the F orward R egion Collaboration High precision design ECFA - Durham2004 University of Colorado AGH University, Cracow I nstitute.
SHIP calorimeters at test beam I. KorolkoFebruary 2016.
PPAC Parallel Plate Avalanche Counter Edwin Norbeck University of Iowa For meeting at SLAC June 2, 2004.
Diamond – Tungsten Calorimeter LCAL-group : K. Afanasiev, V. Drugakov, E. Kouznetsova, W. Lohmann, A. Stahl Workshop on Forward Calorimetry and Luminosity.
Status of Zero Degree Calorimeter for CMS Experiment
Ultra fast SF57 based SAC M. Raggi Sapienza Università di Roma
IOP HEPP Conference Upgrading the CMS Tracker for SLHC Mark Pesaresi Imperial College, London.
The ATLAS Zero Degree Calorimeter Brookhaven National Laboratory, USA
A Digital Hadron Calorimeter Resistive Plate Chambers
Explicitly Radiation Hard Fast Gas Cerenkov Calorimeter
HE Calorimeter Upgrade Studies
Present coverage Possible upgrade projects Slogan: Q C D HERA for LHC
Jin Huang Los Alamos National Lab
Testbeam comparisons arXiv:
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Scintillator HCAL: LOI issues
CASA Collider Design Review Retreat Other Electron-Ion Colliders: eRHIC, ENC & LHeC Yuhong Zhang February 24, 2010.
LHC (SSC) Byung Yunn CASA.
The Measurement of Forward Particle Production in LHC
Update on Ecal simulation
Status Report on MCP PET Simulation
LC Calorimeter Testbeam Requirements
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

PPAC Jonathan Olson University of Iowa HCAL November 11-13, 2004

Nov. 13, 2004PPAC J. Olson U. Iowa2 Example of low-pressure PPAC (Parallel Plate Avalanche Counter) Two flat plates Separated by 1 mm Filled with 80 torr isobutane 1000 V between plates Operates in avalanche mode MIPs often leave no signal Showers give large signal directly into 50 Ω

Nov. 13, 2004PPAC J. Olson U. Iowa3 PPAC in HE Three flat plates, separated by 1 ~ 2 mm Middle plate at high voltage Outer plates hold atmospheric pressure Gas flows in one side and out the other Plates can be made of same material as the absorber. Beam In

Nov. 13, 2004PPAC J. Olson U. Iowa4 Individual PPAC to replace Scintillators Coax and gas lines extend out of radiation area No organic materials in high-radiation region Beam In

Nov. 13, 2004PPAC J. Olson U. Iowa5 PPAC Readout - + Summing amplifier can be used to add PPAC signals, increasing the effective size of PPAC (without increasing the time width of the signals)

Nov. 13, 2004PPAC J. Olson U. Iowa6 Radiation damage A PPAC can be entirely metal and ceramic so that it will not be damaged by radiation levels expected with the SLHC upgrade. Also makes it a good choice for the ZDC. If PPACs are chosen for ZDC, we would have a significant investigation phase prior to HE upgrade

Nov. 13, 2004PPAC J. Olson U. Iowa7 Beam In Zero Degree Calorimeter The green is solid metal (W). Detectors that sample the shower are shown in blue. Detector near front end is for EM shower

Nov. 13, 2004PPAC J. Olson U. Iowa8 CONCLUSIONS PPACs in a ZDC Can be made radiation hard. Can provide transverse position information. Have good energy resolution. Have sub nanosecond time resolution. Can be integrated to give average luminosity. Can be replaced without removing the ZDC. ZDC can be left in place for both pp and PbPb

Nov. 13, 2004PPAC J. Olson U. Iowa9 1.8 ns 50 torr 790 V 7 mv into 50  Fast signals Single peak with considerable noise. The noise is large because of the small size of the signal using our 137 Cs source. With the much larger signals from high-energy showers, the noise will be negligible.

Nov. 13, 2004PPAC J. Olson U. Iowa10 PPAC ion signal Fast electron signal is followed by a small, slow (500 ns) signal from ions moving between the plates. The slow ion signal is easily removed.

Nov. 13, 2004PPAC J. Olson U. Iowa11 Ion collection time (1 mm spacing) 0.3  s 0.5  s 50 torr 790 V

Nov. 13, 2004PPAC J. Olson U. Iowa12 Poor for single, low-energy heavy ion Current per  m   is huge! Same size signal from shower has good energy resolution. Measure resolution with double PPAC Look at ratio between two sides Double PPAC for Energy Resolution

Nov. 13, 2004PPAC J. Olson U. Iowa13 Double PPAC for testing energy resolution

Nov. 13, 2004PPAC J. Olson U. Iowa14 Ion and electron signals with 2 mm spacing 168 pF 1.6  s 6.2ns 1.3  s Amplified signal using gamma source. Positive overshoot is from amplifier. Ion collection time is three times as long with the 1 mm spacing.

Nov. 13, 2004PPAC J. Olson U. Iowa15 For high speed, the RC time constant must be kept small. Only PPACs of small area are fast, ~1 ns R = 50 Ω (coax cable). C is the capacity between the plates Small PPAC ~1 ns C =.885 pF for 1 mm gap and area of 1 cm 2 Larger PPAC with C = 168 pF for 2 mm gap and area of 1 cm 2 rise time ~5 ns fall time ~7 ns Still fast enough for the HE where minimum beam crossing time is 25 ns. Speed vs Size

Nov. 13, 2004PPAC J. Olson U. Iowa16 Tests with double PPAC Test with EM showers using 80 ps bunches of 7 GeV positrons from the Advanced Photon Source, at Argonne National Laboratory Test with low energy hadron showers using the 120 GeV proton test beam at Fermilab

Nov. 13, 2004PPAC J. Olson U. Iowa17 PPAC Test at ANL IOWA double PPAC was tested for energy resolution with electron showers from the Advanced Photon Source (APS) at Argonne National Laboratory. The booster ring of the APS puts out 76 ps bunches of 7 GeV positrons at the rate of two per second, with 3.6 x positrons in each bunch. In normal operation the positrons are injected into the main storage ring where they are used to produce synchrotron radiation. There are maintenance and development periods during which the beam is directed into a beam dump. We set up our equipment next to the beam line just in front the beam dump. The entire beam bunch has an energy of 2.5 x eV, or 2.5 x 10 8 TeV, much more than we needed. The PPAC was close to the beam line and so was exposed to showers generated by the outer halo of the beam striking the beam pipe. Because of the small angle between the positrons and the wall of the beam pipe, the wall acted as an absorber with a thickness of several centimeters. The showers were developed in this absorber.

Nov. 13, 2004PPAC J. Olson U. Iowa18 Energy Resolution Data of PPAC Test at ANL Ratio E front to E back is constant to within ± 2%

Nov. 13, 2004PPAC J. Olson U. Iowa GeV proton test Measured signal size (into 50 Ω, no amplification) at shower maximum. Maximum signal from detector placed after 30 cm of iron was 17 mV. TeV hadron showering in copper would give a much larger signal.

Nov. 13, 2004PPAC J. Olson U. Iowa20 No “Texas tower effect” With above-atmosphere hydrocarbon gas occasional proton from n-p scattering gives huge signal. In PPAC, proton hits wall at almost full energy. PPAC signal mostly from low-energy electrons. We will test this with detailed simulations.

Nov. 13, 2004PPAC J. Olson U. Iowa21 Simulation Efforts Investigation using GEANT4