© 2015 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Eaton software.

Slides:



Advertisements
Similar presentations
Essentials of project management Lecture 8. Targets of Lecture Introduction to project management –Understanding the target process in typical projects.
Advertisements

1 Building a New Electric World How can your LV electrical installation be rapidly designed and optimized?
Modeling Electrical Systems With EMTP-RV
NETWORK ANALYSIS IN GIS ENVIRONMENT Uday Deshmukh North Delhi Power Limited.
Chapter 14 Network Design and Implementation. 2 Network Analysis and Design Aspects of network analysis and design Understanding the requirements for.
(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved. 1 SCCR Applying High Fault Ratings Component HOTT.
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Welcome DIN Rail product training ISOLATOR/MCB/RCD/RCBO
Access 2007 ® Use Databases How can Microsoft Access 2007 help you manage a database?
MIG II DIGITAL FEEDER PROTECTION
1 EXPERIENCE AND RELIABILITY. 2 Short circuit loop measurements EN EN
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
Troubleshooting Electric Control Devices
Stork Prints Austria GmbH bestIMAGE 5.60 CAM Plus, CAM smart December 2012 Explore the new features of.
Term 2, 2011 Week 3. CONTENTS The physical design of a network Network diagrams People who develop and support networks Developing a network Supporting.
Electrical Installation 2
Electrical Distribution Training
Group 8 Dennis Pimentel Dale Tikasingh Emilio Fernandez Florida International University 20 April 2006 TDL POWER TDL.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
Frontiers in Massive Data Analysis Chapter 3.  Difficult to include data from multiple sources  Each organization develops a unique way of representing.
© Siemens AG 2012 / All rights reserved. 5SM6 AFD Units – Advanced Preventative Fire Protection Comprehensive protection against fires caused by electricity.
PowerIT Air Insulated Cubicle Uniswitch
First Draft Language (B) Service Equipment. In addition to the requirements in (A), service equipment shall contain the following information: (1)
© 2015 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Eaton software.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
CAD-Profi 2007 CAD Library CAD-Profi 2007 About CAD-Profi 15 years experience in branch M.Sc. Adam Czubek- CAD-Design M.Sc. Jacek Kosiorek- CAD-Sales.
XSpider.
Chapter 8 Final Construction Final construction in the SDLC Construct and test programs Construct and test the database Obtain additional hardware Prepare.
Suggestion on How to Use
Suggestion on How to Use
M. R. Gouvea BR Session 1 – Block 1 – Transformers – Paper #36 Barcelona May RISK CRITERIA TO APPLY AND MANAGE DISTRIBUTION TRANSFORMERS M.
PROGRAMMING FUNDAMENTALS INTRODUCTION TO PROGRAMMING. Computer Programming Concepts. Flowchart. Structured Programming Design. Implementation Documentation.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
© 2011 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Eaton 3S.
Transfer Switch 16A/30A Affordable Redundancy with easy deployment
© 2012 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Eaton Aurora.
Development of CAD concept model of package transformer substation (PTS) Aleksandra Seledkova Perm National Research Polytechnic University.
© 2008 Eaton Corporation. All rights reserved. Introduction to IEC/TR A status update and insides Bas Bouman Hans Meulenbroek Manager Damstra Lab.
Unit 3 Computer Systems. What is software? unlike hardware it can’t be physically touched it’s the missing link between the computer hardware and the.
Database Principles: Fundamentals of Design, Implementation, and Management Chapter 1 The Database Approach.
ELECTROTECHNIC. LARGE RANGE OF ROTARY MACHINES AND ACCESSORIES Educational equipment & solutions for technical training institutes & Universities 90W.
© 2008 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Electrical.
This is a photographic template – your photograph should fit precisely within this rectangle. © 2016 Eaton. All rights reserved. Eaton software tools xSpider.
InstalSystem 5.
Graphical Data Engineering
STO/GM December 2011 ABB STOTZ-KONTAKT GmbH ABB i-bus® KNX DGN/S DALI Gateway for emergency lighting © STO/G - Slide 1.
智能电力检测设备专业制造商和供应商 1 1.
IMS Map360 – What is it? IMS Map360 is a desktop CAD software solution that lets users import, process, analyze, visualize and create court ready deliverables.
PSCAD models.
Systems Engineering Tool for Intelligent Transportation
Mastering Autodesk Revit MEP 2016 CHAPTER 14: Circuiting and Panels
Investigating the Design Context.
CHAPTER 3 Architectures for Distributed Systems
Webinar – New KStutor Overview 25th October 2013
The New RAPID TPM A NEW PLATFORM FOR TURBO PETROL ENGINES Leading name in the world of the additional module applied to Turbo Diesel engines for over.
Engineering Project Cable Management.
Introduction to Software Testing
EET 323 – Electrical System Design Lecture 4: Wiring Devices
Engineering Tools for Electrical and Computer Engineers
xSpider DEMO – Export list of devices and import it to other software
xSpider DEMO – Simultaneous Factor and Parallel Sources
Instructional presentation
Topics Module 5 Logical And Physical Design User Interface Design
Extended Learning Module G
Educational Computing
Electrical components and systems
Unit J: Creating a Database
SISTEMA Example Three.
Presentation transcript:

© 2015 Eaton Corporation. All rights reserved. This is a photographic template – your photograph should fit precisely within this rectangle. Eaton software tools xSpider 3 – new generation 2016 Software for dimensioning and calculation of low-voltage networks

© 2015 Eaton. All Rights Reserved.. xSp i der 3.0 was born !

3 © 2015 Eaton Corporation. All rights reserved. General features (1/2) xSpider 3 Software tool for dimensioning and calculation of low-voltage networks User friendly interface New powerful kernel, ready for big projects Suitable for TN / IT / TT network systems up to 1000V Design of radial as well as meshed networks Design of networks supplied from one or more different power supplies (supply network, transformer, generator) Option of using simultaneous (K s ) and utilisation factors (K u ) Option of simulating various operating states of network by disconnecting individual power sources and loads Operation state manager - complex simulation of various operating states

4 © 2015 Eaton Corporation. All rights reserved. General features (2/2) xSpider 3 Software tool for dimensioning and calculation of low-voltage networks Database of components with transparent tree structure All calculations are based on applicable IEC standards - voltage drops, load distribution, short circuit currents, etc. Selectivity: working with tripping characteristics and selectivity spread sheets (tested combinations) ArcRISK module: evaluation of risks caused by Arc-Flash Generation of documentation + reports - wiring diagram with calculation results - calculation report - tables of element parameters and calculation results

5 © 2015 Eaton Corporation. All rights reserved. xSpider 3 User interface Flexible graphics area Tool Box Error List Ribbon MDI interface  Docked panels  All panels are sizable Property Grid User operation similar to standard CAD systems (AutoCAD)

6 © 2015 Eaton Corporation. All rights reserved. xSpider DEMO drawings Preview applications Typical applications with short description of essential topics Easy learning with readymade drawings Quick access eg. via Tool box

7 © 2015 Eaton Corporation. All rights reserved. Voltage drops, load distribution Check whether voltage drop does not exceed the user-defined threshold, set locally for every network component Check of correct dimensioning of the circuit protection equipment and conductors Voltage in the node Voltage drop in the node xSpider Calculations Current in the node

8 © 2015 Eaton Corporation. All rights reserved. Three-phase short circuit current Maximal short circuit current Check of correct dimensioning of the circuit protection equipment and conductors (check of breaking capacity I cu or I cs ) Check of whole network or fault in selected node I k3p – initial impulse SC current i p3p – peak SC current Component with error (insufficient breaking capacity I cs ) xSpider Calculations

9 © 2015 Eaton Corporation. All rights reserved. One-phase short circuit current Minimal short circuit Calculation of disconnection time Check of whole network or fault in one node T tr – disconnection time Node with short-circuit xSpider Calculations I k1p - initial impulse 1-phase SC i p1p - peak 1-phase SC

10 © 2015 Eaton Corporation. All rights reserved. Evaluation of design Tripping characteristics with tolerance fields (desk study) Selectivity and back-up protection spreadsheets (tested values) xSpider Selectivity and back-up protection Selection of protective devices from the network and/or from database Assesment of selectivity and back-up protection according tested values

11 © 2015 Eaton Corporation. All rights reserved. xSpider Operation state manager Simulation of various operation states of the network Disconnecting power sources and loads Each switching component has two operation states: on / off. Each motor has two operating states: start / stable operation

12 © 2015 Eaton Corporation. All rights reserved. xSpider ArcRISK module Evaluation of Arc Flash Hazard Analysis Calculation of incident energy during short circuit flash Hazard analysis according to IEEE 1584™, 2002 (EN ,-2) Safety improvements by Eaton‘s solutions (Diagnose, ARMS™, ARCON) Unique feature of xSpider Application training on request

13 © 2015 Eaton Corporation. All rights reserved. xSpider Solved example - step by step The most effective way how to learn working with xSpider Basic knowledge of operations with applications running under Windows as well as fundamental orientation in the issues concerning low-voltage network dimensioning is presumed. The instructions refer to the relevant chapters from the xSpider User’s Manual, part II – program operation

14 © 2015 Eaton Corporation. All rights reserved. xSpider is provided for free, after registration at: Licence is provided for a limited period of time (update of program, database) User manual is part of installation or available separately (PDF file) Instruction videos help with quick understanding of operation Technical support and troubleshooting: More information available at the address: Eaton Industries (Austria) GmbH Scheydgasse 42, A-1215 Wien, Austria Tel.: , xSpider Software tool for dimensioning and calculation of low-voltage networks